Search NASA⌕ Search

SEARCH · Search NASA

Results for “FIRE mode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

On FIRE mode in KSTAR

We report on the status of Fast Ion Regulated Enhancement (FIRE) mode experiments in the Korea Superconducting Tokamak Advanced Research. This regime is being developed for high-performance, steady-state operation which features a stationary ion internal transport barrier, enabling a central ion temperature approaching 10 keV to be sustained for up to 50 s, without the need for delicate profile control and with no significant impurity accumulation. As its key novelty lies in the significant contribution of fast ions that stabilize core turbulence, the regime has been named FIRE mode. To achieve this regime, neutral beam injection is applied at moderate power levels near the L–H power threshold, while maintaining low plasma density to avoid the L–H transition. The scenario is typically established in diverted magnetic configurations. The core features of FIRE mode were investigated through power balance analysis and fluctuation measurements, revealing a clear transport bifurcation in the ion channel. At the plasma edge, FIRE mode occasionally exhibits I-mode characteristics, particularly in unfavorable magnetic null configurations with q 95 ∼ 4, including the presence of weakly coherent modes. In terms of MHD activity, sawtooth oscillations are observed but appear to be stabilized during the high-performance phase. Fast ion-driven Alfvénic eigenmodes (AEs), indicated by strong frequency chirping near 200 kHz, are also observed. Additionally, lower-frequency MHD activities, distinct from the fast ion-driven AEs, are present and have some influence on plasma performance. The enhancement of core confinement is primarily attributed to fast ion effects, which were evaluated with respect to dilution, alpha stabilization, and resonant interactions with turbulence using gyrokinetic analyses. Among these, the dilution effect was found to be the most dominant. The characteristics of FIRE mode were compared with those of other hot ion plasma scenarios, such as supershot and hot ion mode. While they share many similarities, FIRE mode is distinguished by the accessibility to conditions with T i ≈ T e , presence of I-mode edge features, and its long-duration sustainment. Predictive simulations of FIRE mode were performed using integrated transport modeling with TRIASSIC, employing the TGLF anomalous transport model. These simulations confirmed the critical role of fast ions in achieving this regime. The future prospect of FIRE mode for application in fusion reactors is discussed, with an emphasis on possibly extending the regime to higher density operation.

FIRE mode↗

On how fast ions enhance the regulation of drift wave turbulence by zonal flows

Abstract This paper presents a mechanism for enhanced regulation of drift wave turbulence by zonal flows in the presence of a fast ion population. It demonstrates that dilution effects due to the energetic particles (EPs) have a far-reaching impact on all aspects of the nonlinear dynamics. The modulational growth of zonal flow shear and the corresponding evolution of drift wave energy are calculated with dilution effects. The coupled zonal flow growth and drift wave energy equations are reduced to a predator–prey model. This is solved for the fixed points, which represents the various states of the system. Results display a strong dependence on dilution, which leads to greatly reduced levels of saturated turbulence and transport. Implications for the FIRE mode plasma of KSTAR are discussed in detail. This model is perhaps the simplest dynamical one which captures the beneficial effects of EPs on confinement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of the KSTAR experiments toward fusion reactor

The Korean Superconducting Tokamak Advanced Research has been focused on exploring the key physics and engineering issues for future fusion reactors by demonstrating the long pulse operation of high beta steady-state discharge. Advanced scenarios are being developed with the goal for steady-state operation, and significant progress has been made in high ℓ i , hybrid and high beta scenarios with β N of 3. In the new operation scenario called fast ion regulated enhanced (FIRE), fast ions play an essential role in confinement enhancement. GK simulations show a significant reduction of the thermal energy flux when the thermal ion fraction decreases and the main ion density gradient is reversed by the fast ions in FIRE mode. Optimization of 3D magnetic field techniques, including adaptive control and real-time machine learning control algorithm, enabled long-pulse operation and high-performance ELM-suppressed discharge. Symmetric multiple shattered pellet injections (SPIs) and real-time disruption event characterization and forecasting are being performed to mitigate and avoid the disruptions associated with high-performance, long-pulse ITER-like scenarios. Finally, the near-term research plan will be addressed with the actively cooled tungsten divertor, a major upgrade of the NBI and helicon current drive heating, and transition to a full metallic wall.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photovoltaic Cable Connectors: A Comparative Assessment of the Present State of the Industry

