At least 19 records

Nuclear Data Sheets for A = 27

Evaluated spectroscopic data and level schemes from radioactive decay and nuclear reaction studies are presented for {sup 27}F, {sup 27}Ne, {sup 27}Na, {sup 27}Mg, {sup 27}Al, {sup 27}Si, {sup 27}P, and {sup 27}S. This evaluation for A=27 supersedes the earlier evaluation by P.M. Endt (1998En04 and 1990En08).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mechanochemical synthesis of low-fluorine doped aluminum hydroxide fluorides

Different aluminum hydroxide fluorides with varying Al/F molar ratios from 1:1.5 up to 1:0.05 were successfully synthesized by mechanochemical reactions. The characterization of the products by XRD, {sup 27}Al and {sup 19}F MAS NMR, thermal analysis, nitrogen adsorption and zeta potential techniques allows a detailed understanding of the structure and surface properties of the products. Using γ-Al(OH){sub 3} and β-AlF{sub 3}·3H{sub 2}O as OH- and F-sources, respectively, strongly disordered products were obtained with an Al: F molar ratio higher than 1:0.25. The fluorination degree has affected the amount of 4- and 5-fold coordinated Al sites, not present in the reactants. An evolution of the sub-coordinated Al-species has been detected also as a consequence of annealing processes. Obviously, these species affect the phase transition to alumina, by decreasing the transition temperature of the formation of α-Al{sub 2}O{sub 3}. Synthesis conditions (milling time, fluorination degree) play a crucial role for the product composition. - Graphical abstract: The impact of the combined action of the milling and the different fluorine doping on the structure of new aluminum hydroxide fluorides was followed by {sup 27}Al and {sup 19}F NMR and by other complementary techniques. - Highlights: • Low F-doped Al-hydroxide fluorides can be successfully prepared by mechanosynthesis. • Both F-doping and mechanochemical synthesis introduce a high number of defects in the structure. • The fluorination degree affects the amount of 4- and 5-fold coordinated Al sites as well as the transition temperature to corundum.

36 MATERIALS SCIENCE↗

Structure resolution of Ba{sub 5}Al{sub 3}F{sub 19} and Iivestigation of fluorine ion dynamics by synchrotron powder diffraction, variable-temperature solid-state NMR, and quantum computations.

The room temperature structure of Ba{sub 5}Al{sub 3}F{sub 19} has been solved using electron microscopy and synchrotron powder diffraction data. One-dimensional (1D) {sup 27}Al and ultrafast magic-angle-spinning (MAS) {sup 19}F NMR spectra have been recorded and are in agreement with the proposed structural model for Ba{sub 5}Al{sub 3}F{sub 19}. The {sup 19}F isotropic chemical shift and {sup 27}Al quadrupolar parameters have been calculated using the CASTEP code from the experimental and density functional theory geometry-optimized structures. After optimization, the calculated NMR parameters of both the {sup 19}F and {sup 27}Al nuclei show improved consistency with the experimental values, demonstrating that the geometry optimization step is necessary to obtain more accurate and reliable structural data. This also enables a complete and unambiguous assignment of the {sup 19}F MAS NMR spectrum of Ba{sub 5}Al{sub 3}F{sub 19}. Variable-temperature 1D MAS {sup 19}F NMR experiments have been carried out, showing the occurrence of fluorine ion mobility. Complementary insights were obtained from both two-dimensional (2D) exchange and 2D double-quantum dipolar recoupling NMR experiments, and a detailed analysis of the anionic motion in Ba{sub 5}Al{sub 3}F{sub 19} is proposed, including the distinction between reorientational processes and chemical exchange involving bond breaking and re-formation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Asymptotic normalization of mirror states and the effect of couplings

