Neutronic Simulation of Curved Fuel Plate with Flat Plate Geometry
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Not Available
Abstract not provided.
A one-dimensional nonstationary three-element distributed thermal model of a flat-plate collector with allowance for time variation of the temperatures through the “thickness” of the elements and along the length of the solar collector (SC) has been developed and software-implemented. The main data in this model consist of the thermophysical and overall parameters of the collector elements, heat carrier inlet velocity, solar radiation density, and ambient and sky temperature. To decrease the calculation variants, the variation ranges of mass flow of the heat carrier and its flow velocity were estimated for the characteristic parameters of the heat-removal channels of flat-plate SCs. It has been found that the specific mass flows of water in flat-plate SCs are 2.5–10 g/(s m{sup 2}), and the water flow velocity is 0.0005–0.002 m/s. It is shown that the instantaneous efficiency coefficient and temperature of the heat carrier can fall outside stationary values within 1–3 h. However, the daily efficiency coefficients of the SC do not fall outside the stationary values even within a day. The developed flat-plate SC model can be used to estimate the influence of the thermophysical and overall parameters of the elements, as well as the parameters of the environment, on its thermophysical characteristics when developing flat-plate SCs and methods for experimentally determining their characteristics.
Manufacturing industries require process heating for a wide variety of operations, such as drying, cooking, washing, and sterilizing. Studies of industrial energy consumption have shown that more than 50% of industrial heating demand is in the low (<60 °C), medium (60-150 °C), and medium-high (<250 °C) temperature ranges. A significant fraction of this low temperature thermal energy could be generated by commercially available solar flat-plate collector thermal energy systems, which would reduce the use of fossil fuels, energy cost volatility, and carbon emissions. However, manufacturing industries have not been able to take advantage of solar flat-plate collector systems for two main reasons: First, information is not readily available about when and what flat-plate collector system sizes can be economically applied and, second, manufacturers often do not have appropriate personnel or analysis tools to make decisions about installation of solar flat-plate collector systems. The goal of this research is to provide design decision support to small- and medium-sized manufacturers in conducting feasibility analysis for the application of solar flat-plate collector systems in their operations. The $\bar{φ}, f$-chart method and modified $\bar{φ}, f$-chart design method are used to predict the amount of energy collected by solar flat-plate collectors. A simplified model is proposed to assess the cost of solar flat-plate collector energy systems. To demonstrate the presented feasibility analysis methodology, a decision support software application is developed. What-if scenarios are presented for several geographic locations of varying climates. A sensitivity analysis of savings-to-investment ratio (SIR) was performed by changing selected input parameters by ±30% from the base case. It was found that SIR is sensitive to natural gas price, followed by collector area dependent cost, discount rate, cost of the auxiliary gas heater, and cost of the preheating system.
A one-dimensional transient numerical model for flat-plate solar thermal devices is here presented. The model permits the analysis of different configurations and components such as multiple-glazing, transparent insulation, air-gaps, surface coatings, opaque insulation and energy accumulation in water or PCM internal stores. In order to obtain information of practical interest, the solar thermal devices are modelled following virtual testing procedures in accordance to the experimental test methods described by European and International standards. This paper describes the basis of the model and shows some comparison of numerical and experimental data as an example of the validation process that has been carried out in order to assess the credibility of the numerical model. For simplicity, the explanation is restricted to standard multiple-glazed flat-plate collectors. The use of the model in other more complicated configurations as in transparently insulated covers or integrated collector storage devices with phase change materials will be presented in other separate papers. (author)
Here we provide a discussion regarding the applicability of a family of traditional heat transfer correlation based models for several (unit level) heat transfer problems associated with flight heat transfer estimates and internal flow heat transfer associated with an experimental simulation design (Dobranich 2014). Variability between semi-empirical free-flight models suggests relative differences for heat transfer coefficients on the order of 10%, while the internal annular flow behavior is larger with differences on the order of 20%. We emphasize that these expressions are strictly valid only for the geometries they have been derived for e.g. the fully developed annular flow or simple external flow problems. Though, the application of flat plate skin friction estimate to cylindrical bodies is a traditional procedure to estimate skin friction and heat transfer, an over-prediction bias is often observed using these approximations for missile type bodies. As a correction for this over-estimate trend, we discuss a simple scaling reduction factor for flat plate turbulent skin friction and heat transfer solutions (correlations) applied to blunt bodies of revolution at zero angle of attack. The method estimates the ratio between axisymmetric and 2-d stagnation point heat transfer skin friction and Stanton number solution expressions for sub-turbulent Reynolds numbers %3C1x10 4 . This factor is assumed to also directly influence the flat plate results applied to the cylindrical portion of the flow and the flat plate correlations are modified by
In order to cope up with the increase in energy demand and decline in fossil fuels, it has become imperative to use renewable resources efficiently. Among these renewable resources, solar thermal energy is abundant in nature. Solar water heating systems are one of the most important applications of solar thermal energy. Providing internal fins to absorber tube is the technique to improve heat transfer augmentation. Hence in the present study, experiments were performed on solar flat plate collector with different cross section of absorber tubes (plain tube and internally grooved tubes with different helix angles) and by varying the mass flow rates of the working fluids. This study reports the experimental results of flat plate collector, where the working fluid is water and aqueous ethylene glycol (50 : 50). Temperature profile of grooved absorber tube will be compared with plain tube. Since conversion efficiency of solar devices is low, the present study mainly focuses on improving the efficiency of solar flat plate collector.
