Search NASA⌕ Search

SEARCH · Search NASA

Results for “Experimental Test Range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Off-design performance of an organic Rankine-vapor compression cooling cycle using R1234ze(E)

In this study, a 264 kW th organic Rankine-vapor compression cycle (ORVC) was experimentally tested over a range of conditions to quantify the individual impact of off-design external conditions. The ORVC was designed to recover waste heat at 91 °C, reject heat to a liquid condenser stream at 30 °C, and produce chilled water at 7 °C. Here, the condenser heat rejection temperature was varied from 16.6 °C to 32.6 °C, the chilled water delivery temperature was varied between 2.1 °C and 13.1 °C, and the heat input temperature was varied from 91 °C to 120 °C. As the condenser heat rejection temperature decreased, the coefficient of performance (COP) of the ORVC improved from 0.558 at 30 °C to 0.682 at 16.6 °C, despite a reduction in compressor isentropic efficiency. Although the chilled water temperature variation had almost no impact on the organic Rankine cycle performance, the compressor efficiency decreased when the delivery temperature was below 7 °C. At the highest chilled water temperature, 13.1 °C, the COP of the ORVC was 0.643. Compressor stall was noted when the condenser heat rejection temperature was greater than 32.6 °C and the chilled water delivery temperature was below 2.1 °C. Increasing the driving heat source inlet temperature improved the COP of the ORVC and the thermal efficiency of the organic Rankine power cycle, while decreasing the efficiency of the compressor and the COP of vapor compression cycle. In addition, the integrated part load value of the system was determined through experimentation to be 0.682, which provides a realistic estimate of real-world performance.

30 DIRECT ENERGY CONVERSION↗

Angle Droop Design for Grid-Forming Inverters Considering Impacts of Virtual Impedance Control

Grid-forming inverters (GFMs) based on active power-frequency droop control and reactive power-voltage droop control have been developed in recent years, which can generate voltage and frequency references for islanded power systems or microgrids to improve system-wide synchronization and power-sharing capability. It is known that the control delays in GFMs may cause system harmonic instability. To eliminate this issue, virtual impedance techniques are normally adopted. This paper gives a comprehensive examination of the impacts of virtual impedance control block Z v in GFMs on system stability. It is revealed that although Z v is effective in eliminating system harmonic stability, it may ruin system synchronization stability as a side effect. To compensate for the negative impacts caused by Z v , an active power-angle control block is added into the conventional droop control. Design criteria are also proposed accordingly to ensure system stability over the entire frequency range. Simulations and experimental testing are conducted to validate the analysis and the proposed design guidelines. It can be concluded that the Z v control-caused grid-synchronization instability issues can be eliminated with an appropriate active power-angle droop design.

Kong, Le↗

National energy savings potential of cellular shades: A measurement and simulation study

Windows are major contributors to energy demand in residential homes because of their inferior thermal resistance compared with the opaque envelope, and sometimes from unwanted solar heat gain. Window attachments can help mitigate the energy demand by controlling the solar heat gains and enhancing window thermal resistance. Cellular shades have the potential of superior thermal performance compared with generic shades because of its honeycomb structure. Here, in this study, the team analyzed the energy savings potential of cellular shades in residential homes via experimental testing for two heating seasons and energy simulations. Five shading devices—three single-cell and two double cellular/cell-in-cell shades—were used to compare the performance with generic horizontal venetian blinds using two nearly identical side-by-side rooms in a residential home. The experimental testing showed daily heating energy savings in the range of 17%–36% compared with the case without shades. The experimental testing data also exhibited improvements in thermal comfort when using cellular shades. Additionally, energy simulations were performed to evaluate the energy savings potential of the cellular shades using a residential prototype home, which demonstrated energy savings up to 9 kWh/m2/year in cold climates. The total site energy savings for heating and cooling from cellular shades was up to ~9% for the home with a heat pump and up to ~15% for a home with a gas furnace compared with cases without any shading devices. The energy savings at a national scale were up to 14.6 TWh assuming a 20% penetration rate in residential homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An extrapolation method for strain ranges and hold times in developing the EPP+SMT creep-fatigue design curves for Alloy 617

