Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREQUENCY RESPONSE TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Device, system, and method for measuring internal impedance of a test battery using frequency response

Battery impedance testing devices, circuits, systems, and related methods are disclosed. An impedance measurement device includes a current driver configured to generate an excitation current signal to be applied to a test battery responsive to a control signal, and a processor operably coupled with the current driver. The processor is configured to generate the control signal during an auto-ranging mode and a measuring mode. The auto-ranging mode applies the excitation current signal to the test battery over a plurality of different amplitudes to measure a response to the excitation current signal at each amplitude. The measuring mode applies the excitation current signal to the test battery for an amplitude responsive to the results of the auto-ranging mode. Improved sensitivity and resolution may be achieved for low impedance batteries with a rapid measurement time.

25 ENERGY STORAGE↗

SAM Code Validation using the Compact Integral Effects Test (CIET) Experimental Data

The primary objective of this study is to validate the system analysis code, SAM, using experimental data from the Compact Integral Effects Test (CIET) facility. The System Analysis Module (SAM) is an advanced and modern system analysis tool being developed at Argonne National Laboratory under the U.S. DOE Office of Nuclear Energy’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. Originally aiming at supporting sodium fast reactor (SFR) design, it is now extended to cover other non-light water reactor (non-LWR) concepts, such as high-temperature gas-cooled reactor (HTGR) designs, molten salt-fueled, and molten salt-cooled reactor designs. To support SAM code development for the wide range of non-LWR applications, it is of paramount importance to validate the code against experiments relevant to these reactor concepts. The Compact Integral Effects Test (CIET) facility, which was designed to reproduce the thermal-hydraulics response of fluoride salt-cooled high-temperature reactors (FHR) under both forced- and natural-circulation conditions, has been identified and selected as one of benchmark test facilities for SAM code validation. Among available CIET experiments, three sets of them with distinctive characteristics were selected for SAM code validation purpose. The three sets experiments are: 1) Power step change transient tests; 2) DHX-DRACS natural circulation tests; and 3) heater frequency response tests. For all tests, steady-state or transient, SAM-predicted results show very good agreement with experimental data. The successful validation of SAM against these selected CIET experiments demonstrates that the computer code is well suited for thermal-hydraulics analysis of FHR designs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High-Temperature Sapphire Pressure Sensors for Harsh Environments

The project aimed to develop and characterize an optical pressure sensor capable of withstanding high temperatures, up to 1000 °C. Survivability in harsh environments was enabled using sapphire for both the substrate and the optical fibers, therefore mitigating thermal expansion mismatch. Such material cannot be machined through conventional microfabrication techniques, and unique additive and subtractive methods had to be studied and implemented. Subtractive methods included laser-machining the sapphire substrate using a picosecond laser machining tool. At first, the parameters of importance were theoretically and experimentally evaluated such that the fluence, the pulse spacing, and the number of passes were found to strongly influence the laser ablation process. A simulation tool was designed to predict the final pattern when inputting a set of parameters and a profile. This model was complemented with laser ablation material physics models and Bayesian uncertainty analysis for one dimensional and three dimensional ablation processes. An additive process called thermocompression bonding was studied in order to seal the diaphragm substrate to the back cavity. At first, bonding strength using this technique was examined using the chevron-notch method that allow to determine the fracture toughness of this bond. This parameter is independent of the geometry used and therefore can be extended to other geometries used in actual sensor bonding. A theoretical and experimental study of internal damage caused by the laser micromachining of the sapphire material was carried out. The research identified enhanced strength and fracture toughness along laser ablated surfaces. This was determined using bend bar specimens and Vicker’s microindentations. Softening of the plasticity behavior (as indicated by nanoindentation experiments) was also investigated using finite deformation plasticity modeling via a contact mechanics finite element simulation. Good correlations between experiments and the model were achieved to determine material parameters that can be used in future MEMS based sensor design and modeling to minimize sensor failure loads. The enhanced strength and fracture toughness was determined to be due to compressive residual stress near laser ablated surfaces. This was confirmed through x-ray spectra taken along different crystal structure planes in combination and Bayesian uncertainty analysis. The Bayesian analysis inferred the entire residual strain tensor (six components) and the residual stress tensor. The results illustrated compressive in-plane stress was the most likely cause of enhanced strength and toughness after laser machining. Due to major equipment failures, a parallel route for fabricating the sensor was taken, using commercially available sapphire removal method (subtractive) and ceramic adhesive bonding (additive). The fully-packaged sensor utilized laser micromachining for the sapphire substrate fabrication and was comprised only of high-temperature-compatible materials. Calibration tests of the sensor in both room-temperature and high-temperature plane-wave tubes showed good linearity and consistent frequency response, in the tested frequency range. The sensor also showed good thermal stability in tests up to 300 °C, proving the fiber-optic lever and its packaging process to be a promising approach for high-temperature measurements. The calibration from 23 °C to 300 °C gave a raw sensitivity of 3.9 × 10 -7 V/Pa and a normalized sensitivity of 9.8 × 10 -8 Pa -1 which were consistent within the temperature range. The sensor had a resonance at 16.3 kHz and a flat band (±3 dB) up to 10.3 kHz. The noise floor of the sensor at 1 kHz was 316 nV/Hz 1/2 , resulting in a MDP of 0.8 Pa. Previously, diaphragm delamination due to CTE mismatch was found at 500 °C, causing packaging failure. Unfortunately high temperature validation in hot jet environment could not be made in time. In the future, it is suggested that the two sapphire substrates be bonded by thermal compression bonding with an intermediate platinum layer instead of using an alumina-based adhesive, and therefore achieve higher temperature capacity up to 1000 °C.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Spinning Reserve From Hotel Load Response: Initial Progress