The consequences of failure for balance-of-systems components (such as photovoltaic (PV) cable connectors) include offline module string(s); low system voltage; arc, ground, insulation, and overtemperature faults; triggered fuse(s); system shutdown; and fire. The degradation modes for connectors are studied here through an industry survey and its subsequent examination, which are compared with field-degraded specimens. A total of 117 specimens were obtained from a variety of locations and climates or accelerated tests. A failure analysis for connectors from PV installations was developed (and applied to 54 specimens), including nondestructive examinations (photography, a custom resistance-current scan, and X-ray computed tomography) and destructive examinations (featuring milling of the external plastic, extraction of the internal convolute spring, and potting and polishing in cross section). Surface and through-thickness composition of the metal pins and springs was quantified using scanning electron microscopy with energy-dispersive X-ray spectroscopy. Fourier transform infrared spectroscopy was used to verify the base polymer materials and compare the chemical structure of the connector body, bushing, end nut, and o-ring. Thermogravimetric analysis and differential scanning calorimetry were used to further verify the degradation of the same polymeric components.

cable connectors↗

Photovoltaic Cable Connectors: A Comparative Assessment of the Present State of the Industry [Slides]

The consequences of failure for balance of systems (BoS) components (such as PV cable connectors) include offline module string(s); low system voltage; arc, ground, insulation, and over-temperature faults; triggered fuse(s); system shutdown; and fire. The degradation modes for connectors are studied here through an industry survey and its subsequent examination, which are compared to field-degraded specimens. 117 specimens were obtained from a variety of locations and climates or accelerated tests. A failure analysis for connectors from PV installations was developed (and applied to 54 specimens) including nondestructive examinations (photography, a custom resistance-current scan, and X-ray computed tomography) and destructive examinations (featuring milling of the external plastic, extraction of the internal convolute spring, and potting and polishing in cross-section). Surface and through-thickness composition of the metal pins and springs was quantified using scanning electron microscopy with energy-dispersive X-ray spectroscopy. Fourier-transform infrared spectroscopy was used to verify the base polymer materials and compare the chemical structure of the connector body, bushing, end nut, and o-ring. Thermogravimetric analysis and differential scanning calorimetry were used to further verify the degradation of the same polymeric components. Updated from 2023 NIST/UL Workshop on Photovoltaic Materials Durability (website: https://events.ul.com/WPMogn?rt=aAuoWsl4E0KaORLCMeOgfA) and 2024 PVRW workshop (https://pvrw.nrel.gov/past-proceedings).

14 SOLAR ENERGY↗

Solid particulate mass and number from ducted fuel injection in an optically accessible diesel engine in skip-fired operation

Ducted fuel injection (DFI) is a new combustion strategy that has been shown to significantly attenuate soot formation in diesel engines. While previous studies have used optical diagnostics and optical filter smoke number methods to show that DFI reduces in-cylinder soot formation and engine-out soot emissions, respectively, this is the first study to measure solid particle number (PN) emissions in addition to particle mass (PM). Furthermore, this study quantitatively evaluates the use of transient particle instruments for measuring particles from skip-fired operation in an optical single cylinder research engine (SCRE). Engine-out PN was measured using an engine exhaust particle sizer following a catalytic stripper, and PM was measured using a photoacoustic analyzer. The study improves on earlier preliminary emissions studies by clearly showing that DFI reduces overall PM by 76%–79% and PN for particles larger than 23 nm by 77% relative to conventional diesel combustion at a 1200-rpm, 13.3-bar gross indicated mean effective pressure operating condition. The degree of engine-out PM reduction with DFI was similar across both particulate measurement instruments used in the work. Through the use of bimodal distribution fitting, DFI was also shown to reduce the geometric mean diameter of accumulation mode particles by 26%, similar to the effects of increased injection pressure in conventional diesel combustion systems. This work clearly shows the significant solid particulate matter reductions enabled by DFI while also demonstrating that engine-out PN can be accurately measured from an optical SCRE operating in a skip-fired mode. Based on these results, it is believed that DFI has the potential to enable fuel savings when implemented in multi-cylinder engines, both by lowering the required frequency of active diesel particulate filter regeneration, and by reducing the backpressure imposed by exhaust filtration systems.

