Search NASA⌕ Search

SEARCH · Search NASA

Results for “FSL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

NLS Flight Simulation Laboratory (FSL) documentation

The Flight Simulation Laboratory (FSL) Electronic Documentation System design consists of modification and utilization of the MSFC Integrated Engineering System (IES), translation of the existing FSL documentation to an electronic format, and generation of new drawings to represent the Engine Flight Simulation Laboratory design and implementation. The intent of the electronic documentation is to provide ease of access, local print/plot capabilities, as well as the ability to correct and/or modify the stored data by network users who are authorized to access this information.

Source record↗

Linear-depth quantum circuits for loading Fourier approximations of arbitrary functions

Abstract The ability to efficiently load functions on quantum computers with high fidelity is essential for many quantum algorithms, including those for solving partial differential equations and Monte Carlo estimation. In this work, we introduce the Fourier series loader (FSL) method for preparing quantum states that exactly encode multi-dimensional Fourier series using linear-depth quantum circuits. Specifically, the FSL method prepares a (Dn)-qubit state encoding the 2 Dn -point uniform discretization of aD-dimensional function specified by aD-dimensional Fourier series. A free parameter,m, which must be less thann, determines the number of Fourier coefficients, 2 D ( m + 1 ) , used to represent the function. The FSL method uses a quantum circuit of depth at most 2 ( n − 2 ) + ⌈ log 2 ( n − m ) ⌉ + 2 D ( m + 1 ) + 2 − 2 D ( m + 1 ) , which is linear in the number of Fourier coefficients, and linear in the number of qubits (Dn) despite the fact that the loaded function’s discretization is over exponentially many (2 Dn ) points. The FSL circuit consists of at most D n + 2 D ( m + 1 ) + 1 − 1 single-qubit and D n ( n + 1 ) / 2 + 2 D ( m + 1 ) + 1 − 3 D ( m + 1 ) − 2 two-qubit gates; we present a classical compilation algorithm with runtime O ( 2 3 D ( m + 1 ) ) to determine the FSL circuit for a given Fourier series. The FSL method allows for the highly accurate loading of complex-valued functions that are well-approximated by a Fourier series with finitely many terms. We report results from noiseless quantum circuit simulations, illustrating the capability of the FSL method to load various continuous 1D functions, and a discontinuous 1D function, on 20 qubits with infidelities of less than 10 −6 and 10 −3 , respectively. We also demonstrate the practicality of the FSL method for near-term quantum computers by presenting experiments performed on the Quantinuum H1-1 and H1-2 trapped-ion quantum computers: we loaded a complex-valued function on 3 qubits with a fidelity of over 95 % , as well as various 1D real-valued functions on up to 6 qubits with classical fidelities ≈99%, and a 2D function on 10 qubits with a classical fidelity ≈94%.

Physics↗

Noiseless Vlasov–Poisson simulations with linearly transformed particles

We introduce a deterministic discrete-particle simulation approach, the Linearly-Transformed Particle-In-Cell (LTPIC) method, that employs linear deformations of the particles to reduce the noise traditionally associated with particle schemes. Formally, transforming the particles is justified by local first order expansions of the characteristic flow in phase space. In practice the method amounts of using deformation matrices within the particle shape functions; these matrices are updated via local evaluations of the forward numerical flow. Because it is necessary to periodically remap the particles on a regular grid to avoid excessively deforming their shapes, the method can be seen as a development of Denavit's Forward Semi-Lagrangian (FSL) scheme (Denavit, 1972 [8]). However, it has recently been established (Campos Pinto, 2012 [20]) that the underlying Linearly-Transformed Particle scheme converges for abstract transport problems, with no need to remap the particles; deforming the particles can thus be seen as a way to significantly lower the remapping frequency needed in the FSL schemes, and hence the associated numerical diffusion. To couple the method with electrostatic field solvers, two specific charge deposition schemes are examined, and their performance compared with that of the standard deposition method. Finally, numerical 1d1v simulations involving benchmark test cases and halo formation in an initially mismatched thermal sheet beam demonstrate some advantages of our LTPIC scheme over the classical PIC and FSL methods. Benchmarked test cases also indicate that, for numerical choices involving similar computational effort, the LTPIC method is capable of accuracy comparable to or exceeding that of state-of-the-art, high-resolution Vlasov schemes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Induction of Protection in Mice against a Chlamydia muridarum Respiratory Challenge by a Vaccine Formulated with the Major Outer Membrane Protein in Nanolipoprotein Particles

