Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

On the use of freon-12 for increasing Reynolds number in wind-tunnel testing of three dimensional aircraft models at subcritical and supercritical Mach numbers

The aerodynamic suitability of Freon-12 for general wind-tunnel testing was investigated at low and high subsonic speeds. Static aerodynamic characteristics of two transport airplane models were determined from strain gage balance measurements in both air and Freon-12 at several Reynolds numbers. A low-speed high-lift configuration was evaluated at Mach number 0.25, and a high-speed cruise wing-fuselage combination was tested at Mach numbers up to 0.825. The data obtained in air and in Freon-12 agree well, even in stalled flow, until compressibility effects evidently become significant in air and in Freon-12 agree well, even in stalled flow, until compressibility effects evidently become significant in air.

Treon, S. L.↗

Development of a Centrifugal Technique for the Microbial Bioburden Analysis of Freon (CFC-11)

NASA Procedural Requirement 8020.12C entitled "Planetary Protection Provisions for Robotic Extraterrestrial Missions" states that the source-specific encapsulated microbial density for encapsulated organisms (div(0)) in nonmetallic materials ranges from 1-30 spores/cubic cm. The standard laboratory procedure, NASA Standard Procedures for the Microbial Examination of Space Hardware, NHB 5340.1B, does not provide any direction into the methodologies to understand the bioburden within such a fluid as CFC-11 (Freon). This general specification value for the Freon would be applicable to the Freon charged within the Mars Science Laboratory fs (MSL fs) Heat Rejection System. Due to the large volume required to fill this system, MSL could not afford to conservatively allocate 55.8% of the total spore budget of the entire laboratory system (rover, descent stage, cruise stage, and aeroshell) of 5.00 X 10(exp 5) spores at launch. A novel filtration approach was developed to analyze the Freon employing a 50 kDa molecular weight cutoff (MCO) filter, followed by 0.22-micron pore-size filter to establish a calculated microbial bioburden.

Benardini, James N.↗

Independent Review of Paducah Gaseous Diffusion Plant Freon Release Authorized Limits and Evaluation of Corresponding Radiological Doses

The Portsmouth/Paducah Project Office (PPPO) proposes to use the American National Standard Institute (ANSI)/Health Physics Society (HPS) N13.12 (ANSI 2013) volumetric screening levels as Authorized Limits (ALs) for the release of cryofluorane R-114 (Freon) at the Paducah Gaseous Diffusion Plant (PGDP) in Paducah, Kentucky. A review of the proposed ALs document indicated that potential exposure scenarios from the release of Freon are adequately discussed therein. However, questions arose regarding the assumptions made for the ANSI N13.12 clearance values, and whether or not all pathway doses were adequately considered in the Authorized Limits Request. For example, PPPO used the inverse square rule to estimate dose to the truck driver. A more appropriate evaluation would have considered the material as a cylindrical source for this pathway. In addition, the inverse square rule was inadequately applied to the inhalation and ingestion pathways. Furthermore, while the ANSI N13.12 volumetric clearance values are used in the ALs, questions arose concerning whether the values are appropriate for materials of greater than 1 metric ton, and whether or not the ANSI N13.12 standard could be used for liquids that are sent to an incinerator. For these reasons, dose modeling was conducted to demonstrate that using ANSI/HPS N13.12 screening levels as ALs for release of PGDP Freon meets the dose criteria set in U.S. Department of Energy (DOE) Order 458.1. This report provides a bounding dose analysis using scenarios described in PPPO document. Realistic parameters, such as the incinerator characteristics data, are used when available.

61 RADIATION PROTECTION AND DOSIMETRY↗

Freon 21 bearing lubrication and coolant system

Lubrication and cooling of turbopump rotor bearings by liquid Freon 21 is reported. Freon expands in rotor bearing and acts as heat sink by removing heat during warming and evaporation. Gaseous Freon is removed by vacuum pump controlling rotor chamber operation.

Bodensieck, E. J.↗

Freon consumption - Implications for atmospheric ozone

Freons are a potential source of stratospheric chlorine and may indirectly cause serious reductions in the concentration of ozone. The reduction could be as large as 3 percent by 1980, or 16 percent by 2000, if Freon consumption were to grow at 10 percent per year. Even if Freon use were terminated as early as 1990, it could leave a significant effect which might endure for several hundred years.

Wofsy, S. C.↗

Correlation of full-scale helicopter rotor performance in air with model-scale Freon data

An investigation was conducted in a transonic dynamics tunnel to measure the performance of a 1/5 scale model helicopter rotor in a Freon atmosphere. Comparisons were made between these data and full scale data obtained in air. Both the model and full scale tests were conducted at advance ratios between 0.30 and 0.40 and advancing tip Mach numbers between 0.79 and 0.95. Results show that correlation of model scale rotor performance data obtained in Freon with full scale rotor performance data in air is good with regard to data trends. Mach number effects were found to be essentially the same for the model rotor performance data obtained in Freon and the full scale rotor performance data obtained in air. It was determined that Reynolds number effects may be of the same magnitude or smaller than rotor solidity effects or blade elastic modeling in rotor aerodynamic performance testing.