Experimental and numerical studies in developing the integrated Elastic–Perfectly Plastic (EPP) plus Simplified Model Test (SMT) design methodology, referred to as the EPP+SMT method, continued in FY2022. This report focuses on the methods for extrapolating the EPP+SMT creep-fatigue (CF) design curves at long hold times and low strain ranges. In this study, the available CF failure data on Alloy 617 at 950°C were analyzed to determine a set of CF failure criteria. At very low strain ranges and long hold times, CF failure data are not accessible by experiments because of the extraordinarily long test durations and the inability of the test machines to accurately control these small strain ranges. A CF experimental approach with the concept of block-strain range CF testing protocol was developed. Tests using this protocol were conducted to generate the needed information for calibrating material parameters of the numerical material models. The Time Fraction based method and Dissipated Energy method were used to extrapolate the CF life curves to low strain ranges and long hold times. Based on the new experimental approach and CF life prediction methods, the CF life curves with various hold times were developed for Alloy 617 at 950°C. In addition, an experiment was designed and is being performed to verify the predicted CF curves at 950°C. The extrapolation procedure will be applied at lower temperatures to complete the development of the EPP+SMT CF design curves for Alloy 617 in F2023.

36 MATERIALS SCIENCE↗

A practical approach for identifying various polarization behaviors of redox-stable electrodes in symmetrical solid oxide fuel cells

In symmetrical solid oxide fuel cells, comprehensively understanding the elementary reaction processes and the polarization behaviors of redox-stable electrode materials is critical for further optimization of the electrode performance. In this work, a systematical and practical approach, based on electrochemical impedance spectroscopy technology, is applied to identify the rate-limiting elementary reactions of the redox-stable electrodes. The feasibility of this proposed method is demonstrated in symmetrical solid oxide fuel cells with Sr 2 Fe 1.5 Mo 0.5 O 6-σ -Ce 0.9 Gd 0.1 O 1.95 as electrodes. Based on the characteristic frequency ranges and the experimental results tested under various fuel gas components, operating temperatures, and discharge current densities, the rate-limiting steps of the cathode are associated with the formation of adsorbed oxygen ions and the combination of oxygen ions and oxygen vacancies, while the rate-limiting steps of the anode are ascribed to the hydrogen dissociated adsorption and the steam desorption processes. This experimental and analysis framework can be straightforwardly extended to other electrode materials to unravel their electrochemical performance in detail.

25 ENERGY STORAGE↗

Experimental validation of simplified radionuclide transport bubble scrubbing code in sodium coolant pool

Solid radionuclides released following fuel pin failure may become entrained in gaseous fission products and be rapidly transported through the coolant pool to the cover gas region. Sensitivity studies on radionuclide transport have identified this potential pathway as one of both high concern and high uncertainty. The simplified radionuclide transport scrubbing code utilizes classical aerosol scrubbing mechanisms to model this phenomenon and predict aerosol masses reaching the cover gas region. This paper serves to validate this code in a sodium environment while conducting a parametric study to analyze the effects of aerosol size, bubble size, pool temperature, pool depth, aerosol density, and aerosol concentration. Through a series of experimental tests, it was determined that aerosol sizes ranging from 0.001 to 1.0 µm are of primary concern as aerosols in this range have a ratio of aerosol mass entering the sodium pool from the fuel pin to aerosol mass exiting the sodium pool to the cover gas region of less than 10. Further, the experimental results were found to match the trends found in the scrubbing model closely, but significantly more scrubbing was seen experimentally. Decreasing bubble size and increasing pool depth and aerosol density were all found to increase scrubbing both experimentally and theoretically. Pool temperature was found to have a negligible effect on scrubbing amounts; however, this was largely due to a subsequent increase in bubble size corresponding to increasing temperatures which offset the increase in scrubbing due to increased temperature. Varying aerosol concentration was found to have no effect on scrubbing ratios. A final series of tests was conducted for a more prototypic fuel pin failure with a heterogenous bubble swarm. From these tests, it was found that the experimental scrubbing quantities were larger than for the single bubble case. Overall, it was found that the simplified bubble transport scrubbing code accurately models the trends of the bubble scrubbing but provides a conservative estimate of scrubbing quantities. Model limitations fail to model the complex phenomena present for fission product scrubbing via bubble transport, but match trends seen experimentally.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Testing in Support of the Development of EPP Plus SMT Design Method at ORNL (FY2021)