This project was motivated by the fundamental match between hotel space conditioning load response capability and power system contingency response needs. As power system costs rise and capacity is strained demand response can provide a significant system reliability benefit at a potentially attractive cost. At ORNL s suggestion, Digital Solutions Inc. adapted its hotel air conditioning control technology to supply power system spinning reserve. This energy saving technology is primarily designed to provide the hotel operator with the ability to control individual room temperature set-points based upon occupancy (25% to 50% energy savings based on an earlier study [Kirby and Ally, 2002]). DSI added instantaneous local load shedding capability in response to power system frequency and centrally dispatched load shedding capability in response to power system operator command. The 162 room Music Road Hotel in Pigeon Forge Tennessee agreed to host the spinning reserve test. The Tennessee Valley Authority supplied real-time metering equipment in the form of an internet connected Dranetz-BMI power quality meter and monitoring expertise to record total hotel load during both normal operations and test results. The Sevier County Electric System installed the metering. Preliminary testing showed that hotel load can be curtailed by 22% to 37% depending on the outdoor temperature and the time of day. These results are prior to implementing control over the common area air conditioning loads. Testing was also not at times of highest system or hotel loading. Full response occurred in 12 to 60 seconds from when the system operator s command to shed load was issued. The load drop was very rapid, essentially as fast as the 2 second metering could detect, with all units responding essentially simultaneously. Load restoration was ramped back in over several minutes. The restoration ramp can be adjusted to the power system needs. Frequency response testing was not completed. Initial testing showed that the units respond very quickly. Problems with local power quality generated false low frequency signals which required testing to be stopped. This should not be a problem in actual operation since the frequency trip points will be staggered to generate a droop curve which mimics generator governor response. The actual trip frequencies will also be low enough to avoid power quality problems. The actual trip frequencies are too low to generate test events with sufficient regularity to complete testing in a reasonable amount of time. Frequency response testing will resume once the local power quality problem is fully understood and reasonable test frequency settings can be determined. Overall the preliminary testing was extremely successful. The hotel response capability matches the power system reliability need, being faster than generation response and inherently available when the power system is under the most stress (times of high system and hotel load). Periodic testing is scheduled throughout the winter and spring to characterize hotel response capability under a full range of conditions. More extensive testing will resume when summer outdoor temperatures are again high enough to fully test hotel response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Beta Test Plan for Advanced Inverters Interconnecting Distributed Resources with Electric Power Systems

This document provides a preliminary (beta) test plan for grid interconnection systems of advanced inverter-based DERs. It follows the format and methodology/approach established by IEEE Std 1547.1, while incorporating: 1. Upgraded tests for responses to abnormal voltage and frequency, and also including ride-through. 2. A newly developed test for voltage regulation, including dynamic response testing. 3. Modified tests for unintentional islanding, open phase, and harmonics to include testing with the advanced voltage and frequency response functions enabled. Two advanced inverters, one single-phase and one three-phase, were tested under the beta test plan. These tests confirmed the importance of including tests for inverter dynamic response, which varies widely from one inverter to the next.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Power Electron Accelerators for Space (and other) Applications

This is a presentation on high-power electron accelerators for space and other applications. The main points covered are: electron beams for space applications, new designs of RF accelerators, high-power high-electron mobility transistors (HEMT) testing, and Li-ion battery design. In summary, the authors have considered a concept of 1-MeV electron accelerator that can operate up to several seconds. This concept can be extended to higher energy to produce higher beam power. Going to higher beam energy requires adding more cavities and solid-state HEMT RF power devices. The commercial HEMT have been tested for frequency response and RF output power (up to 420 W). Finally, the authors are testing these HEMT into a resonant load and planning for an electron beam test in FY17.

