Method to calibrate fission chambers in Campbelling mode

Fission chambers are neutron detectors which are widely used to instrument experimental reactors such as material testing reactors or zero power reactors. In the presence of a high level mixed gamma and neutron flux, fission chambers can be operated in Campbelling mode (also known as 'fluctuation mode' or 'mean square voltage mode') to provide reliable and precise neutron related measurements. Fission chamber calibration in Campbelling mode (in terms of neutron flux) is usually done empirically using a calibrated reference detector. A major drawback of this method is that calibration measurements have to be performed in a neutron environment very similar to the one in which the calibrated detector will be used afterwards. What is proposed here is a different approach based on characterizing the fission chamber response in terms of fission rate. This way, the detector calibration coefficient is independent from the neutron spectrum and can be determined prior to the experiment. The fissile deposit response to the neutron spectrum can then be assessed independently by other means (experimental or numerical). In this paper, the response of CEA-made miniature fission chambers in Campbelling mode is studied. A theoretical model of the signal is used to calculate the calibration coefficient. The model's input parameters come from statistical distribution of individual pulses. Supporting measurements were made in the CEA Cadarache zero power reactor MINERVE and results are compared to an empirical Campbelling mode calibration. The tested fission chamber calibration coefficient is roughly 2*10{sup -26} A{sup 2}/Hz/(c/s). Both numerical and empirical methods give consistent results, however a deviation of about 15% was observed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Method to calibrate fission chambers in Campbelling mode

Fission chambers are neutron detectors which are widely used to instrument experimental reactors such as material testing reactors or zero power reactors. In the presence of a high level mixed gamma and neutron flux, fission chambers can be operated in Campbelling mode (also known as 'fluctuation mode' or 'mean square voltage mode') to provide reliable and precise neutron related measurements. Fission chamber calibration in Campbelling mode (in terms of neutron flux) is usually done empirically using a calibrated reference detector. A major drawback of this method is that calibration measurements have to be performed in a neutron environment very similar to the one in which the calibrated detector will be used afterwards. What we propose here is a different approach based on characterizing the fission chamber response in terms of fission rate. This way, the detector calibration coefficient is independent from the neutron spectrum and can be determined prior to the experiment. The fissile deposit response to the neutron spectrum can then be assessed independently by other means (experimental or numerical). In this paper, the response of CEA made miniature fission chambers in Campbelling mode is studied. We use a theoretical model of the signal to calculate the calibration coefficient. Input parameters of the model come from statistical distribution of individual pulses. Supporting measurements have been made in the CEA Cadarache zero power reactor MINERVE and results are compared to an empirical Campbelling mode calibration. The tested fission chamber calibration coefficient is about 2 10{sup -26} A{sup 2}/Hz/(c/s). Both numerical and empirical methods give consistent results, however a deviation of about 15 % was observed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Method to calibrate fission chambers in Campbelling mode

Fission chambers are neutron detectors which are widely used to instrument experimental reactors such as material testing reactors or zero power reactors. In the presence of a high level mixed gamma and neutron flux, fission chambers can be operated in Campbelling mode (also known as 'fluctuation mode' or 'mean square voltage mode') to provide reliable and precise neutron related measurements. Fission chamber calibration in Campbelling mode (in terms of neutron flux) is usually done empirically using a calibrated reference detector. A major drawback of this method is that calibration measurements have to be performed in a neutron environment very similar to the one in which the calibrated detector will be used afterwards. What we propose here is a different approach based on characterizing the fission chamber response in terms of fission rate. This way, the detector calibration coefficient is independent from the neutron spectrum and can be determined prior to the experiment. The fissile deposit response to the neutron spectrum can then be assessed independently by other means (experimental or numerical). In this paper, the response of CEA made miniature fission chambers in Campbelling mode is studied. We use a theoretical model of the signal to calculate the calibration coefficient. Input parameters of the model come from statistical distribution of individual pulses. Supporting measurements have been made in the CEA Cadarache zero power reactor MINERVE. Results are compared to an empirical Campbelling mode calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wide-range fission chambers signal simulator - 373