Experiments in support of the development of the integrated Elastic–Perfectly Plastic (EPP) plus Simplified Model Test (SMT) design methodology, referred to as the EPP+SMT method, continued in FY21. This report focuses on the methodology for developing the EPP+SMT creep-fatigue (CF) design curves at low strain ranges. The creep damage-based method and dissipated work-based method were used to evaluate the available CF data at the low strain range region. A set of failure criteria were determined, and a simple extrapolation method was developed to predict the CF life cycles at low strain ranges that are not accessible by experiments due to the extraordinarily long failure times at the low strain region (thousands to hundreds of thousands of years) and the inability of the test machine to control these small strain ranges due to the signal to noise issues. An experimental method with the concept of block-strain range CF testing was proposed to generate the information needed to extrapolate the CF design curves to low strain ranges. Based on this new testing approach, a preliminary EPP+SMT CF design curve was developed for Alloy 617 at 950°C with tension hold time of 100 s. The analysis in this report shows the potential of generating a set of EPP+SMT CF design curves with different hold times within a reasonable amount of time and testing effort. Based on such a progress, a hold time extrapolation procedure for low strain ranges will be developed in FY22 and critical testing will be carried out to complete the development of the EPP+SMT CF design curves for Alloy 617.

36 MATERIALS SCIENCE↗

Evaluation of Interior Cellular Shades in a Residential Building

Windows are major contributors to energy demand in residential homes because of their inferior thermal resistance compared with the opaque envelope and sometimes from unwanted solar heat gain. Window attachments can help to mitigate this demand by controlling the solar heat gains and enhancing the thermal resistance of the windows. In this study, the energy savings potential of cellular shades in residential homes is studied using experimental testing and energy simulations. The energy performance of the shading devices was experimentally tested during the heating season from December 2019 to May 2020 with a focus on cellular shades. Five shading devices—three single and two double cellular/cell-in-cell shades—were used to compare the performance with generic horizontal (venetian) blinds using two nearly identical sideby-side rooms in a residential building with their exterior window facing east. Another objective of the experimental testing was to evaluate any impact of the side-channel of the shading device on energy savings. To observe the impact of the side-channels on energy savings, from shades in two of the test cases, cellular shades with side-channels were used. From the experimental testing, daily energy savings in the range of 9% to 23% were observed by considering data from 6 p.m. until 6 a.m. of the next day.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensitivity Effects of High Temperature Overhead Conductors to Line Rating Variables

For traditional overhead transmission lines, the maximum allowable conductor operating temperature on ASCR, AAC, or AAAC lines for determining the static line ratings can be quite low, typically well under 100 C. At these low temperatures, the primary driver for determining static line ratings are assumptions made about the wind speed and direction and the ambient temperature. Assumptions for solar loading and emitted thermal radiation, driven by line emissivity and absorptivity, are secondary factors, and only provide small changes to the static ratings. However, when considering newer high temperature conductors such as ACSS, ACCR, ZTACIR, and ACCC® the maximum allowable conductor temperatures can be significantly higher, up to 250° C. This higher temperature shifts the importance of the emissivity assumptions of the overhead transmission line, due to the nature of the T4 dependence of the radiative heat loss compared to the T1 dependence of the convective heat loss, as well as shifting the dependency on local wind conditions. Typical assumptions in the United States for the emissivity/absorptivity of overhead transmission lines in determining the static ratings are to use a value of 0.5 for both parameters or set a value in the range of 0.7 to 0.9. Recent experimental tests at EPRI have shown that higher emissivity aging assumptions may not be valid in some regions of the US, and that actual values may be much lower (0.25-0.45) than older studies have predicted (0.8-0.9). Here, the assumptions of different US Regional Transmission Operators (RTOs) and different utilities within RTOs are examined for the static ratings for traditional lower operating temperatures up to 100° C as well as with the higher maximum temperature conductors associated with newer conductor designs at 250° C. The sensitivity of the static ratings is examined at both lower and higher temperature conductors with respect to overhead line emissivity and absorptivity, wind speed, wind direction, and solar loading, and ambient temperature. It is shown that the effects of the conductor absorptivity, solar flux and ambient temperature on the static rating are increased when the transmission line has a lower maximum conductor temperature. The effects of the conductor emissivity, wind direction and wind speed have increased effects on the static rating when the transmission line has a higher maximum conductor temperature. In addition, example weather data is used to calculate the conductor temperature with different line emissivity and absorptivity assumptions. This shows the effect of assumptions made for emissivity only has a minor impact for low temperature lines, but for high temperature transmission lines can cause a 150-200° C temperature swing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Results from Laboratory and Field Study of Thin Triple Pane Windows

