Search NASA⌕ Search

SEARCH · Search NASA

Results for “FIDASIM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Progress in modelling fast-ion D-alpha spectra and neutral particle analyzer fluxes using FIDASIM

FIDASIM is a code that models signals produced by charge-exchange reactions between neutrals and ions (both fast and thermal) in magnetically confined plasmas. With the ion distribution function as input, the code predicts the efflux to a neutral particle analyzer diagnostic and the photon radiance of Balmer-alpha light to a fast-ion D α diagnostic, in addition to many other related quantities. A new, parallelized version of the Monte Carlo code FIDASIM has been developed in Fortran90 that is substantially faster than the original interactive data language version. Modified algorithms include more accurate treatments of the time dependent collisional-radiative equations that describe neutral energy levels, of the cloud of ‘halo’ neutrals that surround the injected neutral beam, and of finite Larmor radius effects. Enhanced physics capabilities include modelling ‘passive’ signals from cold edge neutrals, the ability to treat general three-dimensional magnetic confinement configurations, and calculations of diagnostic-specific weight functions that enable tomographic reconstructions of the fast-ion distribution function. Neutral beam attenuation, beam emission, and fast-ion birth profiles are also modelled. Finally, the new algorithms have been successfully validated against experimental data and new features have been tested through benchmarks between two independently developed versions of the code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impurity transport studies at the HSX stellarator using active and passive CVI spectroscopy

The transport of carbon impurities has been studied in the helically symmetric stellarator experiment (HSX) using active and passive charge exchange recombination spectroscopy (CHERS). For the analysis of the CHERS signals, the STRAHL impurity transport code has been re-written in the python programming language and optimized for the application in stellarators. In addition, neutral hydrogen densities both along the NBI line of sight as well as for the background plasma have been calculated using the FIDASIM code. By using the basinhopping algorithm to minimize the difference between experimental and predicted active and passive signals, significant levels of impurity diffusion are observed. In this work, comparisons with neoclassical calculations from DKES/PENTA show that the inferred levels exceed the neoclassical transport by about a factor of four in the core and more than 100 times towards the plasma edge, thus indicating a high level of anomalous transport. This observation is in agreement with experimental heat diffusivites determined from a power balance analysis which exhibits strong anomalous transport as well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physics basis for the Wisconsin HTS Axisymmetric Mirror (WHAM)

The Wisconsin high-temperature superconductor axisymmetric mirror experiment (WHAM) will be a high-field platform for prototyping technologies, validating interchange stabilization techniques and benchmarking numerical code performance, enabling the next step up to reactor parameters. A detailed overview of the experimental apparatus and its various subsystems is presented. WHAM will use electron cyclotron heating to ionize and build a dense target plasma for neutral beam injection of fast ions, stabilized by edge-biased sheared flow. At 25 keV injection energies, charge exchange dominates over impact ionization and limits the effectiveness of neutral beam injection fuelling. This paper outlines an iterative technique for self-consistently predicting the neutral beam driven anisotropic ion distribution and its role in the finite beta equilibrium. Beginning with recent work by Egedal et al. ( Nucl. Fusion , vol. 62, no. 12, 2022, p. 126053) on the WHAM geometry, we detail how the FIDASIM code is used to model the charge exchange sources and sinks in the distribution function, and both are combined with an anisotropic magnetohydrodynamic equilibrium solver method to self-consistently reach an equilibrium. We compare this with recent results using the CQL3D code adapted for the mirror geometry, which includes the high-harmonic fast wave heating of fast ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radially resolved active charge exchange measurements of the hydrogenic isotope fraction on DIII-D

