Search NASA⌕ Search

SEARCH · Search NASA

Results for “FAIMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Optimization of a New Aerodynamic Cylindrical FAIMS Device for Small Molecule Analysis

The implementation of an aerodynamic mechanism to improve ion sampling between nanoelectrospray (n-ESI) and FAIMS was recently reported for proteomic analyses. This investigation explores the new FAIMS interface for small molecule analysis at high liquid flow rates and includes an examination of key differences in ionization between heated-ESI (HESI) and n-ESI. The sheath gas, critical for desolvation with HESI, affects FAIMS operation as higher FAIMS gas flow rates are required to achieve sufficient desolvation. Gas flow rate experiments also uncovered m/z discrimination with the conventional design as larger (slower moving) m/z ions experienced larger signal intensity losses than smaller m/z ions due to the desolvation gas flow having a greater drag effect on slower moving ions. The modified inlet in new FAIMS dampens the gas drag, making the HESI source more amenable as less m/z bias and significantly lower %RSD values were observed. Furthermore, a larger radius inner electrode in new FAIMS enables significantly higher E/N (electric field/number gas density) to be achieved using the existing waveform generator. Thus, new FAIMS signal intensities using only nitrogen improved 1.25- to 2-fold compared with the conventional design and 50% helium. Adding helium to the new FAIMS gave no significant improvements. The larger inner electrode also decreased ion focusing capabilities, and the effect on peak separation and ion intensity was examined in detail. The peak capacity of new FAIMS was approximately double that of conventional FAIMS; separation of seven low m/z ions gave a peak capacity of 37.7 using the gas additive 2-propanol. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of Ion Motion in FAIMS through Combined Use of SIMION and Modified SDS

Over the years, the use of Field Asymmetric Ion Mobility Spectrometry (FAIMS) has grown with applications spanning from explosives detection to separation of complex biological mixtures. Although, the principles of ion separation in FAIMS is understood and comprehensively characterized, little effort has been made in developing commercially available computational tools that can simulate ion motion in FAIMS. Such a tool could be of great value for refining theory, optimizing the performance of the instrument for specific applications, and in modeling the fringe-fields caused by rf decay at the entrance and exit of FAIMS which can significantly affect ion transmission. An algorithm using SIMIONTM as its core structure was developed in this study to realistically compute ion trajectory at different ratios of electric field to buffer gas number density (E/N). The E/N can vary from a few Td to ~80 Td in FAIMS as created by an asymmetric square waveform. The Statistical Diffusion Simulation (SDS) model was further incorporated in the algorithm to simulate the ion diffusion in the FAIMS gap. The algorithm was validated using a FAIMS analyzer model similar to the Sionex Corporation model SVAC in terms of its dimensions and geometry. Hydroxyproline and Leucine ions with similar reduced mobility Ko (2.17 and 2.18 cm2.V-1.s-1, respectively) were used as model ions to test the new algorithm and demonstrate the effects of gas flow and waveform (voltage pulse amplitude and frequency) on peak shape and ion current transmission. Simulation results from three ion types: O2-(H2O)3, (A type), (C3H6O)2H+ (B type), and (C12H24O)2H+ (C type) were then compared with the experimental data (available in the literature). The SIMION-SDS-Field Dependent Mobility Calculation (FDMC) algorithm provided good agreement with experimental measurements of the ion peak position in FAIMS compensation voltage (CV) spectrum, peak width, and the ion transmission over a broad range of E/N.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improving FAIMS Sensitivity using a Planar Geometry with Slit Interfaces

Differential mobility spectrometry or field asymmetric waveform ion mobility spectrometry (FAIMS) is gaining broad acceptance for analyses of gas-phase ions, especially in conjunction with largely orthogonal separation methods such as mass spectrometry (MS) and/or conventional (drift tube) ion mobility spectrometry. In FAIMS, ions are filtered while passing through a gap between two electrodes that may have planar or curved (in particular, cylindrical) geometry. Despite substantial inherent advantages of the planar configuration and its universal acceptance in stand-alone FAIMS devices, commercial FAIMS/MS systems have employed curved FAIMS geometries that could be interfaced to MS more effectively. Here we report a new planar (p-) FAIMS design with slit-shaped entrance and exit apertures that substantially increase ion transmission in and out of the analyzer. The front slit interface effectively couples p-FAIMS to multi-emitter electrospray ionization (ESI) sources, improving greatly the ion current introduced to the device. The back slit interface increases the transmission of ribbon-shaped ion beams output by the p-FAIMS to downstream stages such as a MS. Overall, the ion signal in ESI/FAIMS/MS analyses is raised by over an order of magnitude without affecting the FAIMS resolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comprehensive Single-Shot Proteomics with FAIMS on a Hybrid Orbitrap Mass Spectrometer