Chlamydia trachomatis is a sexually transmitted bacterium that infects over 130 million individuals worldwide annually. To implement a vaccine, we developed a cell-free co-translational system to express the Chlamydia muridarum major outer membrane protein (MOMP). This approach uses a nanolipoprotein particles (tNLP) made from ApoA1 protein, amphiphilic telodendrimer and lipids that self-assemble to form 10–25 nm discs. These tNLP provide a protein-encapsulated lipid support to solubilize and fold membrane proteins. The cell-free system co-translated MOMP and ApoA1 in the presence of telodendrimer mixed with lipids. The MOMP-tNLP complex was amenable to CpG and FSL-1 adjuvant addition. To investigate the ability of MOMP-tNLP+CpG+FSL-1 to induce protection against an intranasal (i.n.) C. muridarum challenge, female mice were vaccinated intramuscularly (i.m.) or i.n. and i.m. simultaneously 4 weeks apart. Following vaccination with MOMP-tNLP+CpG+FSL-1, mice mounted significant humoral and cell-mediated immune responses. Following the i.n. challenge, mice vaccinated with MOMP-tNLP+CpG+FSL-1 i.n. + i.m. group were protected as determined by the percentage change in body weight and by the number of C. muridarum inclusion forming units (IFU) recovered from the lungs. To our knowledge, this is the first time a MOMP-based vaccine formulated in tNLP has been shown to protect against C. muridarum.

60 APPLIED LIFE SCIENCES↗

High-Quality Home Performance: Arizona's Home Performance with ENERGY STAR (R) Program

Arizona Public Service (APS) has created a high-quality Home Performance with ENERGY STAR (ENERGY STAR) program. In addition to being based on the ENERGY STAR guidelines developed by the U.S. Department of Energy and U.S. Environmental Protection Agency, they have used two other national guideline/standards to improve quality and contractor satisfaction: DOE's Standard Work Specifications for Home Energy Upgrades (SWS) and the Home Performance Coalition's Home Performance Extensible Markup Language (HPXML). As the program found areas for improvement, they worked with their implementer FSL Home Energy Solutions (FSL) to develop a quality assurance (QA) program based on the SWS. They also worked with energy assessment and other software providers to implement HPXML in a program administration software platform. This gave contractors a choice in what energy assessment software they used - each tool allowed in the program exported HPXML seamlessly to the program administration platform. APS worked closely with FSL and contractors to implement the QA program and roll out the software improvements. After implementing the QA program and software, the program saw approximately 15% improvement in measure and work scope quality.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PemNet: A Transfer Learning-Based Modeling Approach of High-Temperature Polymer Electrolyte Membrane Electrochemical Systems

Widespread adoption of high-temperature electrochemical systems such as polymer electrolyte membrane fuel cells (HT-PEMFCs) requires models and computational tools for accurate optimization and guiding new materials for enhancing fuel cell performance and durability. Furthermore, while robust and better suited for extrapolation, knowledge-based modeling has limitations as it is time-consuming and requires information about the system that is not always available (e.g., material properties and interfacial behavior between different materials). Data-driven modeling, on the other hand, is easier to implement but often necessitates large datasets that could be difficult to obtain. In this contribution, knowledge-based modeling and data-driven modeling are combined by implementing a few-shot learning (FSL) approach. A knowledge-based model originally developed for a HT-PEMFCs was used to generate simulated data (887,735 points) and used to pretrain a neural network source model tuned via a genetic algorithm-based AutoML. Then, experimental datasets from HT-PEMFCs with different materials and operating conditions (~50 points each) were used to train six target models via FSL. Models for the unseen data reached high accuracies in all cases (rRMSE < 10%).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Online Dynamic Cyber-Attack Diagnosis in Power Electronics Systems Based on Few-Shot Learning

With increasing exposure to software-based sensing and control, power electronics systems are facing higher risks of cyber-physical attacks. To ensure system stability and minimize potential economic losses, it is critical to monitor the operating states and detect those attacks at the early stage. However, anomaly detection and diagnosis of attacks are still challenging, especially when labeled anomaly data is difficult or even infeasible to obtain. To overcome this problem, we propose a Few-Shot Learning (FSL) based approach for cyber-attack diagnosis leveraging the waveform data. To the best of our knowledge, this work is the first attempt at leveraging FSL for cyber-attack diagnosis in power electronics systems. Extensive experimental results demonstrate that our proposed approach can achieve comparable diagnosis accuracy with the state-of-the-art data-driven methods using less than 0.04% of the training samples.

