Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREQUENCY STANDARD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

F-state quenching with CH{sub 4} for buffer-gas cooled {sup 171}Y b{sup +} frequency standard

We report that methane, CH{sub 4}, can be used as an efficient F-state quenching gas for trapped ytterbium ions. The quenching rate coefficient is measured to be (2.8 ± 0.3) × 10{sup 6} s{sup −1} Torr{sup −1}. For applications that use microwave hyperfine transitions of the ground-state {sup 171}Y b ions, the CH{sub 4} induced frequency shift coefficient and the decoherence rate coefficient are measured as δν/ν = (−3.6 ± 0.1) × 10{sup −6} Torr{sup −1} and 1/T{sub 2} = (1.5 ± 0.2) × 10{sup 5} s{sup −1} Torr{sup −1}. In our buffer-gas cooled {sup 171}Y b{sup +} microwave clock system, we find that only ≤10{sup −8} Torr of CH{sub 4} is required under normal operating conditions to efficiently clear the F-state and maintain ≥85% of trapped ions in the ground state with insignificant pressure shift and collisional decoherence of the clock resonance.

74 ATOMIC AND MOLECULAR PHYSICS↗

Microfabricated ion frequency standard

A microfabricated ion frequency standard (i.e. an ion clock) is disclosed with a permanently-sealed vacuum package containing a source of ytterbium (Yb) ions and an octupole ion trap. The source of Yb ions is a micro-hotplate which generates Yb atoms which are then ionized by a ultraviolet light-emitting diode or a field-emission electron source. The octupole ion trap, which confines the Yb ions, is formed from suspended electrodes on a number of stacked-up substrates. A microwave source excites a ground-state transition frequency of the Yb ions, with a frequency-doubled vertical-external-cavity laser (VECSEL) then exciting the Yb ions up to an excited state to produce fluorescent light which is used to tune the microwave source to the ground-state transition frequency, with the microwave source providing a precise frequency output for the ion clock.

Schwindt, Peter↗

THE IMPACT OF FREQUENCY STANDARDS ON COHERENCE IN VLBI AT THE HIGHEST FREQUENCIES

We have carried out full imaging simulation studies to explore the impact of frequency standards in millimeter and submillimeter very long baseline interferometry (VLBI), focusing on the coherence time and sensitivity. In particular, we compare the performance of the H-maser, traditionally used in VLBI, to that of ultra-stable cryocooled sapphire oscillators over a range of observing frequencies, weather conditions, and analysis strategies. Our simulations show that at the highest frequencies, the losses induced by H-maser instabilities are comparable to those from high-quality tropospheric conditions. We find significant benefits in replacing H-masers with cryocooled sapphire oscillator based frequency references in VLBI observations at frequencies above 175 GHz in sites which have the best weather conditions; at 350 GHz we estimate a 20%-40% increase in sensitivity over that obtained when the sites have H-masers, for coherence losses of 20%-10%, respectively. Maximum benefits are to be expected by using co-located Water Vapor Radiometers for atmospheric correction. In this case, we estimate a 60%-120% increase in sensitivity over the H-maser at 350 GHz.

74 ATOMIC AND MOLECULAR PHYSICS↗

Microwave frequency standard on {sup 25}Mg{sup +} ions: expected characteristics and prospects

A scheme of the new frequency standard is reported based on a microwave transition between hyperfine components of the ground state in {sup 25}Mg{sup +} ions. It is proposed to capture ions into a linear quadrupole Paul trap and to perform the laser cooling, as well as to prepare the particle ensemble and to implement detection by using a single laser system based on a semiconductor laser. Characteristics of the suggested frequency standard are estimated. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of the systematic shifts of a single-{sup 40}Ca{sup +}-ion frequency standard

Progress on the evaluation of systematic frequency shifts is described in the development of the optical frequency standard based on single-trapped {sup 40}Ca{sup +} with a ''clock'' transition at 729 nm. The overall systematic uncertainty of the 4s {sup 2} S{sub 1/2}-3d {sup 2} D{sub 5/2} clock resonance has been characterized to be 7.8 x 10{sup -16}. This uncertainty is at a level similar to the Cs fountain primary standard, while the potential stability for the {sup 40}Ca{sup +} clock exceeds that of Cs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Note: A novel design of a microwave feed for a microwave frequency standard with a linear ion trap