33 ADVANCED PROPULSION SYSTEMS↗

Spatiotemporal flame propagations, combustion and solid particle emissions from lean and stoichiometric gasoline direct injection engine operation

Increased particle number and mass emissions in gasoline direct injection (GDI) engines should require to investigate in-cylinder flame and combustion characteristics associated with primary source of particle emissions. In this article, in-cylinder spatiotemporal flame luminosity is quantitatively characterized to features combustion process and solid particle emissions from a GDI engine operating in two lean and one stoichiometric modes. Low- and high-steady state operating points were used to compare combustion strategies on flame development and emission characteristics. A fiber-optic sensor composed of eight measurement channels detected the flame front and the direction of the flame propagation in the combustion chamber. Solid particle emissions in the exhaust were measured using an engine exhaust particle sizer and a micro soot sensor. Results of the experiments showed that two lean combustion modes by injection strategies resulted in distinct combustion and flame development. Lean combustion modes generated high diffusion flame by burning stratified rich-mixture. Although the lean cases resulted in strong diffusion flames, the lean-homogeneous produced similar particle size distributions with the stoichiometric mode with high ash particles. Piston pool fires on the piston surface in the lean-stratified mode induced a large accumulation mode with high particle mass concentrations.

42 ENGINEERING↗

Analysis of Fire-Induced Circulations during the FireFlux2 Experiment

Despite recent advances in both coupled fire modeling and measurement techniques to sample the fire environment, the fire–atmosphere coupling mechanisms that lead to fast propagating wildfires remain poorly understood. This knowledge gap adversely affects fire management when wildland fires propagate unexpectedly rapidly and shift direction due to the fire impacts on local wind conditions. In this work, we utilized observational data from the FireFlux2 prescribed burn and numerical simulations performed with a coupled fire–atmosphere model WRF-SFIRE to assess the small-scale impacts of fire on local micrometeorology under moderate wind conditions (10–12 m/s). The FireFlux2 prescribed burn provided a comprehensive observational dataset with in situ meteorological observations as well as IR measurements of fire progression. To directly quantify the effects of fire–atmosphere interactions, two WRF-SFIRE simulations were executed. One simulation was run in a two-way coupled mode in which the heat and moisture fluxes emitted from the fire were injected into the atmosphere, and the other simulation was performed in a one-way coupled mode for which the atmosphere was not affected by the fire. The difference between these two simulations was used to analyze and quantify the fire impacts on the atmospheric circulation at different sections of the fire front. The fire-released heat fluxes resulted in vertical velocities as high as 10.8 m/s at the highest measurement level (20 m above ground level) gradually diminishing with height and dropping to 7.9 m/s at 5.77 m. The fire-induced horizontal winds indicated the strongest fire-induced flow at the lowest measurement levels (as high as 3.3 m/s) gradually decreasing to less than 1 m/s at 20 m above ground level. The analysis of the simulated flow indicates significant differences between the fire-induced circulation at the fire head and on the flanks. The fire-induced circulation was much stronger near the fire head than at the flanks, where the fire did not produce particularly strong cross-fire flow and did not significantly change the lateral fire progression. However, at the head of the fire the fire-induced winds blowing across the front were the strongest and significantly accelerated fire progression. The two-way coupled simulation including the fire-induced winds produced 36.2% faster fire propagation than the one-way coupled run, and more realistically represented the fire progression.

