Search NASA⌕ Search

SEARCH · Search NASA

Results for “FTMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Easy, Fast, and Reproducible Quantification of Cholesterol and Other Lipids in Human Plasma by Combined High Resolution MSX and FTMS Analysis

Reliable, cost-effective, and gold-standard absolute quantification of non-esterified cholesterol in human plasma is of paramount importance in clinical lipidomics and for the monitoring of metabolic health. Here, we compared the performance of three mass spectrometric approaches available for direct detection and quantification of cholesterol in extracts of human plasma. These approaches are high resolution full scan Fourier transform mass spectrometry (FTMS) analysis, parallel reaction monitoring (PRM), and novel multiplexed MS/MS (MSX) technology, where fragments from selected precursor ions are detected simultaneously. Evaluating the performance of these approaches in terms of dynamic quantification range, linearity, and analytical precision showed that the MSX-based approach is superior to that of the FTMS and PRM-based approaches. To further show the efficacy of this approach, we devised a simple routine for extensive plasma lipidome characterization using only 8 μL of plasma, using a new commercially available ready-to-spike-in mixture with 14 synthetic lipid standards, and executing a single 6 min sample injection with combined MSX analysis for cholesterol quantification and FTMS analysis for quantification of sterol esters, glycerolipids, glycerophospholipids, and sphingolipids. Using this simple routine afforded reproducible and absolute quantification of 200 lipid species encompassing 13 lipid classes in human plasma samples. Notably, the analysis time of this procedure can be shortened for high throughput-oriented clinical lipidomics studies or extended with more advanced MS{sup ALL} technology (Almeida R. et al., J. Am. Soc. Mass Spectrom. 26, 133–148 [1]) to support in-depth structural elucidation of lipid molecules. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Strategies for Obtaining Confident Identifications in Bottom-Up Proteomics Measurements Using Hybrid FTMS instruments

Hybrid FTMS instruments, such as the LTQ-FTTM and LTQ-OrbitrapTM, are capable of generating fast duty cycle linear ion trap MS/MS data along with high resolution information without compromising the overall throughput of measurements. Combined with online LC separations, these instruments represent powerful and flexible tools for proteomics research. In the present work, we explore strategies for high throughput, high coverage proteomics measurements using hybrid FTMS instruments. Our accurate mass and time tag (AMT tag) strategy enables identification of thousands of peptides in a single LC-FTMS analysis by comparing accurate molecular mass and LC elution time information from the analysis to a reference database. An alternative strategy considered here employs linear ion trap (low resolution) MS/MS identifications generated by an appropriate search engine, such as SEQUEST; the high resolution precursor ion spectra were used to refine the MS/MS identifications, an approach termed Accurate Precursor Mass Filter (APMF). The APMF results can be additionally filtered using the LC elution time information from the AMT tag database, which constitutes a Precursor Mass and Time Filter (PMTF), the third approach implemented in this study. Both the APMF and the PMTF approaches are evaluated for coverage and confidence of peptide identifications and contrasted with the current AMT tag strategy. Two separate methodologies were used to reliably quantify identification confidence: a commonly used decoy database method and an alternative method based on the mass accuracy histogram. The two methodologies produced consistent results, confirming the validity of the identification confidence evaluations. Comparison of the three approaches has shown that the AMT tag data analysis approach may be preferential for studies giving a priority to the highest achievable coverage. The APMF approach by itself does not require AMT tag database and provides a moderate coverage combined with acceptable confidence values of ~99%.The PMTF approach yielded a significantly better peptide identification confidence, >99.9%, that essentially excluded any false peptide identifications. The results suggest that even with a perfect peptide ID (0% FDR in the peptide MS/MS database), the peak matching FDR is a function of the database size, so smaller high confidence databases are the goal. Thus a combined strategy can implement multi-pass APMF approach to generate high confidence AMT tag databases, which can be then validated using PMTF approach; the compact high quality databases will be used for subsequent high-throughput, high coverage AMT tag studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Online supercritical fluid extraction mass spectrometry (SFE-LC-FTMS) for sensitive characterization of soil organic matter