Heat transfer through windows accounts for a significant percentage of a building’s energy use and adds substantially to the peak cooling load of a home. In recent years, improvements in glass manufacturing have enabled the use of a very thin central pane of glass similar to a cell phone screen to produce a thin triple-pane window, for finished insulated glass units (IGUs) with an overall thickness similar to standard double-pane windows. Because this highly insulating “thin triple” glass product can be incorporated into almost any existing window frame and can be fabricated at a modest added cost, the U.S. Department of Energy sponsored laboratory and field demonstration testing of thin triple-pane windows to validate thermal performance and installation requirements in real-life field settings. Thin triple pane windows were evaluated at the PNNL Lab Homes, a matched pair of manufactured houses located on PNNL’s campus in Richland, Washington and also at 16 different field study sites around the country. The experimental results include a comparison of heating, ventilation, and air-conditioning (HVAC) energy usage, condensation potential, occupant comfort, sound infiltration, and thermal performance. Field study data will be gathered through June of 2022; preliminary results are being shared in this paper. The lab houses are identical except that the reference house had standard double pane windows with assembly U-0.66 and the test house had thin triple pane windows with assembly U-0.19. Across the experimental test days, the daily HVAC savings ranged from 0.2 to 18.7 kWh (3%–18%) for the heating season and from 2.5 to 8.0 kWh (23%–41%) for the cooling season. The higher thermal performance of the thin triple-pane windows also reduced the condensation potential on the interior surface during winter months and provided more even distribution of temperatures throughout the home in comparison to the baseline. In addition to the added thermal performance, the thin triple-pane windows demonstrated significant acoustic benefits, reducing sound infiltration by 8 dB to 10 dB. For the field test portion of the project thin triple pane insulated glass units were produced by two different manufacturers, and then installed without modification into the ½” IGU pockets of the standard double pane frames of four other manufacturers. Field tests performed on existing homes in Washington, Montana, Colorado, and New York compared thin triple pane retrofits to original window conditions (before and after). Field tests at new construction sites in Minnesota, Michigan, and New York compared thin triple pane windows to commercially available solutions such as double pane or traditional triple pane (with a standard-thickness center pane). Field test work is ongoing, but preliminary results appear to follow the sound, surface temperature, and energy improvement results from the Lab Homes comparison. Additionally, reports from builders and installers indicate that thin triples require almost no added time or effort to install and look nearly identical to other windows, indicating the possibility of offering next-level performance with a product that requires very little modification to current production or installation practices, long considered a major barrier to technology uptake in the construction market.

energy efficiency, home retrofit, Windows, window ↗

FOSWEC dynamics and controls test report

This report describes the testing of a model scale wave energy converter. This device, which uses two aps that pivot about a central platform when excited by waves, has a natural frequency within the range of the waves by which it is excited. The primary goal of this test was to assess the degree to which previously developed modeling, experimentation, and control design methods could be applied to a broad range of wave energy converter designs. Testing was conducted to identify a dynamic model for the impedance and excitation behavior of the device. Using these models, a series of closed loop tests were conducted using a causal impedance matching controller. This report provides a brief description of the results, as well as a summary of the device and ex- perimental design. The results show that the methods applied to this experimental device perform well and should be broadly applicable.