Benik, Jeremy T.↗

Measurement and simulation of small cryogenic neon pellet Ne-I 640 nm photon efficiency during ablation in DIII-D plasma

Small (~1 mm) neon pellet fragments are fired into DIII-D H-mode plasmas, and resulting trajectory-averaged photon efficiencies (neutral neon ionization events for every photon emitted) of S/XB ≈ 85 are estimated for Ne-I 640 nm by dividing the estimated initial pellet fragment mass by the measured number of emitted Ne-I photons. The experiments are modeled by running the Lagrangian particle (LP) fluid/magneto-hydrodynamic pellet code to estimate axial ablation plume neon density profiles and temperature profiles at each pellet position. These solutions are then fed into the PrismSPECT collisional-radiative code, which calculates resulting neon charge states and photon emission rates, giving a profile-average of S/XB ≈ 109. The burnthrough plasma minor radius predicted by LP (ρ ≈ 0.63) is reasonably close to the experimental observation ρ ≈ 0.6. Furthermore, the modeling indicates that local S/XB is not constant along the pellet trajectory but tends to increase with increasing ablation rate. Non-equilibrium kinetics are predicted to be very important, while line trapping is predicted to be relatively unimportant (for Ne-I 640 nm S/XB).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Increasing large wildfires over the western United States linked to diminishing sea ice in the Arctic

Abstract The compound nature of large wildfires in combination with complex physical and biophysical processes affecting variations in hydroclimate and fuel conditions makes it difficult to directly connect wildfire changes over fire-prone regions like the western United States (U.S.) with anthropogenic climate change. Here we show that increasing large wildfires during autumn over the western U.S. are fueled by more fire-favorable weather associated with declines in Arctic sea ice during preceding months on both interannual and interdecadal time scales. Our analysis (based on observations, climate model sensitivity experiments, and a multi-model ensemble of climate simulations) demonstrates and explains the Arctic-driven teleconnection through regional circulation changes with the poleward-shifted polar jet stream and enhanced fire-favorable surface weather conditions. The fire weather changes driven by declining Arctic sea ice during the past four decades are of similar magnitude to other leading modes of climate variability such as the El Niño-Southern Oscillation that also influence fire weather in the western U.S.

54 ENVIRONMENTAL SCIENCES↗

Design and experimental testing of a 150 kWh thermal battery using thermosiphons embedded in a concrete matrix for power plant flexible operation

One of the options for achieving the global temperature limitation of 1.5 °C target, for the mitigation of global warming, is based on the better penetration of renewables into the electrical grid. This has imposed a burden to fossil fuel fired power plants since they are required to operate away from their baseload mode to compensate for the inherent intermittence of the renewable power. Integrating energy storage with fossil plants is an option to achieve their needed flexibility. A cost competitive energy storage option for the solution is based on storing sensible heat in concrete. Here, this paper reports research results and development of a thermal battery cell (TBC) capable of operating at temperatures up to 425 °C. A novel concept consisting of a concrete matrix for sensible heat storage, engineered to provide enhanced thermal and mechanical properties, and twenty-two thermosiphon elements, engineered for dual action were designed and fabricated into a single thermal energy storage (TES) module. Research for the development of the components for the TBC was performed in the laboratory. Efficient heat transfer, to/from the storage media, was demonstrated under several charging and discharging conditions with a thermal storage capacity of 150 kWh th and a rapid discharge, making the TBC suitable for fast ramping when integrated with a fossil fuel fired power plant. Efficient radial heat transfer to the concrete was observed due to the well designed spacing and location of thermosiphons in the radial direction. A minimal temperature difference of 2 °C, between the thermosiphons bottom and top was obtained, demonstrating the isothermicity of those elements. An overall end-to-end TBC energy-to-energy round trip efficiency of 70% was achieved.

25 ENERGY STORAGE↗

Improving Unit Flexibility Utilizing Plasma Ignitors

Coal fired steam generation operators face increasing market challenges, including competition from low cost generation, renewables, and regulatory pressure. These market conditions are forcing utilities to operate their coal assets in a more flexible mode, including more frequent starts and stops, faster ramp rates, frequent cycling, and extended operation at the lowest possible loads. Without upgrades to firing and control systems, pressure parts, and auxiliary systems, CAPEX and OPEX costs will increase significantly. Typically, expensive support fuels (Oil or Gas) are required to maintain safe, stable coal ignition when operating below 25% to 35% MCR (Maximum Continuous Rating). The exact minimum load without support fuel differs depending upon unit design specifications and fuel being burned. Frequent starts also increase the use of support fuels. The firing and burner control systems must be designed to allow for proper operation over the unit’s load range, ensuring that all mechanical components operate properly, and proper control of air and fuel streams can be maintained. To address the need for frequent starts and the need for stable low load operation on coal fired steam generators, this paper discusses options available, including, Firing Systems upgrades, Digital solutions, and pressure part upgrades. Several case studies are included that highlight options available allowing units to stay in operation and reduce CAPEX and OPEX costs.