43 PARTICLE ACCELERATORS↗

Variable frequency response testbed to validate protective relays up to 20 kHz☆

Microgrids operate in islanding or utility grid mode. In islanding mode, distributed energy sources with power electronics inverters can generate fault currents over a wide range of frequencies. To gain a better understanding of the nature of these events, it is crucial to measure currents at frequencies of up to 20 kHz at transient states with protective relays. Protective relays at these frequency responses should be tested prior to being installed in microgrids. However, testing at high-frequency currents cannot be done with Relay Test Equipment (RTE) that generate signals up to 50th Harmonic for 60 Hz (3 kHz). In this study, a frequency response method and testbed for high-frequency currents of up to 20.16 kHz was developed and tested. The testbed utilized a RTE and High-Frequency Power Source/ Amplifier. Furthermore, frequency relay experiments were run at frequencies of up to 1 and 20.16 kHz at a current magnitude of 0.1 and 0.5 A, respectively. The events were collected, and the current magnitude and frequency were plotted at time and frequency domain, respectively. The study of current magnitude and frequencies of up to 20.16 kHz for two overcurrent relays was performed and validated the variable frequency testbed and methodology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design, analysis and testing of a parallel-kinematic high-bandwidth XY nanopositioning stage

This paper presents the design, analysis, and testing of a parallel-kinematic high-bandwidth XY nanopositioning stage driven by piezoelectric stack actuators. The stage is designed with two kinematic chains. In each kinematic chain, the end-effector of the stage is connected to the base by two symmetrically distributed flexure modules, respectively. Each flexure module comprises a fixed-fixed beam and a parallelogram flexure serving as two orthogonal prismatic joints. With the purpose to achieve high resonance frequencies of the stage, a novel center-thickened beam which has large stiffness is proposed to act as the fixed-fixed beam. The center-thickened beam also contributes to reducing cross-coupling and restricting parasitic motion. To decouple the motion in two axes totally, a symmetric configuration is adopted for the parallelogram flexures. Based on the analytical models established in static and dynamic analysis, the dimensions of the stage are optimized in order to maximize the first resonance frequency. Then finite element analysis is utilized to validate the design and a prototype of the stage is fabricated for performance tests. According to the results of static and dynamic tests, the resonance frequencies of the developed stage are over 13.6 kHz and the workspace is 11.2 μm × 11.6 μm with the cross-coupling between two axes less than 0.52%. It is clearly demonstrated that the developed stage has high resonance frequencies, a relatively large travel range, and nearly decoupled performance between two axes. For high-speed tracking performance tests, an inversion-based feedforward controller is implemented for the stage to compensate for the positioning errors caused by mechanical vibration. The experimental results show that good tracking performance at high speed is achieved, which validates the effectiveness of the developed stage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility of using thermal response methods for nonintrusive compressed air flow measurement

Robust, low-cost nonintrusive flow meters are of interest in many industries. Particularly, a reliable nonintrusive flow measurement for the diagnosis of air leaks in compressed air systems is desirable. Measurement of the air flow due to leaks in the system ensures an accurate estimation of potential cost and energy savings. This study evaluates a novel method of using thermal responses to nonintrusively measure leakage rates in compressed air lines. The method uses heat and the resulting thermal response to calculate the flow rate inside the compressed air line. Compared to the current methods for flow measurement, this method can simplify flow measurement while decreasing the sensitivity to errors when measuring flow rates. In this study, the methodology of the proposed method is explained along with the potential advantages to the design. Two approaches are evaluated: a dynamic step response and sinusoidal frequency response. Simulated tests evaluate the feasibility of the proposed methods, followed by experiments that validate the simulation results. A clear correlation between the thermal step response and the flow rate indicate viability of the proposed method in simulation. Experimental results yielded similar results, confirming the validity of the proposed method. The results of a field test in an industrial environment demonstrate the capability of the approach to other flow rate measurement techniques.

42 ENGINEERING↗

Effects of gold patterning on the bending profile and frequency response of a microcantilever

We have systematically investigated the effect of various gold patterns on the bending profile and frequency response of a microcantilever. The gold patterns were deposited on the cantilever arrays using four types of shadow mask. The local bending profile, slope, and curvature varied depending on the area and position of the gold pattern. Also, the variations in the first three modes of the flexural resonance frequencies of the gold patterned cantilevers were measured to understand the opposing effects of mass loading and flexural rigidity; both of these parameters are dependent on the position and area of the gold pattern. The experimental results validated the theoretical one-dimensional model introduced by Tamayo et al. Appl. Phys. Lett. 89, 224104 2006 and our calculations using the finite element method. The gold patterns giving the maximum response of the mass loading and flexural rigidity change were determined by examining how the relative resonance frequency shifts as a function of the distance of the gold coating from the free end or clamping region. The results of this study can potentially be applied in the design of a microcantilever sensor in which pattern analysis is utilized to determine the presence of adsorbed biological and chemical molecules.