We report a novel technical approach for subcritical fluid extraction (SFE) for organic matter characterization in complex matrices such as soil. The custom platform combines on-line SFE with micro-solid phase extraction, nano liquid chromatography (LC), electrospray ionization and Fourier transform mass spectrometry (SFE-LC-FTMS). We demonstrated the utility of SFE-LC-FTMS, including results from both Orbitrap and FTICR MS, for analysis of complex mixtures of organic compounds in a solid matrix by characterizing soil organic matter in peat, a high-carbon soil. For example, in a single experiment, >6000 molecular formulas can be assigned based upon FTICR MS data from 1–50 μL of soil samples (roughly 1–50 mg of soil, dependent on soil density), nearly twice that typically obtained from direct infusion liquid solvent extraction (LSE) from an order of magnitude larger volume of the same soil. The detected species consisted predominately of lipid-like, lignin-like and protein-like compounds, based on their O/C and H/C ratios, with predominantly CHO and CHONP molecular compositions. These results clearly demonstrate that SFE has the potential to effectively extract a variety of molecular species and could become an important member of a suite of extraction methods for studying SOM and other natural organic matter. This is especially true when comprehensive coverage, minimal sample volumes, and high sensitivity are required, or when the presence of organic solvent residue in residual soil is problematic. Lastly, the SFE based extraction protocol could potentially enable spatially resolved characterization of organic matter in soil with a resolution of ~1 mm3 to facilitate studies probing the spatial heterogeneity of soil.

54 ENVIRONMENTAL SCIENCES↗

Computational Prediction of Water Sorption in Facilitated Transport Membranes

Polymeric facilitated transport membranes (FTMs) have emerged as an innovative class of promising carbon capture technology. Studies have shown that the transport properties of an FTM are significantly influenced by its water uptake. In order to better quantify FTM performance, we herein explore the potential of computational techniques to predict the equilibrium water uptake values of FTMs. Two prediction approaches were examined. First, the water sorption was explicitly simulated by iteratively conducting grand canonical Monte Carlo (GCMC) and molecular dynamics (MD) simulations. Second, the water sorption was predicted based on the chemical potential of the adsorbed water, which was calculated using the Widom insertion or continuous fractional component Monte Carlo (CFCMC) method. The chemical potential-based approach with CFCMC demonstrated good prediction of the equilibrium water uptake values of FTMs with poly(N-vinylformamide-co-vinylamine) as fixed-site carrier and 2-(1-piperazinyl)ethylamine sarcosinate as mobile carrier. The predicted water uptake values increased with increasing mobile carrier content and were in good agreement with the experimental values. Furthermore, the higher water uptake promoted the diffusion of CO 2 , N 2 , and mobile carrier as well as slightly stifled the sorption of N 2 . Such an approach significantly contributes to a more comprehensive theoretical evaluation of FTMs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomistic Insights into the Reactive Diffusion of CO 2 in Guanidine-Based Facilitated Transport Membranes

The pressing need to address climate change has led to significant advancements in carbon dioxide (CO 2 ) capture technologies. Notably, facilitated transport membranes (FTMs) are distinguished by their exceptional selectivity and permeance, attributed to their reversible chemical reactions with CO 2 . This study, for the first time, sheds light on the reactive diffusion mechanism of CO 2 in FTMs, utilizing 1,1,3,3-tetramethylguanidine (TMG) as a mobile carrier. Specifically, state-ofthe- art molecular dynamics (MD) simulations, augmented by a reparameterized reactive force field (ReaxFF) capable of describing atomistic interactions and reaction pathways, are conducted to investigate the transport of CO 2 in TMG. The analysis of mean squared displacement (MSD) and diffusion coefficients reveals a clear hierarchy in the mobility of reaction components. Our findings highlight a unique hopping diffusion mechanism between bicarbonate ions and TMG molecules, increasing the diffusivity of reacted CO 2 by 1.4 times. The hopping events observed not only enhance our understanding of molecular mobility but also offer a means to boost the performance of FTMs in CO 2 capture applications. Overall, this research lays the groundwork for the future design of FTMs with optimal carrier properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reviews and syntheses: Opportunities for robust use of peak intensities from high-resolution mass spectrometry in organic matter studies