This paper describes experimental and numerical investigations focused on the shock wave modification, induced by a dc glow discharge, of a Mach 2 flow under rarefied regime. The model under investigation is a flat plate equipped with a plasma actuator composed of two electrodes. The glow discharge is generated by applying a negative potential to the upstream electrode, enabling the creation of a weakly ionized plasma. The natural flow (i.e. without the plasma) exhibits a thick laminar boundary layer and a shock wave with a hyperbolic shape. Images of the flow obtained with an ICCD camera revealed that the plasma discharge induces an increase in the shock wave angle. Thermal effects (volumetric, and at the surface) and plasma effects (ionization, and thermal non-equilibrium) are the most relevant processes explaining the observed modifications. The effect induced by the heating of the flat plate surface is studied experimentally by replacing the upstream electrode by a heating element, and numerically by modifying the thermal boundary condition of the model surface. The results show that for a similar temperature distribution over the plate surface, modifications induced by the heating element are lower than those produced by the plasma. This difference shows that other effects than purely thermal effects are involved with the plasma actuator. Measurements of the electron density with a Langmuir probe highlight the fact that the ionization degree plays an important role into the modification of the flow. The gas properties, especially the isentropic exponent, are indeed modified by the plasma above the actuator and upstream the flat plate. This leads to a local modification of the flow conditions, inducing an increase in the shock wave angle.
New comparative tests on two different types of solar collectors are presented in this paper. A standard glazed flat plate collector and an evacuated tube collector are installed in parallel and tested at the same working conditions; the evacuated collector is a direct flow through type with external compound parabolic concentrator (CPC) reflectors. Efficiency in steady-state and quasi-dynamic conditions is measured following the standard and it is compared with the input/output curves measured for the whole day. The first purpose of the present work is the comparison of results in steady-state and quasi-dynamic test methods both for flat plate and evacuated tube collectors. Besides this, the objective is to characterize and to compare the daily energy performance of these two types of collectors. An effective mean for describing and analyzing the daily performance is the so called input/output diagram, in which the collected solar energy is plotted against the daily incident solar radiation. Test runs have been performed in several conditions to reproduce different conventional uses (hot water, space heating, solar cooling). Results are also presented in terms of daily efficiency versus daily average reduced temperature difference: this allows to represent the comparative characteristics of the two collectors when operating under variable conditions, especially with wide range of incidence angles. (author)
The use of transverse burnishing by means of flat plates for combined finishing and strengthening of cylindrical parts is considered. The influence of the compressive strain and the total number of workpiece rotations on the surface roughness is determined experimentally.
The thermofluid process inside the tube of flat-plate collectors is complex because the non-uniform heating of the tube results in the formation of stably and unstably stratified layers of fluid that interact with each other. The measurement and investigation of the flow behaviour inside the collector tube is very challenging. We report on a novel application of the particle image velocimetry (PIV) technique to remotely measure the velocity field inside the collector tube. The two-dimensional velocity fields were measured in the midplane of a collector tube for the Reynolds number range of 150-900 at unheated and four different heating conditions. We have presented and discussed in detail the technique implementation and the associated challenges. The results have shown that the collector heating significantly alters the structure and magnitude of the mean velocity field and influences the heat transfer to the fluid. It is observed that the collector heating causes a significant asymmetry in the mean velocity profiles over the given range of Reynolds numbers and heating conditions. (author)
This report was prepared for the General Services Administration by the National Renewable Energy Laboratory. The Honeycomb Solar Thermal Collector (HSTC) is a flat plate solar thermal collector that shows promising high efficiencies over a wide range of climate zones. The technical objectives of this study are to: 1) verify collector performance, 2) compare that performance to other market-available collectors, 3) verify overheat protection, and 4) analyze the economic performance of the HSTC both at the demonstration sites and across a matrix of climate zones and utility markets.
