Swelling of FK800

The report summarizes an assessment of the strain experienced by FK800 upon change in humidity and temperature of its surroundings. The FK800 samples were obtained from Laural Hargrove in the form of a disk that was 12 mm in diameter and 0.5 – 1 mm in thickness. The sample had a Lot # 05172301. For TMA testing, the sample was cut into a small film of dimensions 0.5 mm x 3.38 mm x 6.57 mm and tested under the tensile mode. A single set of swelling experiments were performed on the sample between November and December 2024.

36 MATERIALS SCIENCE↗

Characterization of Various Materials Using Refractometry

Refractive index (RI) is a fundamental physical property of a material. However, the RI values of several binders, including nitroplasticizer (NP), Estanes, and KelF/FK 800, are not available in literature. Further, their temperature dependencies are undocumented either. In this study, we have developed a set of methodologies to accurately and effectively determine the RIs of these binder materials between 20 and 70°C. The RIs of these binders without aging show linear correlations with temperature, as shown in the figure below. Among these materials, Estane 5714 has the highest RI whereas FK800 has the lowest RI. As materials age, the changes in their RIs are different, suggesting different aging behavior of these binders upon heating. Typically, NP and Estane degraded through hydrolysis give lower RIs than the baseline materials. However, when KelF/FK800 materials thermally age, their RIs increase. Overall, this study demonstrates refractometry is a sensitive technique to detect aging signs in various materials of interest.

36 MATERIALS SCIENCE↗

Phase changes in fluoropolymer binders

Motivation: Understanding fluoropolymer binder structure and aging response continues to be an important goal for the prediction and assessment of polymer bonded explosive compositions within the stockpile. As part of ongoing efforts within NNM, we are developing new methods to quantify crystallization and chemical degradation within aged Fluoropolymer materials. Significance: Time, temperature and radiation are known to alter the mechanical properties of fluoropolymers as crystalline domains nucleate and grow within the material. However, current methods do not accurately quantify and assess the degree or rapidity of these physical aging processes. For this reason, we are developing methods that directly measure crystalline domain, composition, size and shape and cross-correlating them with traditional techniques. Progress: Most recently, we thermally aged fluoropolymer binder, FK800, for various durations up to 23 days at several temperatures including: 25C (red), 35C (green), and 60C (blue). We used wide angle X-ray scattering (WAXS) to observe when crystalline peaks emerged, signaling a phase transition from amorphous to partially crystalline. Some of these data are summarized in Figure 1. As expected, samples held at 25C (red), which is below the glass transition temperature at 28C, remain amorphous – the WAXS data (Figure 1b) lacks sharp peaks indicative of crystallinity and the ultra-small angle X-ray scattering (USAXS) also has a smooth background without peaks indicative of structure (Figure 1a). By contrast, samples held at 35C and 60C have new peaks in both the USAXS and WAXS data. The structure is clearer after subtracting off the amorphous background from the WAXS data (Figure 1c). These data show that samples aged at 60C are more crystalline as determined by the more defined peaks and also have a larger lattice constant as seen by the shift in peak position as compared to the 35C samples. The corresponding USAXS data (Figure 1a) indicate that the size of the crystals was larger at 60C than at 35C as seen by the shift in the knee position to lower q-values. Interestingly, the shape of the scatter curve also changed, which indicates a change in morphology. Atomic force microscopy (AFM) was used to image the fluoropolymer (Figure 1c-e). At 35C, ~50nm long stacked crystal plates are observed. High resolution imaging shows that the stacks consist of 2-6 lamellae that are spaced approximately 3nm apart. At 60C, the individual lamella appear both thicker and longer and are intertwined to fill the surface. Morphological data such as these images help to interpret & model volume averaging techniques like X-ray scattering and NMR. We also expect the shift from isolated islands to intertwined clusters to impact mechanical properties.