Search NASA⌕ Search

SEARCH · Search NASA

Results for “FTMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Computational Prediction of Water Sorption in Facilitated Transport Membranes

Polymeric facilitated transport membranes (FTMs) have emerged as an innovative class of promising carbon capture technology. Studies have shown that the transport properties of an FTM are significantly influenced by its water uptake. In order to better quantify FTM performance, we herein explore the potential of computational techniques to predict the equilibrium water uptake values of FTMs. Two prediction approaches were examined. First, the water sorption was explicitly simulated by iteratively conducting grand canonical Monte Carlo (GCMC) and molecular dynamics (MD) simulations. Second, the water sorption was predicted based on the chemical potential of the adsorbed water, which was calculated using the Widom insertion or continuous fractional component Monte Carlo (CFCMC) method. The chemical potential-based approach with CFCMC demonstrated good prediction of the equilibrium water uptake values of FTMs with poly(N-vinylformamide-co-vinylamine) as fixed-site carrier and 2-(1-piperazinyl)ethylamine sarcosinate as mobile carrier. The predicted water uptake values increased with increasing mobile carrier content and were in good agreement with the experimental values. Furthermore, the higher water uptake promoted the diffusion of CO 2 , N 2 , and mobile carrier as well as slightly stifled the sorption of N 2 . Such an approach significantly contributes to a more comprehensive theoretical evaluation of FTMs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomistic Insights into the Reactive Diffusion of CO 2 in Guanidine-Based Facilitated Transport Membranes

The pressing need to address climate change has led to significant advancements in carbon dioxide (CO 2 ) capture technologies. Notably, facilitated transport membranes (FTMs) are distinguished by their exceptional selectivity and permeance, attributed to their reversible chemical reactions with CO 2 . This study, for the first time, sheds light on the reactive diffusion mechanism of CO 2 in FTMs, utilizing 1,1,3,3-tetramethylguanidine (TMG) as a mobile carrier. Specifically, state-ofthe- art molecular dynamics (MD) simulations, augmented by a reparameterized reactive force field (ReaxFF) capable of describing atomistic interactions and reaction pathways, are conducted to investigate the transport of CO 2 in TMG. The analysis of mean squared displacement (MSD) and diffusion coefficients reveals a clear hierarchy in the mobility of reaction components. Our findings highlight a unique hopping diffusion mechanism between bicarbonate ions and TMG molecules, increasing the diffusivity of reacted CO 2 by 1.4 times. The hopping events observed not only enhance our understanding of molecular mobility but also offer a means to boost the performance of FTMs in CO 2 capture applications. Overall, this research lays the groundwork for the future design of FTMs with optimal carrier properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reviews and syntheses: Opportunities for robust use of peak intensities from high-resolution mass spectrometry in organic matter studies

Abstract. Earth's biogeochemical cycles are intimately tied to the biotic and abiotic processing of organic matter (OM). Spatial and temporal variations in OM chemistry are often studied using direct infusion, high-resolution Fourier transform mass spectrometry (FTMS). An increasingly common approach is to use ecological metrics (e.g., within-sample diversity) to summarize high-dimensional FTMS data, notably Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS). However, problems can arise when FTMS peak-intensity data are used in a way that is analogous to abundances in ecological analyses (e.g., species abundance distributions). Using peak-intensity data in this way requires the assumption that intensities act as direct proxies for concentrations. Here, we show that comparisons of the same peak across samples (within-peak) may carry information regarding variations in relative concentration, but comparing different peaks (between-peak) within or between samples does not. We further developed a simulation model to study the quantitative implications of using peak intensities to compute ecological metrics (e.g., intensity-weighted mean properties and diversity) that rely on information about both within-peak and between-peak shifts in relative abundance. We found that, despite analytical limitations in linking concentration to intensity, ecological metrics often perform well in terms of providing robust qualitative inferences and sometimes quantitatively accurate estimates of diversity and mean molecular characteristics. We conclude with recommendations for the robust use of peak intensities for natural organic matter studies. A primary recommendation is the use and extension of the simulation model to provide objective guidance on the degree to which conceptual and quantitative inferences can be made for a given analysis of a given dataset. Broad use of this approach can help ensure rigorous scientific outcomes from the use of FTMS peak intensities in environmental applications.