An experimental investigation of wavy water film falling down a flat plate has been carried out using confocal chromatic sensoring technique to determine the instantaneous and statistical characteristics of the film. The experiments involved three parameters: liquid feed mode, Reynolds number and plate inclination angle. The present time-average film thickness data is compared with the previous experimental and theoretical results showing a good agreement. A new correlation for the average film thickness is suggested. Our results show that the liquid feed mode has a vital influence on the film thickness and that the film thickness increases with Reynolds number and decreased plate inclination angle. The root-mean-square value of the film thickness fluctuations depends non-monotonically on the film Reynolds number. The corresponding mechanisms are analyzed. (author)
The main provisions of the developed numerical unsteady model of the flat plate solar collector–storage tank (SC–ST) system are given. The model takes into account all of the main parameters of the SC (receiver parameters, radiative properties of the transparent fence for solar radiation, and thermophysical properties of the thermal insulation of the bottom) and the ST (thermophysical parameters of thermal insulation). An algorithm and a program for calculating the thermal properties of a closed SC–ST system have been developed based on this model in the Delphi language. The results of the calculated estimates of the time variation of water heating temperatures in the ST and the efficiency of the closed SC–ST system as a function of the ST volume are given for the case where the water temperature at the SC inlet is equal to the mean water temperature in the ST. The model and the program also make it possible to determine the time variation of temperatures of SC elements and water in individual sections along the length of the SC as well as the thermal losses of the SC sections. The model makes it possible to estimate the effect of the thermal properties of SC elements and the water velocity on the thermal properties of the SC–ST system. The program can be modified for the case of the open SC–ST system, i.e., where the water temperature at the SC inlet does not depend on the water temperature in the ST.
The current work represents the simulation results of the thermal performances of flat-plate solar collector with heat transfer fluid–nanofluid (SiO{sub 2} + water with 5% concentration) which is obtained experimentally [1]. The dependence of the outlet temperature and gained useful energy of heat transfer fluid (nanofluid) on the flow rates (10, 15 and 20 L/h) at different ranges of incident solar radiation (500–1000 W/m{sup 2}) was obtained.
Various helium (He)-cooled solid-tungsten (W) divertor concepts have been proposed for long-pulse magnetic fusion energy reactors. Among these concepts, the He-cooled flat plate divertor (HCFP) modules have the largest plasma-facing surface area of ~0.2 m 2 . Simulations have shown that the most recent version of the design can withstand heat fluxes as great as 8 MW/m 2 . Earlier experimental studies of a single shortened HCFP cooling unit with a slot length of 7.6 cm used air at ambient temperature and pressures below 0.6 MPa. Here, we present initial experimental studies of a copper alloy and steel test section modeling a shortened HCFP cooling unit using He at prototypical pressure of 10 MPa, inlet temperatures T i ≤ 200 °C and steady-state incident heat fluxes q" ≤ 1.2 MW/m 2 . Results for Nusselt number Nu as a function of Reynolds number Re were obtained for Re = 1.2×10 4 –3.4×10 4 , and used to develop a Nu(Re) correlation and validate numerical models of the test section using commercial computational fluid dynamics (CFD) software. Simulations with this model are performed to evaluate the effect of the shortened slot. Furthermore, these analyses are used to estimate the thermal-fluids performance of the HCFP under prototypical conditions.
It has been proposed to introduce a new parameter into the practice of the heat calculation and testing of the flat-plate solar water-heating collectors (FSWHCs)—the coefficient of heat transfer from the light-absorbing panel (LAP) to the heat transfer fluid in its internal heat-exchange channels (HECs) reduced to the unit area of the frontal surface of their cases. The mechanism of the formation of this parameter is studied, the design expression is derived, and a practical example of the calculation to define its value is performed. The structures of the flowing LAPs of a sheet-piped thin parallelepiped form are selected as the objects of the investigation. The reliability of the results of the investigations is proved by comparing the values of the specific (relative to the area unit of the frontal surface of the case) heating efficiency of the collector obtained based on the various formulas.