Assuming that the ratio between asymptotic normalization coefficients of mirror states is model independent, charge symmetry can be used to indirectly extract astrophysically relevant proton capture reactions on proton-rich nuclei based on information on stable isotopes. The assumption has been tested for light nuclei within the microscopic cluster model. In this work we explore the Hamiltonian independence of the ratio between asymptotic normalization coefficients of mirror states when deformation and core excitation is introduced in the system. For this purpose we consider a phenomenological rotor+N model where the valence nucleon is subject to a deformed mean field and the core is allowed to excite. We apply the model to {sup 8}Li/{sup 8}B, {sup 13}C/{sup 13}N, {sup 17}O/{sup 17}F, {sup 23}Ne/{sup 23}Al, and {sup 27}Mg/{sup 27}P. Our results show that, for most studied cases, the ratio between asymptotic normalization coefficients of mirror states is independent of the strength and multipolarity of the couplings induced. The exception is for cases in which there is an s-wave coupled to the ground state of the core, the proton system is loosely bound, and the states have large admixture with other configurations. We discuss the implications of our results for novae.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Molecular Level Understanding of the Interactions Between Reaction Intermediates of Li–S Energy Storage Systems and Ether Solvents

The lithium–sulfur energy storage system has the potential to deliver high energy density for grid and transportation applications. Lithium polysulfides (LiPS) formed during the chemical transformation of elemental sulfur can be reactive toward commonly used ether solvents. In this chapter, using density functional theory calculations, we address kinetic and thermodynamic feasibilities of LiPS reactions with various ether molecules (linear and cyclic) and fluorine-substituted ether molecules to understand their long-term chemical stability as solvents or cosolvents. These a priori computations indicate that the most reactive intermediates that initiate a likely degradation reaction of ether solvent molecules are Li2S2, Li2S3, Li2S4, and S2 2−. The lowest computed activation barriers (ΔH ‡) for the CO bond cleavage of dimethoxy ethane (DME) by shorter chain polysulfides or sulfide anions are in the range of ∼27–35 kcal mol−1, suggesting extremely slow kinetics for a polysulfide-induced ether solvent degradation. Calculations are extended to nine more linear and cyclic ether solvent molecules including the glymes, tetrahydrofuran (THF), and dioxolane (DOL). Computations suggest that the solvent stability is higher for shorter chain linear ethers compared to longer chain linear ethers and cyclic ethers. In addition to the 10 ether solvent candidates, simulations were also performed to understand the kinetic stability of 16 fluorinated DME molecules – a model for fluorinated ether species. Computations show that the introduction of one or more CF bond(s) in linear ether molecules enables nucleophilic attack by the polysulfide species, especially toward the polar CF/CO bonds. The CO bond stability of the fluoroether molecule was also compromised by the presence of the highly electron-withdrawing “−F” functional group. In general, in this chapter, utilizing the predictive power of first principle simulations, the LiPS reactivity toward ether solvent molecules was simulated and likely reactions that cause degradation are discussed. These studies also provide guidelines for the design of electrolyte systems with longer term chemical stability.

Assary, Rajeev S.↗

Formation of a Strong Heterogeneous Aluminum Lewis Acid on Silica

Abstract Al(OC(CF 3 ) 3 )(PhF) reacts with silanols present on partially dehydroxylated silica to form well‐defined ≡SiOAl(OC(CF 3 ) 3 ) 2 (O(Si≡) 2 ) ( 1 ). 27 Al NMR and DFT calculations with a small cluster model to approximate the silica surface show that the aluminum in 1 adopts a distorted trigonal bipyramidal coordination geometry by coordinating to a nearby siloxane bridge and a fluorine from the alkoxide. Fluoride ion affinity (FIA) calculations follow experimental trends and show that 1 is a stronger Lewis acid than B(C 6 F 5 ) 3 and Al(OC(CF 3 ) 3 )(PhF) but is weaker than Al(OC(CF 3 ) 3 ) and i Pr 3 Si + . Cp 2 Zr(CH 3 ) 2 reacts with 1 to form [Cp 2 ZrCH 3 ][≡SiOAl(OC(CF 3 ) 3 ) 2 (CH 3 )] ( 3 ) by methide abstraction. This reactivity pattern is similar to reactions of organometallics with the proposed strong Lewis acid sites present on Al 2 O 3 .