Radially resolved hydrogenic isotope fraction measurement capabilities have been developed for DIII-D using the main-ion charge exchange recombination (MICER) spectroscopy system in preparation for mixed hydrogen and deuterium experiments. Constraints on the hydrogenic ion temperatures and velocities based on measurements of the impurity ion properties are required to accurately fit the spectrum. Corrections for cross sectional distortions, spatial smearing due to the halo, and a neoclassical offset between the impurity and hydrogenic toroidal rotation are applied to the constraints prior to fitting the MICER spectrum. Extensive atomic physics calculations have been performed using the FIDASIM code, which has recently been improved to allow simulations using mixtures of hydrogenic species. Overall, these results demonstrate that for the same plasma parameters, the Dα emission is 20%–30% brighter than Hα due to differences in rate coefficients associated with the different ion thermal velocities for the same temperature and therefore must be taken into consideration when calculating absolute densities. However, despite these differences, the absolute error when estimating the hydrogen isotope fraction [n H /(n H + n D )] by using the Hα radiance fraction [L Hα /(L Hα + L Dα )] is typically less than 5% due to the way the fraction is formed, making the radiance fraction a reasonably accurate estimate of the isotope fraction for most cases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design study of an edge current density diagnostic using new high-performance single-channel beam emission spectrometers at DIII-D

A novel Motional Stark Effect spectroscopy system has been designed for application at the DIII-D tokamak. The system is optimized for studies of the poloidal and toroidal magnetic field in the plasma pedestal region with frame rates of up to 10 kHz. Further, light from an existing high-photon-throughput collection lens is analyzed using four single-channel f/2.8 Czerny–Turner spectrometers that use custom-made lens systems instead of mirrors. Each spectrometer has two separate outgoing legs and is operated in a positive grating order, which allows for simultaneous observations of D-alpha and D-beta spectra. Forward modeling using the code FIDASIM shows a radial resolution of the system close to 0.6 cm and sufficiently good spectral resolution when masking the high throughput light collection lens in the horizontal direction to avoid overly strong Doppler broadening of beam emission lines. Moreover, a detailed sensitivity study considering realistic levels of readout and photon noise shows that the poloidal and toroidal magnetic field strengths can be inferred with an uncertainty of less than 1%, which will allow the inference of changes of the plasma current during transient events.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Details of the neutral energy distribution and ionization source using spectrally resolved Balmer-alpha measurements on DIII-D

Spectrally resolved passive Balmer- α (D- α, H- α) measurements from the DIII-D 16 channel edge main-ion charge exchange recombination system confirm the presence of higher energy neutrals (“thermal” neutrals) in addition to the cold neutrals that recycle off the walls in the edge region of DIII-D plasmas. Charge exchange between thermal ions and edge neutrals transfers energy and momentum between the populations giving rise to thermal neutrals with energies approximating the ions in the pedestal region. Multiple charge exchange events in succession allow an electron to effectively take a random walk, transferring from ion to ion, providing a pathway of increasing energy and velocity, permitting a neutral to get deeper into the plasma before a final ionization event that contributes to the ion and electron particle fueling. Spectrally resolved measurements provide information about the density and velocity distribution of these neutrals, which has been historically valuable for validating Monte Carlo neutral models, which include the multi stage charge exchange dynamics. Here, in this study, a multi-channel set of such measurements is used to specifically isolate the details of the thermal neutrals that are responsible for fueling inside the pedestal top. Being able to separate the thermal from the cold emission overcomes several challenges associated with optical filter-based neutral density measurements. The neutral dynamics, deeper fueling by the thermal neutrals, and spectral measurement are modeled with the FIDASIM Monte Carlo collisional radiative code, which also produces synthetic spectra with a shape that is in close agreement with the measurements. By scaling the number of neutrals in the simulation to match the intensity of the thermal emission, we show it is possible to obtain local neutral densities and ionization source rates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Aligning the Thomson scattering and charge exchange recombination diagnostics using neutral beam emission at DIII-D

This work addresses discrepancies in the alignment of the H-mode pedestal profiles of the electron and ion properties in the DIII-D tokamak as measured by Thomson Scattering (TS) and Charge Exchange Recombination Spectroscopy (CER) diagnostics. While the alignment of these profiles is key for accurate studies of tokamak physics and plasma confinement, misalignments can occur due to inaccuracies, such as in magnetic equilibrium reconstructions required to map measurements in different poloidal and toroidal locations. Both FIDASIM, an established simulation package, and a simplified collisional radiative model are used to simulate neutral beam state densities and neutral beam emission. Simulated neutral beam emissions are calculated based on shifted TS profiles and compared to beam emission measurements from the Main Ion CER system to determine the best shift for aligning TS with CER. This analysis is performed on various DIII-D discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase-space sensitivity (weight functions) of 3 MeV proton diagnostics

