Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREQUENCY CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Continuous Under-Frequency Load Shedding Scheme for Power System Adaptive Frequency Control

Frequency drop due to loss of massive generation is a threat to power system frequency stability. Under-frequency load shedding (UFLS) is the principal measure to prevent successive frequency declination and blackouts. Based on traditional stage-by-stage UFLS scheme, a new continuous UFLS scheme is proposed in this paper to shed loads proportional to frequency deviation. The characteristic of the proposed scheme is analyzed with a closed-form solution of frequency dynamics. Frequency threshold and time delay are added to make the proposed scheme practical. A line-by-line scheme based on precise load control is introduced to implement the continuous scheme for systems without enough continuously controllable loads. The load shedding scale factor of the proposed scheme is tuned with an analytical method to achieve adaptability to different operating conditions. Furthermore, the adaptability of the proposed scheme is validated with 39-bus New England model and simplified Shandong Power Grid of China.

42 ENGINEERING↗

Digital frequency control of satellite frequency standards

In the Frequency and Time Standard Development Program of the TIMATION System, a new miniaturized rubidium vapor frequency standard has been tested and analyzed for possible use on the TIMATION 3A launch, as part of the Defense Navigation Satellite Development Program. The design and construction of a digital frequency control was required to remotely control this rubidium vapor frequency standard as well as the quartz oscillator in current use. This control must be capable of accepting commands from a satellite telemetry system, verify that the correct commands have been sent and control the frequency to the requirements of the system. Several modifications must be performed to the rubidium vapor frequency standard to allow it to be compatible with the digital frequency control. These include the addition of a varactor to voltage tune the coarse range of the flywheel oscillator, and a modification to supply the C field current externally. The digital frequency control for the rubidium vapor frequency standard has been successfully tested in prototype form.

Nichols, S. A.↗

Distributional Deep Reinforcement Learning-Based Emergency Frequency Control

Emergency frequency control is one of the most critical approaches to maintain power system stability after major disturbances. With the increasing number of grid-connected renewable energy sources, existing model-based methods of frequency control are facing up with challenges of computational speed and scalability for large-scale systems. In this paper, the emergency frequency control problem is formulated as a Markov Decision Process (MDP) and solved through a novel Distributional Deep Reinforcement Learning (DDRL) method, namely the distributional soft actor critic (DSAC) method. Compared with other RL methods that only estimate the mean value, the proposed DSAC model estimates the distribution of value function over returns. This advancement can lead to more insights and knowledge for the agent, with the benefit of a much faster and more stable learning process, and the improved frequency control performance. Here, the simulation results on IEEE 39-bus and IEEE 118-bus systems demonstrate the effectiveness and robustness of proposed models, as well as the advantage compared to other state-of-the-art DRL algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Machine Learning-Based PV Reserve Determination Strategy for Frequency Control on the WECC System

Frequency control from photovoltaic (PV) power plants has great potential to address the frequency response challenge of the power system with high penetrations of renewable generation. Using model-based approaches to determine the optimal PV headroom reserve, however, requires significant online computation and is intractable for an interconnection level system. This paper proposes a machine learning based strategy, that is suitable for real-time operation, to determine the optimal PV reserve for frequency control. The proposed machine learning algorithm is trained and tested on 1,987 offline simulations of a 60% renewable penetration Western Electricity Coordinating Council (WECC) system. Furthermore, the proposed reserve determination strategy is applied on a realistic 1-day operation profile of the WECC system and demonstrates a savings of more than 40% PV headroom compared to a conservative approach. It is evident that the proposed strategy can efficiently and effectively determine the optimal PV frequency control reserve for realistic interconnection systems.

frequency control↗

Capability-Coordinated Frequency Control Scheme of a Virtual Power Plant with Renewable Energy Sources

