Search NASASearch

SEARCH · Search NASA

Results for “FLOW OF GASES - JETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Spark ignition of flowing gases

Research conducted at the NACA Lewis Laboratory on ignition of flowing gases by means of long-duration discharges is summarized and analyzed. Data showing the effect of a flowing combustible mixture on the physical and electrical characteristics of spark discharges and data showing the effects of variables on the spark energy required for ignition that has been developed to predict the effect of many of the gas-stream and spark variables is described and applied to a limited amount of experimental data.

Swett, Clyde C , Jr

Spark Ignition of Flowing Gases. 2: Effect of Electrode Parameters on Energy Required to Ignite a Propane-Air Mixture

Research was conducted to determine the effect of the electrode parameters of spacing, configuration, and material' on the energy required for ignition of a flowing propane-air mixture. In addition, the data were used to indicate the energy distribution along the spark length and to confirm previous observations concerning the effect of spark duration on ignition energy requirements. The data were obtained with a mixture at a fuel-air ratio of 0.0835 (by weight), a pressure of 3 inches of mercury absolute, a temperature of 80 F, and a mixture velocity of 5 feet per second. Results showed that the energy required for ignition decreased as the electrode spacing was increased; a minimum energy occurred at. a spacing of 0.65 inch for large electrodes. For small electrodes, the spacing for minimum energy was not sharply defined. Small-diameter electrodes required less energy than large-diameter electrodes if the spacing was less than the optimum distance of 0.65 inch; at a spacing equal to the optimum distance, no difference was noted. Significant effects of electrode material on ignition energy were ascribed to differences in the type of spark discharges produced; glow discharges required higher energy than the arc-glow discharges. With pure glow discharges, the ignition energy was substantially constant for lead, cadmium, brass, aluminum, and tungsten electrodes. A method is described for determining the energy distribution along a glow discharge. It was found that one-third to one-half of the energy in the spark was concentrated in a small region near the cathode electrode, and the remainder was uniformly distributed across the spark gap. It was impossible to ascertain the dependence of ignition on. this distribution. It was also observed that long-duration (600 microsec) sparks required much less energy for ignition than did short-duration (1 microsec) sparks.

Swett, Clyde. C., Jr.

The Flow of Gases in Narrow Channels

Measurements were made of the flow of gases through various narrow channels a few microns wide at average pressures from 0.00003 to 40 cm. Hg. The flow rate, defined as the product of pressure and volume rate of flow at unit pressure difference, first decreased linearly with decrease in mean pressure in the channel, in agreement with laminar-flow theory, reached a minimum when the mean path length was approximately equal to the channel width, and then increased to a constant value. The product of flow rate and square root of molecular number was approximately the same function of mean path length for all gases for a given channel.

FLOW, LAMINAR

Non-isothermal laminar flow of gases through cooled tubes.

Numerical solutions of the laminar-flow equations in differential form are presented for gas flows through cooled tubes. For nearly isothermal flow there is good agreement with available experimental data, as is also found for the case of a large amount of wall cooling. This correspondence along with a check on the satisfaction of the global momentum and energy constraints allowed an appraisal of the effect of wall cooling on flow through tubes. In general, the effect of wall cooling was to decrease the wall friction and the change in pressure along tubes, but the average heat-transfer coefficient did not vary much.

Back, L. H.