Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREEZERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Life sciences passive GN2 freezer thermal performance test

Thermal performance tests that were conducted on the life sciences passive GN2 freezer project are summarized as well as the improvements to the freezers to improve the thermal performance of the containers. Procedures were developed, based upon these tests, to initially charge the freezers with LN2 and verify that the freezer performance is adequate for the mission duration. Improvements were made to the corvac sample tube to limit the amount of breakage due to thermal expansion of the liquid during freezing. A method of verifying the freezer vacuum insulative integrity was defined as well as a procedure for refurbishment of the internal vacuum level. Freezer modifications were made to ease the reevacuation of the containers. The orientation of the freezer in a 1-G environment, after being charged, had to remain in a vertical position. The LN2 boiloff rate increased significantly in a horizontal position. This resulted in a stowage definition in the spacecraft prior to launch. Functional testing, using the SL-1 mission timeline showed that the freezer will maintain samples in the frozen state for the duration of the mission.

Belshaw, G. W.↗

Final Scientific/Technical Report-FREE-piston Zero Emissions Refrigerator (FREEZER)

The FREE-piston Zero Emissions Refrigerator (FREEZER™) is a natural refrigerant Stirling-cycle cooler developed by AMSC in partnership with Heatcraft, targeted as a replacement refrigeration system for walk-in coolers or freezers found commonly in restaurants, convenience stores, supermarkets, etc. The FREEZER™, combined with a closed-loop CO2 heat-transfer system, had the goal to provides an efficient (Target COP = 1.4), zero ODP (Ozone Depletion Potential) and near zero GWP (Global Warming Potential) refrigeration solution with no synthetic, flammable, or toxic refrigerants. Other near zero GWP refrigeration systems do not exist at the scale and performance level of FREEZER. ARPA-E Continuation Funding enabled the design and fabrication of one Advanced Development Unit (ADU) cooler and two Field Test Unit (FTU) coolers, and a new revised Field Test Unit (new FTU). Heatcraft was to extensively test the various coolers at their facilities, which closely simulate real-world conditions. The original plan was to install and operate FREEZER FTUs alongside a traditional cooling solution at one or more customer locations to obtain data on direct performance comparisons with existing commercial refrigeration systems. Success in this FREEZER refinement and field-test project will establish the basis for a new class of environmentally friendly refrigeration systems that will revolutionize the industry. The hardware developed under the program is shown below in Figure 1. Five Stirling-cycle machines were built within the program, with a sixth cooler still under construction. The original DU and the ADU coolers met the performance target with a coefficient of performance (COP) of 1.2. The FTU was underperforming during the initial tuning of the free-piston Stirling cycle dynamics when there was a catastrophic failure of the fasteners on pressure boundary. This caused a pause to the program while the failure mechanism was investigated. The root cause was an inadequate flange design that allowed an excessive cyclic loading on the fasteners, leading to a fatigue failure. It was determined that existing FTU design could not be reasonably salvaged in a safe manner, and that fact, combined with the lower-than-expected performance of the new experimental heat exchanger modules lead to the design of the “new FTU” with a more conventional shell-and-tube heat exchanger design which should get close to the design target COP of 1.4, but have a higher overall machine cost. The program ran out of time before the fabrication of the new FTU was completed, but AMSC is still working on the cooler, with the majority of the parts fabricated, and hopes to have the unit under test sometime in early 2022, after which it will be shipped to Heatcraft for additional testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Investigation on Cooling performance of A Thermoelectric Freezer

Thermoelectric heat pumps (TEHPs) have found widespread use in the electronics cooling industry and portable refrigerators. However, there has been a lack of extensive research on the application of TEHPs in low-temperature refrigeration settings. To address this gap, various configurations of TEHPs were fabricated to assess their suitability for freezer applications. Key parameters such as cooling capacity and system performance of the TEHPs were crucial in evaluating these configurations. Three configurations, each with different numbers of cooling units and fan arrangements, were tested using a 300-liter freezer prototype under typical room conditions (21°C). A cooling unit is comprised of two-stage thermoelectric modules, an aluminum plate fin heat exchanger sink with fans positioned either on top or directing airflow through the center, and a cooling block with circulating icy water for heat dissipation. Across all configurations, the minimum temperature inside the freezer cabinet reached -16.0°C. The cooling capacity peaked at 74.7 W, with the thermoelectric coefficient of performance (COP) reaching a maximum of 0.45. System COP ranged from 0.23 to 0.28. Minimum TE power consumption was recorded at 138.8 W, with TE system power consumption at 174.4 W, indicating feasibility for practical residential freezer applications. This investigation lays the foundation for integrating TE freezers with ice thermal storage systems.

