Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Electron Target Cooling Analyses of the KIPT ADS Using MCNP and Ansys Fluent

This study presents multiphysics analyses of the electron target cooling system of the accelerator-driven system (ADS) of the Kharkiv Institute of Physics and Technology (KIPT) using MCNP and Fluent computer programs. MCNP has been used to transport electrons, gammas, and neutrons, and to calculate the energy deposition in the target materials. The MCNP mesh-tally data have been imported into Fluent by a C subroutine that has been compiled and linked to Fluent as a user-defined function.The KIPT ADS is located in Ukraine and was in operation until February 2022. The Fluent model is based on the computer-aided design files from the manufacturing process of the target assembly. Here, the Fluent results for the reference case match very well the literature results obtained by STAR-CCM+ during the design phase. Other cases that differ from the reference one have been analyzed; in these cases, it is assumed a malfunction of the electron accelerator or of the water cooling system. The target cooling system operates normally for all the analyzed cases except when the inlet water mass flow rate is decreased. The transient analysis showed that the target cooling system can operate for 180 s with full power when the inlet water mass flow rate is decreased down by 75%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Implementation of tritium transport in a gas-liquid contactor CFD simulation of tritium extraction from lead-lithium in ANSYS fluent

Modifications to the Computational Fluid Dynamic (CFD) software ANSYS Fluent were done to quantify and characterize tritium transport in Gas-Liquid Contactors (GLCs). A double-slit, Ergun-like equation was employed for the porous media model, with Ergun coefficients validated with Sulzer’s Sulcol software. Tritium transport from PbLi within the GLC was verified against analytical models. The geometry of the CFD model was based on the MELODIE GLC experiment. The hydrodynamic CFD pressure drop results align well with SulCol estimations and fall between the predictions of the analytical Delft-Olujic and Billet & Schultes models. In terms of mass transfer efficiency, traditional mass transfer models showed a significant deviation from experimental results when using varying values of H solubility in PbLi. A saturation phenomenon occurred when utilizing high solubility values for hydrogen in PbLi. In conclusion, a modified film theory mass transfer coefficient, incorporating either the Delft-Olujic or Billet & Schultes wettability model, yielded CFD-predicted extraction efficiencies that closely matched experimental measurements.

70 - PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ANSYS Fluent CFD Modeling of Solar Air-Heater Thermoaerodynamics

Numerical modeling of thermal and aerodynamic processes taking place in a solar air heater with light-absorbing L-shaped fins is performed. The study is carried out by means of an ANSYS Fluent Solver with an integrated solar calculator for the city of Samara, Russia. The influence of the design (the step between the fins) and technological variables (the Reynolds number) on heat-exchange processes and flow aerodynamics was established during the CFD analysis. Pictorial contours are determined for the velocity distribution, pressure, and other characteristics of the airflow in the solar air-heater box. Thermoaerodynamic characteristics and effective values of technological parameters for the effective use of a solar air heater are studied. The maximum thermoaerodynamic characteristic for the solar air heater with a finned lightabsorbing surface is 1.91 for Re = 1500, and the minimum test fin pitch is 30 mm.

42 ENGINEERING↗

Glovebox CFD Analysis: Low-Flow, Laminar CFD Analysis of Glovebox Ventilation and Humidity Transport in Ansys Fluent 2025 R1

There are gloveboxes that frequently exceed the 30% relative humidity level required for operations. These exceedances result in alternative operations needing to be utilized. This report documents a computational fluid dynamics (CFD) analysis performed to characterize airflow and humidity transport within a representative glovebox under nominal, low-flow conditions. The analysis focuses on establishing the flow regime, identifying transport-limited regions, and evaluating the implications of laminar flow on humidity removal. A single-phase, laminar flow model with a species transport model was used to represent air and water vapor mixing. Results demonstrate that, at the nominal flow rates, airflow is laminar with weak mixing, which will result in long residence times, tens of minutes long or more, in low-velocity regions. These conclusions suggests that humidity reduction is transport-limited. This analysis provides qualitative insight into airflow structure and humidity transport trends. In addition to characterization of glovebox airflow and humidity transport, results are intended to inform experimental validation and future transient modeling efforts.