Linear ion traps are important tools in many applications, particularly in mass spectrum analyzers and frequency standards. Here a novel design of a microwave feed integrated into one electrode of a linear quadrupole ion trap is demonstrated for the application of a microwave frequency standard based on cadmium ions. The mechanical structure of the microwave feed is compact and easy to build. The ion trap integrated with this microwave feed is successfully applied to measure the hyperfine splitting of the ground state of {sup 113}Cd{sup +}, thus demonstrating the practicality and reliability of the microwave feed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser-pumped paraffin-coated cell rubidium frequency standard

We have realized and studied a rubidium atomic frequency standard based on a paraffin-coated cell, exhibiting a short-term frequency stability <3 Multiplication-Sign 10{sup -12} {tau}{sup -1/2} between {tau} = 1 and 100 s. Characterization of the wall-coating is performed by measuring the T{sub 1} and T{sub 2} relaxation times. Perturbations of the medium- to long-term clock stability, due to variations in the laser-intensity, laser frequency, the microwave power shift, and the shifts due to temperature variations are measured and analyzed. A method for reducing the intensity light-shift by detuning the laser frequency and the resulting improvement in clock stability is demonstrated. This work is of relevance for further improvements on Rb cell standards using anti-relaxation wall-coating technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Blackbody-radiation shift in a {sup 43}Ca{sup +} ion optical frequency standard

Motivated by the prospect of an optical frequency standard based on {sup 43}Ca{sup +}, we calculate the blackbody-radiation (BBR) shift of the 4s{sub 1/2}-3d{sub 5/2} clock transition, which is a major component of the uncertainty budget. The calculations are based on the relativistic all-order single-double method where all single and double excitations of the Dirac-Fock wave function are included to all orders of perturbation theory. Additional calculations are conducted for the dominant contributions in order to evaluate some omitted high-order corrections and estimate the uncertainties of the final results. The BBR shift obtained for this transition is 0.38(1) Hz. The tensor polarizability of the 3d{sub 5/2} level is also calculated and its uncertainty is evaluated as well. Our results are compared with other calculations.

74 ATOMIC AND MOLECULAR PHYSICS↗

Acousto-optic modulators for a controlled frequency shift of light beams in optical and microwave cold-atom frequency standards

A series of specialised acousto-optic modulators/frequency shifters based on paratellurite (TeO{sub 2}) single crystals is developed for systems of laser cooling and frequency stabilisation of laser sources in optical and microwave frequency standards based on cold strontium, rubidium and caesium atoms. The methods of calculation and optimisation of the main parameters of acousto-optic modulators are considered; their basic technical characteristics are experimentally investigated in the spectral range of optical radiation 460 – 900 nm and in the frequency shift range of 5 – 400 MHz. The modulators have a high diffraction efficiency, low power consumption and the ability to work with linearly and randomly polarised optical radiation. (frequency standards)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Potential of electric quadrupole transitions in radium isotopes for single-ion optical frequency standards

We explore the potential of the electric quadrupole transitions 7s {sup 2}S{sub 1/2}-6d {sup 2}D{sub 3/2}, 6d {sup 2}D{sub 5/2} in radium isotopes as single-ion optical frequency standards. The frequency shifts of the clock transitions due to external fields and the corresponding uncertainties are calculated. Several competitive {sup A}Ra{sup +} candidates, with A= 223-229, are identified. In particular, we show that the transition 7s {sup 2}S{sub 1/2} (F=2,m{sub F}=0)-6d {sup 2}D{sub 3/2} (F=0,m{sub F}=0) at 828 nm in {sup 223}Ra{sup +}, with no linear Zeeman and electric quadrupole shifts, stands out as a relatively simple case, which could be exploited as a compact, robust, and low-cost atomic clock operating at a fractional frequency uncertainty of 10{sup -17}. With more experimental effort, the {sup 223,225,226}Ra{sup +} clocks could be pushed to a projected performance reaching the 10{sup -18} level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stray-field-induced quadrupole shift and absolute frequency of the 688-THz {sup 171}Yb{sup +} single-ion optical frequency standard

