TRP III Balance of Plant (BoP) Fire Alarm System Replacement (FASR) Kickoff Meeting – RFP 1793649 Awardee: Premier Fire & Security, Inc.
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The charge-flow transistor (CFT) and its applications for fire detection and gas sensing were investigated. The utility of various thin film polymers as possible sensing materials was determined. One polymer, PAPA, showed promise as a relative humidity sensor; two others, PFI and PSB, were found to be particularly suitable for fire detection. The behavior of the charge-flow capacitor, which is basically a parallel-plate capacitor with a polymer-filled gap in the metallic tip electrode, was successfully modeled as an RC transmission line. Prototype charge-flow transistors were fabricated and tested. The effective threshold voltage of this metal oxide semiconductor was found to be dependent on whether surface or bulk conduction in the thin film was dominant. Fire tests with a PFI-coated CFT indicate good sensitivity to smouldering fires.
The electrical resistivities were investigated of some polymers known to be enhanced by the presence of certain gases. This was done to make a device capable of providing early warning to fire through its response with the gases produced in the early phases of combustion. Eight polymers were investigated: poly(phenyl acetylene), poly(p-aminophenyl acetylene), poly(p-nitrophenyl acetylene), poly(p-formamidophenyl acetylene), poly(ethynyl ferrocene), poly(ethynyl carborane), poly(ethynyl pyridine), and the polymer made from 1,2,3,6 tetramethyl pyridazine. A total of 40 usable thin-film sandwich devices and a total of 70 usable interdigitated-electrode lock-and-key devices were fabricated. The sandwich devices were used for measurements of contact linearity, polymer conductivity, and polymer dielectric constant. The lock-and-key devices were used to determine the response of the polymers to a spectrum of gases that included ammonia, carbon nonoxide, carbon dioxide, sulfur dioxide, ethylene, acrolein, water vapor, and normal laboratory air. Strongest responses were to water vapor, ammonia, and acrolein, and depending on the polymer, weaker responses to carbon dioxide, sulfur dioxide, and carbon monoxide were observed. A quantitative theory of device operation, capable of accounting for observed device leakage current and sensitivity, was developed. A prototype detection/alarm system was designed and built for use in demonstrating sensor performance.
Conjugated polyacetylene polymers and one condensation polyene, all containing a high degree of conjugated unsaturation, were synthesized. These polymers were characterized by chemical analysis and by thermogravimetric analysis, as well as for their film-forming capability and gas/polymer interactions. It was found that those that had a high degree of conjugated unsaturation and had resonance - stabilizing groups were very thermally stable to 200 C, e.g., poly(dicyanoacetylene), poly(ethynylferrocene) and poly(phenylacetylene); while those with labile moieties, such as poly(p-formamidophenylacetylene), among others, suffered some degradation when heated in air. When subjected to gas/polymer interaction effects, the greatest change in electrical conductance was observed when ammonia was used as the gas and poly(p-nitrophenylacetylene) was the detector. Other polymers showed similar behavior. For example, poly(ethynylcarborane), considered to be an electron acceptor also showed a change in electrical conductance when exposed to ammonia, while poly(ethynylpyridine) and poly(ethylidenepyridazine) responded to carbon monoxide. However, for "fire gases" (gases from smoldering cotton), poly(ethynylferrocene) was the most responsive. Thus, the concept of polymers with different electronegativities forming charge-transfer complexes with different gases was found to be operable.
Portable detector tests rate-of-rise temperature devices. Incandescent light bulb is calibrated to produce rate of temperature rise necessary to activate properly functioning alarm.