42 ENGINEERING↗

Multi-Phase CFD Modeling of Solid Sorbent Carbon Capture System

Computational fluid dynamics (CFD) simulations are used to investigate a low temperature post-combustion carbon capture reactor. The CFD models are based on a small scale solid sorbent carbon capture reactor design from ADA-ES and Southern Company. The reactor is a fluidized bed design based on a silica-supported amine sorbent. CFD models using both Eulerian-Eulerian and Eulerian-Lagrangian multi-phase modeling methods are developed to investigate the hydrodynamics and adsorption of carbon dioxide in the reactor. Models developed in both FLUENT® and BARRACUDA are presented to explore the strengths and weaknesses of state of the art CFD codes for modeling multi-phase carbon capture reactors. The results of the simulations show that the FLUENT® Eulerian-Lagrangian simulations (DDPM) are unstable for the given reactor design; while the BARRACUDA Eulerian-Lagrangian model is able to simulate the system given appropriate simplifying assumptions. FLUENT® Eulerian-Eulerian simulations also provide a stable solution for the carbon capture reactor given the appropriate simplifying assumptions.

Ryan, Emily M.↗

KIPT ADS Target Cooling Analyses by MCNP/Fluent

This report presents multi-physics analyses of the target cooling system of the accelerator driven system (ADS) of the Kharkiv Institute of Physics and Technology (KIPT) using MCNP and Fluent computer programs. MCNP has been used to transport electrons, gammas, and neutrons, and to calculate the energy deposition in the target using a mesh-tally. The mesh-tally data have been imported in Fluent by a C subroutine that has been compiled and linked to Fluent as a user defined function. The KIPT ADS is in operation and Fluent used the CAD model from the manufacturing process of the target. The Fluent results for the reference case match very well the literature results obtained by STAR-CCM+ during the design phase. Other cases that differ from the reference one have been analyzed; in these cases, it is assumed a malfunction of the electron accelerator control or the primary water coolant pump. The target cooling system operates normally for all the analyzed cases except when the inlet water mass flow rate is decreased. If the water coolant mass flow decreases to 25%, the water maximum temperature exceeds the boiling point. However, the transient analysis showed that the target cooling system can operate for 180 seconds when the inlet water mass flow rate is decreased down by 50%.

42 ENGINEERING↗

Micro Reactor Simulation Using the PROTEUS Suite in FY19

Two micro reactor cores were simulated using the MOC solver of PROTEUS: MegaPower for a heat pipe micro reactor and Holos-Quad for a high-temperature gas-cooled micro reactor. Verification of PROTEUS standalone was performed by simulating 2D and 3D core benchmark problems developed based on MegaPower and Holos-Quad. Simulation results indicated that PROTEUS successfully modelled 2D and 3D cores of the MegaPower and Holos-Quad micro reactors and PROTEUS eigenvalues agreed well with the SERPENT Monte Carlo solutions. For a heat pipe cooled micro reactor, multiphysics simulations were performed using PROTEUS / FLUENT / ANLHTP. The coupling system of the three codes were developed using Python-based drivers, which exchange the data (power, temperature, and heat rate) required for the coupling and control the boundary conditions of FLUENT and ANLHTP. The coupled system was qualitatively verified using a 3D unit assembly problem composed of six fuel rods and seven heat pipes, which was developed based on the MegaPower compositions. The steady-state problem was solved using FLUENT / ANLHTP with given asymmetric fuel powers, demonstrating the reasonable convergence of temperatures of 7 heat pipes. Transient simulations were also performed by making one out of 7 heat pipes fail. For the transient, the coupled system of PROTEUS / FLUENT / ANLHTP demonstrated reasonable changes of total power and heat pipe temperatures with time, accounting for temperature feedback effects. In this simulation, no effect of structural change was accounted for, which will be performed using ANSYS-mechanical in future along with further verification with larger or whole-core 3D problems.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

