Search NASA⌕ Search

SEARCH · Search NASA

Results for “FWHM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The Effects of Experimentally Induced Zircon Annealing on Melt Inclusion-Zircon Geochemistry: A Case Study of Archean Zircon From the Barberton Complex

Crystalline melt inclusions (MIs) in Archean zircons can potentially constrain the evolution of magmatic processes. However, to obtain a homogeneous glassy MI representative of the parent melt, devitrified MIs must be heated at temperatures above the liquidus. Although, it is well known that radiation damaged domains in MI-host zircon undergo temperature-time dependent annealing, the effects of annealing on zircon stable isotope and trace element compositions has received less attention. In this study, we heated multiple aliquots of low-magnetism zircons with relatively low levels of radiation damage (Deff<9.6x1014 α-events/mg) from a 3.304 Ga tonalite gneiss xenolith from the Barberton greenstone belt (sample B87-18; Kamo and Davis, 1994) in an internally-heated pressure vessel at 0.4GPa and 1000–1200°C. Zircons were imaged by SEM (CL, BSE) to determine the zoning patterns around the MIs. The radiation damage preserved in the heated and unheated zircons was determined by measuring broadening of the 3(SiO4) Raman stretching band of zircon (FWHM). Oxygen isotope ratios (δ18O), OH/O ratios, and trace and rare earth element (TREE) concentrations were measured in the zircons and MIs using SIMS. The FWHM and Raman shift of the zircon 3(SiO4) band show a systematic increase of zircon crystallinity with increasing experimental temperature. Despite increasing crystallinity, the 3(SiO4) FWHM is not correlated with δ18O(Zrn) values in the heated or unheated zircons, suggesting that δ18O was not altered by laboratory heating in these low initial radiation damage zircons. FWHM and OH/O are positively correlated in both heated and unheated zircons. The unheated zircons have the largest FWHM and OH/O (OH/OMAX=3.5×10-4) suggesting that H2O was lost during experimental heating due to the progressive annealing of radiation-damaged domains in the zircons. Zircon TREE concentrations and FWHM values are not correlated despite the presence of TREE altered domains in both the heated and unheated zircons. Our results demonstrate that pre-experimental zircon TREE concentrations and δ18O(Zrn) remain intact during laboratory heating of crystalline MIs in zircon, while secondary H2O hosted in radiation damaged domains is partially lost. Thus, MIs in low initial radiation damage Archean zircon are a potentially viable tool for constraining melt compositions.

Joseph P. Gonzalez↗

The intermediate line region of QSOs

Our recent statistical investigations of broad UV lines of luminous quasars (QSOs) suggest that the traditional broadline region (BLR) consists of two components-one of width approximately 2000 km/s FWHM with the peak within a few hundred kilometers per second of the systemic redshift, and another very broad component of width greater than or equal to 7000 km/s FWHM and blueshifted by greater than or equal to 1000 km/s. Differences in the relative strengths of these components account for much of the diversity of broad-line profiles, as well as relations among line strength, line width, asymmetry, and peak blueshift. We have suggested that the narrower component arises in a distinct intermediate-line region (ILR) that is an inner extension of the narrow-line region (NLR). We form spectra of the ILR and very broad line region (VBLR) in two complementary ways. First, using a small sample of high-quality spectra, we difference two composite spectra, one with FWHM (sub C IV) approximately 3000 km/s, the other with FWHM (sub C IV) approximately 7000 km/s (essentially a VBLR spectrum)-revealing a narrower line spectrum with FWHM approximately 2000 km/s. Second, we use a principal component analysis of 200 low signal-to-noise ratio spectra from the Large Bright Quasar Survey. The ILR is identified with the first principal component-that component accounting for most of the spectrum-to-spectrum variation. The VBLR spectrum is derived by subtracting this ILR from the mean spectrum. The two methods yield similar results, and the spectra of the ILR and VBLR are very different. Additional support for the existence of two component is the lack of a correlation between the equivalent widths of the ILR and VBLR. We discuss the relationships between the VBLR, the ILR, and the traditional NLR. The ILR line intensity ratios are distinctly different from those of the VBLR, with (relative to C IV lambda 1549) stronger Lyman alpha and weaker N v lambda 1240, lambda 1400 feature, He II lambda 1640, O III lambda 1663, and Al III lambda 1860. Comparison with other active galactic nuclei (AGN) emission-line regions shows that the ILR spectrum tends to be intermediate between that of the VBLR and that of gas more distant from the ionizing continuum, such as the NLR and extended Lyman alpha nebulosity. Comparison of the spectra with results from photoionization models suggests that, compared with the VBLR, the ILR is about 10 times more distant from the ionizing continuum (approximately 1 pc), 100 to 1000 times less dense (10(exp 10)/cu cm), and has a smaller covering factor (less than or approximately 3%, compared with approximately 24% for the VBLR).