Yeager, W. T., Jr.↗

Comparison of aerodynamic data measured in air and Freon-12 wind-tunnel test mediums

An experimental investigation was carried out to measure two dimensional static aerodynamic characteristics of a 65 sub l-213 airfoil in air and Freon-12 (dichlorodifluoromethane) test mediums at corresponding test conditions. The purpose of the tests was to compare measurements in the two test mediums and to evaluate reported methods of converting Freon-12 data to equivalent air values. The test article was a two dimensional wing instrumented to measure chordwise surface pressure distributions. The parameters considered were Mach numbers from 0.6 to 1.0, angles of attack of zero deg and 1 deg, and Reynolds numbers based on model chord from 2,000,000 to 21,000,000. The agreement between data measured in the two test mediums is further improved by application of the transonic or area ratio similarity laws. Where flow conditions are characterized by surface shocks or stall, the effects of flow separation may not be identically reflected in the Freon-12 data, even when converted in accordance with existing similarity laws.

Weller, W. H.↗

Freon provides heat transfer for solid C02 calibration standard

Acetone and Freon as liquid heat transfer mediums bring a dry ice bath to, and keep it at, the temperature required when using solid carbon dioxide as a calibration standard. Although acetone gives better results, Freon TF is preferred since acetone reacts violently in the presence of liquid oxygen.

Source record↗

Effects of inhalation of Freon 113 on laboratory animals

Four monkeys, 8 dogs, 40 mice, and 50 rats were exposed continuously to 2000 ppm Freon 113 in a Thomas Dome for 14 days. This exposure produced no mortalities nor adverse symptomology. There were no significant alterations in hematological values, clinical chemistries, electroencephalographic findings, body weights, or organ to body weight ratios. The effect of 2% Freon 113 on nicotinic transmission through the stellate ganglion of the spinal dog was also evaluated. The exposure induced a reduction in nicotinic transmission comparable to 2% halothane.

Carter, V. L.↗

Input guide for computer programs to generate thermodynamic data for air and Freon CF4

FORTRAN computer programs were developed to calculate the thermodynamic properties of Freon 14 and air for isentropic expansion from given plenum conditions. Thermodynamic properties for air are calculated with equations derived from the Beattie-Bridgeman nonstandard equation of state and, for Freon 14, with equations derived from the Redlich-Quang nonstandard equation of state. These two gases are used in scale model testing of model rocket nozzle flow fields which requires simulation of the prototype plume shape with a cold flow test approach. Utility of the computer programs for use in analytical prediction of flow fields is enhanced by arranging card or tape output of the data in a format compatible with a method-of-characteristics computer program.

Tevepaugh, J. A.↗

Entry heat transfer tests of the 0.006-scale space shuttle orbiter model (50-0) in Langley Research Center freon tunnel at Mach 6 (OH45)

Results are presented of heat transfer tests of a 147B configuration orbiter model (50-0) conducted in the NASA Langley Research Center Freon Tunnel (LRC/CF4). These tests were conducted at a nominal Mach number of 6, and at Reynolds numbers of 0.3 and 0.5 x 1,000,000 per foot. The objectives of the tests were to determine the effects of the low freon specific heat ratio, gamma, on the heating distributions and to determine the impingement of the orbiter bow shock on the wing. The data presented include thin skin heat transfer data (tabulated data and plotted data).

Foust, J. W.↗

High resolution absorption coefficients for Freon-12

The ultra high resolution absorption coefficients of the Q-branch of Freon-12 obtained with tunable diode laser spectroscopy are presented. Continuous spectra are presented from 1155/cm to 1163/cm, and absolute wavelength calibration was obtained using SO2 spectra as a standard and a 5 cm Ge etalon for relative calibration between SO2 lines. The Freon-12 data obtained at a pressure of 0.05 torr showed a rich and highly structured spectra, but with the exception of three isolated features, collisional broadening reduces the spectra to a structureless continuum for nitrogen pressures greater than 20 torr. The spectra at 1161/cm continue to exhibit structure at atmospheric pressure.

Hoell, J. M.↗

Stress-corrosion crack-growth study of titanium alloy Ti-6Al-4V exposed to freon PCA and nitrogen tetroxide MON-1

An experimental fracture mechanics program was performed to determine the stress corrosion crack growth sensitivity of the propellant tank material, titanium alloy Ti-6Al-4V, for aerospace satellite applications involving long term exposure to Freon PCA and nitrogen tetroxide MON-1. Sustained load tests were made at a 49 C (120 F) constant temperature using thin gauge tensile test specimens containing semielliptical surface flaws. Test specimen types included parent metal, center of weld, and weld heat affected zone. It was concluded that Ti-6Al-4V alloy is not adversely affected in a stress environment when exposed to Freon PCA for 1000 hours followed by exposure to nitrogen tetroxide MON-1 for 2000 hours at stress levels up to 80% of the experimental critical plane strain stress intensity factor.