01 COAL, LIGNITE, AND PEAT↗

Radionuclide surrogate aerosolization, resuspension and suppression in hazardous situations

Radioactive fire following nuclear accidents causes resuspension of radioactive contamination that can spread over large areas. Although many papers focus on particle deposition and resuspension, a limited number of studies model its suppression. Even less data is available for the comparison of emissions across particle size, surface, and mode of resuspension. In this study, cerium dioxide surrogate for internal hazards such as radionuclide particle matter was aerosolized into a large chamber and subsequently resuspended after sedimentation. Resuspension was induced by common modes of human movement including walking, wind, and driving on common surfaces including polyvinyl chloride (PVC), artificial grass (turf), and concrete in a 5.8 m long, 3.7 m wide and 3 m high tent. The resuspension was experimentally measured for two particle sizes (1 and 10 μm) at three different heights (0.3 m, 1.2 m, and 2.4 m) and compared across size, surface, and mode of resuspension. Particle size distribution was measured using an aerodynamic particle sizer and the resuspended particles were collected with the wetted wall cyclone aerosol collector and quantitated using inductively coupled plasma mass spectrometry. The testing was repeated with the F-500 fire retardant application to study its effect on resuspension. In this study, artificial grass flooring was found to generate the most resuspension, with walking on turf for the 1 μm particle testing yielding the highest factor overall. Concrete had the lowest resuspension, showing variations in the size distribution of aerosol as a function of height from the source resuspension factors. The application of fire retardant was found to significantly reduce surrogate resuspension, regardless of resuspension method or testing surface. Here, the results provide impactful information regarding the different modes of resuspension including human transport (walking and driving) and wind for the resuspension of radionuclide surrogate particles deposited onto common surfaces and the effect of fire retardant application on their resuspension, leading to higher levels of safety for nuclear energy plants and facilities.

42 ENGINEERING↗

Dynamic infrared gas analysis from longleaf pine fuel beds burned in a wind tunnel: observation of phenol in pyrolysis and combustion phases

Pyrolysis is the first step in a series of chemical and physical processes that produce flammable organic gases from wildland fuels that can result in a wildland fire. We report results using a new time-resolved Fourier transform infrared (FTIR) method that correlates the measured FTIR spectrum with an infrared thermal image sequence, enabling the identification and quantification of gases within different phases of the fire process. The flame from burning fuel beds composed of pine needles (Pinus palustris) and mixtures of sparkleberry, fetterbush, and inkberry plants was the natural heat source for pyrolysis. Extractive gas samples were analyzed and identified in both static and dynamic modes synchronized to thermal infrared imaging: a total of 29 gases were identified including small alkanes, alkenes, aldehydes, nitrogen compounds, and aromatics, most previously measured by FTIR in wildland fires. This study presents one of the first identifications of phenol associated with both pre-combustion and combustion phases using ca. 1 Hz temporal resolution. Preliminary results indicate ~2.5× greater phenol emissions from sparkleberry and inkberry compared to fetterbush, with differing temporal profiles.

09 BIOMASS FUELS↗

High power edge-cum-surface emitting terahertz laser arrays phased locked by vacuum guided plasmon waves

Terahertz semiconductor quantum-cascade lasers (QCLs) are widely implemented with metallic cavities that support low-loss plasmonic optical modes at long wavelengths. However, resonant optical modes in such cavities suffer from poor radiative characteristics due to their subwavelength transverse dimensions. Consequently, single-mode terahertz QCLs with metallic cavities and large (>100 mW) output power have only been realized in the surface-emitting configuration that affords a large radiating surface. Here, we demonstrate a method to enhance radiative outcoupling from such plasmonic lasers for high-power emission in the edge-emitting (end-fire or longitudinal) direction. Single-sided plasmon waves propagating in vacuum are resonantly excited in surrounding medium of metallic cavities with the QCL semiconductor medium. The vacuum guided plasmon waves with a large wavefront phase-lock multiple metallic cavities longitudinally, which leads to intense radiation in multiple directions, including that in the longitudinal direction in a narrow single-lobed beam. The multicavity array radiates predominantly in a single spectral mode. A peak-power output of 260 mW and a slope efficiency of 303 mW/A are measured for the end-fire beam from a 3.3 THz QCL operating at 54 K in a Stirling cooler. Finally, single-mode operation and lithographic tuning across a bandwidth of ~150 GHz are demonstrated.

