Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLASH FORWARD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

From Project Mercury to the Breadboard Project

NASA's Project Mercury began as a response to the cold war with the Soviet Union and had a number of goals: to place a manned spacecraft in orbital flight around the earth; to investigate man's performance capabilities and his ability to function in the environment of space and to recover the man and the spacecraft safely. One aspect of preflight testing included the use of an altitude chamber to test each capsule and allow the astronauts to engage in simulated missions within a vacuum environment. Flash forward to 1985. The Biomedical Operations and Research Office at Kennedy Space Center proposed to use the chamber for an unusual mission under what was known as the Controlled Ecological Life Support Systems (CELSS)Breadboard Project. During 1985 into 1987, the chamber was converted to an environmentally-controlled, hydroponic plant growth chamber termed the "Biomass Production Chamber" and operated through late 2001.

Dreschel, Thomas W.↗

The Real Science Behind FlashForward

Berkeley Lab nuclear physicist Peter Jacobs discusses the ALICE experiment, setting of the science fiction novel FlashForward.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Composite Bond Line Measurements Based on a Bayesian Analysis of Flash Thermography Data

For bonded composite materials, an accurate characterization of the adhesive bond line is needed to predict failure modes and fracture toughness. In this paper, bond line thickness was estimated from data obtained using through transmission flash thermography. The forward model that predicts back surface temperature is based on a three layer heat diffusion equation with varying diffusivity and flux boundary conditions. The corresponding inverse problem of estimating bond line thickness from measurement data was solved using a Bayesian approach that assumed Gaussian priors for the bond line thickness and thermal diffusivity of the adherends. Finally, the outputs of the thermography based method were compared to measurements that were collected using a micrometer and ultrasound testing.

Flash thermography↗

Composite Bond Line Measurements Based on A Bayesian Analysis of Flash Thermography Data

For bonded composite materials, an accurate characterization of the adhesive bond line is needed to predict failure modes and fracture toughness. In this paper, bond line thickness was estimated from data obtained using through transmission flash thermography. The forward model that predicts back surface temperature is based on a three layer heat diffusion equation with varying diffusivity and flux boundary conditions. The corresponding inverse problem of estimating bond line thickness from measurement data was solved using a Bayesian approach that assumed Gaussian priors for the bond line thickness and thermal diffusivity of the adherends. Finally, the outputs of the thermography based method were compared to measurements that were collected using a micrometer and ultrasound testing.

Flash thermography↗

Thermal Inspection of a Composite Fuselage Section Using theMethod of Proper Generalized Decomposition

Proper Generalized Decomposition (PGD) is a reduced order modeling technique for the simulation of physical systems whose governing equations depend on boundary conditions, initial conditions, material properties, and geometric parameters. It uses separated representations of system covariates combined with an iterative approximation method known as successive enrichment in order to compute an accurate parameter-dependent approximation to the full governing equations. PGD can also be used as an alternative to the Singular Value Decomposition (SVD) of a matrix and therefore as an alternative to PCA thermography. In this paper PGD was used to analyze data derived from the inspection of a composite fuselage forward section using flash thermography, and the results were compared against the standard PCA approach.

Nondestructive Evaluation↗

PAIR-DOMINATED GeV-OPTICAL FLASH IN GRB 130427A

We show that the light curve of the double GeV+optical flash in GRB 130427A is consistent with radiation from the blast wave in a wind-type medium with density parameter A = ρr {sup 2} ∼ 5 × 10{sup 10} g cm{sup –1}. The peak of the flash is emitted by copious e {sup ±} pairs created and heated in the blast wave; our first-principle calculation determines the pair-loading factor and temperature of the shocked plasma. Using detailed radiative transfer simulations, we reconstruct the observed double flash. The optical flash is dominated by synchrotron emission from the thermal plasma behind the forward shock, and the GeV flash is produced via inverse Compton (IC) scattering by the same plasma. The seed photons for IC scattering are dominated by the prompt MeV radiation during the first tens of seconds, and by the optical to X-ray afterglow thereafter. IC cooling of the thermal plasma behind the forward shock reproduces all GeV data from a few seconds to ∼1 day. We find that the blast wave Lorentz factor at the peak of the flash is Γ ≈ 200, and the forward shock magnetization is ε{sub B} ∼ 2 × 10{sup –4}. An additional source is required by the data in the optical and X-ray bands at times >10{sup 2} s; we speculate that this additional source may be a long-lived reverse shock in the explosion ejecta.

