Search NASA⌕ Search

SEARCH · Search NASA

Results for “FOCUSING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Focus enhancement in long schlieren imaging systems using corrector lenses

Long schlieren imaging systems, where the parallel light test section is longer than the focal length of the focusing schlieren optics, have a limited region in the test section in which any occluding object, such as a wind tunnel model, is in focus in the schlieren image. Corrector lenses are introduced here to alter the location in the test section where image focus is achieved. Corrector lenses with focal lengths varying from −1000 to −100mm were studied. Lens-type inline and z -type mirror schlieren systems were experimentally tested with multiple collecting optic focal lengths to characterize the changes in focal position. An automated image processing method was used to determine the plane of best focus from image sequences. The introduction of the corrector lens was observed to move the location of best focus within the schlieren system test section while also causing a decrease in the focal sharpness of the images and altering the magnification. The thin lens equation was found to provide a good estimate of the focal location change in the schlieren imaging systems with the addition of the corrector lens.

Torres, Sivana M.↗

The role of ambient gas confinement, plasma chemistry, and focusing conditions on emission features of femtosecond laser-produced plasmas

Ultrafast laser ablation coupled with optical emission spectroscopy is currently under development for standoff detection of elements and their isotopes for a wide range of application areas. In this work, we explore the role of ambient air pressure during the interaction of an ultrafast laser beam with two metallic targets (brass and uranium) with significantly different oxygen gas-phase reactivity. Plasma plumes were generated by focusing ~800 nm, ~35 fs pulses from an ultrafast laser system using a long focal length lens with f = 1 m. Two-dimensional spectral imaging was performed over the pressure range of 30 mTorr-700 Torr air to evaluate emission dynamics, plasma chemistry, signal-to-background ratio, and characteristic parameters (i.e. excitation temperature, electron density). An increase in ambient air pressure during ultrafast laser ablation leads to plume confinement and subsequent changes in the emission dynamics due to plasma chemistry as well as changes in plasma generation conditions (i.e. focused fs laser ablation versus filament ablation). Ablation crater morphologies were also investigated via scanning electron microscopy. Results indicate atomic emission intensity and signal-to-background ratios peak at moderate pressure levels (~50-100 Torr air) for both targets studied, although plasma chemistry influences uranium emission signatures. The emission features of the uranium plasma at pressures = 10 Torr showed the presence of atoms and oxide molecules which are co-located within the plume. We also find filament ablation leads to wider, more shallow craters compared to focused laser ablation. Our study provides unique insight into the interplay between plume dynamics, confinement, and oxygen chemistry of fs laser-produced plasmas and how these phenomena evolve with changing ambient air pressure.

Laser-produced plasma↗

A Kinetic Inductance Ammeter with Coplanar Waveguide Input Structure for Magnetic Flux Focusing

We propose a multiplexible kinetic inductance ammeter, which uses a high-quality-factor, superconducting, lumped-element, kinetic inductance resonator as a current sensor, a short, superconducting coplanar waveguide (CPW) for current input, and a CPW transmission line for the sensor readout. The resonator consists of an interdigitated capacitor and a superconducting loop that inductively couples to the input CPW. Current running through the central line of the input CPW generates magnetic fields which are focused into the gaps of the input CPW. These magnetic fields can be measured collectively as the magnetic flux through the superconducting loop. The kinetic inductance of the superconducting loop depends on the screening current for the magnetic flux, so the input current is converted to a change in the frequency of the resonator. We analyze the response and noise of a kinetic inductance ammeter with a high-resistivity NbN loop.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

DESI 2024: Constraints on physics-focused aspects of dark energy using DESI DR1 BAO data

Baryon acoustic oscillation data from the first year of the Dark Energy Spectroscopic Instrument (DESI) provide near percent-level precision of cosmic distances in seven bins over the redshift range z=0.1–4.2. Here, this paper is the follow-up to the original DESI BAO cosmology paper [A. G. Adame et al. (DESI Collaboration), arXiv:2404.03002], which considered the conventional w 0 w a cold dark matter (CDM) model. We use the novel DESI data, together with other cosmic probes, to constrain the background expansion history using some well-motivated physical classes of dark energy. In particular, we explore three physics-focused behaviors of dark energy from the equation of state and energy density perspectives: the thawing class (matching many simple quintessence potentials), emergent class (where dark energy comes into being recently, as in phase transition models), and mirage class [where phenomenologically the distance to cosmic microwave background (CMB) last scattering is close to that from a cosmological constant Λ despite dark energy dynamics]. All three classes fit the data at least as well as Λ ⁢CDM, and indeed can improve on it by Δ⁢χ 2 ≈ –5 to –17 for the combination of DESI BAO with CMB and supernova data while having one more parameter. The mirage class does essentially as well as w 0 ⁢w a CDM and exhibits moderate to strong Bayesian evidence preference with respect to Λ⁢ CDM. These classes of dynamical behaviors highlight worthwhile avenues for further exploration into the nature of dark energy.

