Search NASA⌕ Search

SEARCH · Search NASA

Results for “FIRE HAZARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The Elimination of Fire Hazard Due to Back Fires

A critical study was made of the operation of a type of back-fire arrester used to reduce the fire hazard of aircraft engines. A flame arrester consisting of a pack or plug of alternate flat and corrugated plates of thin metal was installed in the intake pipe of a gasoline engines; an auxiliary spark plug inserted in the intake manifold permitted the production of artificial back fires at will. It was found possible to design a plug which prevented all back fires from reaching the carburetor.

Theodorsen, Theodore↗

Evaluating FRI3D for Cost Savings in Fire Hazard Analysis at DOE Sites

A fire hazard analysis, required for many U.S. Department of Energy (DOE) facilities, is a complex, cumbersome, and costly process. Fire hazard analyses may be viewed as a checkbox, but ideally and in spirit with the DOE-STD-1066, the fire hazard analysis (FHA) should be a part of the workflow and used to help in modifications, maintenance, and improving operational safety. With current FHA development processes, it is both time and cost prohibitive for true integration. A tool called Fire Risk Investigation in 3D or FRI3D was developed under the DOE Light Water Reactor Sustainability program to simplify and automate many aspects of a fire probabilistic risk analysis for existing nuclear power plants. The FRI3D tool automates fire scenarios by combining approved fire simulation codes, U.S. Nuclear Regulatory Commission fire calculations methods, 3D modeling and visualization, and probabilistic risk analysis models into a single workflow supported with a user interface. FRI3D was initially designed for used in combination with a PRA, this case study, evaluated using FRI3D for a plant modification, determined the benefits that detailed fire modeling can have for U.S. Department of Energy facilities with or without a PRA model. It also looked at what tasks from DOE requirements could be reduced using the tool and what is needed to integrate fire hazard analysis into site workflow.

97 - MATHEMATICS AND COMPUTING↗

Chaparral vegetation reflectance and its potential utility for assessment of fire hazard

Current methods for assessment of ignition potential often fail to alert wildland managers to the severity of drought-induced fire hazard at remote locations and over large geographic areas. After the severe fires of 1988 in the western United States, the need was heightened for improved fire hazard assessment techniques. Chaparral vegetation is particularly receptive to recurring drought-related episodes of extreme fire hazard and was thus chosen for study here. Demonstrated herein is that chaparral vegetation has considerably different reflecting properties at different levels of drought stress. As such, remote sensing may have utility for fire hazard assessment in this vegetation type.

Cohen, Warren B.↗

An evaluation of the relative fire hazards of jet A and jet B for commercial flight

The relative fire hazards of Jet A and Jet B aircraft fuels are evaluated. The evaluation is based on a consideration of the presence of and/or the generation of flammable mixtures in fuel systems, the ignition characteristics, and the flame propagation rates for the two fuel types. Three distinct aircraft operating regimes where fuel type may be a factor in fire hazards are considered. These are: (1) ground handling and refueling, (2) flight, and (3) crash. The evaluation indicates that the overall fire hazards for Jet A are less than for Jet B fuel.

Hibbard, R. R.↗

An assessment of the crash fire hazard of liquid hydrogen fueled aircraft

The crash fire hazards of liquid hydrogen fueled aircraft relative to those of mission equivalent aircraft fueled either with conventional fuel or with liquefied methane were evaluated. The aircraft evaluated were based on Lockheed Corporation design for 400 passenger, Mach 0.85, 5500 n. mile aircraft. Four crash scenarios were considered ranging from a minor incident causing some loss of fuel system integrity to a catastrophic crash. Major tasks included a review of hazardous properties of the alternate fuels and of historic crash fire data; a comparative hazard evluation for each of the three fuels under four crash scenarios a comprehensive review and analysis and an identification of areas further development work. The conclusion was that the crash fire hazards are not significantly different when compared in general for the three fuels, although some fuels showed minor advantages in one respect or another.

Source record↗

ERTS-1 imagery and high flight photographs as aids to fire hazard appraisal at the NASA San Pablo Reservoir test site

The identification of fire hazards at the San Pablo Reservoir Test Site in California using ERTS-1 data is discussed. It is stated that the two primary fire hazards in the area are caused by wild oat plants and eucalyptus trees. The types of imagery used in conducting the study are reported. Aerial photographs of specific areas are included to show the extent of the fire hazards.