54 ENVIRONMENTAL SCIENCES↗

Silver-mediated separations: A comprehensive review on advancements of argentation chromatography, facilitated transport membranes, and solid-phase extraction techniques and their applications

The use of silver(I) ions in chemical separations, also known as argentation separations, is a powerful approach for the selective separation and analysis of many natural and synthetic organic compounds. In this review, a comprehensive discussion of the most common argentation separation techniques, including argentation-liquid chromatography (Ag-LC), argentation-gas chromatography (Ag-GC), argentation-facilitated transport membranes (Ag-FTMs), and argentation-solid phase extraction (Ag-SPE) is provided. For each of these techniques, notable advancements, optimized separations, and innovative applications are discussed. The review begins with an explanation of the fundamental chemistry underlying argentation separations, mainly the reversible π-complexation between silver(I) ions and carbon-carbon double bonds. Within Ag-LC, the use of silver(I) ions in thin-layer chromatography, high-performance liquid chromatography, as well as preparative LC are explored. This discussion focuses on how silver(I) ions are employed in the stationary and mobile phase to separate unsaturated compounds. For Ag-GC and Ag-FTMs, different silver compounds and supporting media are discussed, often with relation to olefin-paraffin separations. Ag-SPE has been widely employed for the selective extraction of unsaturated compounds from complex matrices in sample preparation. This comprehensive review of Ag-LC, Ag-GC, Ag-FTMs, and Ag-SPE techniques emphasizes the immense potential of argentation separations in separations science and serves as a valuable resource for researchers seeking to learn, optimize, and utilize argentation separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Facilitated transport membranes for H 2 purification from coal-derived syngas: A techno-economic analysis

A single-stage membrane process has been designed for using facilitated transport membranes (FTMs) to decarbonize the coal-derived syngas from an integrated gasification combined cycle (IGCC) power plant. The necessary process model and costing method have also been developed to assess the technical feasibility and process economics. In order to account for the carrier saturation phenomenon associated with FTMs, a homogeneous reactive diffusion model is integrated into the process model. The techno-economic study reveals that the mitigated carrier saturation upon bulk CO 2 removal can lead to appreciable increases in the CO 2 permeance and CO 2 /H 2 selectivity, which can be utilized to achieve 95% CO 2 purity and 95% H 2 recovery with a CO 2 /H 2 selectivity of 50 at the complete carrier saturation. FTMs with different facilitated transport characteristics can also be arranged in a hybrid membrane configuration to render a H 2 recovery of 99% and a cost of electricity of $\$118.5$ /MWh, which is 12.5% lower than that of the benchmark Selexol process.

42 ENGINEERING↗

13 C NMR study of amino acid salts in facilitated transport membranes for post-combustion carbon capture

Some of amino acid salts (AASs) have been demonstrated to be effective mobile carriers in facilitated transport membranes (FTMs) to achieve superior CO 2 permeance and CO 2 /N 2 selectivity for CO 2 capture from flue gas. Understandings of how the structures of different AASs affect the chemistry of the amine–CO 2 reaction are essential for the future development of more efficient AAS mobile carriers. In this study, the reaction chemistry of selected AASs with CO 2 was investigated by 13 C nuclear magnetic resonance (NMR) spectroscopy. The CO 2 loading and the distribution of major reaction products, including carbamate and bicarbonate products of each studied AAS were quantitatively analyzed. The positive correlation between the CO 2 loading of AAS (mol CO 2 /g AAS) and the CO 2 permeance of FTMs suggested that AAS with a higher CO 2 loading may improve the performance of FTMs. Our results also showed that increasing the steric hindrance of AAS could be a practical way to promote the bicarbonate reaction pathway and thus potentially increase the CO 2 loading (mol CO 2 /mol AAS). Moreover, 2-(1-piperazinyl)ethylamine (PZEA) was found to be a more effective multi-amine than piperazine (PZ) for synthesizing AASs due to the presence of more effective nitrogen sites per molecule. The superior CO 2 permeance of the PZEA-Sar membrane is also attributed to its more uniform membrane formation. As a result, the knowledge gained from this study will inform the rational design of more effective AAS carriers for CO 2 capture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computational Evaluation of Carriers in Facilitated Transport Membranes for Postcombustion Carbon Capture