Liquid chromatography (LC) prefractionation is often implemented to increase proteomic coverage; however, while effective, this approach is laborious, requires considerable sample amount, and can be cumbersome. We describe how interfacing a recently described high-field asymmetric waveform ion mobility spectrometry (FAIMS) device between a nanoelectrospray ionization (nanoESI) emitter and an Orbitrap hybrid mass spectrometer (MS) enables the collection of single-shot proteomic data with comparable depth to that of conventional two-dimensional LC approaches. This next generation FAIMS device incorporates improved ion sampling at the ESI–FAIMS interface, increased electric field strength, and a helium-free ion transport gas. With fast internal compensation voltage (CV) stepping (25 ms/transition), multiple unique gas-phase fractions may be analyzed simultaneously over the course of an MS analysis. We have comprehensively demonstrated how this device performs for bottom-up proteomics experiments as well as characterized the effects of peptide charge state, mass loading, analysis time, and additional variables. We also offer recommendations for the number of CVs and which CVs to use for different lengths of experiments. Internal CV stepping experiments increase protein identifications from a single-shot experiment to >8000, from over 100 000 peptide identifications in as little as 5 h. In single-shot 4 h label-free quantitation (LFQ) experiments of a human cell line, we quantified 7818 proteins with FAIMS using intra-analysis CV switching compared to 6809 without FAIMS. Single-shot FAIMS results also compare favorably with LC fractionation experiments. Furthermore, a 6 h single-shot FAIMS experiment generates 8007 protein identifications, while four fractions analyzed for 1.5 h each produce 7776 protein identifications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancing Top-Down Proteomics of Brain Tissue with FAIMS

Proteomic investigations of Alzheimer’s and Parkinson’s disease have provided valuable insights into neurodegenerative disorders. Thus far, these investigations have largely been restricted to bottom-up approaches, hindering the degree to which one can characterize a protein’s “intact” state. Top-down proteomics (TDP) overcomes this limitation, however it is typically limited to observing only the most abundant proteoforms and of a relatively small size. Therefore, offline fractionation techniques are commonly used to reduce sample complexity, limiting throughput. A higher throughput alternative is online fractionation, such as gas phase high-field asymmetric waveform ion mobility spectrometry (FAIMS). Using a high complexity sample derived from Alzheimer’s disease brain tissue, we describe how the addition of FAIMS to TDP can robustly improve the depth of proteome coverage. For example, implementation of FAIMS at -50 compensation voltage (CV) more than doubled the mean number of non-redundant proteoforms observed (1,833 ± 17, n = 3), compared to without (754 ± 35 proteoforms). We also found FAIMS can influence the transmission of proteoforms and their charge envelopes based on their size. Importantly, FAIMS enabled the identification of intact amyloid beta (Aß) proteoforms, including the aggregation-prone Aß1-42 variant which is strongly linked to Alzheimer’s disease.

59 BASIC BIOLOGICAL SCIENCES↗

Optimum Waveforms for Differential Ion Mobility Spectrometry (FAIMS)

Differential mobility spectrometry or field asymmetric waveform ion mobility spectrometry (FAIMS) has emerged as a major tool for separation and identification of gas-phase ions, particularly in conjunction with mass-spectrometry. In FAIMS, ions are filtered by the difference between mobilities in gases (K) at high and low electric field intensity (E) using asymmetric waveforms. An infinite number of waveform profiles is possible and maximizing the performance within engineering constraints is a major issue in FAIMS technology development. Earlier optimizations assumed the non-constant component of mobility to scale as E2, producing the same result for all ions. Here we show that the optimum profiles for either rectangular or sinusoidal-based waveforms are controlled by the full series expansion of K(E) that always includes terms beyond the 1st proportional to E2. For many ion/gas pairs, the first two terms have different signs and the optimum profiles at sufficiently high E in FAIMS may substantially differ from those found previously, improving the resolving power by up to 2 - 2.5 times. This situation arises for some ions in all FAIMS systems, but becomes more common with recent miniaturized units that employ higher E. With realistic K(E) dependences, the maximum waveform amplitude is not necessarily best and reducing it by up to 20 - 30% is beneficial in some cases. Present findings are particularly relevant to targeted analyses where separation depends on the spread between K(E) functions of specific ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pushing the Frontier of High-Definition Ion Mobility Spectrometry Using FAIMS