16 TIDAL AND WAVE POWER↗

Experiments towards a neutron target for measurements in inverse kinematics

Neutron-induced reactions play an important role in fundamental nuclear physics, nuclear astrophysics, and applications. In the case of reactions on rare isotopes, there are limited options for direct experimental measurements. The Neutron Target Demonstrator project at Los Alamos National Laboratory seeks to test the feasibility of moderating spallation neutrons within a 1 m 3 graphite cube to create a standing neutron target for neutron-induced reaction measurements in inverse kinematics. This paper presents the results of experimental neutron flux distribution tests using neutron sources (ranging from 1 keV to 50 MeV) created by accelerators at the University of Notre Dame and Texas A&M University. Measurements were made with both the full graphite cube as well as a ”half cube” setup in which half of the graphite cube was removed. The measured distributions agree with simulated distributions in the case of the full cube moderator, although there remain discrepancies in certain cases for the half cube moderator. The results shown here will provide useful information for an upcoming experimental campaign to test the neutron target proof-of-principle.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The beam test of the lead tungstate calorimeter prototype with SiPM readout at Jefferson Lab

The lead tungstate crystals (PWO4) are a well-known radiator material for precise homogeneous electromagnetic calorimetry. In nuclear physics experiments, the typical way to read out the crystals is using conventional photomultiplier tubes (PMTs). In the case of the presence of a magnetic field, such a method has some complications and requires a passive PMT shielding design. The recent development of Silicon Photomultipliers (SiPMs) with small pixel pitch sizes and relatively small noise levels opens an opportunity avenue to use such a device as an alternative to conventional PMTs. The SiPM readout method may be beneficial for future nuclear physics and collider experiments. We are presenting the beam test results of the calorimeter prototype instrumented with SiPM readout performed at Jefferson Lab. The SiPM readout performance was compared with PMT readout measured at the same experimental conditions. The prototype was successfully tested using beam of photons in the energy range between 3 GeV and 11 GeV in experimental Hall D. The detector performance was also studied using a secondary beam of positrons provided by Hall D pair spectrometer.

Berdnikov, Vladimir↗

Synchrophasors-based Master State Awareness Estimator for Cybersecurity in Power Grid: Testbed Implementation & Field Demonstration

The integration of distributed energy resources(DERs) and expansion of complex network in the distribution grid requires an advanced distributed state estimator to monitor the grid health at micro-level. The distribution state estimator will improve the situational awareness and resiliency of distributed power system. This paper proposes a synchrophasors-based master state awareness (MSA) estimator to enhance the cybersecurity in distribution grid by providing a real-time estimation of system operating states to control center operators. In this paper, the proposed MSA estimator utilizes only phasor measurements, bus magnitudes and angles, from phasor measurement units (PMUs),deployed in local substations, to estimate the system states and also detects data integrity attacks, such as load tripping attack that disconnects the load. To validate the proof of concept, we implement the proposed methodology in cyber-physical testbed environment at the Idaho National Laboratory (INL) Electric Grid Security Testbed. Further, to address the “valley of death” and support technology commercialization, field demonstration is also performed at the Critical Infrastructure Test Range Complex(CITRC) at the INL. Our experimental results reveal a promising performance in detecting load tripping attack and providing an accurate situational awareness through an alert visualization dashboard in real-time

42 ENGINEERING↗

Validation of Thermal Scattering Laws for Light Water at Elevated Temperatures with Diffusion Experiments