Fission chambers (FC) signal simulators are a useful means to test neutron flux instrumentation channels of the reactors control and protection systems (CPS). Well-known signal simulators do not provide a secondary equipment testing in all modes of measurement. A wide range simulator that simulates a full range of FC signal changes (pulse, fluctuation, current) was designed. The simulator takes into account the statistical nature of neutrons detection in the FC, including the shape of the pulse and the spectrum of the pulse amplitude distribution. The simulator uses the principle of mathematical simulation of the fission chambers signal with realtime calculations using the FPGA. The wide-range simulator reproduces a FC signal in the range of ten orders without switching ranges or playback modes while ensuring very good linearity. It allows to generate both static and dynamic test signals such as: stair-step, linearly and exponential varying signals, exponential varying signals with a linearly changing period or a signal change simulating the response of the nuclear reactor power to a given reactivity response. Continuity of reproduced signals and the ability to playback dynamic effects makes it possible the simulator using to check the algorithms of cross-linking of measuring paths, reactivity and period measuring tools and to monitor the operation of interlocking and alarm CPS functions. This article discusses the simulator's software and hardware, its features and specifications, user interface and example of the simulator using to check the neutron flux monitoring channels. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterizing the Performance of Fission Chambers for Local Neutron Flux and Spectrum Measurement

Three fission chambers were tested at The Ohio State University Research Reactor (OSURR) to evaluate fission chambers for neutron flux and spectrum measurements. Two of the fission chambers are commercial Photonis CFUR43 fission chambers—one utilizing highly enriched uranium-235 fissile deposits for thermal neutron detection and the other with highly depleted uranium-238 for fast neutron detection. This experiment was also performed in collaboration with French Alternative Energies and Atomic Energy Commission (CEA) with CEA suppling a uranium-235 loaded fission chamber built from the Photonis CFPR CE8/9 kit. The fission chambers were irradiated in a movable 6.5 inch dry tube at reactor powers of 50 kW, 200 kW, and 450 kW at ambient temperature and at 350°C. While all sensors demonstrated good linear sensitivity to reactor power, a leakage current of 6 nA was measured for the CFUR43 detectors. Additionally, the measured signal ratios of the two CFUR43 detectors did not match the theoretical values and are subject to further investigation on individual signal contributors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance Benchmark of Commercial and Developmental Fission Chambers in Elevated Temperatures

This report documents the testing of two in-core fission chamber technologies for high-temperature irradiation environments. This work is in collaboration with the French Alternative Energies and Atomic Energy Commission (CEA). The fission chamber evaluated by Idaho National Laboratory is the micro-pocket fission detector (MPFD). The fission chamber evaluated by the CEA are the 3 mm miniaturized fission chamber and the 7 mm high-temperature fission chamber. Demonstrations of the MPFD were performed at the Neutron Radiography Facility and the Massachusetts Institute of Technology Reactor. Demonstrations of the CEA fission chambers were performed at the Ohio State University Research Reactor. All demonstrations were conducted with a heated experiment rig up to 850°C.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial Back-to-Back Fission Chamber Testing in ATRC

Development and testing of in-pile, real-time neutron sensors for use in Materials Test Reactor experiments is an ongoing project at Idaho National Laboratory. The Advanced Test Reactor National Scientific User Facility has sponsored a series of projects to evaluate neutron detector options in the Advanced Test Reactor Critical Facility (ATRC). Special hardware was designed and fabricated to enable testing of the detectors in the ATRC. Initial testing of Self-Powered Neutron Detectors and miniature fission chambers produced promising results. Follow-on testing required more experiment hardware to be developed. The follow-on testing used a Back-to-Back fission chamber with the intent to provide calibration data, and a means of measuring spectral indices. As indicated within this document, this is the first time in decades that BTB fission chambers have been used in INL facilities. Results from these fission chamber measurements provide a baseline reference for future measurements with Back-to-Back fission chambers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commercial Design of Custom Front-end Electronics for a High Temperature Fission Chamber