Li, Qi↗

Overall Performance Losses and Activated Mechanisms in Double Glass and Glass-backsheet Photovoltaic Modules with Monofacial and Bifacial PERC Cells, under Accelerated Exposures

Commercial PV modules have various packaging choices nowadays, which influence their long-term reliability. This study compared the degradation behaviors of sixteen module variants from two brands with varying encapsulant materials (EVA or POE), encapsulant types, module architectures (GB or DG), and cell types (monofacial or bifacial) using null hypothesis testing to determine statistical significant findings. The modules were exposed for 2,520 hours under two accelerated exposures: modified damp heat (mDH) and modified damp heat with full-spectrum light (mDH+FSL). For both brands, two DG module variants with UV-Cutoff rear encapsulant are found to have significantly lower average power loss than the module variants of EVA+GB with opaque rear encapsulant after each accelerated exposure. Metallization interconnect corrosion is identified as the primary degradation mechanism. Furthermore, unsupervised hierarchical clustering finds that the degradation behaviors of modules from one brand with a more strict manufacturing quality control depends on module architectures only.

14 SOLAR ENERGY↗

Operating and environmental characteristics of Sigma Tau hydrogen masers used in the Very Long Baseline Array (VLBA)

Presented here are the results obtained from performance evaluation of a pair of Sigma Tau Standards Corporation Model VLBA-112 active hydrogen maser frequency standards. These masers were manufactured for the National Radio Astronomy Observatory (NRAO) for use on the Very Long Baseline Array (VLBA) project and were furnished to the Jet Propulsion Laboratory (JPL) for the purpose of these tests. Tests on the two masers were performed in the JPL Frequency Standards Laboratory (FSL) and included the characterization of output frequency stability versus environmental factors such as temperature, humidity, magnetic field, and barometric pressure. The performance tests also included the determination of phase noise and Allan variance using both FSL and Sigma Tau masers as references. All tests were conducted under controlled laboratory conditions, with only the desired environmental and operational parameters varied to determine sensitivity to external environment.

Tucker, T. K.↗

Differences in Brainstem Fiber Tract Response to Radiation: A Longitudinal Diffusion Tensor Imaging Study

Purpose: To determine whether radiation-induced changes in white matter tracts are uniform across the brainstem. Methods and Materials: We analyzed serial diffusion tensor imaging data, acquired before radiation therapy and over 48 to 72 months of follow-up, from 42 pediatric patients (age 6-20 years) with medulloblastoma. FSL software (FMRIB, Oxford, UK) was used to calculate fractional anisotropy (FA) and axial, radial, and mean diffusivities. For a consistent identification of volumes of interest (VOIs), the parametric maps of each patient were transformed to a standard brain space (MNI152), on which we identified VOIs including corticospinal tract (CST), medial lemniscus (ML), transverse pontine fiber (TPF), and middle cerebellar peduncle (MCP) at the level of pons. Temporal changes of DTI parameters in VOIs were compared using a linear mixed effect model. Results: Radiation-induced white matter injury was marked by a decline in FA after treatment. The decline was often accompanied by decreased axial diffusivity, increased radial diffusivity, or both. This implied axonal damage and demyelination. We observed that the magnitude of the changes was not always uniform across substructures of the brainstem. Specifically, the changes in DTI parameters for TPF were more pronounced than in other regions (P<.001 for FA) despite similarities in the distribution of dose. We did not find a significant difference among CST, ML, and MCP in these patients (P>.093 for all parameters). Conclusions: Changes in the structural integrity of white matter tracts, assessed by DTI, were not uniform across the brainstem after radiation therapy. These results support a role for tract-based assessment in radiation treatment planning and determination of brainstem tolerance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-A-BRF-10: Quantification of Subject-Specific Susceptibility-Related Geometric Distortion in Clinical Liver MRI for Radiation Therapy