Abstract. Earth's biogeochemical cycles are intimately tied to the biotic and abiotic processing of organic matter (OM). Spatial and temporal variations in OM chemistry are often studied using direct infusion, high-resolution Fourier transform mass spectrometry (FTMS). An increasingly common approach is to use ecological metrics (e.g., within-sample diversity) to summarize high-dimensional FTMS data, notably Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS). However, problems can arise when FTMS peak-intensity data are used in a way that is analogous to abundances in ecological analyses (e.g., species abundance distributions). Using peak-intensity data in this way requires the assumption that intensities act as direct proxies for concentrations. Here, we show that comparisons of the same peak across samples (within-peak) may carry information regarding variations in relative concentration, but comparing different peaks (between-peak) within or between samples does not. We further developed a simulation model to study the quantitative implications of using peak intensities to compute ecological metrics (e.g., intensity-weighted mean properties and diversity) that rely on information about both within-peak and between-peak shifts in relative abundance. We found that, despite analytical limitations in linking concentration to intensity, ecological metrics often perform well in terms of providing robust qualitative inferences and sometimes quantitatively accurate estimates of diversity and mean molecular characteristics. We conclude with recommendations for the robust use of peak intensities for natural organic matter studies. A primary recommendation is the use and extension of the simulation model to provide objective guidance on the degree to which conceptual and quantitative inferences can be made for a given analysis of a given dataset. Broad use of this approach can help ensure rigorous scientific outcomes from the use of FTMS peak intensities in environmental applications.

54 ENVIRONMENTAL SCIENCES↗

Silver-mediated separations: A comprehensive review on advancements of argentation chromatography, facilitated transport membranes, and solid-phase extraction techniques and their applications

The use of silver(I) ions in chemical separations, also known as argentation separations, is a powerful approach for the selective separation and analysis of many natural and synthetic organic compounds. In this review, a comprehensive discussion of the most common argentation separation techniques, including argentation-liquid chromatography (Ag-LC), argentation-gas chromatography (Ag-GC), argentation-facilitated transport membranes (Ag-FTMs), and argentation-solid phase extraction (Ag-SPE) is provided. For each of these techniques, notable advancements, optimized separations, and innovative applications are discussed. The review begins with an explanation of the fundamental chemistry underlying argentation separations, mainly the reversible π-complexation between silver(I) ions and carbon-carbon double bonds. Within Ag-LC, the use of silver(I) ions in thin-layer chromatography, high-performance liquid chromatography, as well as preparative LC are explored. This discussion focuses on how silver(I) ions are employed in the stationary and mobile phase to separate unsaturated compounds. For Ag-GC and Ag-FTMs, different silver compounds and supporting media are discussed, often with relation to olefin-paraffin separations. Ag-SPE has been widely employed for the selective extraction of unsaturated compounds from complex matrices in sample preparation. This comprehensive review of Ag-LC, Ag-GC, Ag-FTMs, and Ag-SPE techniques emphasizes the immense potential of argentation separations in separations science and serves as a valuable resource for researchers seeking to learn, optimize, and utilize argentation separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Facilitated transport membranes for H 2 purification from coal-derived syngas: A techno-economic analysis

A single-stage membrane process has been designed for using facilitated transport membranes (FTMs) to decarbonize the coal-derived syngas from an integrated gasification combined cycle (IGCC) power plant. The necessary process model and costing method have also been developed to assess the technical feasibility and process economics. In order to account for the carrier saturation phenomenon associated with FTMs, a homogeneous reactive diffusion model is integrated into the process model. The techno-economic study reveals that the mitigated carrier saturation upon bulk CO 2 removal can lead to appreciable increases in the CO 2 permeance and CO 2 /H 2 selectivity, which can be utilized to achieve 95% CO 2 purity and 95% H 2 recovery with a CO 2 /H 2 selectivity of 50 at the complete carrier saturation. FTMs with different facilitated transport characteristics can also be arranged in a hybrid membrane configuration to render a H 2 recovery of 99% and a cost of electricity of $\$118.5$ /MWh, which is 12.5% lower than that of the benchmark Selexol process.