The next generation of advanced nuclear reactor will require instrumentation designed to withstand higher temperatures and harsher environments. One of the most important instruments required to monitor power and in-core fuel management is a fission chamber. A fission chamber consists of a gas-filled chamber with a fissile coating on the inside of the chamber.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FY2018 Report on Fission Chamber Development at LANL

This report provides a description of a subset of FY18 activities conducted by Los Alamos National Laboratory (LANL) as part of the Nuclear Physics: Cumulative Fission Product Yields (Fission R-values) task of the NA-22 sponsored F2016 Venture Project. Specifically, this report describes the design, fabrication and testing of the Mark II fission chamber that was fielded as part of fission R-value measurements on the Flattop critical assembly located at the National Criticality Experiments Research Center (NCERC). Historically, fission product R-value measurements were performed by chemical separation and beta counting of samples from carefully controlled fission chamber experiments. These measurements form the basis for reporting data used in debris diagnostics and subsequent modeling. It was also the means to extract absolute cumulative fission product yields (yield per fission or $Y_i/f$ for the $i_{th}$ fission product) that are included in the international nuclear data libraries, and ultimately used in diagnostic evaluations and device modeling. The challenge for this effort was to design a functional fission chamber given the harsh neutron and gamma fields and severe space limitations of the Flattop critical assembly.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Does LSDS Analysis Require More Than One Isotopic Fission Chamber?

One of the methods of analysis of spectra measured in a Lead Slowing Down Spectrometer (LSDS) requires the measurement of time spectra in isotopic fission chambers (e.g., chambers lined with 235 U and 239 Pu), in addition to the measurement in threshold fission chambers. Since there is a correspondence between time after the initiating neutron pulse, and the neutron energy, it would seem possible that the response in one isotopic chamber can be converted to the response of any other isotopic fission chamber using the cross-section ratio of the fissile materials.

Nuclear Fuel Cycle & Fuel Materials(11)↗

Irradiation tests in BR2 of miniature fission chambers in pulse, Campbelling and current mode

The FNDS system ('Fast Neutron Detection System') for the on-line in-pile detection of the fast neutron flux in the presence of a significant thermal neutron flux and a high gamma dose rate is being developed in the framework of the SCK.CEN-CEA Laboratoire Commun. The system has been patented in 2008. The system consists of a miniature Pu-242 fission chamber as main detector, complemented by a U-235 fission chamber or a rhodium Self-Powered Neutron Detector (SPND) for thermal neutron flux monitoring and a dedicated acquisition system that also takes care of the processing of the signals from both detectors to extract fast neutron flux data. This paper describes a FNDS qualification experiment in the SCK.CEN BR2 reactor, with experimental results on a large set of fission chambers in current and Campbelling mode. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Test facility for fission chamber assemblies - 239

The Institution -Project Center ITER- with participation of the National Research Nuclear University MEPhI are developing the neutron diagnostics -Divertor Neutron Flux Monitor- (DNFM) for the International Thermonuclear Experimental Reactor (ITER). This diagnostics shall ensure measurement of the total neutron yield and ITER fusion power. Assemblies of fission chambers (FC) with different fissile materials and sensitivities are planned to be used for the neutron flux measurement. Study of fission chambers characteristics and acceptance testing of the diagnostic system will be carried out at the testing facility of the neutronic laboratory of the 'TRINITI' Institute. The facility includes: compact powerful neutron generator with the power, control and monitoring system; remote handling system for FCs positioning and movement; novel three channels data acquisition and processing system. Each acquisition channel contains some measuring circuits with signal processing. This set of circuits provides neutron flux measurement in the range of at least 10 decades for each single FC. Data acquisition and processing system features are: signal digitizing with sample rate up to 125 MHz; real time data processing with computation and data update cycle from 0.1 ms. This paper examines the structure, composition and specification of the test facility. Application software, hardware solutions and the results of fission chambers prototypes tests are discussed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Temperature Fission Chamber for He- and FLiBe-cooled Reactors