Light water is the most important neutron moderator in many reactor applications. Thermal neutron scattering kernels for H bound in H 2 O are represented by ENDF-format thermal scattering laws (TSLs) evaluated at discrete temperatures T . Nuclear data evaluations are conventionally validated utilizing a combination of critical benchmarks and experimental cross section data. Existing public critical benchmarks may be inadequate for testing water TSLs over the full range of T of interest in reactor applications, and experimental thermal scattering cross section data for water is sparse at elevated T . In this work, MC21 is used to simulate the decay of the equilibrium thermal neutron flux in light-water spheres of several radii. The fundamental-mode time eigenvalue $\mathcal{a}$ is calculated at 22 °C and 227 °C (at saturation pressure) for each sphere using three different H-H 2 O TSLs. Fitting $\mathcal{a}$ to a polynomial function of geometric buckling allows calculation of the thermal neutron diffusion length L . Extrapolation lengths are treated as a function of the transport mean free path and geometry. Experimental L data from 25 publications at 49 temperatures (from 10 °C to 295 °C), computed by several different time-dependent and space-dependent decay methods, is used to develop an empirical fit of L vs. T . The MC21-calculated L for the TSLs tested are within ±1% of the predicted values at 22 °C and 227 °C. This validation approach, which may be repeated at arbitrary T , constitutes an integral benchmark specific to and characterizing the detailed physics of the thermal scattering kernel applied.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Host Species–Microbiome Interactions Contribute to Sphagnum Moss Growth Acclimation to Warming

Sphagnum moss is the dominant plant genus in northern peatlands responsible for long-term carbon accumulation. Sphagnum hosts diverse microbial communities (microbiomes), and its phytobiome (plant host + constituent microbiome + environment) plays a key role in nutrient acquisition along with carbon cycling. Climate change can modify the Sphagnum -associated microbiome, resulting in enhanced host growth and thermal acclimation as previously shown in warming experiments. However, the extent of microbiome benefits to the host and the influence of host–microbe specificity on Sphagnum thermal acclimation remain unclear. Here, we extracted Sphagnum microbiomes from five donor species of four peatland warming experiments across a latitudinal gradient and applied those microbiomes to three germ-free Sphagnum species grown across a range of temperatures in the laboratory. Using this experimental system, we test if Sphagnum 's growth response to warming depends on the donor and/or recipient host species, and we determine how the microbiome's growth conditions in the field affect Sphagnum host growth across a range of temperatures in the laboratory. After 4 weeks, we found that the highest growth rate of recipient Sphagnum was observed in treatments of matched host–microbiome pairs, with rates approximately 50% and 250% higher in comparison to maximum growth rates of non-matched host–microbiome pairs and germ-free Sphagnum , respectively. We also found that the maximum growth rate of host–microbiome pairs was reached when treatment temperatures were close to the microbiome's native temperatures. Our study shows that Sphagnum's growth acclimation to temperature is partially controlled by its constituent microbiome. Strong Sphagnum host–microbiome species specificity indicates the existence of underlying, unknown physiological mechanisms that may drive Sphagnum 's ability to acclimatize to elevated temperatures. Together with rapid acclimation of the microbiome to warming, these specific microbiome–plant associations have the potential to enhance peatland resilience in the face of climate change.

acclimation↗

Advanced focusing system for secondary electrons in a bunch shape monitor

Non-destructive measurements of longitudinal beam profile in non-relativistic hadron accelerators are usually performed with Bunch Shape Monitors that utilize secondary electron emission to reproduce the shape of a primary ion beam. The existing devices, however, have poor electron collection efficiency from the wire and are limited to one dimensional measurements of the phase coordinate. Here, we present the development of a bunch shape monitor with improved performance for proton beams to be used in the Spallation Neutron Source accelerator. This improvement was achieved by adding focusing optics between the wire and the entrance slit, which will also allow measurements over a much higher dynamic range. Here we present the design, simulation and experimental test results of the developed new electron beam guidance system for the existing SNS bunch shape monitor that allowed significant improvement in the collection efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of intrinsically disordered protein variants with diverse structural properties

Intrinsically disordered proteins (IDPs) perform a broad range of functions in biology, suggesting that the ability to design IDPs could help expand the repertoire of proteins with novel functions. Computational design of IDPs with specific conformational properties has, however, been difficult because of their substantial dynamics and structural complexity. We describe a general algorithm for designing IDPs with specific structural properties. We demonstrate the power of the algorithm by generating variants of naturally occurring IDPs that differ in compaction, long-range contacts, and propensity to phase separate. We experimentally tested and validated our designs and analyzed the sequence features that determine conformations. We show how our results are captured by a machine learning model, enabling us to speed up the algorithm. Our work expands the toolbox for computational protein design and will facilitate the design of proteins whose functions exploit the many properties afforded by protein disorder.

Science & Technology - Other Topics↗