42 ENGINEERING↗

13 C NMR study of amino acid salts in facilitated transport membranes for post-combustion carbon capture

Some of amino acid salts (AASs) have been demonstrated to be effective mobile carriers in facilitated transport membranes (FTMs) to achieve superior CO 2 permeance and CO 2 /N 2 selectivity for CO 2 capture from flue gas. Understandings of how the structures of different AASs affect the chemistry of the amine–CO 2 reaction are essential for the future development of more efficient AAS mobile carriers. In this study, the reaction chemistry of selected AASs with CO 2 was investigated by 13 C nuclear magnetic resonance (NMR) spectroscopy. The CO 2 loading and the distribution of major reaction products, including carbamate and bicarbonate products of each studied AAS were quantitatively analyzed. The positive correlation between the CO 2 loading of AAS (mol CO 2 /g AAS) and the CO 2 permeance of FTMs suggested that AAS with a higher CO 2 loading may improve the performance of FTMs. Our results also showed that increasing the steric hindrance of AAS could be a practical way to promote the bicarbonate reaction pathway and thus potentially increase the CO 2 loading (mol CO 2 /mol AAS). Moreover, 2-(1-piperazinyl)ethylamine (PZEA) was found to be a more effective multi-amine than piperazine (PZ) for synthesizing AASs due to the presence of more effective nitrogen sites per molecule. The superior CO 2 permeance of the PZEA-Sar membrane is also attributed to its more uniform membrane formation. As a result, the knowledge gained from this study will inform the rational design of more effective AAS carriers for CO 2 capture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computational Evaluation of Carriers in Facilitated Transport Membranes for Postcombustion Carbon Capture

Incorporating molecular amines as mobile carriers in facilitated transport membranes (FTMs) has been demonstrated to significantly enhance the CO 2 permeance and CO 2 /N 2 selectivity of the membrane for CO 2 capture from flue gas. In this study, by employing computational techniques including density functional theory calculations and molecular simulations, the role of mobile carriers has been systematically studied at a molecular level from the perspectives of the amine–CO 2 reaction chemistry, diffusivities of carriers and gases, and N 2 solubility. The latter two properties were also investigated as a function of water uptake. The water uptake values of FTMs were experimentally quantified too. The introduction of mobile carriers was shown to substantially enhance the diffusivities of CO 2 reaction products compared to FTMs without mobile carriers. The choice of mobile carriers was also demonstrated to influence the separation performance. Computationally, 2-(1-piperazinyl)ethylamine sarcosinate (PZEA-Sar) exhibited a faster reaction kinetics and slightly higher CO 2 absorption capacity as compared to piperazine glycinate (PZ-Gly). Experimentally, the FTM incorporating PZEA-Sar mobile carriers also showed a higher CO 2 permeance. The good agreement validated the computational models employed and insights generated in this study. In conclusion, the outcomes of this work shed light on the future design and selection of carrier structures, and the adopted computational approaches can be employed to discover promising mobile carrier candidates.

20 FOSSIL-FUELED POWER PLANTS↗

Foundations of Molecular 'Isotomics'