We report experimental investigations of a single-ion optical frequency standard based on {sup 171}Yb{sup +}. The ion is confined in a cylindrically symmetric radiofrequency Paul trap. The reference transition is the {sup 2}S{sub 1/2}(F=0)-{sup 2}D{sub 3/2}(F{sup '}=2) electric quadrupole transition at 688 THz. Using a differential measurement scheme, we determine the shift of the reference transition frequency that occurs due to the interaction of the electric quadrupole moment of the {sup 2}D{sub 3/2} state with the gradient of the electrostatic stray field in the trap. We determine an upper limit for the instability of the quadrupole shift over times between 100 s to 20 h. We also observe the variations in the shift and in the applied stray-field compensation voltages that result from loading a new ion into the trap and during a subsequent storage period of 74 days. This information is utilized to measure the absolute frequency of the reference transition with an uncertainty that is a factor of 3 smaller than that of the previous measurement. Using a fiber laser based optical frequency comb generator and the cesium fountain clock CSF1 of PTB (Physikalisch-Technische Bundesanstalt), the frequency at 300 K temperature is determined as 688 358 979 309 306.62{+-}0.73 Hz.

74 ATOMIC AND MOLECULAR PHYSICS↗

Creation of the first Russian time and frequency standard on a fountain of ultracold rubidium atoms

Technical specific features of the first Russian rubidium frequency standard of a fountain type are described, which are distinct from those of abroad analogues. Test results of separate systems and the metrological characteristics of the standard are presented. The achievable output frequency instability is 4 × 10{sup −16} per measurement interval of 24 hours and 1 × 10{sup −16} per 16 days. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Frequency shift of an optical frequency standard as a function of probe modulation of the radiation frequency, pressure, and gas temperature in an absorbing cell

Frequency shifts of an optical Nd : YAG/I{sub 2}-standard are measured in a pressure range of molecular iodine 5 – 22 mTorr and deviation of probe modulation frequency 480 kHz – 4 MHz for the hyperfine structure component a1 of the molecular iodine absorption line R(56) 32 – 0. The frequency shift of the optical standard is estimated under varied temperatures of a cell and cell finger, which determines the pressure of the molecular iodine vapour. The requirements are defined to temperature stability of the cell and its finger for obtaining high long-term frequency stability of the optical frequency standard. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improvement of photovoltaic pumping systems based on standard frequency converters by means of programmable logic controllers

Photovoltaic pumping systems (PVPS) based on standard frequency converters (SFCs) are currently experiencing a growing interest in pumping programmes implemented in remote areas because of their high performance in terms of component reliability, low cost, high power range and good availability of components virtually anywhere in the world. However, in practical applications there have appeared a number of problems related to the adaptation of the SFCs to the requirements of the photovoltaic pumping systems (PVPS). Another disadvantage of dedicated PVPS is the difficulty in implementing maximum power point tracking (MPPT). This paper shows that these problems can be solved through the addition of a basic industrial programmable logic controller (PLC) to the system. This PLC does not increase the cost and complexity of the system, but improves the adaptation of the SFC to the photovoltaic pumping system, and increases the overall performance of the system. (author)

14 SOLAR ENERGY↗

Measurement of the Fundamental Thermal Noise Limit in a Cryogenic Sapphire Frequency Standard Using Bimodal Maser Oscillations

We report observations of the Schawlow-Townes noise limit in a cryogenic sapphire secondary frequency standard. The effect causes a fundamental limit to the frequency stability, and was measured through the novel excitation of a bimodal maser oscillation of a Whispering Gallery doublet at 12.04 GHz. The beat frequency of 10 kHz between the oscillations enabled a sensitive probe for this measurement of fractional frequency instability of 10{sup -14}{tau}{sup -1/2} with only 0.5 pW of output power.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the duration of continuous operation of an optical frequency standard based on strontium atoms

This paper examines methods for increasing the duration of autonomous continuous operation of optical frequency standards. We have realised the secondary cooling of strontium atoms without using phase stabilisation during the formation of cooling and intermixing light beams and proposed a clock laser frequency stabilisation algorithm that compensates for the acoustic noise-induced laser frequency instability. Experiments have been performed using two distinct algorithms for laser frequency stabilisation to the frequency of an atomic transition. The maximum duration of continuous autonomous operation of the system was 25 000 to 50 000 s with one stabilisation algorithm and 70 000 to 200 000 s with the other algorithm. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spectroscopy of the quadrupole clock transition of ytterbium-171 ions for optical frequency standard development

We outline the results of the spectroscopic investigation of the quadrupole transition of a single ytterbium-171 ion as applied to the development of an optical frequency standard with a relative uncertainty and long-term frequency instability of less than 10{sup −17}. The spectral width of the resonance recorded at the centre transition frequency amounts to about 30 Hz. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