42 ENGINEERING↗

HEAF Cable Fragility Testing at the Solar Furnace at the NSTTF

In order to establish a zone of influence (ZOI) due to a high energy arcing fault (HEAF) environment, the fragility of the targets must be determined. The high heat flux/short duration exposure of a HEAF is considerably different than that of a traditional hydrocarbon fire, which previous research has addressed. The previous failure metrics (e.g., internal jacket temperature of a cable exposed to a fire) were based on low heat flux/long duration exposures. Because of this, evaluation of different physics and failure modes was considered to evaluate the fragility of cables exposed to a HEAF. Tests on cable targets were performed at high heat flux/short duration exposures to gain insight on the relevant physics and failure modes. These tests yielded data on several relevant failure modes, including electrical failure and sustained ignition. Additionally, the results indicated a relationship between the total energy of exposure and the damage state of the cable target. This data can be used to inform the fragility of the targets.

42 ENGINEERING↗

Rapid evolution of aerosol particles and their optical properties downwind of wildfires in the western US

Abstract. During the first phase of the Biomass Burn Operational Project (BBOP) field campaign, conducted in the Pacific Northwest, the DOE G-1 aircraft was used to follow the time evolution of wildfire smoke from near the point of emission to locations 2–3.5 h downwind. In nine flights we made repeated transects of wildfire plumes at varying downwind distances and could thereby follow the plume's time evolution. On average there was little change in dilution-normalized aerosol mass concentration as a function of downwind distance. This consistency hides a dynamic system in which primary aerosol particles are evaporating and secondary ones condensing. Organic aerosol is oxidized as a result. On all transects more than 90 % of aerosol is organic. In freshly emitted smoke aerosol, NH4+ is approximately equivalent to NO3. After 2 h of daytime aging, NH4+ increased and is approximately equivalent to the sum of Cl, SO42, and NO3. Particle size increased with downwind distance, causing particles to be more efficient scatters. Averaged over nine flights, mass scattering efficiency (MSE) increased in ∼ 2 h by 56 % and doubled in one flight. Mechanisms for redistributing mass from small to large particles are discussed. Coagulation is effective at moving aerosol from the Aitken to accumulation modes but yields only a minor increase in MSE. As absorption remained nearly constant with age, the time evolution of single scatter albedo was controlled by age-dependent scattering. Near-fire aerosol had a single scatter albedo (SSA) of 0.8–0.9. After 1 to 2 h of aging SSAs were typically 0.9 and greater. Assuming global-average surface and atmospheric conditions, the observed age dependence in SSA would change the direct radiative effect of a wildfire plume from near zero near the fire to a cooling effect downwind.

54 ENVIRONMENTAL SCIENCES↗

Glovebox Fires Phase 1: Simulations of Open Burner Experiments

Understanding the duration of a fire required to breach a glovebox via glove ports and/or windows within a facility is important in developing mitigation strategies for safety. To facilitate this understanding, both simulation and experiments are utilized. The approach is to first validate the Computation Fluid Dynamics (CFD) code, Fire Dynamics Simulator (FDS), with experimental data collected by New Mexico Tech (NMT) and then perform simulations of full-scale rooms containing gloveboxes to assess numerous scenarios which would otherwise be cost-prohibitive experimentally. This report provides comparison to first-phase experiments involving a fire without a glovebox. A subsequent report will provide comparison to experiments involving a glovebox. The results indicate good agreement with FDS tending to over predict the pre-mixed and diffusion-mode tests by 6% and 10%, respectively.

42 ENGINEERING↗