The naturally occurring rare isotopes are versions of common elements, such as hydrogen, carbon and oxygen, that contain a larger than usual number of neutrons in their atomic nuclei and therefore are higher in mass than the common atoms of that element. Isotopes exist for most elements and are found in most natural and synthetic materials, but are uneven in their distribution because chemical and physical processes are isotope-selective (e.g., a chemical reaction may proceed more rapidly for one isotope than for another). For this reason, abundances of isotopes in a material of interest can provide a record, or ‘signature’ of various features of that material’s origin and history. These signatures have been used in the geo, life, chemical and physical sciences in a wide variety of ways over close to 8 decades. However, many such applications struggle to reach unique interpretations of isotopic data because multiple factors combine to control a given sample’s overall isotopic content. That is, the factors controlling isotopic content are too numerous and complex to fully constrain from a simple measurement of a material’s isotope abundances. However, the distribution of isotopes within materials, at molecular scales potentially provides a vastly larger number and diversity of constraints on the chemical and physical processes that comprise a material’s history. The rare isotopes may be concentrated into one atomic position in a molecule relative to another, some proportion of molecules in a sample may contain two or more rare isotopes, and those multiply-isotope-substituted forms of molecules may also have uneven distributions of those isotopes across individual atomic sites. For these reasons, even small, seemingly simple molecules, such as sugars, amino acids or drug compounds, actually exist in a vast number of isotopically unique forms (often millions or more), and each one of those forms is in some sense an independent ‘vote’ on that sample’s history. This project has focused on opening this rich archive of information by enabling the creation of routinely and widely applicable ways of measuring and interpreting isotopic structures of molecules. This work has included the development of core technologies and analytical methods, advancing fundamental understanding of the physical and chemical properties of isotopic versions of molecules, and conducting proof of concept studies of illustrative geochemical, cosmochemical and forensic problems in order to show how these technologies, methods and principles come together to solve problems in new ways. A key to the success of this project was the adaptation of ‘Fourier transform mass spectrometry’ (FTMS) to the task of precisely measuring proportions of the rare, naturally occurring isotopic forms of molecules. FTMS is a highly specialized form of mass spectrometry that traps ions within magnetic or electrostatic cavities and, effectively, ‘listens’ (through registering of subtle electrical signals) to the harmonic signals they make while rapidly orbiting within those cavities. These signals have periods that are a function of their mass and strength (or ‘loudness’) that is proportional to their abundances. Thus, these signals constrain relative amounts of molecules that differ in their mass due to various isotopic substitutions. This technology has been essential to the identification of organic molecules in the life, chemical and environmental sciences for over 4 decades, but generally has lacked the control, stability and precision to meaningfully measure rare isotope forms of molecules. This project’s most fundamental contribution has been to modify FTMS, both in terms of hardware and methods, to enable such measurements. The raw data of molecular isotopic structure is tremendously voluminous and complex, so another important activity of this project has been developing the theoretical and data-science tools needed to interpret the data generated by this new form of isotopic measurement. A particularly challenging part of this task has been predicting molecular isotopic structure, as only through the comparison of measurements with predictions can we make progress on hypothesis driven research questions. We have attacked this this prediction task through a combination of first-principles chemical-physics models of the effects of isotope substitution on molecule properties and data-science models that permit us to generalize that chemical physics to cases that have not yet been studied by detailed chemical physics theory. The proof of concept applications we have pursued over the course of this study include biological reactions of amino acids and other biomolecules, non-biological synthesis of organic molecules in extra-terrestrial settings such as meteorites, petroleum geoscience questions concerning the origin and evolution of natural gas, oil and kerogen compounds, and forensic questions such as the sourcing of chemical weapons. The successes of these applications have laid the groundwork for the next phase of this field’s development, which will include larger scale and more ambitious studies of molecular isotopic structure as a means of diagnosing human diseases, such as cancer, and reconstructing detailed interpretations of the origin and evolution of organic molecules in modern and geological environments.

Cesar, Jaime↗

Utilization of the LS-APGD microplasma/orbitrap-FTMS booster system for detection and isotopic analysis of neodymium nanoparticles