Incorporating molecular amines as mobile carriers in facilitated transport membranes (FTMs) has been demonstrated to significantly enhance the CO 2 permeance and CO 2 /N 2 selectivity of the membrane for CO 2 capture from flue gas. In this study, by employing computational techniques including density functional theory calculations and molecular simulations, the role of mobile carriers has been systematically studied at a molecular level from the perspectives of the amine–CO 2 reaction chemistry, diffusivities of carriers and gases, and N 2 solubility. The latter two properties were also investigated as a function of water uptake. The water uptake values of FTMs were experimentally quantified too. The introduction of mobile carriers was shown to substantially enhance the diffusivities of CO 2 reaction products compared to FTMs without mobile carriers. The choice of mobile carriers was also demonstrated to influence the separation performance. Computationally, 2-(1-piperazinyl)ethylamine sarcosinate (PZEA-Sar) exhibited a faster reaction kinetics and slightly higher CO 2 absorption capacity as compared to piperazine glycinate (PZ-Gly). Experimentally, the FTM incorporating PZEA-Sar mobile carriers also showed a higher CO 2 permeance. The good agreement validated the computational models employed and insights generated in this study. In conclusion, the outcomes of this work shed light on the future design and selection of carrier structures, and the adopted computational approaches can be employed to discover promising mobile carrier candidates.

20 FOSSIL-FUELED POWER PLANTS↗

Foundations of Molecular 'Isotomics'

The naturally occurring rare isotopes are versions of common elements, such as hydrogen, carbon and oxygen, that contain a larger than usual number of neutrons in their atomic nuclei and therefore are higher in mass than the common atoms of that element. Isotopes exist for most elements and are found in most natural and synthetic materials, but are uneven in their distribution because chemical and physical processes are isotope-selective (e.g., a chemical reaction may proceed more rapidly for one isotope than for another). For this reason, abundances of isotopes in a material of interest can provide a record, or ‘signature’ of various features of that material’s origin and history. These signatures have been used in the geo, life, chemical and physical sciences in a wide variety of ways over close to 8 decades. However, many such applications struggle to reach unique interpretations of isotopic data because multiple factors combine to control a given sample’s overall isotopic content. That is, the factors controlling isotopic content are too numerous and complex to fully constrain from a simple measurement of a material’s isotope abundances. However, the distribution of isotopes within materials, at molecular scales potentially provides a vastly larger number and diversity of constraints on the chemical and physical processes that comprise a material’s history. The rare isotopes may be concentrated into one atomic position in a molecule relative to another, some proportion of molecules in a sample may contain two or more rare isotopes, and those multiply-isotope-substituted forms of molecules may also have uneven distributions of those isotopes across individual atomic sites. For these reasons, even small, seemingly simple molecules, such as sugars, amino acids or drug compounds, actually exist in a vast number of isotopically unique forms (often millions or more), and each one of those forms is in some sense an independent ‘vote’ on that sample’s history. This project has focused on opening this rich archive of information by enabling the creation of routinely and widely applicable ways of measuring and interpreting isotopic structures of molecules. This work has included the development of core technologies and analytical methods, advancing fundamental understanding of the physical and chemical properties of isotopic versions of molecules, and conducting proof of concept studies of illustrative geochemical, cosmochemical and forensic problems in order to show how these technologies, methods and principles come together to solve problems in new ways. A key to the success of this project was the adaptation of ‘Fourier transform mass spectrometry’ (FTMS) to the task of precisely measuring proportions of the rare, naturally occurring isotopic forms of molecules. FTMS is a highly specialized form of mass spectrometry that traps ions within magnetic or electrostatic cavities and, effectively, ‘listens’ (through registering of subtle electrical signals) to the harmonic signals they make while rapidly orbiting within those cavities. These signals have periods that are a function of their mass and strength (or ‘loudness’) that is proportional to their abundances. Thus, these signals constrain relative amounts of molecules that differ in their mass due to various isotopic substitutions. This technology has been essential to the identification of organic molecules in the life, chemical and environmental sciences for over 4 decades, but generally has lacked the control, stability and precision to meaningfully measure rare isotope forms of molecules. This project’s most fundamental contribution has been to modify FTMS, both in terms of hardware and methods, to enable such measurements. The raw data of molecular isotopic structure is tremendously voluminous and complex, so another important activity of this project has been developing the theoretical and data-science tools needed to interpret the data generated by this new form of isotopic measurement. A particularly challenging part of this task has been predicting molecular isotopic structure, as only through the comparison of measurements with predictions can we make progress on hypothesis driven research questions. We have attacked this this prediction task through a combination of first-principles chemical-physics models of the effects of isotope substitution on molecule properties and data-science models that permit us to generalize that chemical physics to cases that have not yet been studied by detailed chemical physics theory. The proof of concept applications we have pursued over the course of this study include biological reactions of amino acids and other biomolecules, non-biological synthesis of organic molecules in extra-terrestrial settings such as meteorites, petroleum geoscience questions concerning the origin and evolution of natural gas, oil and kerogen compounds, and forensic questions such as the sourcing of chemical weapons. The successes of these applications have laid the groundwork for the next phase of this field’s development, which will include larger scale and more ambitious studies of molecular isotopic structure as a means of diagnosing human diseases, such as cancer, and reconstructing detailed interpretations of the origin and evolution of organic molecules in modern and geological environments.