Colwell, R. N.↗

Fire hazard considerations for composites in vehicle design

Military ground vehicles fires are a significant cause of system loss, equipment damage, and crew injury in both combat and non-combat situations. During combat, the ability to successfully fight an internal fire, without losing fighting and mobility capabilities, is often the key to crew survival and mission success. In addition to enemy hits in combat, vehicle fires are initiated by electrical system failures, fuel line leaks, munitions mishaps and improper personnel actions. If not controlled, such fires can spread to other areas of the vehicle, causing extensive damage and the potential for personnel injury and death. The inherent fire safety characteristics (i.e. ignitability, compartments of these vehicles play a major roll in determining rather a newly started fire becomes a fizzle or a catastrophe. This paper addresses a systems approach to assuring optimum vehicle fire safety during the design phase of complex vehicle systems utilizing extensive uses of composites, plastic and related materials. It provides practical means for defining the potential fire hazard risks during a conceptual design phase, and criteria for the selection of composite materials based on its fire safety characteristics.

Gordon, Rex B.↗

A Study of Aircraft Fire Hazards Related to Natural Electrical Phenomena

The problems of natural electrical phenomena as a fire hazard to aircraft are evaluated. Assessment of the hazard is made over the range of low level electrical discharges, such as static sparks, to high level discharges, such as lightning strikes to aircraft. In addition, some fundamental work is presented on the problem of flame propagation in aircraft fuel vent systems. This study consists of a laboratory investigation in five parts: (1) a study of the ignition energies and flame propagation rates of kerosene-air and JP-6-air foams, (2) a study of the rate of flame propagation of n-heptane, n-octane, n-nonane, and n-decane in aircraft vent ducts, (3) a study of the damage to aluminum, titanium, and stainless steel aircraft skin materials by lightning strikes, (4) a study of fuel ignition by lightning strikes to aircraft skins, and (5) a study of lightning induced flame propagation in an aircraft vent system.

Kester, Frank L.↗

Wire-break Ignition Testing of Materials for Spacesuit Fire Hazard Control

The input design constraints applied to the extravehicular activity (EVA) spacesuit pose a significant challenge for mitigation of fire hazards. To minimize fatigue and increase comfort of the crewmember operating the suit, the suit pressure is lowered below sea level conditions with typical EVA suit designs operating with 4.3 psia (29.7 kPa). With the lowered operating pressures and the use of closed-loop life support, the suit requires elevated concentrations of oxygen, typically >95%. At these oxygen concentrations, nearly the entirety of the suit internal materials are flammable. This leaves one remaining possible control leg of the fire triangle: ignition sources. Since the Gemini and Apollo programs, this has been a risk that has undergone constant reassessment, with a focus on improved mitigation. After the Apollo I fire, an arc ignition method was developed and used to quantify ignition thresholds for in-suit materials resulting in a current limit for powered in-suit devices applied to all subsequent suit designs. After the discovery of a frayed spacesuit biomed cable on STS-113 during the Shuttle Program, the previous arcing method was repeated with additional methods developed to extend the testing further. One of those methods was wire-break ignition testing, in which the current in a single strand of wire was progressively increased, preheating the material in proximity with a resultant break and the application of a reasonably repeatable arc to ignite the material, all while exposed in the selected environment. This method was used to test a suite of spacesuit materials providing relative performance with respect to ignition with this configuration for application of energy. This paper discusses extension of the current data set to address recent material additions, lowering of energy test levels for quantification of materials too low to measure in previous testing, as well as future plans to improve this method.

Colin Campbell↗

Effects of Atmospheric Environment on Electrical Fire Hazards

In general, the problem of electrical fires involves the ignition and flammability parameters relating to the metallic conductor as well as to the insulating materials. The recent study of Klein has approached the problem by using three basic tests: (1) Determining the amount of current that causes wire to burn in various atmospheres, (2) measuring the effect of various atmospheres in propagating flame from a shorted wire to adjacent wires, and (3) measuring the effect of various atmospheres when extreme current is passed through wire.

Roth, Emanuel M.↗

Technique for assessing potential fire hazards

Combustion hazard modeling technique limits the fire evaluation to a description of only thermal energy exchanges which are involved in the burning process, and the calculation of temperatures, temperature changes, and weight losses as a result of these energy changes.

Lampert, H. M.↗

Cables and fire hazards

Besides describing the experiments conducted to develop a nonflammable cable, this article discusses several considerations regarding other hazards which might result from cable fires, particularly the toxicity and opacity of the fumes emitted by the burning cable. In addition, this article examines the effects of using the Oxygen Index as a gauge of quality control during manufacture.

Zanelli, C.↗