Purpose: Subject-specific susceptibility-induced B0 inhomogeneity affects the geometric accuracy of MRI images, with potential impact on the accuracy of treatment planning and image guidance. This study quantifies individual distortions for patients with intrahepatic tumors. Methods: Liver MRI scans of 13 patients who were enrolled in an IRB approved study were acquired on a 3T scanner (Skyra, Siemens). Clinical contrast-enhanced images were acquired by a 3D Volume Interpolated Breath-Hold Examination (VIBE) sequence with TE/TR =1.65/4.3ms, voxel size = 2.5×2.5×3mm (axial sets) or 3.5×3.5×5mm (coronal sets), and frequency-encoding (FE) bandwidth of 440Hz/pixel. B0 inhomogeneity was evaluated by acquisition of dual gradient echoes (GRE) with TE1/TE2/TR =4.92/7.38/106ms, a voxel size of 3.5×3.5×3.75mm, a FE bandwidth of 290Hz/pixel and breath-hold. The phase difference maps from the two echoes were unwrapped using a quantitative MRI analysis software package (FSL, FMRIB, Oxford, UK). The resulting calculated B0 inhomogeneity maps (ΔB0 in Hz) were converted to voxel distortion maps in the FE direction (ΔX in mm) corresponding to the VIBE images. Results: Maximum susceptibility-induced distortions were observed in the liver dome near the diaphragm. Using results from coronal VIBE images in this study as examples, we observed clusters of voxels displaced close to or greater than ΔX=3.5mm (440 Hz in ΔB0) in the VIBE images of the liver in 3 patients, and greater than 2 mm but less than 3.5 mm in 12 patients. On average, approximately 14% of imaged liver voxels had distortions ΔX>±1mm (ΔB0>±125Hz) and 1% of the voxels had ΔX>±2mm (ΔB0>±250Hz). Conclusion: Although advanced MRI techniques, like VIBE, permit faster acquisitions allowing for breath-held examinations with limited motion-induced artifacts, this study suggests that localized distortions due to subject-specific susceptibility variations can occur and require additional advanced corrections based on measuring patient-specific B0 inhomogeneity maps. The authors would like to acknowledge funding support from NIH R01EB016079 and NIH/NCI RO1 CA132834.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP1-15: Towards Accurate Cerebral Blood Flow Quantification with Distortion- Corrected Pseudo-Continuous Arterial Spin Labeling

Purpose: Traditional arterial spin labeling (ASL) acquisitions with echo planar imaging (EPI) readouts suffer from image distortion due to susceptibility effects, compromising ASL’s ability to accurately quantify cerebral blood flow (CBF) and assess disease-specific patterns associated with CBF abnormalities. Phase labeling for additional coordinate encoding (PLACE) can remove image distortion; our goal is to apply PLACE to improve the quantitative accuracy of ASL CBF in humans. Methods: Four subjects were imaged on a 3T Philips Ingenia scanner using a 16-channel receive coil with a 21/21/10cm (frequency/phase/slice direction) field-of-view. An ASL sequence with a pseudo-continuous ASL (pCASL) labeling scheme was employed to acquire thirty dynamics of single-shot EPI data, with control and label datasets for all dynamics, and PLACE gradients applied on odd dynamics. Parameters included a post-labeling delay = 2s, label duration = 1.8s, flip angle = 90°, TR/TE = 5000/23.5ms, and 2.9/2.9/5.0mm (frequency/phase/slice direction) voxel size. “M0” EPI-reference images and T1-weighted spin-echo images with 0.8/1.0/3.3mm (frequency/phase/slice directions) voxel size were also acquired. Complex conjugate image products of pCASL odd and even dynamics were formed, a linear phase ramp applied, and data expanded and smoothed. Data phase was extracted to map control, label, and M0 magnitude image pixels to their undistorted locations, and images were rebinned to original size. All images were corrected for motion artifacts in FSL 5.0. pCASL images were registered to M0 images, and control and label images were subtracted to compute quantitative CBF maps. Results: pCASL image and CBF map distortions were removed by PLACE in all subjects. Corrected images conformed well to the anatomical T1-weighted reference image, and deviations in corrected CBF maps were evident. Conclusion: Eliminating pCASL distortion with PLACE can improve CBF quantification accuracy using minimal pulse sequence modifications and no additional scan time, improving ASL’s clinical applicability.