Cesar, Jaime↗

Utilization of the LS-APGD microplasma/orbitrap-FTMS booster system for detection and isotopic analysis of neodymium nanoparticles

Detection and isotopic analysis of particle populations has seen rapid growth across several application areas, including environmental analysis, nuclear forensics, and food safety. The ability to characterize the particles' unique elemental and isotopic fingerprints could provide information related to formation, processing history, and transport. Regarding nuclear forensics, isotopic analysis of particles derived from diverse materials is often used as a tool to trace the origin and processing history. Mass spectrometric-based techniques currently used for particle population analysis often suffer from limited mass resolution, particularly when dealing with real-world samples that are affected by isobaric and polyatomic interferences from the matrix. To address these analytical challenges, we propose a novel method utilizing the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an ultrahigh resolution Orbitrap mass spectrometer, further enhanced with the FTMS X2T Booster data acquisition and processing unit. The FTMS Booster enables acquisition of extended transient times of up to 3 s, significantly improving mass resolution, thereby reducing or even eliminating the need for prior separation of isobaric or polyatomic interferences. Additionally, the detection of low-abundance isotopes was improved by increasing the signal-to-noise (S/N) ratio. As proof of concept, this study demonstrates the feasibility of the LS-APGD/Orbitrap-FTMS X2T Booster platform for direct analysis using a suspension of well-characterized ∼120 nm neodymium particles. The quality of the isotope ratios values obtained from a few hundred particles were in good agreement with those obtained from homogeneous ionic solutions. These results highlight the potential of the LS-APGD/Orbitrap platform for rapid, accurate, and interference-resilient isotope ratio analysis of particle populations without the need for dissolution and subsequent chemical separations, offering significant advantages for nuclear forensics, safeguards, and environmental applications. The effort here also points to further paths forward, hopefully towards single particle (SP) analysis using microplasma ionization and the ultrahigh resolving power of the Orbitrap mass analyzer.

FTMS X2T booster↗

Complete resolution across the neodymium/samarium isotopic envelope with a liquid sampling‐atmospheric pressure glow discharge — Orbitrap mass spectrometer