TRUST Sensors in Environments: Thermocouples (SE-TC), Release FY25

The Delivery Environments Testbeds to Reduce Uncertainty in Simulations and Tests (TRUST) project is a broad project intended to analyze simplified problems experimentally and with modeling and simulation. The purpose of analyzing these simplified problems is to extend solution methods to more complex problems, as well as understand deficiencies and gaps in knowledge of methods currently used in more complex analyses. The TRUST project encompasses several smaller testbeds intended to isolate individual phenomena. The testbed under consideration in this report is the Sensors in Environments: Thermocouples testbed. In previous years, the purpose of this testbed was to quantify uncertainty of thermocouple sensors. To accomplish this, an aluminum plate was placed in a thermal chamber and subject to various types of thermal loading. Thermocouples were placed in various locations on the aluminum plate in various configurations (e.g., embedded in the plate, placed under Kapton tape), and an effort was made to quantify uncertainty in these measurements. Finite element simulations were performed to investigate how sensitive these measurements were to parameters such as the boundary conditions on the plate and material properties. However, a fundamental source of uncertainty in this analysis was the convective heat transfer from the plate. Convective heat transfer is a complex physical phenomenon comprised of a number of interacting sub-processes and is difficult to predict accurately a priori. As such, the main purpose of this testbed in FY25 was to better understand, both experimentally and numerically, the convective heat transfer from the plate. This is a highly applicable problem to several more complex problems, as convective heat transfer occurs in nearly all problems where a body is moving through air. Numerically, this required a two-step approach. First, the air flow in the thermal chamber was in vestigated using computational fluid dynamics. The commercial solver Fluent was used to perform these simulations. From these simulations, a heat transfer coefficient over the surface of the plate was calculated. This heat transfer was then used as boundary conditions for finite element heat transfer simulations within the plate, which were performed using Abaqus. Significant effort was devoted to automating the handoff between these two solvers. Experimentally, previous thermocouple results in the plate were used to validate the time-dependent thermal profiles produced from Abaqus. Further experimental efforts were performed both to help validate the Fluent simulations and to inform its boundary conditions. For example, hot-wire anemometers were used to measure the velocity in the chamber, which would be particularly useful in understanding the chamber inlet velocity. Thermocouple measurements were also taken in the chamber, instead of only on the plate, to serve as validation evidence for the Fluent simulations. Numerical results showed that the Fluent to Abaqus workflow matched previous plate thermocouple measurements well. This type of handoff is useful for more complex experiments, or those that are not able to be examined in as great of detail as this testbed, as it was performed without any experimental input. Experimental results, however, were more mixed. The anemometers proved unreliable, with inconsistent measurements across all anemometers, even at locations that were nearly identical. On the other hand, the thermocouples provided a relatively rich view of the temperature field in the chamber.

42 ENGINEERING↗

Porosity Prediction in A356 Wheel Casting

A FLUENT™-based thermal-fluid-compositional model has been developed and applied to a low-pressure, die-cast, A356 aluminum alloy wheel to explore the effects of macro-segregation of hydrogen and late-stage liquid encapsulation on pore formation during solidification. Based on the evolution of temperature, pressure, and hydrogen concentration in the liquid output from FLUENT, the porosity size distribution has been predicted at a number of locations in a commercially produced wheel using an in-house micro-porosity model. The porosity model incorporates pore nucleation kinetics based on hydrogen supersaturation, and two modes of pore growth: the first, occurring at low solid fractions is based on hydrogen diffusion; and the second, occurring at high solid fractions is based on conservation of volume. Samples from a commercially cast wheel have been analyzed using X-ray micro-tomography to provide basic validation of the micro-porosity model. The predicted results showed that the evolution in pressure has the dominant effect on pore growth, but only under conditions where pores have nucleated prior to late-stage liquid encapsulation. Otherwise, the cooling rate appears to have the dominant effect. The accuracy of the model is discussed in terms of the predicted pore size distribution and number density of pores. Areas for continued development are presented.

36 MATERIALS SCIENCE↗

Coupled modeling of a directly heated tubular solar receiver for supercritical carbon dioxide Brayton cycle: Optical and thermal-fluid evaluation