Growing trends in the deployment of inverter-based renewable energy will decrease the inertia and frequency control capability of electric power systems by replacing conventional power plants; thus, the frequency of future power systems might be dynamic. This study proposes a capability-coordinated frequency control (CCFC) scheme of a virtual power plant (VPP) including adjustable-speed pumped storage hydropower (AS-PSH), a wind power plant (WPP), and an energy storage system to support the frequency nadir and reduce the steady-state error of system frequency. The CCFC scheme is based on a hierarchical-control structure in which a CCFC organises the output of local frequency control units. To support the frequency nadir, the CCFC dispatches weighted frequency errors that are proportional to the available headroom of the units; thus, the errors are forwarded separately with a system frequency error to the primary control loop of each unit and thereby arrest the frequency nadir at a higher value than a system without the CCFC. To reduce the steady-state error of the system frequency, the CCFC determines a partial active power command by additionally feeding an integrator of the CCFC with a modified frequency error that depends on the unit with the largest control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reinforcement Learning-based Output Structured Feedback for Distributed Multi-Area Power System Frequency Control

Load frequency control (LFC) is a key factor to maintain the stable frequency in multi-area power systems. As the modern power systems evolve from centralized to decentralized paradigm, LFC needs to consider the decentralized scheme that considers limited information from the information-exchange graph for the generator control of each interconnected area. This paper aims to solve a data-driven constrained LQR problem with mean-variance risk constraints and output structured feedback, and applies this framework to solve the LFC problem in multi-area power systems. By reformulating the constrained optimization problem into a minimax problem, the stochastic gradient descent max-oracle (SGDmax) algorithm with zero-order policy gradient (ZOPG) is adopted to find the optimal feedback gain from the learning, while guaranteeing the convergence. In addition, to improve the adaptation of the proposed learning method to new or varying models, we construct an emulator grid that approximates the dynamics of a physical grid and performs training based on this model. Once the feedback gain is obtained from the emulator grid, it is applied to the physical grid with a robustness test to check whether the controller from the approximated emulator applies to the actual system. Numerical tests show that the obtained feedback controller can successfully control the frequency of each area, while mitigating the uncertainty from the loads, with reliable robustness that ensures the adaptability of the obtained feedback gain to the actual physical grid.

Kwon, Kyung-bin↗

The optimal control frequency response problem in manual control

An optimal control frequency response problem is defined within the context of the optimal pilot model. The problem is designed to specify pilot model control frequencies reflective of important aircraft system properties, such as control feel system dynamics, airframe dynamics, and gust environment, as well as man machine properties, such as task and attention allocation. This is accomplished by determining a bounded set of control frequencies which minimize the total control cost. The bounds are given by zero and the neuromuscular control frequency response for each control actuator. This approach is fully adaptive, i.e., does not depend upon user entered estimates. An algorithm is developed to solve this optimal control frequency response problem. The algorithm is then applied to an attitude hold task for a bare airframe fighter aircraft case with interesting dynamic properties.

Harrington, W. W.↗

Gyrotropic frequency control in ferromagnetic dots using a nanoscale vortex barrier

The vortex translational mode frequency is known to be only weakly dependent on the magnitude of an in-plane magnetic field (e.g. the vortex core position) for circular ferromagnetic dots. Here we demonstrated that the frequency-field dependence becomes discrete when a nanoscale vortex barrier is introduced in the dot structure. We found that the frequency is mostly defined by the outer diameter of the dot or the barrier size for the vortex core located outside or inside the barrier, correspondingly. The experimental results are in good agreement with the micromagnetic simulation.

Ding, Junjia↗

Automatic oscillator frequency control system

A frequency control system makes an initial correction of the frequency of its own timing circuit after comparison against a frequency of known accuracy and then sequentially checks and corrects the frequencies of several voltage controlled local oscillator circuits. The timing circuit initiates the machine cycles of a central processing unit which applies a frequency index to an input register in a modulo-sum frequency divider stage and enables a multiplexer to clock an accumulator register in the divider stage with a cyclical signal derived from the oscillator circuit being checked. Upon expiration of the interval, the processing unit compares the remainder held as the contents of the accumulator against a stored zero error constant and applies an appropriate correction word to a correction stage to shift the frequency of the oscillator being checked. A signal from the accumulator register may be used to drive a phase plane ROM and, with periodic shifts in the applied frequency index, to provide frequency shift keying of the resultant output signal. Interposition of a phase adder between the accumulator register and phase plane ROM permits phase shift keying of the output signal by periodic variation in the value of a phase index applied to one input of the phase adder.