Samudrala, Kavyasripriya K.↗

Formation of a Strong Heterogeneous Aluminum Lewis Acid on Silica

Abstract Al(OC(CF 3 ) 3 )(PhF) reacts with silanols present on partially dehydroxylated silica to form well‐defined ≡SiOAl(OC(CF 3 ) 3 ) 2 (O(Si≡) 2 ) ( 1 ). 27 Al NMR and DFT calculations with a small cluster model to approximate the silica surface show that the aluminum in 1 adopts a distorted trigonal bipyramidal coordination geometry by coordinating to a nearby siloxane bridge and a fluorine from the alkoxide. Fluoride ion affinity (FIA) calculations follow experimental trends and show that 1 is a stronger Lewis acid than B(C 6 F 5 ) 3 and Al(OC(CF 3 ) 3 )(PhF) but is weaker than Al(OC(CF 3 ) 3 ) and i Pr 3 Si + . Cp 2 Zr(CH 3 ) 2 reacts with 1 to form [Cp 2 ZrCH 3 ][≡SiOAl(OC(CF 3 ) 3 ) 2 (CH 3 )] ( 3 ) by methide abstraction. This reactivity pattern is similar to reactions of organometallics with the proposed strong Lewis acid sites present on Al 2 O 3 .

Samudrala, Kavyasripriya K.↗

Density matrix renormalization group description of the island of inversion isotopes F 28 – 33

Recent experiments have confirmed that the neutron-rich isotopes 28,29 F belong to the so-called island of inversion (IOI), a region of the nuclear chart around Z = 10 and N = 20 where nuclear structure deviates from the standard shell model predictions due to deformation and continuum effects. However, while the general principles leading to the IOI are relatively well understood, the details of the low-lying structure of the exotic fluorine isotopes 28–33 F are basically unknown. In this study, we perform large-scale shell model calculations including continuum states to investigate the properties of the neutron-rich isotopes 25–33 F, from a core of 24 O and using an effective two-body interaction with a small number of adjustable parameters in the central and tensor channels. We develop two models adjusted on experimentally confirmed states in 25,26 O and 25–27 F based on different assumptions concerning the positions of the neutron 0d 3/2 and 1p 3/2 shells, and solve the many-body problem using the density matrix renormalization group (DMRG) method for open quantum systems in an sd–fp model space. We obtain the first detailed spectroscopy of 25–33F in the continuum and show how the interplay between continuum effects and deformation explains the recent data on 28,29 F. Several deformed one- and two-neutron halo states are predicted in 29,31 F, and we provide some information about the possible structure of the heaviest fluorine isotopes. We also suggest several experimental studies of interest to constraint models and test the present predictions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Structure investigation of fluorinated aluminophosphate ULM-3 Al templated by 3-methylaminopropylamine

A single-crystal X-ray diffraction analysis of an open-framework aluminophosphate ULM-3 Al prepared by 3-methylaminopropylamine (MAPA) as structure-directing agent revealed an orthorhombic Pcab symmetry (a=9.9949(4) A, b=15.8229(7) A, c=18.1963(5) A, R=0.0648, Z=8, unit cell formula [Al{sub 24}P{sub 24}O{sub 96}F{sub 16}.C{sub 32}H{sub 112}N{sub 16}]), which differs from the Pbc2{sub 1} symmetry of the structural analogue prepared in the presence of 1,4-diaminobutane. The {sup 27}Al, {sup 31}P, {sup 19}F, {sup 13}C and {sup 1}H NMR investigations, which were performed to study in detail MAPA arrangement inside the framework as well as the interactions of MAPA with the aluminophosphate host, confirmed the crystal symmetry and the proposed hydrogen bonding scheme between the template and the framework. - Graphical abstract: The aluminophosphate analogue of open-framework gallophosphate ULM-3 was synthesized in the presence of 3-methylaminopropylamine. The Pcab crystal symmetry and hydrogen bonding scheme was determined by single-crystal X-ray diffraction and NMR spectroscopy.