Differential ion mobility spectrometry (FAIMS) separates ions in gases based on the difference between their mobilities in strong and weak electric fields, captured directly employing a periodic waveform with dissimilar profiles in opposite polarities. As that difference is not tightly correlated with the ion size or mass, FAIMS separations are generally quite orthogonal to both conventional IMS (based on the absolute ion mobility that reflects the physical ion size) and mass spectrometry (based on mass). Until a few years ago, that advantage was largely offset by poor FAIMS resolving power (~10–20), an order of magnitude below that achieved with conventional (drift-tube) IMS. This article summarizes the major recent technical developments that have raised FAIMS resolving power up to ~500. These include use of higher and more stable voltages provided by new waveform generators, novel buffer gas compositions comprising high helium or hydrogen fractions, and extended filtering times up to ~1 s. These advances have enabled previously unthinkable analyses such as broad baseline separations of peptide sequence inversions, localization variants (post-translationally modified peptides with differing PTM attachment sites) even for the larger “middle-down” peptides and smallest PTMs, and lipid regioisomers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Trapping-Micro-LC-FAIMS/dCV-MS Strategy for Ultrasensitive and Robust Targeted Quantification of Protein Drugs and Biomarkers

The sensitivity of LC-MS in quantifying target proteins in plasma/tissues is significantly hindered by co-eluted matrix interferences. While antibody-based immuno-enrichment effectively reduces interferences, developing and optimizing antibodies are often time-consuming and costly. Here, in this study, by leveraging the orthogonal separation capability of Field Asymmetric Ion Mobility Spectrometry (FAIMS), we developed a FAIMS/differential-compensation-voltage (FAIMS/dCV) method for antibody-free, robust, and ultra-sensitive quantification of target proteins directly from plasma/tissue digests. By comparing the intensity-CV profiles of the target vs. co-eluted endogenous interferences, the FAIMS/dCV approach identifies the optimal CV for quantification of each target protein, thus maximizing the signal-to-noise ratio (S/N). Compared to quantification without FAIMS, this technique dramatically reduces endogenous interferences, showing a median improvement of the S/N by 14.8-fold for the quantification of 17 representative protein drugs and biomarkers in plasma or tissues and a 5.2-fold median increase in S/N over conventional FAIMS approach, which uses the peak CV of each target. We also discovered that the established CV parameters remain consistent over months and are matrix-independent, affirming the robustness of the developed FAIMS/dCV method and the transferability of the method across matrices. The developed method was successfully demonstrated in three applications: the quantification of monoclonal antibodies with sub-ng/mL LOQ in plasma, an investigation of the time courses of evolocumab and its target PCSK9 in a preclinical setting, and a clinical investigation of low abundance obesity-related biomarkers. This innovative and easy-to-use method has extensive potential in clinical and pharmaceutical research, particularly where sensitive and high-throughput quantification of protein drugs and biomarkers is required.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

[Interview]: Alexandre Shvartsburg, Pacific Northwest National Laboratory, Richland, WA, USA