Fire-detection systems incorporating multiple sensors that measure multiple parameters are being developed for use in storage depots, cargo bays of ships and aircraft, and other locations not amenable to frequent, direct visual inspection. These systems are intended to improve upon conventional smoke detectors, now used in such locations, that reliably detect fires but also frequently generate false alarms: for example, conventional smoke detectors based on the blockage of light by smoke particles are also affected by dust particles and water droplets and, thus, are often susceptible to false alarms. In contrast, by utilizing multiple parameters associated with fires, i.e. not only obscuration by smoke particles but also concentrations of multiple chemical species that are commonly generated in combustion, false alarms can be significantly decreased while still detecting fires as reliably as older smoke-detector systems do. The present development includes fabrication of sensors that have, variously, micrometer- or nanometer-sized features so that such multiple sensors can be integrated into arrays that have sizes, weights, and power demands smaller than those of older macroscopic sensors. The sensors include resistors, electrochemical cells, and Schottky diodes that exhibit different sensitivities to the various airborne chemicals of interest. In a system of this type, the sensor readings are digitized and processed by advanced signal-processing hardware and software to extract such chemical indications of fires as abnormally high concentrations of CO and CO2, possibly in combination with H2 and/or hydrocarbons. The system also includes a microelectromechanical systems (MEMS)-based particle detector and classifier device to increase the reliability of measurements of chemical species and particulates. In parallel research, software for modeling the evolution of a fire within an aircraft cargo bay has been developed. The model implemented in the software can describe the concentrations of chemical species and of particulate matter as functions of time. A system of the present developmental type and a conventional fire detector were tested under both fire and false-alarm conditions in a Federal Aviation Administration cargo-compartment- testing facility. Both systems consistently detected fires. However, the conventional fire detector consistently generated false alarms, whereas the developmental system did not generate any false alarms.
The design of the Skylab missions, 1973 to 1974, was intended to exclude any direct handling of hazardous, toxic, or reactive materials. The materials processing facility and multipurpose furnace provided a contained environment for conducting metals melting, brazing, sphere forming, and crystal growth experiments. At the end of the third mission, following the completion of all other experiments, the materials processing facility was used for a series of flammability experiments. The flammability tests were done last because of the contamination expected from the burning of the materials within the facility. The flammability tests demonstrated a number of peculiar effects that have implications for future design (fire detection, location, and suppression/control). Although the results of the flammability tests contain lessons appropriate to planning, a number of events during the flight illustrate situations or conditions that pose considerations beyond the commonly accepted range of concern for safety-related matters. This presentation includes a discussion of: Skylab flammability studies and the implications for fire suppression/control; false fire alarms and the Skylab fire detection system; space environmental effects on materials that are normally benign; spills/release of contaminants; the detrimental effect that the release of non-hazardous materials have on detection systems; and the problem of locating sources/originating point of hazards.
Carbon dioxide (CO2) is one of the major indicators of fire and therefore its measurement is very important for low-false-alarm fire detection and emissions monitoring. However, only a limited number of CO2 sensing materials exist due to the high chemical stability of CO2. In this work, a novel CO2 microsensor based on nanocrystalline tin oxide (SnO2) doped with copper oxide (CuO) has been successfully demonstrated. The CuO-SnO2 based CO2 microsensors are fabricated by means of microelectromechanical systems (MEMS) technology and sol-gel nanomaterial-synthesis processes. At a doping level of CuO: SnO2 = 1:8 (molar ratio), the resistance of the sensor has a linear response to CO2 concentrations for the range of 1 to 4 percent CO2 in air at 450 C. This approach has demonstrated the use of SnO2, typically used for the detection of reducing gases, in the detection of an oxidizing gas.
On January 13, 2005, at approximately 1355, smoke was noticed on the 4th floor of D Tower in the Vehicle Assembly Building (VAB). Subsequently, a 911 call was made, a fire alarm pull station was activated, and the VAB was evacuated. The source of the smoke was determined to be a fire on the Low Bay M/N section roof near the Launch Control Center (LCC) Crossover. Due to the high visibility of the mishap, the KSC Center Director appointed a Mishap Investigation Board. Damage to government property was limited to the roof and a small number of ceiling tiles that were damaged by the fire fighters during the response. At the time of the mishap, there were hazardous commodities in the VAB including Solid Rocket Motors (SRMs) with open grain due to Solid Rocket Booster (SRB) igniter inspections. The Board agrees with the SGS Fire Services' theory that large amounts of smoke concentrated in the VAB D Tower and moved downward into the cable tunnel. The Board determined the proximate cause of this incident to be torching. HRI was installing a torch applied roof membrane which resulted in the ignition of combustible materials under the membrane near a wooden roof expansion joint. The torch applied roofing method is a universally accepted safe industry practice when applied to non-combustible surfaces. The combination of an open flame torch and combustible materiaLs presents an increased level of risk even with skilled applicators. The addition of high winds to this combination results in a risk the Board thinks can not be adequately mitigated. An appropriate risk assessment and analysis must be performed on the proposed roofing method to be used on high visibility facilities which represent unique national assets even when using common industry practices for repair and modification. The Board identified three root causes which contributed to or created the proximate cause and, if eliminated or modified, would have prevented the mishap: 1. Combustible materials in existing roof system 2. Wind speed and direction 3. Inadequate fire watch technique. Two contributing factors were identified which may have contributed to the occurrence but, if eliminated or modified, would not have prevented the occurrence: 1. HRI rushed to dry in and seal the roof on January 13 because heavy rain was predicted for the next day 2. No guidance on torching in windy conditions A total of 17 significant observations were noted during this investigation, which could lead to another mishap, or increase the severity of a mishap, but were not contributing factors in this mishap.