Rationale Nd and Sm isotope ratios play an important role in geological dating and as nuclear forensic signatures; however, the overlap of the respective 144, 148, 150 Nd/Sm isobars requires prior separations to be performed before analysis on typical MS platforms. The work presented here overcomes these isobaric interferences using ultrahigh‐mass resolution to alleviate interference without prior chemical separations. Methods A liquid sampling‐atmospheric pressure glow discharge ion source was coupled to a standard, QExactive Focus Orbitrap mass spectrometer, providing a mass resolution of ~80 k. A Spectroswiss FTMS booster X2 data acquisition package was used to collect extended transients, providing much higher mass resolution; ~230 k and ~600 k are employed here for Nd and Sm isotopes. Results While the standard Orbitrap resolution is far greater than typical “atomic” MS platforms, it was insufficient to alleviate all isobars. The use of a resolution of ~230 k resulted in baseline separation across the entire isotopic envelope for both Nd and Sm. Isotope ratios obtained from Nd:Sm mixtures using high‐resolution were equivalent to those found for individual‐element solutions, while isotope ratios obtained at a resolution of ~80 k (standard for the OEM data system) showed large deviations. Conclusions Use of ultrahigh‐resolution is an attractive alternative to extensive chemical separations to alleviate severe isobaric interferences. Sufficient mass resolution greatly reduces/eliminates the need for sample manipulations (separations) before analysis while reducing costs and total analysis times.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup↗

Ultra-selective membrane composed of charge-stabilized fixed carrier and amino acid-based ionic liquid mobile carrier for highly efficient carbon capture

Membrane technology has been extensively studied for CO 2 capture applications, especially for flue gas sources. In the past decades, facilitated transport membranes (FTMs) have made breakthroughs overcoming the permeance-selectivity trade-off upper bound restricting traditional CO 2 separation membranes, but are still facing challenges towards practical applications, including limited performance, such as insufficient CO 2 /N 2 selectivity to achieve 95 % CO 2 dry-base purity by one step separation, and long-term stability. Herein, we designed and fabricated a novel FTM structure containing an ionic liquid (1-ethyl-3-methylimidazolium aminoacetate, [Emim][Gly]) as mobile CO 2 -carrier and a polymeric amine (polyethyleneimine, PEI) as fixed CO 2 -carrier. In this study, the fixed carrier is confined within a carbon nanotube (CNT) framework of 230 nm thickness via electrostatic forces adjusted by a polyelectrolyte (polystyrene sulfonate, PSS), while the mobile carrier diffuses freely within the CNT framework. After optimization of the membrane recipe and spray-coating fabrication procedure, following our previous work, the resulting CNT-PSS-PEI ~ IL membranes demonstrated an ultra-high CO 2 /N 2 selectivity up to 1,000 with CO 2 permeance up to 2,400 GPU (Gas Permeation Unit, 1 GPU = 3.348 × 10 -10 mol·s -1 ·m -2 ·Pa -1 ) under vacuum operation condition. Furthermore, one 100-cm 2 flat sheet membrane sample was prepared and exhibited one-stage CO 2 enrichment from 15 % to 95 % purity (dry-base) for the first time amongst all reported CO 2 separation membranes. The membrane retained a stable performance over 50-h operation period under vacuum condition. The extraordinary CO 2 separation performance illustrates the great potential of the CNT-PSS-PEI ~ IL membranes for flue gas carbon capture application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Parametric optimization of the liquid sampling-atmospheric pressure glow discharge ionization source coupled to an Orbitrap mass spectrometer for neodymium isotope ratio determinations

Isotope ratio determinations are a valuable tool in several application areas. In nuclear forensics, the isotope ratios of uranium and plutonium are commonly used as a signature for the nuclear material's provenance and processing history. However, signatures from other coexisting elements, such as neodymium and samarium, can offer additional insights. Here, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source coupled to an Orbitrap mass spectrometer (MS) has demonstrated its utility for actinide measurements. This instrumental platform can leverage the high resolution offered by the Orbitrap MS to overcome potential isobaric interferences, such as 144 Nd- 144 Sm, 148 Nd- 148 Sm, and 150 Nd- 150 Sm pairs. The work presented herein demonstrates the rapid, accurate, and precise determination of the isotope ratios for neodymium using the LS-APGD/Orbitrap MS. Both the LS-APGD and Orbitrap MS parameters were optimized systematically, with NdO + found to be the most abundant, most reduced species after applying the optimal collision-induced dissociation modalities. A limit of detection of 3 pg of 142 Nd was achieved when data was acquired and processed using the FTMS Booster, an external data acquisition and processing system offered by Spectroswiss. Excellent accuracy of better than 99 % and precision of <1 % RSD were achieved when a solution of the well-characterized neodymium standard (JNdi-1 standard) was analyzed under the optimized condition, indicating the LS-APGD/Orbitrap's great potential for isotope ratio analysis of Nd and other REEs for diverse applications.