79 ASTRONOMY AND ASTROPHYSICS↗

NAND Flash Qualification Guideline

Better performing Forward Error Correction on the forward link along with adequate power in the data open an uplink operations trade space that enable missions to: Command to greater distances in deep space (increased uplink margin). Increase the size of the payload data (latency may be a factor). Provides space for the security header/trailer of the CCSDS Space Data Link Security Protocol. Note: These higher rates could be used for relief of emergency communication margins/rates and not limited to improving top-end rate performance. A higher performance uplink could also reduce the requirements on flight emergency antenna size and/or the performance required from ground stations. Use of a selective repeat ARQ protocol may increase the uplink design requirements but the resultant development is deemed acceptable, due the factor of 4 to 8 potential increase in uplink data rate.

Floating Gate Memory↗

SU-G-IeP2-15: Virtual Insertion of Digital Kidney Stones Into Dual-Source, Dual- Energy CT Projection Data

Purpose: In order to investigate novel methods to more accurately estimate the mineral composition of kidney stones using dual energy CT, it is desirable to be able to combine digital stones of known composition with actual phantom and patient scan data. In this work, we developed and validated a method to insert digital kidney stones into projection data acquired on a dual-source, dual-energy CT system. Methods: Attenuation properties of stones of different mineral composition were computed using tabulated mass attenuation coefficients, the chemical formula for each stone type, and the effective beam energy at each evaluated tube potential. A previously developed method to insert lesions into x-ray CT projection data was extended to include simultaneous dual-energy CT projections acquired on a dual-source gantry (Siemens Somatom Flash). Digital stones were forward projected onto both detectors and the resulting projections added to the physically acquired sinogram data. To validate the accuracy of the technique, digital stones were inserted into different locations in the ACR CT accreditation phantom; low and high contrast resolution, CT number accuracy and noise properties were compared before and after stone insertion. The procedure was repeated for two dual-energy tube potential pairs in clinical use on the scanner, 80/Sn140 kV and 100/Sn140 kV, respectively. Results: The images reconstructed after the insertion of digital kidney stones were consistent with the images reconstructed from the scanner. The largest average CT number difference for the 4 insert in the CT number accuracy module of the phantom was 3 HU. Conclusion: A framework was developed and validated for the creation of digital kidney stones of known mineral composition, and their projection-domain insertion into commercial dual-source, dual-energy CT projection data. This will allow a systematic investigation of the impact of scan and reconstruction parameters on stone attenuation and dual-energy behavior under rigorously controlled conditions. Dr. McCollough receives research support from Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

Thermal Property Measurement of Semiconductor Melt using Modified Laser Flash Method

This study further developed standard laser flash method to measure multiple thermal properties of semiconductor melts. The modified method can determine thermal diffusivity, thermal conductivity, and specific heat capacity of the melt simultaneously. The transient heat transfer process in the melt and its quartz container was numerically studied in detail. A fitting procedure based on numerical simulation results and the least root-mean-square error fitting to the experimental data was used to extract the values of specific heat capacity, thermal conductivity and thermal diffusivity. This modified method is a step forward from the standard laser flash method, which is usually used to measure thermal diffusivity of solids. The result for tellurium (Te) at 873 K: specific heat capacity 300.2 Joules per kilogram K, thermal conductivity 3.50 Watts per meter K, thermal diffusivity 2.04 x 10(exp -6) square meters per second, are within the range reported in literature. The uncertainty analysis showed the quantitative effect of sample geometry, transient temperature measured, and the energy of the laser pulse.

Lin, Bochuan↗

On the origin of GeV emission in gamma-ray bursts

The most common progenitors of gamma-ray bursts (GRBs) are massive stars with strong stellar winds. We show that the GRB blast wave in the wind should emit a bright GeV flash. It is produced by inverse-Compton cooling of the thermal plasma behind the forward shock. The main part of the flash is shaped by scattering of the prompt MeV radiation (emitted at smaller radii) which streams through the external blast wave. The inverse-Compton flash is bright due to the huge e {sup ±} enrichment of the external medium by the prompt radiation ahead of the blast wave. At late times, the blast wave switches to normal synchrotron-self-Compton cooling. The mechanism is demonstrated by a detailed transfer simulation. The observed prompt MeV radiation is taken as an input of the simulation; we use GRB 080916C as an example. The result reproduces the GeV flash observed by the Fermi telescope. It explains the delayed onset, the steep rise, the peak flux, the time of the peak, the long smooth decline, and the spectral slope of GeV emission. The wind density required to reproduce all these features is typical of Wolf-Rayet stars. Our simulation predicts strong TeV emission 1 minute after the burst trigger; then a cutoff in the observed high-energy spectrum is expected from absorption by extragalactic background light. In addition, a bright optical counterpart of the GeV flash is predicted for plausible values of the magnetic field; such a double (optical+GeV) flash has been observed in GRB 130427A.