42 ENGINEERING↗

Calculations of two-fluid linear response to non-axisymmetric fields in tokamaks

The zero-frequency linear plasma response to static applied non-axisymmetric fields is calculated using a resistive two-fluid model in diverted, toroidal geometry. Within this model, the effects on the plasma response of resistivity, rotation, differential ion and electron velocity, and dissipation are explored. Rotation is generally found to inhibit the formation of islands in the plasma, in qualitative agreement with theoretical results. When two-fluid effects are included, it is found that the penetration of the non-axisymmetric fields is generally greatest when the part of the electron rotation perpendicular to the equilibrium magnetic field is small at the mode-rational surface. Strong rotation shear in the edge is found to enhance the plasma response there. The entire plasma, including the separatrix and scrape-off layer, is included in the computational domain.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Asymptotic method for constructing a dynamic frequency response of a laser gyro

We consider an equation describing the dynamics of the phase of a beat signal at the output of a ring laser gyro in the presence of an alternating-sign frequency biasing in the form of a superposition of two meanders with different amplitudes and periods. It is assumed that the amplitude of one of the meanders is much larger than that of the other as well as than the half-widths of the static lock-in and the measured difference of eigenfrequencies of a ring resonator. A method is proposed for approximately calculating the beat frequency as a function of the measured difference between the eigenrequencies of the resonator. The result of applying this method represents analytically a recursive algorithm. Its implementation on a computer has made it possible to construct a dynamic frequency (output) response of a laser gyro with a biasing of given form. (laser applications and other topics in quantum electronics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Apparatuses and methods for testing electrochemical cells by measuring frequency response

Real-time battery impedance spectra are acquired by stimulating a battery or battery system with a signal generated as a sum of sine signals at related frequencies. An impedance measurement device can be used to interface between the battery system and a host computer for generating the signals. The impedance measurement device may be calibrated to adapt the response signal to more closely match other impedance measurement techniques. The impedance measurement device may be adapted to operate at mid-range voltages of about 50 volts and high-range voltages up to about 300 volts.

25 ENERGY STORAGE↗

Apparatuses and methods for testing electrochemical cells by measuring frequency response

Real-time battery impedance spectra are acquired by stimulating a battery or battery system with a signal generated as a sum of sine signals at related frequencies. An impedance measurement device can be used to interface between the battery system and a host computer for generating the signals. The impedance measurement device may be calibrated to adapt the response signal to more closely match other impedance measurement techniques. The impedance measurement device may be adapted to operate at mid-range voltages of about 50 volts and high-range voltages up to about 300 volts.

Christophersen, Jon P.↗

First Principles Modeling of RFQ Cooling System and Resonant Frequency Responses for Fermilab’s PIP-II Injector Test

In this study we develop an a priori method for simulating dynamic resonant frequency and temperature responses in a radio frequency quadrupole (RFQ) and its associated water-based cooling system respectively. Our model provides a computationally efficient means to evaluate the transient response of the RFQ over a large range of system parameters. The model was constructed prior to the delivery of the PIP-II Injector Test RFQ and was used to aid in the design of the water-based cooling system, data acquisition system, and resonance control system. Now that the model has been validated with experimental data, it can confidently be used to aid in the design of future RFQ resonance controllers and their associated water-based cooling systems. Finally, without any empirical fitting, it has demonstrated the ability to predict absolute temperature and frequency changes to 11% accuracy on average, and relative changes to 7% accuracy.

43 PARTICLE ACCELERATORS↗

A Testing Framework for Grid-Forming Resources: Preprint

This paper presents a testing framework for grid-forming (GFM) resources. It first analytically derives in frequency domain the active and reactive power response of an ideal voltage source with a reactor. These transfer functions are then used to quantify the voltage source behavior expected from a GFM inverter within subtransient time scales (5-10 cycles) following a grid disturbance. The paper also shows that the testing of a GFM inverter might require a reactor of an appropriate size between the inverter and the grid simulator used for the inverter testing. Finally, the paper presents a systematic approach for developing specifications for GFM resources using active and reactive power response frequency scans. The testing framework and results presented in this paper are demonstrated using EMT simulations of a 1-MW GFM inverter.

frequency scans↗

A Testing Framework for Grid-Forming Resources

This paper presents a testing framework for grid-forming (GFM) resources. First, it analytically derives in the frequency domain the active and reactive power response of an ideal voltage source with a reactor. These transfer functions are then used to quantify the voltage source behavior expected from a GFM inverter within subtransient timescales (5-15 cycles) following a grid disturbance. The paper also shows that the testing of a GFM inverter might require a reactor of an appropriate size between the inverter and the grid simulator used for the inverter testing. Finally, the paper presents a systematic approach for developing specifications for GFM resources using active and reactive power response frequency scans. The testing framework and results presented in this paper are demonstrated using EMT-PSCAD simulations of a 1-MW GFM inverter.

frequency scans↗