Search NASA⌕ Search

SEARCH · Search NASA

Results for “FMD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Preliminary Evaluation of Commercial Off the Shelf (COTS) Packing Materials for Flight Medication Dispenser (FMD) Technology Development

With the advent of longer duration space missions, pharmaceutical use in space has increased. During the first 33 space shuttle missions, crew members took more than 500 individual doses of 31 different medications . Anecdotal reports from crew members described medications as generally "well tolerated" and "effective". However, reported use of increased medication doses and discrepancies in ground vs. flight efficacy may result from reduced potency or altered bioavailability due to changes in chemical and/or physical parameters of pharmaceutical stability. Based on preliminary results from a ground-based irradiation and an inflight study on pharmaceutical stability, three susceptible medications, Amoxicillin/Clavulanate and Sulfamethoxazole/trimethoprim antibiotics tablets and promethazine (PMZ), an antihistamine were selected for testing using two types of Oliver-Tolas bags, TPC-1475(Clear) and TPF-0599B (Foil) for radiation Shielding effectiveness. The material composition of the bags included aluminum coated Mylar sheathing coated with multifunctional nanocomposities based on polyethylene with dispersed boron-rich nanophases. Two bags of each medication were irradiated for different time intervals with 14.6 rad/min to achieve 0.1 Gy, 1 Gy and 10 Gy of cumulative radiation dose. Active pharmaceutical content (API) in each medication was determined and results analyzed. No significant difference in API content was observed between control and irradiated samples for both antibiotic tablets suggesting both types of bags may offer protection against gamma radiation; results with PMZ were inconclusive. These preliminary results suggest that Oliver-Tolas TPL-1475 and TPF-0599B materials may possess characteristics suitable for protection against ionizing radiation and can be considered for designing and further testing of FMD technology.

Du, Brian↗

Preliminary Evaluation of Commercial Off the Shelf (COTS) Packing Materials for Flight Medication Dispenser (FMD) Technology Development

This slide presentation reviews preliminary results of the program to evaluate Commercial Off the Shelf (COTS) packaging materials for pharmaceutical stability. The need for improved packaging is due to possible changes in chemical and/or physical properties of the drugs, which cause reported reduced potency and/or altered bioavailability and decreased efficacy.

Du, B.↗

Characterizing Methods of Measuring Flow-Mediated Dilation in the Brachial Artery

Regulation of vascular tone is one of the many important functions of the vascular endothelium. Endothelial dysfunction is a critical early event in the pathogenesis of atherosclerosis and occurs in the absence of angiographic disease. Flow-Mediated Dilation (FMD) is a noninvasive technique commonly used to evaluate endothelium-dependent vasodilation in humans and gauge the health of the cardiovascular system. Reductions in brachial artery FMD have been strongly correlated with disease progression and are predictive of future cardiac events. The flow stimulus for brachial artery FMD occurs as a result of the increased shear stress following deflation of an occlusion cuff around the upper arm. Using 2-dimensional ultrasound, changes in arterial diameter up to 5-minutes following cuff deflation are calculated from baseline image measurements. Along with pulsed Doppler measures of flow velocity through the artery, flow-mediated, endothelium-dependent vasodilation can be assessed. There is debate among investigators, however, about the proper positioning of the occlusion cuff during FMD testing. It is thought that placement of the cuff around the upper arm may not accurately reflect the impact of nitric oxide, a critically important molecule released as a result of the increased shear stress created by the FMD technique. Data suggest that the production of other endogenous metabolites may also contribute to FMD-related changes when positioning the cuff around the upper arm. To overcome the potential influence of such molecules, researchers now suggest that the occlusion cuff be placed below the elbow allowing a more precise estimate of nitric oxide mediated dilation. The purpose of this study is to compare the differences in FMD between the two methodologies of occlusion cuff placement. In addition, this study will determine the method that is easier for ultrasound technicians to perform and will produce a low coefficient of variance between technicians. Ultimately, the results of this study will help in tracking any adverse cardiovascular effects of spaceflight.