60 APPLIED LIFE SCIENCES↗

TH-CD-206-01: Expectation-Maximization Algorithm-Based Tissue Mixture Quantification for Perfusion MRI

Purpose: To investigate the feasibility of estimating the tissue mixture perfusions and quantifying cerebral blood flow change in arterial spin labeled (ASL) perfusion MR images. Methods: The proposed perfusion MR image analysis framework consists of 5 steps: (1) Inhomogeneity correction was performed on the T1- and T2-weighted images, which are available for each studied perfusion MR dataset. (2) We used the publicly available FSL toolbox to strip off the non-brain structures from the T1- and T2-weighted MR images. (3) We applied a multi-spectral tissue-mixture segmentation algorithm on both T1- and T2-structural MR images to roughly estimate the fraction of each tissue type - white matter, grey matter and cerebral spinal fluid inside each image voxel. (4) The distributions of the three tissue types or tissue mixture across the structural image array are down-sampled and mapped onto the ASL voxel array via a co-registration operation. (5) The presented 4-dimensional expectation-maximization (4D-EM) algorithm takes the down-sampled three tissue type distributions on perfusion image data to generate the perfusion mean, variance and percentage images for each tissue type of interest. Results: Experimental results on three volunteer datasets demonstrated that the multi-spectral tissue-mixture segmentation algorithm was effective to initialize tissue mixtures from T1- and T2-weighted MR images. Compared with the conventional ASL image processing toolbox, the proposed 4D-EM algorithm not only generated comparable perfusion mean images, but also produced perfusion variance and percentage images, which the ASL toolbox cannot obtain. It is observed that the perfusion contribution percentages may not be the same as the corresponding tissue mixture volume fractions estimated in the structural images. Conclusion: A specific application to brain ASL images showed that the presented perfusion image analysis method is promising for detecting subtle changes in tissue perfusions, which is valuable for the early diagnosis of certain brain diseases, e.g. multiple sclerosis.

60 APPLIED LIFE SCIENCES↗

Optimized 3D co-registration of ultra-low-field and high-field magnetic resonance images

The prototypes of ultra-low-field (ULF) MRI scanners developed in recent years represent new, innovative, cost-effective and safer systems, which are suitable to be integrated in multi-modal (Magnetoencephalography and MRI) devices. Integrated ULF-MRI and MEG scanners could represent an ideal solution to obtain functional (MEG) and anatomical (ULF MRI) information in the same environment, without errors that may limit source reconstruction accuracy. However, the low resolution and signal-to-noise ratio (SNR) of ULF images, as well as their limited coverage, do not generally allow for the construction of an accurate individual volume conductor model suitable for MEG localization. Thus, for practical usage, a high-field (HF) MRI image is also acquired, and the HF-MRI images are co-registered to the ULF-MRI ones. We address here this issue through an optimized pipeline (SWIM—Sliding WIndow grouping supporting Mutual information). The co-registration is performed by an affine transformation, the parameters of which are estimated using Normalized Mutual Information as the cost function, and Adaptive Simulated Annealing as the minimization algorithm. The sub-voxel resolution of the ULF images is handled by a sliding-window approach applying multiple grouping strategies to down-sample HF MRI to the ULF-MRI resolution. The pipeline has been tested on phantom and real data from different ULF-MRI devices, and comparison with well-known toolboxes for fMRI analysis has been performed. Our pipeline always outperformed the fMRI toolboxes (FSL and SPM). The HF–ULF MRI co-registration obtained by means of our pipeline could lead to an effective integration of ULF MRI with MEG, with the aim of improving localization accuracy, but also to help exploit ULF MRI in tumor imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Friction Stir Processing for Efficient Manufacturing

Friction at contacting surfaces in relative motion is a major source of parasitic energy loss in machine systems and manufacturing processes. Consequently, friction reduction usually translates to efficiency gain and reduction in energy consumption. Furthermore, friction at surfaces eventually leads to wear and failure of the components thereby compromising reliability and durability. In order to reduce friction and wear in tribological components, material surfaces are often hardened by a variety of methods, including conventional heat treatment, laser surface hardening, and thin-film coatings. While these surface treatments are effective when used in conjunction with lubrication to prevent failure, they are all energy intensive and could potentially add significant cost. A new concept for surface hardening of metallic materials and components is Friction Stir Processing (FSP). Compared to the current surface hardening technologies, FSP is more energy efficient has no emission or waste by products and may result in better tribological performance. FSP involves plunging a rotating tool to a predetermined depth (case layer thickness) and translating the FSP tool along the area to be processed. This action of the tool produces heating and severe plastic deformation of the processed area. For steel the temperature is high enough to cause phase transformation, ultimately forming hard martensitic phase. Indeed, FSP has been used for surface modification of several metals and alloys so as to homogenize the microstructure and refine the grain size, both of which led to improved fatigue and corrosion resistance. Based on the effect of FSP on near-surface layer material, it was expected to have beneficial effects on friction and wear performance of metallic materials. However, little or no knowledge existed on the impact of FSP concerning friction and wear performance the subject of the this project and final report. Specifically for steel, which is the most dominant tribological material, FSP can replace the current conventional surface hardening techniques used for friction and wear performance. Friction Stir Link Inc. (FSL) is teamed with Argonne National Laboratory (ANL) to develop and optimize FSP for friction and wear performance enhancement. The ultimate goal is to offer FSP and an effective alternative to some of the current energy intensive and high-cost surface hardening processes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Report for SERDP Project RC-1649: Advanced Chemical Measurements of Smoke from DoD-prescribed Burns