79 ASTRONOMY AND ASTROPHYSICS↗

A bioenergy-focused versus a reforestation-focused mitigation pathway yields disparate carbon storage and climate responses

Limiting global warming to 2 °C requires urgent action on land-based mitigation. This study evaluates the biogeochemical and biogeophysical implications of two alternative land-based mitigation scenarios that aim to achieve the same radiative forcing. One scenario is primarily driven by bioenergy expansion (SSP226Lu-BIOCROP), while the other involves re/afforestation (SSP126Lu-REFOREST). We find that overall, SSP126Lu-REFOREST is a more efficient strategy for removing CO2 from the atmosphere by 2100, resulting in a net carbon sink of 242 ~ 483 PgC with smaller uncertainties compared to SSP226Lu-BIOCROP, which exhibits a wider range of -78 ~ 621 PgC. However, SSP126Lu-REFOREST leads to a relatively warmer planetary climate than SSP226Lu-BIOCROP, and this relative warming can be intensified in certain re/afforested regions where local climates are not favorable for tree growth. Despite the cooling effect on a global scale, SSP226Lu-BIOCROP reshuffles regional warming hotspots, amplifying summer temperatures in vulnerable tropical regions such as Central Africa and Southeast Asia. Our findings highlight the need for strategic land use planning to identify suitable regions for re/afforestation and bioenergy expansion, thereby improving the likelihood of achieving the intended climate mitigation outcomes.

54 ENVIRONMENTAL SCIENCES↗

AXAF SIM focus mechanism study

The design requirements and initial design concept for the AXAF-I Science Instrument Module (SIM) were reviewed at Ball on September 29, 1993. The concept design SIM focus mechanism utilizes a planetary gearset, with redundant motors, to drive a large ring (called 'main housing bearing') via a spur gearset. This large drive ring actuates three tangent bar links (called 'push rods'), which in turn actuate three levers (called 'pin levers'). Each of the three pin levers rotates an 'eccentric pin,' which in turn moves the base of a bipod flexure in both the radial (normal to optical axis) and axial (focus along optical axis) directions. Three bipod flexures are employed, equally spaced at 120 degrees apart, the base of each being translated in the two directions as described above. A focus adjustment is made by rotating the drive ring, which drives the push rods and therefore the pin levers, which in turn rotate the eccentric pins, finally imparting the two motions to the base of each of the bipod flexures. The axial translation (focus adjustment) of the focused structure is the sum of the direct axial motion plus axial motion which comes from uniformly squeezing the three bipod bases radially inward. SAO documented the following concerns regarding the focus mechanism in memo WAP-FY94-001, dated October 7, 1993: (1) The focus adjustment depends, in large part, on the structural properties (stiffnesses and end fixities) of the bipod flexures, push rods, pin levers and eccentric pins. If these properties are not matched very well, then lateral translations as well as unwanted rotations of the focussed structure will accompany focus motion. In addition, the stackup of linkage tolerances and any nonuniform wear in the linkages will result in the same unwanted motions. Thermal gradients will also affect these motions. At the review Ball did not present supporting analyses to support their choice of this design concept. (2) The proposed 'primary' method of measuring focus is by counting motor steps. The 'backup' method is by a pot mounted on the drive ring. Neither method provides for a direct measurement of the quantity desired (focus position). This is of concern because of the long and indirect relationship between focus and the sensed quantity (drive ring rotation). There are three sinusoidal relationships and structural stiffness in the path, and the resulting calibration is likely to be highly nonlinear. These methods would require an accurate ground calibration. (3) Ground calibration (and verification) of focus vs. drive position must be done in 1-g on the ground. This calibration will be complicated by both the structural characteristics of the bipods and the fact that the CG of the translating portion of the SIM is not on the optical axis (thereby causing unwated rotations and changing the focus position vs. motor step and pot readout relationships). The SIM translating weight could be offloaded, but the calibration then becomes sensitive to any errors in offloading (both magnitude and direction). There are concerns as to whether a calibration to the required accuracy can be accomplished on the ground. (4) The choice of a potentiometer as the focus position sensor is questionable in terms of reliability for a five year mission. The results of SAO's study of items 1, 2 and 3 described above are presented in this report.