Detection and isotopic analysis of particle populations has seen rapid growth across several application areas, including environmental analysis, nuclear forensics, and food safety. The ability to characterize the particles' unique elemental and isotopic fingerprints could provide information related to formation, processing history, and transport. Regarding nuclear forensics, isotopic analysis of particles derived from diverse materials is often used as a tool to trace the origin and processing history. Mass spectrometric-based techniques currently used for particle population analysis often suffer from limited mass resolution, particularly when dealing with real-world samples that are affected by isobaric and polyatomic interferences from the matrix. To address these analytical challenges, we propose a novel method utilizing the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an ultrahigh resolution Orbitrap mass spectrometer, further enhanced with the FTMS X2T Booster data acquisition and processing unit. The FTMS Booster enables acquisition of extended transient times of up to 3 s, significantly improving mass resolution, thereby reducing or even eliminating the need for prior separation of isobaric or polyatomic interferences. Additionally, the detection of low-abundance isotopes was improved by increasing the signal-to-noise (S/N) ratio. As proof of concept, this study demonstrates the feasibility of the LS-APGD/Orbitrap-FTMS X2T Booster platform for direct analysis using a suspension of well-characterized ∼120 nm neodymium particles. The quality of the isotope ratios values obtained from a few hundred particles were in good agreement with those obtained from homogeneous ionic solutions. These results highlight the potential of the LS-APGD/Orbitrap platform for rapid, accurate, and interference-resilient isotope ratio analysis of particle populations without the need for dissolution and subsequent chemical separations, offering significant advantages for nuclear forensics, safeguards, and environmental applications. The effort here also points to further paths forward, hopefully towards single particle (SP) analysis using microplasma ionization and the ultrahigh resolving power of the Orbitrap mass analyzer.

FTMS X2T booster↗

An integrated top-down and bottom-up proteomic approach to characterize the antigen binding fragment of antibodies

We have previously shown that different individuals exposed to the same antigen produce antibodies with identical mutations in their complementarity determining regions (CDR), suggesting that CDR tryptic peptides can serve as biomarkers for disease diagnosis and prognosis. Complete Fabs derived from disease specific antibodies have even higher potential; they could potentially be used for disease treatment and are required to identify the antigens towards which the antibodies are directed. However, complete Fab sequence characterization via LC-MS analysis of tryptic peptides (i.e. bottom-up) has proven to be impractical for mixtures of antibodies. To tackle this challenge, we have developed an integrated bottom-up and top-down MS approach, employing 2D chromatography coupled with Fourier transform mass spectrometry (FTMS), and applied this approach for full characterization of the variable parts of two pharmaceutical monoclonal antibodies with sensitivity comparable to the bottom-up standard. These efforts represent an essential step towards the identification of disease specific antibodies in patient samples with potentially significant clinical impact.

Antibodies↗

Complete resolution across the neodymium/samarium isotopic envelope with a liquid sampling‐atmospheric pressure glow discharge — Orbitrap mass spectrometer

Rationale Nd and Sm isotope ratios play an important role in geological dating and as nuclear forensic signatures; however, the overlap of the respective 144, 148, 150 Nd/Sm isobars requires prior separations to be performed before analysis on typical MS platforms. The work presented here overcomes these isobaric interferences using ultrahigh‐mass resolution to alleviate interference without prior chemical separations. Methods A liquid sampling‐atmospheric pressure glow discharge ion source was coupled to a standard, QExactive Focus Orbitrap mass spectrometer, providing a mass resolution of ~80 k. A Spectroswiss FTMS booster X2 data acquisition package was used to collect extended transients, providing much higher mass resolution; ~230 k and ~600 k are employed here for Nd and Sm isotopes. Results While the standard Orbitrap resolution is far greater than typical “atomic” MS platforms, it was insufficient to alleviate all isobars. The use of a resolution of ~230 k resulted in baseline separation across the entire isotopic envelope for both Nd and Sm. Isotope ratios obtained from Nd:Sm mixtures using high‐resolution were equivalent to those found for individual‐element solutions, while isotope ratios obtained at a resolution of ~80 k (standard for the OEM data system) showed large deviations. Conclusions Use of ultrahigh‐resolution is an attractive alternative to extensive chemical separations to alleviate severe isobaric interferences. Sufficient mass resolution greatly reduces/eliminates the need for sample manipulations (separations) before analysis while reducing costs and total analysis times.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup↗

Front-End Electron Transfer Dissociation Coupled to a 21 Tesla FT-ICR Mass Spectrometer for Intact Protein Sequence Analysis