36 MATERIALS SCIENCE↗

One-neutron knockout from light neutron-rich nuclei at relativistic energies

One-neutron knockout reactions from neutron-rich nuclei, with Z=6-13 and N=8-22, were studied at the Fragment Separator (GSI) at high beam energies, around 700 MeV/nucleon. Structural phenomena such as the formation of one-neutron halos in odd-mass carbon isotopes ({sup 15,17,19}C) will be discussed. In addition, one-neutron knockout measurements from {sup 22}N were carried out for the first time and demonstrate clearly the change from a 0d{sub 5/2} to a 1s{sub 1/2} orbital for the valence neutron, an effect that is expected above N=14 and that was also observed in {sup 23}O and {sup 24}F. The possibility of an anomalous structure of {sup 26}F, due to a significant 1s{sub 1/2} neutron admixture, will also be discussed in the light of the experimental data obtained in this work. Finally, the ground-state configuration of neutron-rich neon isotopes ({sup 24-28}Ne) was studied, providing new information in a region that is relatively close to the island of inversion.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-F-I-57: Evaluate and Optimize PET Acquisition Overlap in 18F-FDG Oncology Wholebody PET/CT: Can We Scan PET Faster?

Purpose: The longer patient has to remain on the table during PET imaging, the higher the likelihood of motion artifacts due to patient discomfort. This study was to investigate and optimize PET acquisition overlap in 18F-FDG oncology wholebody PET/CT to speed up PET acquisition and improve patient comfort. Methods: Wholebody 18F-FDG PET/CT of phantoms, 8 pre-clinical patients (beagles) and 5 clinical oncology patients were performed in 90s/bed on a time-of-flight Gemini TF 64 system. Imaging of phantoms and beagles was acquired with reduced PET overlaps (40%, 33%, 27%, 20%, 13% and no overlap) in addition to the system default (53%). In human studies, 1 or 2 reduced overlaps from the listed options were used to acquire PET/CT sweeps right after the default standard of care imaging. Image quality was blindly reviewed using visual scoring criteria and quantitative SUV assessment. NEMA PET sensitivity was performed under different overlaps. Results: All PET exams demonstrated no significant impact on the visual grades for overlaps >20%. Blinded reviews assigned the best visual scores to PET using overlaps 53%–27%. Reducing overlap to 27% for oncology patients (12-bed) saved an average of ∼40% acquisition time (11min) compared to using the default overlap (18min). No significant SUV variances were found when reducing overlap to half of default for cerebellum, lung, heart, aorta, liver, fat, muscle, bone marrow, thighs and target lesions (p>0.05), except expected variability in urinary system. Conclusion: This study demonstrated by combined phantom, pre-clinical and clinical PET/CT scans that PET acquisition overlap in axial of today’s systems can be reduced and optimized. It showed that a reduction of PET acquisition overlap to 27% (half of system default) can be implemented to reduce table time by ∼40% to improve patient comfort and minimize potential motion artifacts, without prominently degrading image quality or compromising PET quantification.

60 APPLIED LIFE SCIENCES↗

Using compressive sensing to recover images from PET scanners with partial detector rings