Callender, Ariane R.↗

Arterial Structure and Function in Women and Men Following Long Duration Bed Rest

Orthostatic intolerance is a well-recognized consequence of space flight and bed rest (BR), with a greater incidence reported in women. We hypothesized that leg, but not arm, arterial structure and function would be altered following prolonged BR, as a model of space flight, and that women would be more susceptible to BR-induced deconditioning than men. METHODS: Ten volunteers (5 males, 5 females) completed 90 d of 6 head-down BR. Subjects participated in tests of brachial (BA) and anterior tibial (AT) artery endothelium-dependent (flow mediated dilation [FMD] following 5-7 min of arterial occlusion) and endothelium-independent (0.4 mg sublingual nitroglycerin [SN]) vasodilation before BR (PRE) and on days 7 (BR7), 21 (BR21), and 90 (BR90) of BR. Vessel diameter and intimal medial thickness (IMT) were measured by ultrasound. IMT, baseline diameter, and percent change in diameter from baseline during FMD and SN tests were compared across BR and between genders using repeated measures two-way ANOVA with Bonferroni post-hoc tests in which PRE and women were control conditions. RESULTS: Baseline vessel diameter was lower in women than in men in both the BA (p=0.005) and AT (p=0.01) across all days. Baseline AT diameter decreased during BR (p=0.01) and tended to be more profound in women (interaction, p=0.06). AT diameter was reduced in women at BR21 and BR90 (p<0.01) but not in men. In contrast, there was no BR effect on baseline BA diameter. IMT also decreased in the AT (p<0.001) but not in the BA during BR; AT IMT was reduced by BR21 (p<0.05). As a group, there was no effect of BR on AT FMD, BA FMD, and AT SN-dilation, although BA SN-dilation was significantly reduced on BR21 (p=0.01). Across all BR days, women exhibited higher AT FMD (p=0.03), BA FMD (p=0.02), and BA SN-dilation (p=0.01) and tended to demonstrate greater AT SN-dilation (p=0.11). CONCLUSIONS: These preliminary results suggest that arterial remodeling occurs during BR in the leg (decreased diameter and IMT), but not in the arm, and that women appear to be more responsive to BR than men. These changes in the leg, coupled with larger responses to direct and indirect stimulation of the arterial smooth muscle, may be related to the greater incidence of orthostatic intolerance in women after BR and space flight.

Lee, Stuart M. C.↗

RRM3 Fluid Management Device

The current development progress of the fluid management device (FMD) for the Robotic Resupply Mission 3 (RRM3) cryogen source Dewar is described. RRM3 is an on-orbit cryogenic transfer experiment payload for the International Space Station. The fluid management device is a key component of the source Dewar to ensure the ullage bubble is located away from the outlet during transfer. The FMD also facilitates demonstration of radio frequency mass gauging within the source Dewar. The preliminary design of the RRM3 FMD is a number of concentric cones of Mylar which maximizes the volume of liquid in contact with the FMD in the source Dewar. This paper describes the design of the fluid management device and progress of hardware development

cryogenic fluids↗

Mars Sample Return: A Low Cost, Direct and Minimum Risk Design

Current NASA strategy for Mars exploration is seeking simpler, cheaper, and more reliable missions to Mars. This requirement has left virtually all previously proposed Mars Sample Return (MSR) missions as economically untenable. The MSR mission proposed in this paper represents an economical, back-to-basics approach of mission design by leveraging interplanetary trajectory design and limited surface science for shorter mission duration, advanced propulsion and thermal protection systems for mass reduction and simplified mission operations for high reliability. As a result, the proposed concept, called the Fast, Mini, Direct Mars Sample Return (FMD-MSR) mission represents the cheapest and fastest class of missions that could return a 0.5 kg sample from the surface of Mars to Earth with a total mission duration of less than 1.5 Earth years. The constraints require an aggressive mission design that dictates the use of advanced storable liquid propulsion systems and advanced TPS materials to minimize aeroshell mass. The mission does not have the high risk operations of other MSR missions such as orbit rendezvous at Mars, propulsive insertion at Mars, rover operations on the surface, and sample transfer. This paper details the key mission elements for such a mission and presents a feasible and cost effective design.

Wercinski, Paul F.↗

Flight Loads and Environments Initiative

A viewgraph presentation on the design of a lightweight non-intrusive force measurement device (FMD) to reduce the cost per effective payload (PL) mass into orbit (CPMO) by improving launch vehicle (LV) loads and environments.