In single phase performance and appealing thermo-physical properties supercritical carbon dioxide (s-CO 2 ) make a good heat transfer fluid candidate for concentrating solar power (CSP) technologies. The development of a solar receiver capable of delivering s-CO 2 at outlet temperatures ~973 K is required in order to merge CSP and s-CO 2 Brayton cycle technologies. A coupled optical and thermal-fluid modeling effort for a tubular receiver is undertaken to evaluate the direct tubular s-CO 2 receiver’s thermal performance when exposed to a concentrated solar power input of ~0.3–0.5 MW. Ray tracing, using SolTrace, is performed to determine the heat flux profiles on the receiver and computational fluid dynamics (CFD) determines the thermal performance of the receiver under the specified heating conditions. Moreover, an in-house MATLAB code is developed to couple SolTrace and ANSYS Fluent. CFD modeling is performed using ANSYS Fluent to predict the thermal performance of the receiver by evaluating radiation and convection heat loss mechanisms. Understanding the effects of variation in heliostat aiming strategy and flow configurations on the thermal performance of the receiver was achieved through parametric analyses. Finally, a receiver thermal efficiency ~85% was predicted and the surface temperatures were observed to be within the allowable limit for the materials under consideration.

54 ENVIRONMENTAL SCIENCES↗

Quantitative characterization of arc discharge as vacuum interface

An arc discharge with channel diameters of 3 mm and 6 mm and lengths between 30mm and 60mm was experimentally investigated for its potential to function as plasma window, i.e., interface vacuum regions of different pressures. In this study, electron temperature of the plasma channel measured spectroscopically varied in the range of 7000K to 15000K, increasing with discharge current while decreasing with gas flow rate. The plasma window had a slightly positive I-V characteristics over the whole range of investigated current 30A–70 A. Measurements of pressure separation capability, which were determined by input current, gas flow rate, discharge channel diameter, and length, were well explained by viscosity effect and “thermal-block” effect. The experimental results of global parameters including temperature, gas flow rate, and voltage had a good agreement with the simulation results calculated by an axis-symmetry Fluent-based magneto-hydrodynamic model.

43 PARTICLE ACCELERATORS↗

Parametric study of natural circulation flow in molten salt fuel in molten salt reactor

The Molten Salt Reactor (MSR) is one of the most promising system proposed by Generation IV Forum (GIF) for future nuclear reactor systems. Advantages of the MSR are significantly larger compared to other reactor system, and is mainly achieved from its liquid nature of fuel and coolant. Further improvement to this system, which is a natural circulating molten fuel salt inside its tube in the reactor core is proposed, to achieve advantages of reducing and simplifying the MSR design proposed by GIF. Thermal hydraulic analysis on the proposed system was completed using a commercial computation fluid dynamics (CFD) software called FLUENT by ANSYS Inc. An understanding on theory behind this unique natural circulation flow inside the tube caused by fission heat generated in molten fuel salt and tube cooling was briefly introduced. Currently, no commercial CFD software could perfectly simulate natural circulation flow, hence, modeling this flow problem in FLUENT is introduced and analyzed to obtain best simulation results. Results obtained demonstrate the existence of periodical transient nature of flow problem, hence improvements in tube design is proposed based on the analysis on temperature and velocity profile. Results show that the proposed system could operate at up to 750MW core power, given that turbulence are enhanced throughout flow region, and precise molten fuel salt physical properties could be defined. At the request of the authors and the Proceedings Editor the name of the co-author Andrea Cioncolini was corrected from Andrea Coincolini. The same name correction was made in the Acknowledgement section on page 030004-10 and in reference number 4. The updated article was published on 11 May 2015.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Theoretical and experimental investigation on magneto-hydrodynamics of plasma window

As a new device, plasma window has been designed to use plasma discharge to separate atmosphere from vacuum with high difference of pressure. It has many excellent properties, being able to be used as available passage for ion beam with negligible energy loss, also impervious to radiation damage and thermal damage. Normally beam focusing by accelerators is not that easy to achieve within channel of small cross section. 10 mm diameter plasma window's experimental realization could contribute to its further application in accelerator system. In this paper, 10 mm diameter 60 mm long plasma window has first been designed and managed to generate arc discharge with argon gas experimentally. The result proves that it has the ability to separate at least 28.8 kPa (not the upper limit) from 360 Pa with 50 A direct current and 2.5 kW power supplied. Current increase leads to linear inlet pressure increase obviously, while it has less impact on outlet pressure and voltage, coming to the conclusion that the higher current of plasma discharge, the larger pressure difference it creates. Theoretical analysis of 10 mm diameter plasma window in axis symmetrical configuration using argon also has been provided, in which a numerical 2D FLUENT-based magneto-hydrodynamic simulation model is settled. It has a good agreement with experimental result on voltage and mass flow rate when inlet pressure is increased.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