Objectives: Project RC-1649, “Advanced Chemical Measurement of Smoke from DoD-prescribed Burns” was undertaken to use advanced instrumental techniques to study in detail the particulate and vapor-phase chemical composition of the smoke that results from prescribed fires used as a land management tool on DoD bases, particularly bases in the southeastern U.S. The statement of need (SON) called for “(1) improving characterization of fuel consumption” and “(2) improving characterization of air emissions under both flaming and smoldering conditions with respect to volatile organic compounds, heavy metals, and reactive gases.” The measurements and fuels were from several bases throughout the southeast (Camp Lejeune, Ft. Benning, and Ft. Jackson) and were carried out in collaboration and conjunction with projects 1647 (models) and 1648 (particulates, SW bases). Technical Approach: We used an approach that featured developing techniques for measuring biomass burning emission species in both the laboratory and field and developing infrared (IR) spectroscopy in particular. Using IR spectroscopy and other methods, we developed emission factors (EF, g of effluent per kg of fuel burned) for dozens of chemical species for several common southeastern fuel types. The major measurement campaigns were laboratory studies at the Missoula Fire Sciences Laboratory (FSL) as well as field campaigns at Camp Lejeune, NC, Ft. Jackson, SC, and in conjunction with 1648 at Vandenberg AFB, and Ft. Huachuca. Comparisons and fusions of laboratory and field data were also carried out, using laboratory fuels from the same bases. Results: The project enabled new technologies and furthered basic science, mostly in the area of infrared spectroscopy, a broadband method well suited to biomass burn studies. Advances in hardware, software and supporting reference data realized a nearly 20x improvement in sensitivity and now provide quantitative IR spectra for potential detection of ~60 new species and actual field quantification of several new species such as nitrous acid, glycolaldehyde, α-/β-pinene and D-limonene. The new reference data also permit calculation of the global warming potential (GWP) of the greenhouse gases by enabling 1) detection of their ambient concentrations, and 2) quantifying their ability to absorb IR radiation.