Brotherton, M. S.↗

Multiabsorber Transition-Edge Sensors for X-Ray Astronomy

We are developing arrays of position-sensitive microcalorimeters for future x-ray astronomy applications. These position-sensitive devices commonly referred to as hydras consist of multiple x-ray absorbers, each with a different thermal coupling to a single-transition-edge sensor microcalorimeter. Their development is motivated by a desire to achieve very large pixel arrays with some modest compromise in performance. We report on the design, optimization, and first results from devices with small pitch pixels (<75 μm) being developed for a high-angular and energy resolution imaging spectrometer for Lynx. The Lynx x-ray space telescope is a flagship mission concept under study for the National Academy of Science 2020 decadal survey. Broadband full-width-half-maximum (FWHM) resolution measurements on a 9-pixel hydra have demonstrated ΔE(FWHM) = 2.23 ± 0.14 eV at Al-Kα, ΔE(FWHM) = 2.44 ± 0.29 eV at Mn-Kα, and ΔE(FWHM) = 3.39 ± 0.23 eV at Cu-Kα. Position discrimination is demonstrated to energies below <1 keV and the device performance is well-described by a finite-element model. Results from a prototype 20-pixel hydra with absorbers on a 50-μm pitch have shown ΔE(FWHM) = 3.38 ± 0.20 eV at Cr-Kα1. We are now optimizing designs specifically for Lynx and extending the number of absorbers up to 25/hydra. Numerical simulation suggests optimized designs could achieve ∼3 eV while being compatible with the bandwidth requirements of the state-of-the art multiplexed readout schemes, thus making a 100,000 pixel microcalorimeter instrument a realistic goal.

Smith, Stephen J.↗

First results of the NEXT-100 detector using $^{83m}$Kr decays

The NEXT collaboration is investigating the double beta decay of $ ^{136}\mathrm Xe$ using high-pressure gas electroluminescent time projection chambers, which provide excellent energy resolution together with a robust topological signature. Operating at the Laboratorio Subterráneo de Canfranc (LSC) and building on the success of the NEXT-White detector, the NEXT-100 apparatus began commissioning in May 2024 and started operation with xenon at a pressure of 4 bar in October 2024. We report here the first results obtained with NEXT-100 using low-energy calibration data from $^{83\text {m}}\textrm{Kr}$ decays, which allow mapping of the detector response in the active volume and monitoring of its stability over time. After homogenizing the light response, we achieve an energy resolution of 4.37% FWHM at 41.5 keV for $^{83\text {m}}\textrm{Kr}$ point-like energy deposits contained in a radius of 425 mm. In a fiducial region representing the operating conditions of NEXT-100 at 10 bar we obtain an improved energy resolution of 4.16% FWHM. These results are in good agreement with that obtained in NEXT-White, and an $E^{-1/2}$ extrapolation to $Q_{\beta \beta }$ yields an energy resolution close to 0.5% FWHM, well below the 1% FWHM design target.

Martínez-Lema, G. [Donostia Intl. Phys. Ctr., San ↗

Properties of an imaging gas scintillation proportional counter

An instrument which combines the improved energy resolution offered by the gas scintillation proportional counter (GSPC) with the submillimeter imaging capabilities of the multiwire proportional counter (MWPC) is described. The imaging gas scintillation proportional counter detects the centroid of the UV light excited by X-ray photons interacting in the noble gas of the GSPC with a UV sensitive gas in the MWPC. The prototype counter yields a measured performance of 9% (FWHM) energy resolution and 0.9 mm (FWHM) spatial resolution at 6 keV. Further design refinements should achieve 18% (FWHM) energy resolution and 0.6 mm (FWHM) spatial resolution at 1 keV.

Ku, W. H.-M.↗

An imaging gas scintillation proportional counter for use in X-ray astronomy

An imaging gas scintillation proportional counter (GSPC) has been constructed for use in X-ray astronomy. The IGSPC consists of a gas scintillation proportional counter (GSPC) with a 1 micron polypropylene window coupled to a multiwire proportional counter (MWPC) via a calcium fluoride window. The MWPC, filled with a mixture of argon, methane, and tetrakis (dimethylamino) ethylene, detects the UV photons emitted by the xenon gas in the GSPC. The measured energy resolution is 17.0 percent (fwhm) and 8.0 percent (fwhm) at 1.5 keV and 5.9 keV, respectively. The measured position resolution is 1.9 mm (fwhm) and 0.9 mm (fwhm) at 1.5 and 5.9 keV, respectively. Possible astrophysical observations which can be performed with an IGSPC at the focal plane of a grazing incidence telescope are also discussed.