We have evaluated candidate technologies for in-core fission chambers for high-temperature reactors to monitor power level via measurements of neutron flux from start-up through full power at up to 800°C. This research is important because there are no commercially available instruments capable of operating above 550 °C. Component materials and processes were investigated for fission chambers suitable for operation at 800 °C in reactors cooled by molten fluoride salt (FLiBe) or flowing He, with an emphasis placed on sensitivity (≥ 1 cps/nv), service lifetime (2 years at full power), and resistance to direct immersion in FLiBe. The latter gives the instrument the ability to survive accidents involving breach of a thimble. The device is envisioned to be a two-gap, three-electrode instrument constructed from concentric nickel-plated alumina cylinders and using a noble gas–nitrogen fill-gas. We report the results of measurements and calculations of the response of fill gasses, impurity migration in nickel alloy, brazing of the alumina insulator, and thermodynamic calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral indices measurements using miniature fission chambers at the MINERVE zero-power reactor at CEA using calibration data obtained at the BR1 reactor at SCK.CEN

Spectral indices are parameters of major importance to characterize a multiplying medium and to evaluate performances of neutronics calculation tools as well as quality of associated nuclear data. Experiments performed in 2004 at the CEA MINERVE facility loaded with the R1-UO{sub 2} lattice [1], using homemade miniature fission chambers and calibration data acquired at the SCK.CEN BR1 facility in 2001 [2], resulted in ambivalent conclusions. On one hand, spectral indices involving only fissile isotopes gave relevant results and consistent discrepancies between calculation and experiment. On the other hand, spectral indices involving both fissile and fertile isotopes showed inconsistent results depending on the type of calibration data used. In particular, the {sup 238}U(n,f)/{sup 235}U(n,f) spectral indices resulted in values far from the calculations in all cases. In 2004, those differences between measurement and calculation were mainly attributed to an imprecise knowledge of the isotopic composition of the deposits loaded in the {sup 238}U chambers. At that time, priorities in the development of programs in MINERVE and other considerations about the manufacturing and calibration of new fission chambers did not allow to further investigate these discrepancies. In 2009, the preparation of a new program at the EOLE facility [1] and changes in the regulatory framework for management of fission chambers motivated the manufacturing of new detectors. At the same time, the re-installation of the R1-UO{sub 2} lattice in MINERVE gave the opportunity to carry out a new spectral indices measurement campaign. Nevertheless, although the isotopic composition of active deposits was better known than previously, the comparison between experimental results and calculations still resulted in inconsistent discrepancies. A sensitivity study indicated afterwards that, among all parameters to be considered for the analysis and the assessment of final uncertainty, calibration data have the greatest impact. In April 2010, a new calibration campaign conducted again at the BR1 facility allowed the CEA to reanalyze the spectral indices measurements performed in 2009. With this new set of calibration data, the experimental values of spectral indices finally matched the calculation results within the uncertainty margins. In addition, the confrontation of data from 2001 and 2010 calibration campaigns, both performed with the same experimental conditions, allowed to shed on the light dead time correction issues in the monitoring of calibration measurements. At the end, this also explained the inconsistencies observed during the 2004 campaign. This paper first, presents the two different analysis methods for getting the experimental value of a spectral index and, lists main parameters that influence the determination of the experimental value. It then details the calibration processes that are set-up at the MINERVE and BR1 facilities, describes the various experiments carried out and finally comments the results obtained. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Determining fissile content in PWR spent fuel assemblies using a passive neutron Albedo reactivity with fission chambers technique