47 OTHER INSTRUMENTATION↗

Herbaceous Feedstock 2019 State of Technology Report

The U.S. Department of Energy (DOE) promotes the production of advanced liquid transportation fuels from lignocellulosic biomass by funding fundamental and applied research that advances the State of Technology (SOT). As part of its involvement with this mission, Idaho National Laboratory (INL) completes an annual SOT report for biomass feedstock logistics. This report summarizes supply system impacts of Bioenergy Technologies Office (BETO)-funded research and development efforts at INL and elsewhere (such as the High-Tonnage Feedstock Logistics projects (Webb et al. 2013a, Webb et al. 2013b, Webb et al. 2013c, Webb and Sokhansanj 2014, Sokhansanj et al. 2014)) that lead to improvements in feedstock supply systems. These include improvements to and observed performance of innovative harvest and collection methods, storage technologies, transportation and handling approaches, and advanced preprocessing technologies. Biomass quality and variability, and the interface between feedstock quality and conversion performance are key drivers in addition to delivered feedstock cost. In this report, we estimate the benefits of R&D improvements to individual supply system unit operations and present the status of feedstock logistics technology development for converting biomass into biofuels. These analyses are supported by experimental data where possible and help to align the SOT relative to the cost goals defined in the Multi-Year Program Plan. The 2019 Herbaceous SOT incorporates several technology changes in feedstock preprocessing and introduces opportunities from the integrated landscape management (ILM) strategy and increased grower participation to reduce biomass access costs, while maintaining or improving grower profitability. During FY18 uneven flow from the horizontal bale grinder was identified as a significant issue limiting preprocessing system throughput. Based on FSL-funded research at INL, the 2019 Herbaceous SOT replaces the horizontal bale grinder used in the first stage size reduction with a bale processor. The improved uniformity of biomass flow entering the PDU eliminated slugging flow from the first stage size reduction and improved the throughput of downstream operations. In order to achieve moisture reduction through frictional heating during grinding (which allowed elimination of the costly rotary drum dryer in previous SOTs), the second stage grinder was changed from a rotary shear, which does not remove moisture, back to a hammer mill. Finally, the 2019 Herbaceous SOT introduces modified three-pass and two-pass corn stover supply curves derived from the BT16 resource assessment, based on FY19 modeling results (WBS 4.2.1.20) quantifying economic benefits of ILM in the supply area, together with modeling results (WBS 1.2.1.5) identifying ILM strategies to increase grower participation. The 2019 Herbaceous SOT report documents the current modeled cost of an herbaceous feedstock supply system from harvest to the pretreatment reactor throat for hydrocarbon fuel production via biochemical conversion, based on equipment and processes now available or potentially available in the near term. The modeled cost also considers both the required quality and the availability of the biomass resources. The 2019 Herbaceous SOT predicts a modeled delivered feedstock cost of $81.37 /dry ton (2016$); this is a $2.30/dry ton (2016$) decrease from the 2018 Herbaceous SOT. Technology improvements that contributed to this modeled cost reduction include reduced cost for the new preprocessing design and quantification of the opportunities of the integrated landscape management (ILM) strategy and an increased grower participation rate to reduce the grower payment portion of biomass access costs, while maintaining or improving grower profitability. A greenhouse gas emissions (GHG) assessment was completed by Argonne National Laboratory using the 2019 Greenhouse Gases, Regulated Emissions, and Energy use in Transportation model, estimating an increase of 14.89 kg CO2e/ton from the 2018 SOT (69.27 kg CO2e/ton in 2018 to 84.16 kg CO2e/ton in 2019). The increase of energy consumption during preprocessing along with higher transportation distance to access low cost biomass from further distance contributed to the increase of GHG emissions in the 2019 Herbaceous SOT. The reason for the increased transportation distances was the cost tradeoff of going farther from the biorefinery to access the cheaper ILM-derived counties (the cheaper price outweighed the cost of increased supply radius).

09 BIOMASS FUELS↗

Developing a Vaccine Platform for a Balanced Mucosal Immune Response (CB11446), Project Report: Year 1

Mucosal vaccines can elicit protective immune responses at the infection site of respiratory or aerosolized pathogens. Achieving balanced mucosal and systemic responses is a key challenge in the design of mucosal vaccines, especially in terms of developing a broadly applicable vaccine delivery platform amenable to a wide range of subunit vaccine antigens. The overarching goal of the project entitled “Developing a Vaccine Platform for a Balanced Mucosal Immune Response” is to develop a pathogen-agnostic vaccine platform that elicits robust and balanced mucosal immune responses upon intranasal vaccination, in the context of a nanolipoprotein particle (NLP) platform. In year one, we investigated NLP-based vaccine formulations incorporating select immune adjuvants (Monophosphoryl Lipid A (MPLA), FSL-1, L18-muramyl dipeptide (MDP), and cholesterol-tagged ODN2006 (cCpG)) along with antigens relevant to plague (LcrV), tularemia (IglC), and Ebola virus (GP). We demonstrated the ability to prepare, characterize, and quantify these formulations. We then carried out studies in vivo using a BALB/c mouse model, comparing intranasal and intramuscular administration and systematically evaluated the resulting mucosal and systemic immune responses using ELISpot and ELISAs. All proposed tasks (Table 1) were completed within the twelve-month base period, and the established go/no go metric was successfully achieved. Numerous adjuvant:LcrV:NLP formulations were found to have statistically significant increases in IgA titers in serum and/or lung upon IN administration (compared to IM administration), while also producing robust IgG responses in serum. Some formulations also showed significant IFNγ responses using restimulated splenocytes. The data collected during the base period provide valuable insights for the future design of safe and effective mucosal subunit vaccines while also highlighting areas of research that merit further investigation.

59 BASIC BIOLOGICAL SCIENCES↗