High resolution mass spectrometry is a key technology for in-depth protein characterization. High-field Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) enables high-level interrogation of intact proteins in the most detail to date. However, an appropriate complement of fragmentation technologies must be paired with FTMS to provide comprehensive sequence coverage, as well as characterization of sequence variants, and post-translational modifications. Here we describe the integration of front-end electron transfer dissociation (FETD) with a custom-built 21 tesla FT-ICR mass spectrometer, which yields unprecedented sequence coverage for proteins ranging from 2.8 to 29 kDa, without the need for extensive spectral averaging (e.g., ~60% sequence coverage for apo-myoglobin with four averaged acquisitions). The system is equipped with a multipole storage device separate from the ETD reaction device, which allows accumulation of multiple ETD fragment ion fills. Consequently, an optimally large product ion population is accumulated prior to transfer to the ICR cell for mass analysis, which improves mass spectral signal-to-noise ratio, dynamic range, and scan rate. We find a linear relationship between protein molecular weight and minimum number of ETD reaction fills to achieve optimum sequence coverage, thereby enabling more efficient use of instrument data acquisition time. Finally, real-time scaling of the number of ETD reactions fills during method-based acquisition is shown, and the implications for LC-MS/MS top-down analysis are discussed. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-selective membrane composed of charge-stabilized fixed carrier and amino acid-based ionic liquid mobile carrier for highly efficient carbon capture

Membrane technology has been extensively studied for CO 2 capture applications, especially for flue gas sources. In the past decades, facilitated transport membranes (FTMs) have made breakthroughs overcoming the permeance-selectivity trade-off upper bound restricting traditional CO 2 separation membranes, but are still facing challenges towards practical applications, including limited performance, such as insufficient CO 2 /N 2 selectivity to achieve 95 % CO 2 dry-base purity by one step separation, and long-term stability. Herein, we designed and fabricated a novel FTM structure containing an ionic liquid (1-ethyl-3-methylimidazolium aminoacetate, [Emim][Gly]) as mobile CO 2 -carrier and a polymeric amine (polyethyleneimine, PEI) as fixed CO 2 -carrier. In this study, the fixed carrier is confined within a carbon nanotube (CNT) framework of 230 nm thickness via electrostatic forces adjusted by a polyelectrolyte (polystyrene sulfonate, PSS), while the mobile carrier diffuses freely within the CNT framework. After optimization of the membrane recipe and spray-coating fabrication procedure, following our previous work, the resulting CNT-PSS-PEI ~ IL membranes demonstrated an ultra-high CO 2 /N 2 selectivity up to 1,000 with CO 2 permeance up to 2,400 GPU (Gas Permeation Unit, 1 GPU = 3.348 × 10 -10 mol·s -1 ·m -2 ·Pa -1 ) under vacuum operation condition. Furthermore, one 100-cm 2 flat sheet membrane sample was prepared and exhibited one-stage CO 2 enrichment from 15 % to 95 % purity (dry-base) for the first time amongst all reported CO 2 separation membranes. The membrane retained a stable performance over 50-h operation period under vacuum condition. The extraordinary CO 2 separation performance illustrates the great potential of the CNT-PSS-PEI ~ IL membranes for flue gas carbon capture application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

FT-ICR MS optimization for the analysis of intact proteins

Fourier-transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS) remains the technique of choice for the analysis of intact proteins from complex biological systems, i.e. top-down proteomics. Recently, we have implemented a compensated open cylindrical ion trapping cell into a 12 T FT-ICR mass spectrometer. This new cell has previously demonstrated improved sensitivity, dynamic range, and mass measurement accuracy for the analysis of relatively small tryptic peptides. These improvements are due to the improved trapping potential of the cell which is significantly closer to the ideal harmonic trapping potential. Here we report the instrument optimization for the analysis of large macro-molecular ions, such as proteins. Also, presented are first principle theoretical considerations to account for different optimum conditions for the analysis of large macro-molecules. The proposed high energy ion loss mechanism is further supported by experimental results of bovine ubiquitin and serum albumin. We find that the analysis of large macro-molecules can be significantly improved by the further reduction of pressure in the ion trapping cell. This will reduce the impact of the high energy ion loss mechanism and enable increased sensitivity and mass measurement accuracy to be realized without compromising resolution. Further, these results appear to be applicable to FTMS in general, and the high energy ion loss mechanism applies to Orbitrap mass analyzers as well.

59 BASIC BIOLOGICAL SCIENCES↗