79 ASTRONOMY AND ASTROPHYSICS↗

Precision timing measurement of phototube pulses using a flash analog-to-digital converter

We present the timing characteristics of the flash ADC readout of the GlueX forward calorimeter, which depends on precise measurement of arrival time of pulses from FEU 84-3 photomultiplier tubes to suppress backgrounds. The tests presented were performed using two different 250 MHz prototype flash ADC devices, one with eight-bit and one with 12-bit sampling depth. All measured time resolutions were better than 1 ns, independent of signal size, which is the design goal for the GlueX forward calorimeter. For pulses with an amplitude of 100 mV the timing resolution is 0.57±0.18 ns, while for 500 mV pulses it is 0.24±0.08 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Inspection of a Composite Fuselage Section Using a Fixed Eigenvector Principal Component Analysis Method

A composite fuselage aircraft forward section was inspected with flash thermography. The fuselage section is 24 feet long and approximately 8 feet in diameter. The structure is primarily configured with a composite sandwich structure of carbon fiber face sheets with a Nomex(Trademark) honeycomb core. The outer surface area was inspected. The thermal data consisted of 477 data sets totaling in size of over 227 Gigabytes. Principal component analysis (PCA) was used to process the data sets for substructure and defect detection. A fixed eigenvector approach using a global covariance matrix was used and compared to a varying eigenvector approach. The fixed eigenvector approach was demonstrated to be a practical analysis method for the detection and interpretation of various defects such as paint thickness variation, possible water intrusion damage, and delamination damage. In addition, inspection considerations are discussed including coordinate system layout, manipulation of the fuselage section, and the manual scanning technique used for full coverage.

Zalameda, Joseph N.↗

Insights Into Lightning K‐Leader Initiation and Development From Three Dimensional Broadband Interferometric Observations

Abstract We report detailed observations of K‐leaders and the activity between them with the three‐dimensional Broadband Interferometric Mapping and Polarization system (BIMAP‐3D) at Los Alamos National Laboratory. It is found that K‐leaders have a general propagation trend of initial acceleration and then gradual deceleration, and the corresponding very high frequency (VHF) radiation power is exponentially correlated with the leader speed. Based on the 3D development and simultaneous electric field change measurement, some simple K‐leaders can be modeled with time‐evolving point charges at the propagating leader tip and at the stationary origin. We found that the charge magnitude increases during the initial acceleration stage and stays relatively constant for the rest of the development. K‐leaders are observed to interact with other branches; the branches affect the leader's propagation speed, and may affect the charge transfer. After the occurrence of a K‐leader, VHF emissions are quenched for several milliseconds. VHF sources then reappear in an impulsive and scattered manner as “twinkling,” and these sources are found not uniquely on the so‐called needles, but also on the main channel. These twinkling sources start near the apparent positive leader tip, and extend back toward the direction of the flash origin at about 10 5 m/s, while the apparent positive tip continues to extend forward at about 10 4 m/s. The twinkling extending toward the direction of flash origin appears to initiate the following K‐leader, although it may be interrupted by a K‐leader along a different branch, or simply die out without more K‐leader activity.

54 ENVIRONMENTAL SCIENCES↗

Coherent flash of light emitted by a cold atomic cloud

When a resonant laser sent on an optically thick cold atomic cloud is abruptly switched off, a coherent flash of light is emitted in the forward direction. This transient phenomenon is observed due to the highly resonant character of the atomic scatterers. We analyze quantitatively its temporal properties and show very good agreement with theoretical predictions. Based on complementary experiments, the phase of the coherent field is reconstructed without interferometric tools.