Purpose: Most positron emission tomography/computed tomography (PET/CT) scanners consist of tightly packed discrete detector rings to improve scanner efficiency. The authors’ aim was to use compressive sensing (CS) techniques in PET imaging to investigate the possibility of decreasing the number of detector elements per ring (introducing gaps) while maintaining image quality. Methods: A CS model based on a combination of gradient magnitude and wavelet domains (wavelet-TV) was developed to recover missing observations in PET data acquisition. The model was designed to minimize the total variation (TV) and L1-norm of wavelet coefficients while constrained by the partially observed data. The CS model also incorporated a Poisson noise term that modeled the observed noise while suppressing its contribution by penalizing the Poisson log likelihood function. Three experiments were performed to evaluate the proposed CS recovery algorithm: a simulation study, a phantom study, and six patient studies. The simulation dataset comprised six disks of various sizes in a uniform background with an activity concentration of 5:1. The simulated image was multiplied by the system matrix to obtain the corresponding sinogram and then Poisson noise was added. The resultant sinogram was masked to create the effect of partial detector removal and then the proposed CS algorithm was applied to recover the missing PET data. In addition, different levels of noise were simulated to assess the performance of the proposed algorithm. For the phantom study, an IEC phantom with six internal spheres each filled with F-18 at an activity-to-background ratio of 10:1 was used. The phantom was imaged twice on a RX PET/CT scanner: once with all detectors operational (baseline) and once with four detector blocks (11%) turned off at each of 0 °, 90 °, 180 °, and 270° (partially sampled). The partially acquired sinograms were then recovered using the proposed algorithm. For the third test, PET images from six patient studies were investigated using the same strategy of the phantom study. The recovered images using WTV and TV as well as the partially sampled images from all three experiments were then compared with the fully sampled images (the baseline). Comparisons were done by calculating the mean error (%bias), root mean square error (RMSE), contrast recovery (CR), and SNR of activity concentration in regions of interest drawn in the background as well as the disks, spheres, and lesions. Results: For the simulation study, the mean error, RMSE, and CR for the WTV (TV) recovered images were 0.26% (0.48%), 2.6% (2.9%), 97% (96%), respectively, when compared to baseline. For the partially sampled images, these results were 22.5%, 45.9%, and 64%, respectively. For the simulation study, the average SNR for the baseline was 41.7 while for WTV (TV), recovered image was 44.2 (44.0). The phantom study showed similar trends with 5.4% (18.2%), 15.6% (18.8%), and 78% (60%), respectively, for the WTV (TV) images and 33%, 34.3%, and 69% for the partially sampled images. For the phantom study, the average SNR for the baseline was 14.7 while for WTV (TV) recovered image was 13.7 (11.9). Finally, the average of these values for the six patient studies for the WTV-recovered, TV, and partially sampled images was 1%, 7.2%, 92% and 1.3%, 15.1%, 87%, and 27%, 25.8%, 45%, respectively. Conclusions: CS with WTV is capable of recovering PET images with good quantitative accuracy from partially sampled data. Such an approach can be used to potentially reduce the cost of scanners while maintaining good image quality.

60 APPLIED LIFE SCIENCES↗

{sup 18}F-FDG-PET in Finnish patients with clinical suspicion of cardiac sarcoidosis: Female sex and history of atrioventricular block increase the prevalence of positive PET findings

Introduction: Fluorodeoxyglucose positron emission tomography (FDG-PET) is a non-invasive imaging modality that has been shown to be a feasible method to demonstrate myocardial inflammation. The aim of this study was to identify the patients suspected of having cardiac sarcoidosis (CS), who are most likely to benefit from PET imaging. Materials and methods: 137 patients suspected of having CS underwent a dedicated cardiac FDG-PET examination at Tampere University Hospital between August 2012 and September 2015. These examinations were retrospectively analyzed. Results: 33 and 12 of the 137 patients had abnormal left and right ventricular (LV and RV) FDG-uptake, respectively. Abnormal LV-uptake and RV-uptake were significantly associated with female sex and a history of advanced AV-block (P < 0.05). Abnormal RV-uptake was also associated with ventricular tachycardia and atrial fibrillation (P < 0.05). 56% of the 27 female patients with a history of AV-block had a pathological PET finding compared to only 6% of the 49 male patients without a history of AV-block. There were 17 female patients with history of both AV-block and ventricular tachycardia, 71% of them had abnormal PET finding. Conclusions: Abnormal FDG-PET findings were associated with female sex, AV-block, and arrhythmias in this clinical cohort.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-303-01: Spatial Distribution of Bone Metastases In Metastatic Castrate-Resistant Prostate Cancer