Bjorklund, R. A.↗

The Freon loop double containment design for Spacelab refrigerator/freezer to protect environment

General Electric is building a vapor compression refrigerator/freezer for NASA-Johnson Space Center for the Spacelab mission SLS-1 for life sciences experiments. Freon R502 is used as refrigerant. As R502 is considered toxic, the whole Freon loop is enclosed in a second containment to avoid exposure to crewmen. A detailed description of the design and construction of the safety enclosure is presented.

Hye, A.↗

A Mach 6 external nozzle experiment with Argon-Freon exhaust simulation

A scramjet exhaust simulation technique for hypersonic wind tunnel testing has been developed. Mixtures of Argon and Freon correctly match the inviscid simulation parameters of Mach number, static-pressure ratio, and the ratio of specific heats at the combustor exit location; this simulation is accomplished at significantly reduced temperatures and without combustion. An investigation of nozzle parametrics in a Mach 6 freestream showed that the external nozzle ramp angle, the cowl trailing-edge angle, an external nozzle flow fence and the nozzle static-pressure ratio significantly affected the external nozzle thrust and pitching moment as measured by the integration of surface-pressure data. A comparison of Argon-Freon and air exhaust simulation showed that the external nozzle thrust and pitching moment were in error by roughly a factor of 2 using air due to the incorrect match of the ratio of specific heats. An assessment of two-dimensional Euler and Navier-Stokes codes for predicting external nozzle aerodynamic characteristics was made by comparing computed and experimental results.

Pittman, James L.↗

A parametric experimental investigation of a scramjet nozzle at Mach 6 with Freon and argon or air used for exhaust simulation

A parametric experimental investigation of a scramjet nozzle was conducted with a gas mixture used to simulate the scramjet engine exhaust flow at a free-stream Reynolds number of approximately 6.5 x 10(exp 6) per foot. External nozzle surface angles of 16, 20, and 24 deg were tested with a fixed-length ramp and for cowl internal surface angles of 6 and 12 deg. Pressure data on the external nozzle surface were obtained for mixtures of Freon and argon gases with a ratio of specific heats of about 1.23, which matches that of a scramjet exhaust. Forces and moments were determined by integration of the pressure data. Two nozzle configurations were also tested with air used to simulate the exhaust flow. On the external nozzle surface, lift and thrust forces for air exhaust simulation were approximately half of those for Freon-argon exhaust simulation and the pitching moment was approximately a third. These differences were primarily due to the difference in the ratios of specific heats between the two exhaust simulation gases. A 20 deg external surface angle produced the greatest thrust for a 6 deg cowl internal surface angle. A flow fence significantly increased lift and thrust forces over those for the nozzle without a flow fence.

Cubbage, James M.↗

Pitot survey of exhaust flow field of a 2-D scramjet nozzle at Mach 6 with air or freon and argon used for exhaust simulation

A pitot-rake survey of the simulated exhaust of a half-span scramjet nozzle model was conducted in the Langley 20-Inch Mach 6 Tunnel to provide an additional data set for computational fluid dynamics (CFD) code comparisons. A wind-tunnel model was tested with a 26-tube pitot rake that could be manually positioned along the mid-semispan plane of the model. The model configuration had an external expansion surface of 20 degrees and an internal cowl expansion of 12 degrees; tests were also performed with a flow fence. Tests were conducted at a free-stream Reynolds number of approximately 6.5 x 10(exp 6) per foot and a model angle of attack of -0.75 degrees. The two exhaust gas mediums that were tested were air and a Freon 12-argon mixture. Each medium was tested at two jet total pressures at approximately 28 and 14 psia. This document presents the flow-field survey results in graphical as well as tabular form, and several observations concerning the results are discussed. The surveys reveal the major expected flow-field characteristics for each test configuration. For a 50-percent freon 12 and 50-percent argon mixture by volume (Fr-Ar), the exhaust jet pressures were slightly higher than those for air. The addition of a flow fence slightly raised the pitot pressure for the Fr-Ar mixture, but it produced little change for air. For the Fr-Ar exhaust, the plume was larger and the region between the shock wave and plume was smaller.

Monta, William J.↗

Gas-Chromatographic Determination Of Water In Freon PCA

Gas-chromatographic apparatus measures small concentrations of water in specimens of Freon PCA. Testing by use of apparatus faster and provides greater protection against accidental contamination of specimens by water in testing environment. Automated for unattended operation. Also used to measure water contents of materials, other than Freon PCA. Innovation extended to development of purgeable sampling accessory for gas chromatographs.

Melton, Donald M.↗