I was managing the construction project, and I thought my biggest challenge was simply finishing the work in time for start of the holiday shopping season. The store opened three weeks before Thanksgiving. Everything looked great. Business picked up steadily as the serious spending season approached. Then, two days before Thanksgiving, disaster struck. The fire protection system was designed to prevent smoke and fire from reaching the merchandise. If a fire alarm went off anywhere in the building, the system went into a massive pressurization mode. Dampers would open and the system would pump in hundreds of cubic feet of air from outside into the store, pressurizing every square foot, preventing fire or smoke from spreading into the store. That night an unknown event tripped the alarm-and it sounded for six hours. The air conditioning system was still operational as the outside air temperatures had been warm all month. That night, however, temperatures plummeted to 20 degrees. With an alarm sounding in a building complex that covers many millions of square feet, no one paid attention to the cold air flowing into the space. Pipes froze and burst. Hundreds of gallons of water came down through the drywall, soaking merchandise, the carpet and the hardwood racks. This state of the art system, which had been designed to protect, was now responsible for unthinkable damage. You could be the among greatest project managers in world, but if you have an attitude and you give the client heartburn, unnecessary heartburn, you're not going to do more work with him. If you have a disaster like this one, and you manage to make everybody feel good and believe that you are going to take care of them, then everybody looks back on it and says, "You know what, this is a good project team; we work well together, so let's do another one."
A market survey was conducted regarding the commercialization potential and key market factors relevant to a tactile paging system for deaf-blind people. The purpose of the tactile paging system is to communicate to the deaf-blind people in an institutional environment. The system consists of a main console and individual satellite wrist units. The console emits three signals by telemetry to the wrist com (receiving unit) which will measure approximately 2 x 4 x 3/4 inches and will be fastened to the wrist by a strap. The three vibration signals are fire alarm, time period indication, and a third signal which will alert the wearer of the wrist com to the fact that the pin on the top of the wrist is emitting a morse coded message. The Morse code message can be felt and recognized with the finger.
A radio frequency paging communication system that has coded vibrotactile outputs suitable for use by deaf-blind people was developed. In concept, the system consists of a base station transmitting and receiving unit and many on-body transmitting and receiving units. The completed system has seven operating modes: fire alarm; time signal; repeated single character Morse code; manual Morse code; emergency aid request; operational status test; and message acknowledge. The on-body units can be addressed in three ways: all units; a group of units; or an individual unit. All the functions developed were integrated into a single package that can be worn on the user's wrist. The control portion of the on-body unit is implemented by a microcomputer. The microcomputer is packaged in a custom-designed hybrid circuit to reduce its physical size.
In June 1966, at the start of the Gulf Coast hurricane season, the Johnson Space Center (JSC) celebrated the opening of its new 4,000-square foot, state-of-the-art Emergency Operations Center (EOC). The new EOC has been upgraded and enhanced to support a wide spectrum of emergencies affecting JSC and neighboring communities. One of the main features of the EOC is its premier computerized dispatch center. The new system unites many of JSC's critical emergency functions into one integrated network. It automatically monitors fire alarms, security entrances, and external cameras. It contains the JSC inventory of hazardous materials, by building and room, and can call up Material Safety Data Sheets for most of the generic hazardous materials used on-site. The EOC is available for community use during area emergencies such as hurricanes and is a welcome addition to the Clear Lake/Galveston Bay Area communities' emergency response resources.