Hu, Yifeng↗

Shuttle Kit Freezer Refrigeration Unit Conceptual Design

The refrigerated food/medical sample storage compartment as a kit to the space shuttle orbiter is examined. To maintain the -10 F in the freezer kit, an active refrigeration unit is required, and an air cooled Stirling Cycle refrigerator was selected. The freezer kit contains two subsystems, the refrigeration unit, and the storage volume. The freezer must provide two basic capabilities in one unit. One requirement is to store 215 lbs of food which is consumed in a 30-day period by 7 people. The other requirement is to store 128.3 lbs of medical samples consisting of both urine and feces. The unit can be mounted on the lower deck of the shuttle cabin, and will occupy four standard payload module compartments on the forward bulkhead. The freezer contains four storage compartments.

Copeland, R. J.↗

Shuttle freezer conceptual design

A conceptual design for a kit freezer for operation onboard shuttle was developed. The freezer features a self-contained unit which can be mounted in the orbiter crew compartment and is capable of storing food at launch and returning with medical samples. Packaging schemes were investigated to provide the optimum storage capacity with a minimum weight and volume penalty. Several types of refrigeration systems were evaluated to select one which would offer the most efficient performance and lowest hazard of safety to the crew. Detailed performance data on the selected, Stirling cycle principled refrigeration unit were developed to validate the feasibility of its application to this freezer. Thermal analyses were performed to determine the adequacy of the thermal insulation to maintain the desired storage temperature with the design cooling capacity. Stress analyses were made to insure the design structure integrity could be maintained over the shuttle flight regime. A proposed prototype freezer development plan is presented.

Proctor, B. W.↗

Improving the energy efficiency of a refrigerator-freezer through the use of a novel cabinet/door liner based on polylactide biopolymer

This paper presents the energy savings potential of a newly developed liner applied on the foam insulation used in refrigerator and freezer cabinets, compared with using a more commonly used liner made from high-impact polystyrene. The new polylactic acid polymer liner is made from renewable feedstock such as carbon found in plant sugars. The energy use over the life of refrigerator and freezer is calculated using the Energy-Efficient Refrigerator Analysis program developed by the United States Department of Energy to estimate the energy savings potential of various technology option upgrades (cabinet and refrigeration system) for rulemaking purposes. The simulation results show that energy savings from implementing the Ingeo liner range from 818 to 1395tkWh (7.3–12.5% of total energy use) over a 15-year period. In addition to the energy savings, the slower increase in the thermal conductivity of the insulation could allow the compressor to run fewer hours per year compared with a case in which the foam thermal conductivity increases rapidly. This change could increase the life of the compressor and the refrigerators and freezers. As a result, this study does not attempt to quantify the impact of slower foam aging on the compressor life.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Market Assessment for Residential Refrigerator-Freezer with Novel Rotating Heat Exchanger

Despite a steady record of energy efficiency improvements in residential refrigerators and freezers over recent decades, these products still account for 4% of the site energy consumption for the average U.S. household. The Oak Ridge National Laboratory (ORNL) – along with partners Sandia National Laboratories (SNL) and the University of Maryland – are pursuing further efficiency improvements in this market sector by using a novel/prototype rotating heat exchanger (RHX) based on a Sandia Cooler technology as an evaporator in a residential refrigerator-freezer. The purpose of this study is to investigate the market potential of refrigerator-freezer products equipped with RHX evaporators in the United States, including projections of maximum annual market share and unit shipments and maximum direct and indirect job creation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analysis of Seed Sanitization, Rapid Freezer Proficiency, and Veg-03 Water Verification

In order to ensure the well-being of astronauts and experiments on the ISS (International Space Station), seeds need to be free of microbes, the rapid freezer needs to be freezing biological samples evenly and proficiently, and the astronauts need to have accurate watering procedures for Veg-03 (the latest Phytotron for the Veggie (Vegetable Production System) project). Seed flight candidates were sanitized with varying levels of HCL in order to determine the right amount to use for future flight experiments, too much HCL and the seeds will not germinate and too little and they will be contaminated with microorganisms. The rapid freezer was assessed using temperature probes to determine if there is a homogeneous change in temperature in order to ensure the safe freezing of biological organisms. The plant watering procedures given to the astronauts were assessed in order to make sure that Veg-03 experiments are receiving the correct amount of water.

Hollingsworth, Savannah↗

Improved Performance of Polyurethane Foam Insulation Using Ingeo Biopolymer Liners and its Impact on Energy Efficiency of Refrigerator and Freezers

This paper compares the effect of isothermal aging of the thermal conductivity of polyurethane foam in simulated refrigerator-freezer panels made from polylactic acid biopolymer from NatureWorks (IngeoTM) and high-impact polystyrene. Specimens were aged at room temperature and thermal conductivity measurements were made at 10°C over a period of 2.4 years. The energy use over the life of refrigerator-freezer is also calculated using the Energy-Efficient Refrigerator Analysis program which was developed by the United States Department of Energy to estimate the energy savings potential of various technology option upgrades (cabinet and refrigeration system) for rulemaking purposes. The results show that energy savings from implementing the Ingeo liner range from 818 to 1395 kWh (7 to 13% of total energy use) over a 15-year period.

