Search NASA⌕ Search

SEARCH · Search NASA

Results for “FIRE ALARMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Radiation Effects on Line Heat Detection Cable AP Hot Cells Fire Detection at Brookhaven National Laboratory

Hot cells are used to safely shield workers from high radiation environments while allowing a process to take place within the cell's shielded enclosure, often with the assistance of remote manipulators. The interior of a cell may not be accessible by personnel for years at a time, either due to the lingering radiation environment or due to the constant use of these specialized pieces of equipment. High radiation levels are known to cause undesirable effects and changes to different materials in varying degrees. Selecting equipment for a radiation environment requires an evaluation of materials used (preferably completed assembles), to ensure all interactions of materials are known and ensure that the equipment will have a high degree of reliability and functionality over the intended life of the facility. Hot cells contain systems to support the primary purpose of the enclosure. Fire detection is one such support system. Safety of hot cell operations often establish limits on the amounts of combustibles with the cells, but the presence of some combustible materials is unavoidable. Fire detection is provided to quickly detect a fire and summon manual intervention before damage is too great. Detection may also be used to initiate fire suppression systems. As a safety system, fire detection needs to remain functional to protect the facility throughout the facility's life. Equally important is that the false alarms from the fire detection are minimized to retain confidence in the alarm system and avoid unnecessary interruptions in the hot cell operations. There are many types of fire detection available with various pros and cons. Not all types of fire detection are suited for hot cell application.

36 MATERIALS SCIENCE↗

Shooter Alarm System Final Report FY23

Lawrence Livermore National Laboratory (LLNL) is developing a multiphysics sensor package for automatic live arms fire detection for use in schools, houses of worship, hospi tals, etc. The goal is to have a package the size of a common smoke or CO2 detector with a price point of $50 or less which may be deployed throughout the aforementioned facilities. The commercial device will detect live gun fire with low probability of false alarm and auto matically alert first responders. A prototype board with four accelerometers, two infrared (IR) and two microphones has been developed and deployed at two experiments at LLNL’s Small Firearms Training Facility (SFTF). The device successfully and consistently measured signals on the accelerometer and acoustic channels. IR responses were measured depending upon the environment and sound source.

42 ENGINEERING↗

Climate regime shift and forest loss amplify fire in Amazonian forests

Frequent Amazonian fires over the last decade have raised the alarm about the fate of the Earth's most biodiverse forest. The increased fire frequency has been attributed to altered hydrological cycles. However, observations over the past few decades have demonstrated hydrological changes that may have opposing impacts on fire, including higher basin-wide precipitation and increased drought frequency and severity. Here, we use multiple satellite observations and climate reanalysis datasets to demonstrate compelling evidence of increased fire susceptibility in response to climate regime shifts across Amazonia. In this work, we show that accumulated forest loss since 2000 warmed and dried the lower atmosphere, which reduced moisture recycling and resulted in increased drought extent and severity, and subsequent fire. Extremely dry and wet events accompanied with hot days have been more frequent in Amazonia due to climate shift and forest loss. Simultaneously, intensified water vapor transport from the tropical Pacific and Atlantic increased high-altitude atmospheric humidity and heavy rainfall events, but those events did not alleviate severe and long-lasting droughts. Amazonia fire risk is most significant in the southeastern region where tropical savannas undergo long seasonally dry periods. We also find that fires have been expanding through the wet-dry transition season and northward to savanna-forest transition and tropical seasonal forest regions in response to increased forest loss at the "Arc of Deforestation." Tropical forests, which have adapted to historically moist conditions, are less resilient and easily tip into an alternative state. Our results imply forest conservation and fire protection options to reduce the stress from positive feedback between forest loss, climate change, and fire.