74 ATOMIC AND MOLECULAR PHYSICS↗

Management and dewatering of brines extracted from geologic carbon storage sites

Subsurface pressure management is a significant challenge in geologic CO 2 storage. Elevated pressure generated from the injection of supercritical CO 2 can be managed by the withdrawal of brine from saline formations before or during CO 2 injection; however, management of the extracted brines is non-trivial because they may have high concentrations of dissolved solids and other contaminants. Dewatering a brine can reduce the volume needing disposal; in addition, water separated from the brine can be a source of usable low salinity water. This review will summarize the composition of brines extracted from select domestic geologic CO 2 storage sites, will calculate the minimum of work of dewatering, and will provide a critical review of developed and developing desalination/dewatering technologies that could be applied to brines extracted from saline formations before or during geologic CO 2 storage operations. Herein are also highlighted, when appropriate, the similarities and the differences between dewatering brines produced from oil/gas operations and brines extracted from geologic CO 2 storage. Since a source of steam or natural gas is likely unavailable/unsuitable for dewatering brines extracted during CO 2 storage, the ideal treatment processes should have a high electrical efficiency and, if possible, should be able to take advantage of the inherent elevated temperature of these brines.

42 ENGINEERING↗

Flash Optical Energy from the Geostationary Lightning Mapper

The Geostationary Operational Environmental Satellite -16 (GOES-16) Geostationary Lightning Mapper (GLM) is evaluated for many months during the Post Launch Product Test (PLPT) phase in order to ensure that optimal products are available for both the operational forecasting and broader scientific research communities. The emphasis of the PLPT phase is to validate the GLM performance (i.e., lightning flash detection efficiency, geolocation and time-stamp accuracy) using an extensive network of independent ground-based, in-situ, and space-based reference lightning detection systems. However, another essential aspect of the PLPT phase is to obtain benchmarks of the GLM lightning optical amplitude, so that any long-term degradation in the nadir-staring GLM camera system can be realized and quantitatively assessed. This is accomplished in a straight-forward manner by collecting a very large sample of lightning flashes across many geographical regions in the GLM field-of-view so that statistically meaningful benchmarks of lightning optical amplitude (i.e., optical energy in units of femto-joules per flash) are obtained. The benchmarking is particularly important to follow-on studies that will attempt to incorporate the flash optical energy product into new derived products (e.g., energy-weighted lightning "jump" warning algorithms, and lightning nitrogen oxides production estimates).

Lightning↗

Comprehensive Review of DPF-based Flash Neutron Radiography Viability

MJOLNIR (MegaJOule Neutron Imaging Radiography) is a Dense Plasma Focus (DPF) being developed by LLNL as a prototype to assess the viability of a DPF as a flash neutron radiography source. To date, MJOLNIR has discharged up to 1.3 MJ of stored energy into a deuterium plasma load and achieved yields up to 1.2 × 10 12 neutrons per discharge. The MJOLNIR pulse length already meets the preliminary requirements for flash neutron radiography and we demonstrate in this report plausible paths forward to meet the yield requirement in a deuterium plasma. MJOLNIR’s neutron spot size has been characterized to be a factor of two greater than radiography requirements and presents the greatest challenge. A path forward to sufficiently shrinking spot size is outlined in this report, using a combination of gas dopants and a smaller anode implosion radius. A DPF is a plasma device with coaxial electrodes whose discharge ends with a stagnated hot and dense plasma column on-axis, at the tip of the central anode. Inside the MJOLNIR DPF plasma column, both thermal and beam target processes generate neutrons. To understand the underlying physics of neutron generation inside the DPF, we model the experiment using a combination of kinetic, fluid, and reduced-order models we have been developing for over ten years at LLNL. Our numerical tools are also pivotal to charting the path forward because they allow us to numerically test out which modifications would improve the DPF’s characteristic output.

42 ENGINEERING↗

Roadmap on basic research needs for laser technology

Motivated by the profound impact of laser technology on science, arising from an increase in focused light intensity by seven orders of magnitude and flashes so short electron motion is visible, this roadmap outlines the paths forward in laser technology to enable the next generation of science and applications. Despite remarkable progress, the field confronts challenges in developing compact, high-power sources, enhancing scalability and efficiency, and ensuring safety standards. Future research endeavors aim to revolutionize laser power, energy, repetition rate and precision control; to transform mid-infrared sources; to revolutionize approaches to field control and frequency conversion. These require reinvention of materials and optics to enable intense laser science and interdisciplinary collaboration. The roadmap underscores the dynamic nature of laser technology and its potential to address global challenges, propelling progress and fostering sustainable development. Ultimately, advancements in laser technology hold promise to revolutionize myriad applications, heralding a future defined by innovation, efficiency, and sustainability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