Numerous aerospace applications, including low-false-alarm fire detection, environmental monitoring, fuel leak detection, and engine emission monitoring, would benefit greatly from robust and low weight, cost, and power consumption chemical microsensors. NASA Glenn Research Center has been working to develop a variety of chemical microsensors with these attributes to address the aforementioned applications. Chemical microsensors using different material platforms and sensing mechanisms have been produced. Approaches using electrochemical cells, resistors, and Schottky diode platforms, combined with nano-based materials, high temperature solid electrolytes, and room temperature polymer electrolytes have been realized to enable different types of microsensors. By understanding the application needs and chemical gas species to be detected, sensing materials and unique microfabrication processes were selected and applied. The chemical microsensors were designed utilizing simple structures and the least number of microfabrication processes possible, while maintaining high yield and low cost. In this presentation, an overview of carbon dioxide (CO2), oxygen (O2), and hydrogen/hydrocarbons (H2/CxHy) microsensors and their fabrication, testing results, and applications will be described. Particular challenges associated with improving the H2/CxHy microsensor contact wire-bonding pad will be discussed. These microsensors represent our research approach and serve as major tools as we expand our sensor development toolbox. Our ultimate goal is to develop robust chemical microsensor systems for aerospace and commercial applications.
A fire on-board the International Space Station (ISS) resulting from a commercial Surface Pro tablet Lithium-Ion (Li-ion) battery can be detrimental to the spacercraft and the astronauts. The Spacecraft Fire Safety Demonstration (Saffire) program is focused on identifying and quantifying the risks that potentially arise inside a space vehicle by conducting large fire experiments inside the Cygnus cargo vehicle upon re-entry to Earth. The potential candidate that will be flown on the ISS is a 4- cell Li-ion battery pack Surface Pro tablet (42 Wh). The tablets were tested at the White Sands Test Facility (WSTF) using a localized heating method to emulate the failing mechanism that leads the unit into thermal runaway. Measurements inside the test chamber were performed on aerosol mass concentrations and for specific toxic products (i.e. from CO, HCN, HCl and CO2). These toxic products depend on the size of the fire and energy content of the tablet. Comparisons will be made with the Dell XPS (97 Wh). The concentrations are then used to extrapolate to laptop fires on a vehicle at the approximate volumetric size of the Orion spacecraft. The presentation provides an analysis on the detection capability and the response time to trigger fire alarms aboard a vehicle by using the mass concentration levels. These results will consider the rate at which the life support system is able to filter the atmosphere in order to provide a hazardous free environment.
Various methods for preventing fires in airplanes are presented with most efforts centering around prevention of backfires, new engine and carburetor designs, as well as investigations on different types of fuels.
Fire protection of critical space assets, including launch and fueling facilities and manned flight hardware, demands automatic sensors for continuous monitoring, and in certain high-threat areas, fast-reacting automatic suppression systems. Perhaps the most essential characteristic for these fire detection and suppression systems is high reliability; in other words, fire detectors should alarm only on actual fires and not be falsely activated by extraneous sources. Existing types of fire detectors have been greatly improved in the past decade; however, fundamental limitations of their method of operation leaves open a significant possibility of false alarms and restricts their usefulness. At the Civil Engineering Laboratory at Tyndall Air Force Base in Florida, a new type of fire detector is under development which 'sees' a fire visually, like a human being, and makes a reliable decision based on known visual characteristics of flames. Hardware prototypes of the Machine Vision (MV) Fire Detection System have undergone live fire tests and demonstrated extremely high accuracy in discriminating actual fires from false alarm sources. In fact, this technology promises to virtually eliminate false activations. This detector could be used to monitor fueling facilities, launch towers, clean rooms, and other high-value and high-risk areas. Applications can extend to space station and in-flight shuttle operations as well; fiber optics and remote camera heads enable the system to see around obstructed areas and crew compartments. The capability of the technology to distinguish fires means that fire detection can be provided even during maintenance operations, such as welding.
Closed-circuit television is superior to conventional smoke or heat sensors for detecting fires in large open spaces. Single TV camera scans entire area, whereas many conventional sensors and maze of interconnecting wiring might be required to get same coverage. Camera is monitored by person who would trip alarm if fire were detected, or electronic circuitry could process camera signal for fully-automatic alarm system.