Tananbaum, H. D.↗

In-Situ Focusing Inside a Thermal Vacuum Chamber

Traditionally, infrared (IR) space instruments have been focused by iterating with a number of different thickness shim rings in a thermal vacuum chamber until the focus meets requirements. This has required a number of thermal cycles that are very expensive as they tie up many integration and test (I&T)/ environmental technicians/engi neers work ing three shifts for weeks. Rather than creating a test shim for each iteration, this innovation replaces the test shim and can focus the instrument while in the thermal vacuum chamber. The focus tool consists of three small, piezo-actuated motors that drive two sets of mechanical interface flanges between the instrument optics and the focal- plane assembly, and three optical-displacement metrology sensors that can be read from outside the thermal vacuum chamber. The motors are used to drive the focal planes to different focal distances and acquire images, from which it is possible to determine the best focus. At the best focus position, the three optical displacement metrology sensors are used to determine the shim thickness needed. After the instrument leaves the thermal vacuum chamber, the focus tool is replaced with the precision-ground shim ring. The focus tool consists of two sets of collars, one that mounts to the backside of the interface flange of the instrument optics, and one that mounts to the backside of the interface flange of the focal plane modules. The collars on the instrument optics side have the three small piezo-actuated motors and the three optical displacement metrology systems. Before the instrument is focused, there is no shim ring in place and, therefore, no fasteners holding the focal plane modules to the cameras. Two focus tooling collars are held together by three strong springs. The Orbiting Carbon Observatory (OCO) mission spectrometer was focused this way (see figure). The motor described here had to be moved five times to reach an acceptable focus, all during the same thermal cycle, which was verified using pupil slicing techniques. A focus accuracy of .20.100 microns was achieved.

Liebe, Carl Christian↗

Fuzzy control system for a remote focusing microscope

Space Station Crew Health Care System procedures require the use of an on-board microscope whose slide images will be transmitted for analysis by ground-based microbiologists. Focusing of microscope slides is low on the list of crew priorities, so NASA is investigating the option of telerobotic focusing controlled by the microbiologist on the ground, using continuous video feedback. However, even at Space Station distances, the transmission time lag may disrupt the focusing process, severely limiting the number of slides that can be analyzed within a given bandwidth allocation. Substantial time could be saved if on-board automation could pre-focus each slide before transmission. The authors demonstrate the feasibility of on-board automatic focusing using a fuzzy logic ruled-based system to bring the slide image into focus. The original prototype system was produced in under two months and at low cost. Slide images are captured by a video camera, then digitized by gray-scale value. A software function calculates an index of 'sharpness' based on gray-scale contrasts. The fuzzy logic rule-based system uses feedback to set the microscope's focusing control in an attempt to maximize sharpness. The systems as currently implemented performs satisfactorily in focusing a variety of slide types at magnification levels ranging from 10 to 1000x. Although feasibility has been demonstrated, the system's performance and usability could be improved substantially in four ways: by upgrading the quality and resolution of the video imaging system (including the use of full color); by empirically defining and calibrating the index of image sharpness; by letting the overall focusing strategy vary depending on user-specified parameters; and by fine-tuning the fuzzy rules, set definitions, and procedures used.

Weiss, Jonathan J.↗

Focus history of the Hubble Space Telescope: Launch to May 1993

Since the launch of the Hubble Space Telescope (HST) the secondary mirror of the telescope has been moved several times in order to collimate the telescope and also to define a position of best focus. In addition to these moves the focus position changes over time because of water desorption by the graphite epoxy in the metering truss. The authors report here the focus history of the telescope based on a knowledge of the mirror moves made and an analysis of desorption monitoring data obtained by the Faint Object Camera (FOC) in the F/96 mode and of the routine calibration data obtained by the Wide Field and Planetary Cameras. Focus values are extracted using two different methods. In the first method the distance between the center of the point spread function (PSF) and the shadows of the pads supporting the HST primary mirror are related to the focus error. In the second method an analytical formula for the PSF with variable aberration coefficients is fitted to the data. Focus positions derived from the two methods show good agreement. The data show that a desorption of about 83 microns has taken place since Aug. 16, 1990. The desorption has clearly not leveled off as expected from the trend of the earlier data. Long term variations of the secondary mirror position of approximately 3-15 microns from the 'best' focus position have been observed. Variations of the order of 2-5 microns over an orbital period have also been noted. Focus changes resulting from secondary mirror movements greater than approximately 5 microns changes the point spread function significantly and makes deconvolution and quantitative measurements difficult.

Hasan, H.↗

Flying focus: Spatial and temporal control of intensity for laser-based applications

An advanced focusing scheme, called a "flying focus," uses a chromatic focusing system combined with a broadband laser pulse with its colors arranged in time to propagate a high intensity focus over a distance that can be much greater than its Rayleigh length, while decoupling the speed at which the peak intensity propagates from its group velocity. The flying focus generates a short effective pulse duration with a small diameter focal spot that co- or counter-propagates along the optical axis at any velocity. Experiments validating the concept measured subluminal (–0.09c) to superluminal (39c) focal spot velocities with a nearly constant peak intensity over 4.5 mm. Experiments that increased the peak intensity above the ionization threshold for gas demonstrated ionization waves propagating at the velocity of the flying focus. Here these ionization waves of any velocity overcome several laser-plasma propagation issues, including ionization-induced refraction. The flying focus presents opportunities to overcome current fundamental limitations in laser-plasma amplifilers, laser wakefield accelerators, photon accelerators, and high-order frequency conversion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