Purpose: Identification of metastatic bone lesions is critical in prostate cancer, where treatments may be more effective in patients with fewer lesions. This study aims characterize the distribution and spread of bone lesions and create a probability map of metastatic spread in bone. Methods: Fifty-five metastatic castrate-resistant prostate cancer patients received up to 3 whole-body [F-18]NaF PET/CT scans. Lesions were identified by physician on PET/CT and contoured using a threshold of SUV>15. An atlas-based segmentation method was used to create CT regions, which determined skeletal location of lesions. Patients were divided into 3 groups with low (N<40), medium (40 100) numbers of lesions. A combination of articulated and deformable registrations was used to register the skeletal segments and lesions of each patient to a single skeleton. All the lesion data was then combined to make a probability map. Results: A total of 4038 metastatic lesions (mean 74, range 2–304) were identified. Skeletal regions with highest occurrence of lesions included ribs, thoracic spine, and pelvis with 21%, 19%, and 15% of the total number lesions and 8%, 18%, and 31 % of the total lesion volume, respectively. Interestingly, patients with fewer lesions were found to have a lower proportion of lesions in the ribs (9% in low vs. 27% in high number of lesions). Additionally, the probability map showed specific areas in the spine and pelvis where over 75% of patients had metastases, and other areas in the skeleton with a less than 2% of metastases. Conclusion: We identified skeletal regions with higher incidence of metastases and specific sub-regions in the skeleton that had high or low probability of occurrence of metastases. Additionally, we found that metastatic lesions in the ribs and skull occur more commonly in advanced disease. These results may have future applications in computer-aided diagnosis. Funding from the Prostate Cancer Foundation.

60 APPLIED LIFE SCIENCES↗

Effects of configurational changes on molecular dynamics in polyvinylidene fluoride and poly(vinylidene fluoride-trifluoroethylene) ferroelectric polymers

Here, we present a comparative study of proton dynamics in unpoled non-ferroelectric polymer polyvinylidene fluoride (PVDF) and in its trifluoroethylene containing ferroelectric copolymer (with 70/30 molar proportion), using quasi-elastic neutron scattering. The neutron data reveal the existence of two distinct types of molecular motions in the temperature range investigated. Moreover, the slower motion, which is characterized in details here, is ascribed to protons jump diffusion along the polymeric carbon chains, while the faster motion could be attributed to localized rotational motion of methylene groups. At temperatures below the Curie point (T-c similar to 385 K) of the composite polymer, the slower diffusive mode experiences longer relaxation times in the ferroelectric blend than in the bare PVDF, although the net corresponding diffusion coefficient remains comparatively the same in both polymers with characteristic activation energy of E-A approximate to 27-33 kJ/mol. This arises because of a temperature dependent jump length r(0), which we observe to be effectively longer in the copolymer, possibly due to the formation of ordered ferroelectric domains below Tc. Above Tc, there is no appreciable difference in r(0) between the two systems. Our observation directly relates the known dependence of Tc on molar ratio to changes in r(0), providing fundamental insight into the ferroelectric properties of PVDF-based copolymers.

36 MATERIALS SCIENCE↗

SU-E-J-245: Sensitivity of FDG PET Feature Analysis in Multi-Plane Vs. Single-Plane Extraction

Purpose: Sensitivity of PET-derived texture features to reconstruction methods has been reported for features extracted from axial planes; however, studies often utilize three dimensional techniques. This work aims to quantify the impact of multi-plane (3D) vs. single-plane (2D) feature extraction on radiomics-based analysis, including sensitivity to reconstruction parameters and potential loss of spatial information. Methods: Twenty-three patients with solid tumors underwent [{sup 18}F]FDG PET/CT scans under identical protocols. PET data were reconstructed using five sets of reconstruction parameters. Tumors were segmented using an automatic, in-house algorithm robust to reconstruction variations. 50 texture features were extracted using two Methods: 2D patches along axial planes and 3D patches. For each method, sensitivity of features to reconstruction parameters was calculated as percent difference relative to the average value across reconstructions. Correlations between feature values were compared when using 2D and 3D extraction. Results: 21/50 features showed significantly different sensitivity to reconstruction parameters when extracted in 2D vs 3D (wilcoxon α<0.05), assessed by overall range of variation, Rangevar(%). Eleven showed greater sensitivity to reconstruction in 2D extraction, primarily first-order and co-occurrence features (average Rangevar increase 83%). The remaining ten showed higher variation in 3D extraction (average Range{sub var}increase 27%), mainly co-occurence and greylevel run-length features. Correlation of feature value extracted in 2D and feature value extracted in 3D was poor (R<0.5) in 12/50 features, including eight co-occurrence features. Feature-to-feature correlations in 2D were marginally higher than 3D, ∣R∣>0.8 in 16% and 13% of all feature combinations, respectively. Larger sensitivity to reconstruction parameters were seen for inter-feature correlation in 2D(σ=6%) than 3D (σ<1%) extraction. Conclusion: Sensitivity and correlation of various texture features were shown to significantly differ between 2D and 3D extraction. Additionally, inter-feature correlations were more sensitive to reconstruction variation using single-plane extraction. This work highlights a need for standardized feature extraction/selection techniques in radiomics.