47 OTHER INSTRUMENTATION↗

Two-stage membrane-based process utilizing highly CO 2 -selective membranes for cost and energy efficient carbon capture from coal flue gas: A process simulation study

Membrane technology for CO 2 capture has become an attractive strategy due to its cost and energy efficiency and low materials costs. In the past decade, membrane-based process designs for post-combustion power plant CO 2 capture have been developed, utilizing existing highly CO 2 -permeable membranes with relatively low CO 2 /N 2 selectivity (<50), and have obtained reasonably economic carbon capture. However, few membrane-based process designs were proposed for moderate to highly CO 2 -selective membranes (CO 2 /N 2 selectivity of 50–300, and >300, respectively), which have vastly emerged in recent years, such as various facilitated transport membranes (FTMs). Herein, we proposed a two-stage membrane-base process design targeting economic carbon capture from coal-fired flue gas. This process design features the utilization of highly CO 2 -selective membranes for one-stage CO 2 enrichment to 95% dry-base purity in the first stage and recycle of the remaining CO 2 by a highly CO 2 -permeable membrane in the second stage, in order to achieve economic CO 2 capture with 90% capture rate and >95% CO 2 product purity. Through an integration-iteration membrane model and the Aspen Plus process simulation, a sensitivity study of operating pressures (feed and permeate pressures) and membrane properties (CO 2 permeance and CO 2 /N 2 selectivity) was conducted. Critical CO 2 /N 2 selectivity of 300–400 was found for the highly CO 2 -selctive membranes to meet the demand for cost and energy efficient results. The lowest possible membrane area of 4.8 × 10 5 m 2 and fractional energy of 19.3% were obtained, which is comparable to or even more attractive than reported membrane-based process designs. Here, this work provides a new membrane process design option for highly CO 2 -selective membranes and gives insights on the influence of membrane performance and operation condition.

42 ENGINEERING↗

Natural Abundance Isotope Ratio Measurements of Organic Molecules Using 21 T FTICR MS

Subtle variations in stable isotope ratios at natural abundance are challenging to measure but can yield critical insights into biological, physical, and geochemical processes. Well established methods, particularly multi-collector, gas-source or plasma isotope ratio mass spectrometry (IRMS) are the gold standard for stable isotope measurement but inherent limitations in these approaches make them ill-suited to determining site-specific and multiply substituted isotopic abundances of all but a few compounds, or to characterizing mixtures or larger intact molecules. Additionally, Fourier transform mass spectrometry (FTMS), namely Orbitrap mass spectrometry, has recently demonstrated the ability to measure natural abundance isotope ratios with chemically informative accuracy and precision. Here, we report the first use of Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) for the accurate (<1‰) and precise (<1‰ standard error) simultaneous determination of $δ$ 13 C and $δ$ 15 N in caffeine isotopologues and provide a discussion of the critical instrumental parameters necessary to make such measurements. Finally, we report the ability to make these measurements with online liquid chromatography, expanding the ability of this technique to explore mixtures in the future.

07 ISOTOPE AND RADIATION SOURCES↗

Initial Characterization and Optimization of the Liquid Sampling-Atmospheric Pressure Glow Discharge Ionization Source Coupled to an Orbitrap Mass Spectrometer for the Determination of Plutonium