Smith, S. F.↗

Frequency Control Performance Measurement and Requirements

Frequency control is an essential requirement of reliable electric power system operations. Determination of frequency control depends on frequency measurement and the practices based on these measurements that dictate acceptable frequency management. This report chronicles the evolution of these measurements and practices. As technology progresses from analog to digital for calculation, communication, and control, the technical basis for frequency control measurement and practices to determine acceptable performance continues to improve. Before the introduction of digital computing, practices were determined largely by prior experience. In anticipation of mandatory reliability rules, practices evolved from a focus primarily on commercial and equity issues to an increased focus on reliability. This evolution is expected to continue and place increased requirements for more precise measurements and a stronger scientific basis for future frequency management practices in support of reliability.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Ultrastable automatic frequency control

Center frequency of wideband AFC circuit drifts only hundredths of percent per day. Since circuit responds only to slow frequency drifts and modulation signal has high-pass characteristics, AFC does not interfere with normal FM operation. Stable oscillator, reset circuit, and pulse generator constitute time-averaging discriminator; digital counter in pulse generator replaces usual monostable multivibrator.

Sabourin, D. J.↗

Machine Learning-Based PV Reserve Determination Strategy for Frequency Control on the WECC System: Preprint

Frequency control from Photovoltaic (PV) plants has great potential to address the frequency response challenge of the power system with high renewable penetration. However, using model-based approaches to determine the optimal PV headroom reserve requires significant online computation and is intractable for an interconnection level system. This paper proposes a machine learning based strategy, that is suitable for real-time operation, to determine the optimal PV reserve for frequency control. The proposed machine learning algorithm is trained and tested on 1,987 offline simulations of a 60% renewable penetration Western Electricity Coordinating Council (WECC) system. Furthermore, the proposed reserve determination strategy is applied on a realistic one-day operation profile of the WECC system and demonstrates over 40% PV headroom saving compared to a conservative approach. It is evident that the proposed strategy can efficiently and effectively determine the optimal PV frequency control reserve for realistic interconnection systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Frequency control of tunable lasers using a frequency-calibrated λ-meter in an experiment on preparation of Rydberg atoms in a magneto-optical trap

A new technique is proposed and applied to study the frequency drift of an external-cavity semiconductor laser, locked to the transmission resonances of a thermally stabilised Fabry–Perot interferometer. The interferometer frequency drift is measured to be less than 2 MHz h{sup -1}. The laser frequency is measured using an Angstrom wavemeter, calibrated using an additional stabilised laser. It is shown that this system of laser frequency control can be used to identify Rydberg transitions in ultracold {sup 7}Li atoms. (control of laser radiation parameters)

74 ATOMIC AND MOLECULAR PHYSICS↗

An extended Kalman filter based automatic frequency control loop

An Automatic Frequency Control (AFC) loop based on an Extended Kalman Filter (EKF) is introduced and analyzed in detail. The scheme involves an EKF which operates on a modified set of data in order to track the frequency of the incoming signal. The algorithm can also be viewed as a modification to the well known cross-product AFC loop. A low carrier-to-noise ratio (CNR), high-dynamic environment is used to test the algorithm and the probability of loss-of-lock is assessed via computer simulations. The scheme is best suited for scenarios in which the frequency error variance can be compromised to achieve a very low operating CNR threshold. This technique can easily be incorporated in the Advanced Receiver (ARX), requiring minimum software modifications.

Hinedi, S.↗

Synchronous generator modeling and frequency control using unscented Kalman filter

Various examples are related to synchronous generator modeling with frequency control, which can be achieved using unscented Kalman filtering. In one example, a method includes obtaining operational parameters associated with a generator of a power system; determining parameters of a synchronous generator model with frequency control based at least in part upon the operational parameters associated with the generator; and providing a command to a frequency control of the generator, the command updating one or more parameters of the frequency control. In another example, a system includes a generator controller for a generator of a power system; and a computing device in communication with the generator controller, where the computing device is configured to determine parameters of the synchronous generator model using operational parameters associated with the generator and provide a command updating one or more parameters of a frequency control of the generator controller.

24 POWER TRANSMISSION AND DISTRIBUTION↗