Hossieny, Nemat↗

Ultra-Low-Temperature Laboratory Freezer Specification

This specification provides a description of required performance characteristics resulting in increased energy savings for ultra-low-temperature freezers (ULTs) in laboratories.

Refrigeration, ultra-low-temperature laboratory fr↗

Shuttle Spacelab Core Equipment Freezer

This paper describes the preliminary design of a Shuttle Spacelab Core Equipment Freezer. The unit will provide the capability to freeze and store many experiment specimens. Two models of the unit are planned. One model provides storage at -70 C; the other model will provide -70 C storage, a freeze dry capability, storage at a selectable temperature in the range of 0 C to -70 C, and means of maintaining close temperature tolerances. In addition an exchanger loop will be available at 4 C for cooling of a centrifuge and a remote storage compartment. A test tube holder, a dish holder and thermal capacitors for rapid freezing of large specimens will also be provided. A Stirling Cycle was selected as the active refrigerator for minimum cost and weight.

Copeland, R. J.↗

Food and medical sample freezer kit concept for Shuttle

A variety of food and storage of samples can be provided by a Space Shuttle Orbiter Freezer Kit. The proposed concept is an integrated package consisting of four -23 C (-10 F) storage compartments and a Stirling cycle refrigeration unit. The Stirling cycle mechanical refrigeration was selected over alternative systems for superior efficiency and safety. The trade-offs and a conceptual design of the system are presented.

Copeland, R. J.↗

Development of the Space Station Freedom Refrigerator/Freezer and Freezer

This paper presents the current design configuration of the Space Station Freedom (SSF) Refrigerator/Freezer and Freezer (R/F and F) systems. In addition, this paper establishes the current analyses/trade study activity related to refrigeration system design and defines Environmental Control and Life Support System (ECLSS) interfaces, anticipated heat loads, maintenance approaches and safety concerns.

Zelon, Jon↗

Recertification and Equivalency Test Results for IM7/8552-1 Following Extended Freezer Storage

In 2015, the Composites for Exploration Upper Stage (CEUS) Project established an equivalency test program to reduce the scope of laminate coupon tests within the project. The material selected was IM7/8552-1, a variant of the IM7/8552 prepreg used to populate a National Center for Advanced Materials Performance (NCAMP) database. The CEUS successor program, Composites Technology for Exploration (CTE), kicked off in 2017 with the remaining CEUS prepreg planned for use. The IM7/8552-1 prepreg was recertified through an in-house defined set of pass/fail criteria then evaluated for equivalency to the NCAMP database. Over the course of recertification and equivalency panel fabrication, the time of freezer storage ranged from 19 - 22 months. Panels for recertification and equivalency tests were fiber placed at NASA Marshall Space Flight Center (MSFC) and NASA Langley Research Center (LARC).

carbon fiber/epoxy↗

Re-Certification and Equivalency Test Results for IM7/8552-1 Following Extended Freezer Storage

In 2015, the Composites for Exploration Upper Stage (CEUS) Project established an equivalency test program to reduce the scope of laminate coupon tests within the project. The material selected was IM7/8552-1, a variant of the IM7/8552 prepreg used to populate a National Center for Advanced Materials Performance (NCAMP) database. The CEUS successor program, Composites Technology for Exploration (CTE), kicked off in 2017 with the remaining CEUS prepreg planned for use. The IM7/8552-1 prepreg was recertified through an in-house defined set of pass/fail criteria then evaluated for equivalency to the NCAMP database. Over the course of recertification and equivalency panel fabrication, the time of freezer storage ranged from 19-23 months. Panels for recertification and equivalency tests were fiber placed at NASA Marshall Space Flight Center (MSFC) and NASA Langley Research Center (LARC).

equivalency↗

Note: A microfluidic freezer based on evaporative cooling of atomized aqueous microdroplets

We report for the first time water-based evaporative cooling integrated into a microfluidic chip for temperature control and freezing of biological solution. We opt for water as a nontoxic, effective refrigerant. Aqueous solutions are atomized in our device and evaporation of microdroplets under vacuum removes heat effectively. We achieve rapid cooling (−5.1 °C/s) and a low freezing temperature (−14.1 °C). Using this approach, we demonstrate freezing of deionized water and protein solution. Our simple, yet effective cooling device may improve many microfluidic applications currently relying on external power-hungry instruments for cooling and freezing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