54 ENVIRONMENTAL SCIENCES↗

Optimal Frequency-domain Analysis for Spacecraft Time Series: Introducing the Missing-data Multitaper Power Spectrum Estimator

While the Lomb–Scargle periodogram is foundational to astronomy, it has a significant shortcoming: the variance in the estimated power spectrum does not decrease as more data are acquired. Statisticians have a 60 yr history of developing variance-suppressing power spectrum estimators, but most are not used in astronomy because they are formulated for time series with uniform observing cadence and without seasonal or daily gaps. Here we demonstrate how to apply the missing-data multitaper power spectrum estimator to spacecraft data with uniform time intervals between observations but missing data during thruster fires or momentum dumps. The F-test for harmonic components may be applied to multitaper power spectrum estimates to identify statistically significant oscillations that would not rise above a white noise–based false alarm probability. Multitapering improves the dynamic range of the power spectrum estimate and suppresses spectral window artifacts. We show that the multitaper–F-test combination applied to Kepler observations of KIC 6102338 detects differential rotation without requiring iterative sinusoid fitting and subtraction. Significant signals reside at harmonics of both fundamental rotation frequencies and suggest an antisolar rotation profile. Next we use the missing-data multitaper power spectrum estimator to identify the oscillation modes responsible for the complex "scallop-shell" shape of the K2 light curve of EPIC 203354381. We argue that multitaper power spectrum estimators should be used for all time series with regular observing cadence.

79 ASTRONOMY AND ASTROPHYSICS↗

Leak detection in a subcritical boiler

Thermal power plants experience cycling duty leading to the fatigue of the boiler and heat exchanger tubes. As a result, tube failures occur frequently in coal fired fleets leading to forced outages. Furthermore, because the tube leaks have been the major source of unwanted shutdowns and the number of outages is increasing, present work focuses on the detection and isolation of the leak in a subcritical boiler based upon the process data from a commercial coalfired power plant. The mass balance equation around the steam drum was analyzed using timeseries data collected from a 300 MW power plant. The ratio of the feed water mass flow rate to the steam mass flow rate was defined as a key parameter for detecting leaks. The difference in slope between the feedwater and steam mass flow rate during the normal and faulty operations was established as the upper control limit for real time monitoring. To reduce false alarm rates that arise when raw signal is directly compared against the threshold due to common process fluctuations, an optimal filter was derived for smoothing. It was found that the optimal filter reacted much more quickly to process changes than an exponential moving average filter, around 8 h earlier on average. Occurrence of relatively high false alarm rates even in the filtered responses was related to the cycling of the boiler from the base load condition. Variable threshold was established to keep false alarm rates to the minimum while maintaining the leak detection rate. Finally, the leak was located at the economizer and this could readily be isolated by investigating the magnitude of the mass flow rates ratio and the temperature at the economizer outlet.

42 ENGINEERING↗

Scaling Up: Demonstrating Risk Reduction and Cost Compression for Commercial Heat Pump Water Heaters - CRADA 625 (Abstract)

Commercial heat pump water heater (CHPWH) systems significantly decarbonize the commercial and multifamily sectors by eliminating the reliance on gas-fired water heating. CHPWH systems are also well suited to include load shift controls that enable load-up and shed commands for supporting grid reliability and time-of-use pricing structure. However, they have not had wide adoption due to factors including price, complexity, and perceived risk. Although CHPWHs have been available in the US for decades, they have not made significant market gains in part because the systems have required significant and costly engineering design expertise and proved lackluster performance. Successful widespread market adoption requires a different approach; a shift from the current custom specialized expertise project design and installation to a repeatable approach that requires little specialized knowledge or expertise and can deliver persistent performance. Using this type of holistic systems approach requires effectively integrating four CHPWH system key components: primary air-to-water heat pumps; primary thermal storage tanks, a temperature maintenance system, and a control system which has capabilities to manage the primary heat pump cycles, any back-up, supplemental, or temperature maintenance heating, alarms, and grid connectivity allowing for demand response (DR), and/or load shifting. The project team has developed and will implement a suite of tools to support faster, less expensive, and more reliable field installations of CHPWH technology and with the resulting data used to further improve the tool set. These tools include: (1) A tool for optimizing system size and costs. (2) A tool that predicts annual energy use and overall system efficiency. (3) The Advanced Water Heater Specification (AWHS 8.0) defining the components of a full CHPWH system addressing performance requirements by climate zone. (4) The Qualified Products List: (QPL) of approved products that meet the specifications requirements. (5) Training materials including online on-demand modules, instructor-led training, and virtual interactive video tours of CHPWH installations in multifamily buildings. Demonstration site identification in low-income buildings in underserved communities is currently underway. Preliminarily, the team anticipates having three demonstrations in the Pacific Northwest and three in the Northeast for a total of six sites. After the demonstration sites are finalized, and M&V instrumentation installations are complete, the team will gather performance data and confirm whether the CHPWH systems perform as predicted and use the data to improve the existing tools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