Q1. What are your main research activities in ion mobility mass spectrometry (past or present)? My early efforts focused on the structural characterization of atomic (carbon and semiconductor) clusters. After the production of bulk fullerenes, many hoped that other nanoclusters discovered in the gas phase could also coalesce into new materials. As these studies required accurate and robust mobility calculations for any ion geometry, I strived to build the needed theory and implement it in the Mobcal software widely employed today. Since 2004, I have been developing methods and novel applications of differential IMS (FAIMS) at PNNL. The principal achievement has been raising the resolving power by over tenfold (up to ~400 for multiply-charged peptides) using elevated fields, helium and hydrogen-rich buffers, and extended filtering times. This performance broadly allows previously unthinkable separations of very similar species, for example sequence inversions and post-translational modification localization isomers of peptides (including “middle-down” peptides such as histone tails), lipid regioisomers, and even isotopomers. Another major direction is investigating the dipole alignment of larger proteins, which creates an exceptionally strong FAIMS effect that is a potential tool for structural biology. Q2: What have been the most significant instrumentation or applications developments in the history of ion mobility - mass spectrometry? In 1995 when I started graduate research at Northwestern, only two groups worldwide worked with IMS/MS and “the literature” meant papers by Bowers (UCSB). Well-wishers counseled me to “learn something useful like HPLC, as IMS would never have real utility”. This booklet showcases the scale of change since. First, the practical IMS/ToF platforms for complex biological analyses demonstrated by Clemmer have turned IMS/MS from an esoteric physical chemistry technique into a powerful analytical tool. By commercializing the IMS/ToF technology in Synapt instruments, Waters has greatly increased its impact via expanded number and diversity of applications. Concurrently, Guevremont at Canadian NRC has perfected FAIMS coupled to MS, deployed it for real-world bio and environmental analyses, and widely distributed it in the Ionalytics Selectra system (subsequently installed on Thermo MS platforms). The latest breakthrough is ultra-FAIMS by Owlstone, where extreme fields allow numerous qualitatively new separations and operational modes that we just begin to explore. Q3: Where do you see ion mobility - mass spectrometry making the most impact in the next 5 years? Any predictions for where the field will go? Sciences dealing with perturbations in media (such as optics or acoustics) at some point shift from the linear to nonlinear paradigm, where propagation depends on the magnitude of perturbation or its driving force. While the linear part remains industrially important (e.g., eyewear and architectural glass for optics), frontline research moves to nonlinear phenomena. IMS is undergoing that transition now with the rise of FAIMS, which should continue as the fundamental understanding improves, new modalities and applications emerge, and more instrumentation is introduced by vendors. Modifying and augmenting FAIMS separations through vapor dopants that render ion mobilities less linear is becoming routine. I expect this area to advance, extending to more specific interactions and to complexation with solution additives. Another route to higher separation power is integrating FAIMS with conventional IMS; proliferation of both technologies would make such 2-D platforms common. Along with mass spectrometry and conventional IMS, FAIMS will address increasingly large macromolecules, including proteins and their complexes.

Shvartsburg, Alexandre A.↗

Control of Ion Distortion in Field Asymmetric Waveform Ion Mobility Spectrometry via Variation of Dispersion Field and Gas Temperature

Field asymmetric waveform ion mobility spectrometry (FAIMS) has emerged as an analytical tool of broad utility, especially in conjunction with mass spectrometry. Of particular promise is the use of FAIMS and 2-D ion mobility methods that combine it with conventional IMS to resolve and characterize protein and other macromolecular conformers. However, FAIMS operation requires high electric fields and ions are inevitably heated by above-thermal collisions with buffer gas molecules. This may induce ion isomerization and dissociation that distort separation properties determined by FAIMS and subsequent stages and/or reduce instrumental sensitivity. As FAIMS employs a periodic waveform, the ion temperature can be characterized at the maximum or average field intensity (E). Which method is most applicable to temperature sensitive ions, such as protein ions, has been debated. Here we address this issue by measuring the unfolding of compact ubiquitin ion geometries as a function of waveform amplitude (dispersion field, ED) and gas temperature, T. The field heating is quantified by matching the dependences of structural transitions on ED and T. Increasing ED from 12 to 16 or from 16 to 20 kV/cm is equivalent to heating the (N2) gas by ~15 - 25 oC. The magnitude of field heating for any E can be calculated using the two-temperature theory, and raising ED by 4 kV/cm augments heating by ~15 - 30 oC for maximum and ~4 - 8 oC for average E in the FAIMS cycle. Hence, isomerization of ions in FAIMS appears to be governed by the maximum internal temperature at waveform peaks.

Robinson, Errol W.↗

Integration of paper spray ionization high‐field asymmetric waveform ion mobility spectrometry for forensic applications