Abstract The weight function W ( X ) is a diagnostic sensitivity to phase-space variables X that relates the measured signal C to the distribution function F ( X ) through the equation C = ∫ W ( X ) F ( X ) d X . In the present work, an algorithm to calculate W for a diagnostic that measures 3 MeV protons produced in d(d,p)t fusion reactions between a fast ion and a thermal deuteron is developed. The emitted protons escape the tokamak on curved orbits and are detected. These curved orbits constitute effective diagnostic ‘sightlines’. The presented algorithm accounts for the complications associated with these curved sightlines. An initial calculation of time-reversed proton orbits computes effective solid angles and sightlines for the relevant range of incident proton velocity vectors. These precomputed orbits are then used within the framework of FIDASIM (2020 Plasma Phys. Cont. Fusion 62 105008) to calculate the reactivity averaged over the thermal distribution of the ‘target’ deuterons and the probability that a fast ion of specified energy and pitch has a gyroangle that is consistent with the kinematic equations along each of the sightlines. Comparisons with analytic formulas and with independent calculations for the Mega Amp Spherical Tokamak 3 MeV proton diagnostic verify the algorithm.

Physics↗

Validating the simulation of beam-ion charge exchange in MAST Upgrade

Abstract Simulation of the impact of charge-exchange (CX) reactions on beam ions in the Mega Amp Spherical Tokamak (MAST) Upgrade was compared to measurements carried out with a fission chamber (neutron fluxes) and a fast ion deuterium-alpha (FIDA) diagnostic. A simple model was developed to reconstruct the outer-midplane neutral density based on measurements of deuterium-alpha emission from edge neutrals, and on Thomson scattering measurements of electron density and temperature. The main computational tools used were the ASCOT orbit-following code and the FIDASIM code for producing synthetic FIDA signals. The neutral density reconstruction agrees qualitatively with SOLPS-ITER modelling and yields a synthetic passive FIDA signal that is consistent with measurement. When CX losses of beam ions are accounted for, predicted neutron emission rates are quantitatively more consistent with measurement. It was necessary to account for CX losses of beam ions in simulations to reproduce the measured passive FIDA signal quantitatively and qualitatively. The results suggest that the neutral density reconstruction is a good approximation, that CX with edge neutrals causes significant beam-ion losses in MAST Upgrade, typically 20% of beam power, and that the ASCOT fast-ion CX model can be used to accurately predict the redistribution and loss of beam ions due to CX.

Physics↗

Resolving the fast ion distribution from imaging neutral particle analyzer measurements

A recently developed imaging neutral particle analyzer (INPA) on the DIII-D tokamak (Du 2018 Nucl. Fusion 58 082006) enables fast ion velocity-space tomography of high fidelity at the interrogated phase space. To accomplish this, the spatial and energy depending fast ( E < 80 keV) neutral flux towards the INPA stripping foils is calculated with FIDASIM and a newly developed code INPASIM simulates the INPA instrumental response to this neutral flux. Included in INPASIM is the neutral-foil interaction, the Larmor orbit tracing between the foil and the phosphor, the phosphor response to the incident ion flux as well as camera focusing. Benefiting from heavy, localized velocity-space weights and excellent signal to noise, computed tomography using the Ridge regression method is able to successfully reconstruct fine-scale velocity-space structures produced by multiple neutral beams separated by as small as ~3 keV in tests. Applying the inversion method to a sawtooth crash event reveals a significant profile flattening of confined passing particles across q = 1 flux surface, as well as a redistribution of fast ions into the trapped orbits at the plasma edge close to the last closed flux surface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