Plutonium measurements are essential to the nuclear forensics and safeguards community. The liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled with an Orbitrap mass spectrometer is a proven platform for uranium isotope ratio determinations. Here, this work expands the LS-APGD-Orbitrap platform capabilities by reporting the first-ever analysis of plutonium with the LS-APGD and the first-ever measurement of elemental plutonium with an Orbitrap mass spectrometer. This coupling has the potential to dramatically reduce the complex sample manipulations required for traditional analysis techniques employed for actinide isotope ratio determinations. As a first step toward the goal of simultaneous uranium and plutonium isotope ratio determinations, the initial characterization and optimization of the platform for the detection of plutonium are reported. Collision-induced dissociation modality settings were optimized to reduce water-related and other molecular clusters containing plutonium, maximizing 242 Pu 16 O 2 + responses. A design of experiments study was conducted to optimize the discharge conditions of the dual-electrode LS-APGD toward the responsivity of 242 Pu 16 O 2 +. The measurement sensitivity was determined from a Pu response curve, yielding a limit of detection of 10 fg (absolute) of total analyte when data was collected and processed with a Spectroswiss FTMS Booster X2 data acquisition system. Additionally, plutonium and uranium were measured in a simultaneous acquisition, and each analyte remained unaffected by the other. It is believed that the LS-APGD-Orbitrap platform could be a valuable addition to the nuclear forensics’ toolbox and, indeed, other scientific disciplines and regulatory communities in which rapid, high-resolution plutonium determinations are paramount.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single-Particle Isotopic Analysis Using the Liquid Sampling-Atmospheric Pressure Glow Discharge Microplasma Coupled to an Orbitrap Mass Spectrometer

Isotope ratio (IR) determinations on individual particles can provide valuable information relative to the sample, including processing and dating, which could be valuable to geological and nuclear material analysis communities. In comparison to “bulk” measurements, in which all particle information is lost and homogenized within a sample, “particle” measurements allow for fingerprinting and can provide unique insights related to the sample’s nano- and micro- compositions. Furthermore, the complex nature of particles, with potential isobaric interferences from either the matrix or other elements within the same particle, poses a significant analytical challenge for conventional mass spectrometry platforms employed for elemental analysis due to their limited mass resolution. Presented here is the first demonstration of an ultrahigh resolution method for single particle (SP) isotopic analysis using the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an Orbitrap mass spectrometer and FTMS Booster X2T acquisition/processing system. For proof of concept, well-characterized CeO 2 microparticles with a nominal diameter of 1.0 μm were analyzed at a mass resolution of ∼330,000. Important instrumental parameters were optimized to enable the detection of single particles. The 142 Ce/ 140 Ce ratio of individual particles and the population average were determined and compared to an SP inductively coupled plasma time-of-flight mass spectrometry (ICP-TOF-MS) analysis. The isotopic accuracy and precision were determined by two methods and found to be in good agreement with the SP-ICP-TOF-MS method, with the linear regression slope method providing a more accurate ratio, showing a ∼1.4% relative difference from the ratio determined from a particle digest. The encouraging performance of the method was further supported by a determined detection limit of 2.9 fg ( 142 Ce). The developed method is anticipated to overcome many of the challenges posed by isobaric interferences encountered in conventional mass spectrometry techniques when analyzing real-world samples for particle isotopic composition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adverse Effect of Polyelectrolyte Complexation on the CO 2 Permeability of Polyvinylamine Copolymers

Polyvinylamine (PVAm) is one of the most studied polymers for facilitated transport membranes (FTMs) in CO 2 separation applications. In this study, poly(N-vinylformamide) (PNVf) was hydrolyzed to prepare a range of PNVf-PVAm copolymer compositions and the effect of PVAm fraction on CO 2 permeability and CO 2 /N 2 selectivity these polymers examined. The most permeable film was the polymer containing 52 mol% PVAm units with a CO 2 permeability of 353 Barrer and CO 2 /N 2 selectivity of 96, when tested at 60°C with humidified 14/86 CO 2 /N 2 mixed gas. Despite containing a higher loading of amines to act as CO 2 carriers, higher PVAm contents yielded significantly lower CO 2 permeability, without a loss of selectivity. This trend was not due to polymer crystallization since none of the PVAm films exhibited crystallinity in X-ray diffraction analysis. The loss of gas permeability at high PVAm content was instead due to strong polyelectrolyte interactions between polymer chains formed when PVAm reacts with CO 2 . Since only the PVAm units are ionized upon reaction with CO 2 , with the PNVf units remaining neutral, the density of these ionic effects increased as PVAm content increased, leading to increased resistance to gas permeation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