Rationale Paper spray ionization (PSI) is an attractive ambient ionization source for mass spectrometry (MS) since it allows the combination of surface sampling and ionization. The minimal sample preparation inherent in this approach greatly reduces the time needed for analysis. However, the ions generated from interfering compounds in the sample and the paper substrate may interfere with the analyte ions. Therefore, the integration of PSI with high‐field asymmetric ion mobility spectrometry (FAIMS) is of significant interest since it should reduce the background ions entering the mass analyzer without complicating the analysis or increasing analysis time. Here we demonstrate the integration of PSI with FAIMS/MS and its potential for analysis of samples of forensic interest. Methods In this work, the parameters that can influence the integration, including sampling and ionization by paper spray, the FAIMS separation of analytes from each other and background interferences, and the length of time that a usable signal can be observed for explosives on paper, were evaluated with the integrated system. Results In the negative ion analysis of 2,4,6‐trinitrotoluene (TNT), pentaerythritol tetranitrate (PETN), octahydro‐1,3,5,7‐tetranitro‐1,3,5,7‐tetrazocine (HMX), and 1,3,5‐trinitroperhydro‐1,3,5‐triazine (RDX), amounts as low as 1 ng on paper were readily observed. The successful positive ion separation of a set of illicit drugs including heroin, methamphetamine, and cocaine was also achieved. In addition, the positive ion analysis of the chemical warfare agent simulants dimethyl methylphosphonate (DMMP) and diisopropyl methylphosphonate (DIMP) was evaluated. Conclusions The integration of PSI‐FAIMS/MS was demonstrated for the analyses of explosives in negative ion mode and for illicit drugs and CW simulants in positive mode. Paper background ions that could interfere with these analyses were separated by FAIMS. The compensation voltage of an ion obtained by FAIMS provided an additional identification parameter to be combined with the mass spectrum for each analyte.

Tsai, Chia‐Wei↗

Separation and Classification of Lipids Using Differential Ion Mobility Spectrometry

Correlations between the dimensions of a 2-D separation create trend lines that normally depend on structural or functional characteristics of the compound class and thus facilitate classification of unknowns. This broadly applies to conventional ion mobility spectrometry (IMS)/mass spectrometry (MS), where the major biomolecular classes (e.g., lipids, peptides, nucleotides) occupy different trend line domains. However, strong correlation between the IMS and MS separations for ions of same charge has impeded finer distinctions. Differential IMS (or FAIMS) is generally much less correlated to MS and thus should better separate the trend lines and associated domains. We report the first observation of chemical class separation by trend lines using FAIMS, here for lipids. For all lipids, FAIMS is indeed more independent of MS than conventional IMS, and subclasses (such as phospho-, glycero-, or sphingolipids) form distinct, often non-overlapping domains. Even finer categories with different functional groups or degrees of unsaturation are often separated. As expected, resolution improves in He-rich gases: at ~70% He, glycerolipid isomers with different positions of fatty acid attachment can be resolved. These results open the door for lipidomics application of FAIMS, particularly shotgun lipidomics and targeted analyses of bioactive lipids.

99 GENERAL AND MISCELLANEOUS↗

Differential Ion Mobility Separations in up to 100% Helium Using Microchips

The performance of differential IMS (FAIMS) analyzers is much enhanced by gases comprising He, especially He/N2 buffers. However, electrical breakdown has limited the He fraction in those mixtures to ~50 - 75%, depending on the field strength. By Paschen law, the threshold field for breakdown increases at shorter distances. This allows FAIMS using chips with microscopic channels to utilize much stronger field intensities (E) than “full-size” analyzers with wider gaps. Here we show that those chips can employ higher He fractions up to 100%. Use of He-rich gases improves the resolution and resolution/sensitivity balance substantially, although less than for full-size analyzers. The optimum He fraction is ~80%, in line with first-principles theory. Hence one can now measure the dependences of ion mobility on E in pure He, where ion-molecule cross section calculations are much more tractable than in other gases that form deeper and more complex interaction potentials. This capability may facilitate quantitative modeling of high-field ion mobility behavior and thus FAIMS separation properties, which would enable a priori extraction of structural information about the ions from FAIMS data.

Environmental Molecular Sciences Laboratory↗

High-Resolution Differential Ion Mobility Separations Using Planar Analyzers at Elevated Dispersion Fields

Analyses of complex or isomeric mixtures increasingly involve ion mobility spectrometry/ mass spectrometry (IMS/MS). The IMS methods are grouped into conventional, based on the absolute ion mobility, and differential or field asymmetric waveform IMS (FAIMS), based on the mobility difference in strong and weak electric fields. The key attraction of FAIMS is substantial orthogonality to MS, and several FAIMS/MS platforms have been commercialized. However, the utility of FAIMS had been constrained by limited resolving power, typically R ~ 10 - 20. Recently, the use of helium/nitrogen mixtures comprising up to 75% He has enabled R > 100, with broad resolution gains allowing separation of previously “co-eluting” isomers. These performance metrics open major new FAIMS applications in proteomic and other biological analyses. Here, we show that raising the separation field by ~35% over the previous 21 kV/cm provides similar or better resolution at 50% He, while avoiding problems due to elevated gas pressure in the MS manifold upon excessive He intake. In particular, a resolving power of >200 has been achieved for multiply-charged peptides. The field heating of ions under these conditions appears to exceed that at higher He content but weaker separation field, inducing greater izomerization of fragile species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accelerated High-Resolution Differential Ion Mobility Separations Using Hydrogen