60 APPLIED LIFE SCIENCES↗

Volumetric Modulated Arc Therapy Planning for Primary Prostate Cancer With Selective Intraprostatic Boost Determined by {sup 18}F-Choline PET/CT

Purpose: This study evaluated expected tumor control and normal tissue toxicity for prostate volumetric modulated arc therapy (VMAT) with and without radiation boosts to an intraprostatically dominant lesion (IDL), defined by {sup 18}F-choline positron emission tomography/computed tomography (PET/CT). Methods and Materials: Thirty patients with localized prostate cancer underwent {sup 18}F-choline PET/CT before treatment. Two VMAT plans, plan{sub 79} {sub Gy} and plan{sub 100-105} {sub Gy}, were compared for each patient. The whole-prostate planning target volume (PTV{sub prostate}) prescription was 79 Gy in both plans, but plan{sub 100-105} {sub Gy} added simultaneous boost doses of 100 Gy and 105 Gy to the IDL, defined by 60% and 70% of maximum prostatic uptake on {sup 18}F-choline PET (IDL{sub suv60%} and IDL{sub suv70%}, respectively, with IDL{sub suv70%} nested inside IDL{sub suv60%} to potentially enhance tumor specificity of the maximum point dose). Plan evaluations included histopathological correspondence, isodose distributions, dose-volume histograms, tumor control probability (TCP), and normal tissue complication probability (NTCP). Results: Planning objectives and dose constraints proved feasible in 30 of 30 cases. Prostate sextant histopathology was available for 28 cases, confirming that IDL{sub suv60%} adequately covered all tumor-bearing prostate sextants in 27 cases and provided partial coverage in 1 case. Plan{sub 100-105} {sub Gy} had significantly higher TCP than plan{sub 79} {sub Gy} across all prostate regions for α/β ratios ranging from 1.5 Gy to 10 Gy (P<.001 for each case). There were no significant differences in bladder and femoral head NTCP between plans and slightly lower rectal NTCP (endpoint: grade ≥ 2 late toxicity or rectal bleeding) was found for plan{sub 100-105} {sub Gy}. Conclusions: VMAT can potentially increase the likelihood of tumor control in primary prostate cancer while observing normal tissue tolerances through simultaneous delivery of a steep radiation boost to a {sup 18}F-choline PET-defined IDL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Positron Emission Tomography Scanning and Sentinel Node Biopsy in the Detection of Inguinal Node Metastases in Patients With Anal Cancer

Background: Inguinal lymph node metastases in patients with anal cancer are an independent prognostic factor for local failure and overall mortality. Inguinal lymph node status can be adequately assessed with sentinel node biopsy, and the radiotherapy strategy can subsequently be changed. We compared this technique vs. dedicated 18F-fluorodeoxyglucose positron emission tomography (PET) to determine which was the better tool for staging inguinal lymph nodes. Methods and Materials: In our department, 27 patients (9 men and 18 women) underwent both inguinal sentinel node biopsy and PET-CT. PET-CT was performed before treatment and then at 1 and 3 months after treatment. Results: PET-CT scans detected no inguinal metastases in 20 of 27 patients and metastases in the remaining 7. Histologic analysis of the sentinel lymph node detected metastases in only three patients (four PET-CT false positives). HIV status was not found to influence the results. None of the patients negative at sentinel node biopsy developed metastases during the follow-up period. PET-CT had a sensitivity of 100%, with a negative predictive value of 100%. Owing to the high number of false positives, PET-CT specificity was 83%, and positive predictive value was 43%. Conclusions: In this series of patients with anal cancer, inguinal sentinel node biopsy was superior to PET-CT for staging inguinal lymph nodes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