Kaufman, Daniel↗

The Expression and Function of the Achaete-Scute Genes in Tribolium castaneum Reveals Conservation and Variation in Neural Pattern Formation and Cell Fate Specification

SUMMARY The study of achaete-scute (ac/sc) genes has recently become a paradigm to understand the evolution and development of the arthropod nervous system. We describe the identification and characterization of the ache genes in the coleopteran insect species Tribolium castaneum. We have identified two Tribolium ache genes - achaete-scute homolog (Tc-ASH) a proneural gene and asense (Tc-ase) a neural precursor gene that reside in a gene complex. Focusing on the embryonic central nervous system we fmd that Tc-ASH is expressed in all neural precursors and the proneural clusters from which they segregate. Through RNAi and misexpression studies we show that Tc-ASH is necessary for neural precursor formation in Triboliurn and sufficient for neural precursor formation in Drosophila. Comparison of the function of the Drosophila and Triboliurn proneural ac/sc genes suggests that in the Drosophila lineage these genes have maintained their ancestral function in neural precursor formation and have acquired a new role in the fate specification of individual neural precursors. Furthermore, we find that Tc-use is expressed in all neural precursors suggesting an important and conserved role for asense genes in insect nervous system development. Our analysis of the Triboliurn ache genes indicates significant plasticity in gene number, expression and function, and implicates these modifications in the evolution of arthropod neural development.

Wheeler, Scott R.↗

Improving Global Mass Flux Solutions from Gravity Recovery and Climate Experiment (GRACE) Through Forward Modeling and Continuous Time Correlation

We describe Earth's mass flux from April 2003 through November 2008 by deriving a time series of mas cons on a global 2deg x 2deg equal-area grid at 10 day intervals. We estimate the mass flux directly from K band range rate (KBRR) data provided by the Gravity Recovery and Climate Experiment (GRACE) mission. Using regularized least squares, we take into account the underlying process dynamics through continuous space and time-correlated constraints. In addition, we place the mascon approach in the context of other filtering techniques, showing its equivalence to anisotropic, nonsymmetric filtering, least squares collocation, and Kalman smoothing. We produce mascon time series from KBRR data that have and have not been corrected (forward modeled) for hydrological processes and fmd that the former produce superior results in oceanic areas by minimizing signal leakage from strong sources on land. By exploiting the structure of the spatiotemporal constraints, we are able to use a much more efficient (in storage and computation) inversion algorithm based upon the conjugate gradient method. This allows us to apply continuous rather than piecewise continuous time-correlated constraints, which we show via global maps and comparisons with ocean-bottom pressure gauges, to produce time series with reduced random variance and full systematic signal. Finally, we present a preferred global model, a hybrid whose oceanic portions are derived using forward modeling of hydrology but whose land portions are not, and thus represent a pure GRACE-derived signal.

Sabaka, T. J.↗

MAGIC: A Tool for Combining, Interpolating, and Processing Magnetograms

Transients in the solar coronal magnetic field are ultimately the source of space weather. Models which seek to track the evolution of the coronal field require magnetogram images to be used as boundary conditions. These magnetograms are obtained by numerous instruments with different cadences and resolutions. A tool is required which allows modelers to fmd all available data and use them to craft accurate and physically consistent boundary conditions for their models. We have developed a software tool, MAGIC (MAGnetogram Interpolation and Composition), to perform exactly this function. MAGIC can manage the acquisition of magneto gram data, cast it into a source-independent format, and then perform the necessary spatial and temporal interpolation to provide magnetic field values as requested onto model-defined grids. MAGIC has the ability to patch magneto grams from different sources together providing a more complete picture of the Sun's field than is possible from single magneto grams. In doing this, care must be taken so as not to introduce nonphysical current densities along the seam between magnetograms. We have designed a method which minimizes these spurious current densities. MAGIC also includes a number of post-processing tools which can provide additional information to models. For example, MAGIC includes an interface to the DA VE4VM tool which derives surface flow velocities from the time evolution of surface magnetic field. MAGIC has been developed as an application of the KAMELEON data formatting toolkit which has been developed by the CCMC.

Allred, Joel↗