The resolving power of differential ion mobility spectrometry (FAIMS) was dramatically increased recently by the introduction of carrier gases comprising up to 75% He or various vapors, enabling many new applications. However, the gains were often at the expense of analysis speed, in particular making high-resolution FAIMS incompatible with online liquid-phase separations. Here, we report FAIMS employing hydrogen, specifically in mixtures with N2 containing up to 98.4% H2. Such compositions raise the mobilities of all ions and thus resolving power, while avoiding the electrical breakdown inevitable in He-rich mixtures. The increases of resolving power and ensuing peak resolution are especially significant at the greatest H2 fractions - above {approx}80 - 90%. Higher resolution can be exchanged for acceleration of the analyses by up to {approx}20 times. For more mobile species such as multiply-charged peptides, this exchange is presently forced by the constraints of existing FAIMS devices, but future designs optimized for H2 should consistently improve resolution for all analytes.

08 HYDROGEN↗

Broad Separation of Isomeric Lipids by High-Resolution Differential Ion Mobility Spectrometry with Tandem Mass Spectrometry

Maturation of metabolomics has brought a deeper appreciation for the importance of isomeric identity of lipids to their biological role, mirroring that for proteoforms in proteomics. However, full characterization of the lipid isomerism has been thwarted by paucity of rapid and effective analytical tools. A novel approach is ion mobility spectrometry (IMS) and particularly differential or field asymmetric waveform IMS (FAIMS) at high electric fields, which is more orthogonal to mass spectrometry. Here we broadly explore the power of FAIMS to separate lipid isomers, and find a ~75% success rate across the four major types of glycero- and phospho- lipids (sn, chain length, double bond position, and cis/trans). The resolved isomers were identified using standards, and (for the first two types) tandem mass spectrometry. These results demonstrate the general merit of incorporating high-resolution FAIMS into lipidomic analyses. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrasensitive single-cell proteomics workflow identifies >1000 protein groups per mammalian cell

Here, we report on the combination of nanodroplet sample preparation, ultra-low-flow nanoLC, high-field asymmetric ion mobility spectrometry (FAIMS), and the latest-generation Orbitrap Eclipse Tribrid mass spectrometer for greatly improved single-cell proteome profiling. FAIMS effectively filtered out singly charged ions for more effective MS analysis of multiply charged peptides, resulting in an average of 1056 protein groups identified from single HeLa cells without MS1-level feature matching. This is 2.3 times more identifications than without FAIMS and a far greater level of proteome coverage for single mammalian cells than has been previously reported for a label-free study. Differential analysis of single microdissected motor neurons and interneurons from human spinal tissue indicated a similar level of proteome coverage, and the two subpopulations of cells were readily differentiated based on single-cell label-free quantification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pendular Proteins in Gases and New Avenues for Characterization of Macromolecules by Ion Mobility Spectrometry

Polar molecules align in electric fields when the dipole energy (proportional to field intensity E × dipole moment p) exceeds the thermal rotational energy. Small molecules have low p and align only at inordinately high E or upon extreme cooling. Many biomacromolecules and ions are strong permanent dipoles and may align at E achievable in gases and room temperature. The collision cross sections of aligned ions with gas molecules generally differ from orientationally averaged quantities, affecting ion mobilities measured in ion mobility spectrometry (IMS). Field asymmetric waveform IMS (FAIMS) separates ions by the difference between mobilities at high and low E and hence can resolve and identify macroion conformers based on the mobility difference between pendular and free rotor states. An exceptional sensitivity of that difference to the ion geometry and charge distribution holds the potential for a powerful new method for separation and characterization of macromolecular species. Theory predicts that the pendular alignment of ions in gases at any E requires a minimum p depending on the ion mobility, gas pressure, and temperature. At ambient conditions used in current FAIMS systems, the p for realistic ions must exceed ~300 - 400 Debye. The dipole moments of proteins statistically increase with increasing mass, and such values are typical above ~30 kDa. FAIMS analyses of protein ions and complexes of ~30 - 130 kDa show an order-of-magnitude expansion of separation space compared to smaller proteins and other ions, consistent with expectations for the dipole-aligned regime.

59 BASIC BIOLOGICAL SCIENCES↗