State regulatory bodies and organizations such as the IAEA that are concerned with preventing the proliferation of nuclear weapons are interested in a means of quantifying the amount of plutonium in a given spent fuel assembly. The complexity of spent nuclear fuel makes the measurement of plutonium content challenging. There are a variety of techniques that can measure various properties of spent nuclear fuel including burnup, and mass of fissile content. No single technique can provide all desired information, necessitating an approach using multiple detector systems and types. This paper presents our analysis of the Passive Neutron Albedo Reactivity Fission Chamber (PNAR-FC) detector system. PNAR-FC is a simplified version of the PNAR technique originally developed in 1997. This earlier research was performed with a high efficiency, {sup 3}He-based system (PNAR-3He) with which multiplicty analysis was performed. With the PNAR technique a portion of the spent fuel assembly is wrapped in a 1 mm thick cadmium liner. Neutron count rates are measured both with and without the cadmium liner present. The ratio of the count rate with the cadmium liner to the count rate without the cadmium liner is calculated and called the cadmium ratio. In the PNAR-3He technique, multiplicity measurements were made and the cadmium ratio was shown to scale with the fissile content of the material being measured. PNAR-FC simplifies the PNAR technique by using only a few fission chambers instead of many {sup 3}He tubes. Using a simplified PNAR-FC technique provides for a cheaper, lighter, and thus more portable detector system than was possible with the PNAR-3He system. The challenge with the PNAR-FC system are two-fold: (1) the change in the cadmium ratio is weaker as a afunction of the changing fissile content relative to multiplicity count rates, and (2) the efficiency for the fission chamber based system are poorer than for the {sup 3}He based detectors. In this paper, we present our research on using the PNAR-FC detector system to quantify the fissile content of a spent nuclear fuel assembly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of the high temperature fission chamber technology for the French fast reactor program

High temperature fission chambers are key instruments for the control and protection of the sodium-cooled fast reactor. First, the developments of those neutron detectors, which are carried out either in France or abroad are reviewed. Second, the French realizations are assessed with the use of the technology readiness levels in order to identify tracks of improvement. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A new measurement of the 6 Li(n,α)t cross section at MeV energies using a 252 Cf fission chamber and 6 Li scintillators

We present a new measurement of the 6 Li(n,α)t cross section from 245 keV to 10 MeV using a 252 Cf fission chamber with 6 LiI(Eu) and Cs 2 LiYCl 6 :Ce (CLYC) scintillators which act as both target and detector. Neutron energies are determined from the time of flight (TOF) method using the signals from spontaneous fission and reaction product recoil. Simulations of neutron downscatter in the crystals and fission chamber bring 6 Li(n,α)t cross section values measured with the 6 LiI(Eu) into agreement with previous experiments and evaluations, except for two resonances at 4.2 and 6.5 MeV introduced by ENDF/B-VII.1. Suspected neutron transport modeling issues cause the cross section values obtained with CLYC to be discrepant above 2 MeV.

252Cf fission chamber↗

Evaluation of Testing Facilities for a High Temperature Fission Chamber Design

Oak Ridge National Laboratory (ORNL) developed a first-of-its-kind high-temperature fission chamber (HTFC) prototype that could survive in the harsher environments of advanced reactors with high flux fields up to 10 13 n/cm 2 -s and temperatures upwards of 700°C. The first prototype of the HTFC was demonstrated at the Ohio State University Research Reactor (OSURR) in October 2017. The experiment at the OSURR was designed to demonstrate four regions of operation: low flux and low temperatures, low flux and high temperatures, high flux and low temperatures, and high flux and high temperatures. Although some problems developed during the experiment at the OSURR, data was obtained and the fission chamber was shipped back to ORNL. The problems were diagnosed and documented at ORNL, and the HTFC was reassembled. Testing will proceed at ORNL at temperatures up to 700°C. This report discusses other possible test facilities to demonstrate the HTFC instrument prototype after reassembly.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