Hailey, C. J.↗

An imaging study of NGC 1275 and PKS 0745-191 - Vigorous star formation in cooling flow cluster dominant galaxies

Observations of NGC 1275 and PKS 0745-191, obtained at 8290 A (FWHM 1900 A) and 4506 A (FWHM 355 A) using a UV-flooded 800 x 800 CCD detector on the 2.3-m telescope at Steward Observatory on December 9, 1986, are reported along with additional observations of PKS 0745-191 at 7240 A (FWHM 78 A) and 6737 A (FWHM 86 A). The results are presented graphically and analyzed in detail. Both of these cluster-central galaxies are shown to have strong cooling flows, total H-alpha luminosities of 4.8 x 10 to the 42nd erg/s, large color gradients (bluer centers), and a blue excess relative to normal old elliptical galaxies (probably indicating star formation at a few times 10 solar mass/yr).

Romanishin, W.↗

Nondestructive evaluation of fatigue damage in aluminum 2024 by x-ray diffraction

Aluminum alloys are widely used in the automobile and aerospace industries. This is due to their attractive low density-high modulus and low density-high strength characteristics. Unfortunately, cyclic stress-strain deformations alter the microstructure of aluminum alloys when they are placed into service. These structural changes can lead to fatigue damage and ultimately service failure. Since x-ray diffraction analysis is known to be a sensitive nondestructive indicator of structural changes due to deformations, this technique is being used to evaluate changes in the microstructure of cycled aluminum 2024 commercial alloys. Line shapes, widths, and positions in an x-ray diffraction pattern depend on microstructural properties such as grain size, grain orientation, residual stress, microstrain, etc. Changes in the microstructure due to fatigue will appear as changes in the diffraction pattern. One parameter used to characterize a reflection in a diffraction pattern is the full width at half maximum (FWHM). Preliminary x-ray diffraction results on cycled Al 2024 indicate that the (111) and (222) reflections of the matrix phase do not show any variations in the FWHM due to an increase in the fatigue cycles. However, the FWHM of the (200) and (400) reflections of the same phase unexpectedly showed a dramatic decrease. These results can be interpreted as due to the relaxation of some initial nonuniform residual stresses in the matrix phase lattice. Further work is in progress to evaluate the FWHM of the second phase of the cycled alloys.

Ferguson, Milton W.↗

Determining True Sensor Spatial Resolution of Very High Resolution Optical Imagery

Some satellite data is delivered in images with gridded pixels. This gridded pixel size is often assumed to be the spatial resolution of the satellite sensor; however, this is not always the case. An image can be grided to any arbitrary pixel size, but the sensor resolution will remain constant. For example, an image with a pixel grid size much smaller than the sensor resolution will appear blurry along what should be sharp transitions. This discrepancy between an image’s pixel size and true sensor spatial resolution can be the source of much confusion and even misinformation among data users, which may lead them to waste time and resources on using images that do not suit their spatial resolution needs. This presentation will highlight our evaluation of the true spatial resolution of various government and commercial images in the pixel size range of 0.3 m to 60 m. Images evaluated include ESA’s Sentinel-2 (60 m, 20 m, 10 m pixels), USGS’s Landsat 8/9 (30 m & 15 m pixels), Planet’s SuperDoves (3 m pixels), BlackSky’s Globals (~1 m pixels), and the optical bands of Maxar’s WorldView-2 (2.4 m – 0.41 m pixels) and WorldView-3 (1.38 m – 0.31 m pixels). Our evaluation of true sensor spatial resolution, or ‘footprint size’ is based on the sensor’s line spread function (LSF). We calculate the width at half the height of the LSF to find the full width at half maximum (FWHM). The FWHM is how we report sensor spatial resolution. Different objects are examined for constructing the LSF depending on the sensor spatial resolution. Coarser resolution sensors in this evaluation such as Sentinel-2 and Landsat 8/9 are examined at bridges over a dark water background. The bright bridge acts as a line impulse, giving a sensor’s line spread function (LSF) in one direction. Additionally, we simulate the impacts of bridge width on the apparent LSF to obtain a true LSF without the effects of bridge width for these sensors. Finer resolution sensors will image the irregularities in bridges such as trusses, sidewalks, and in some cases painted lines, interfering with the LSF construction. Instead, these sensors are evaluated at large (60 m – 140 m) black and white checkerboards known as Cal/Val sites. At these locations, the image’s transition from black to white is extracted as an edge spread function (ESF). We calculate the derivative of this ESF to obtain the sensor’s LSF. From there, we find the FWHM as we do for the coarser resolution images. With the FWHM and pixel size, we determine how over- or under-sampled the images are. When the ratio of a sensor’s spatial resolution and the gridded image’s pixel size is less than 1, the image is considered under-sampled. In this case, each pixel’s information is unique but only a portion of that pixel’s ground area has been measured. On the other side, if the ratio is greater than 1, the image is considered over-sampled. That is, each pixel’s information is sourced from within the ground extent of the pixel and some extent outside additionally. We will show the true spatial resolution and the extent of over-/under-sampling in the imagery from ESA’s Sentinel-2 (60 m, 20 m, 10 m pixels), USGS’s Landsat 8/9 (30 m & 15 m pixels), Planet’s SuperDoves (3 m pixels), BlackSky’s Globals (~1 m pixels), and the optical bands of Maxar’s WorldView-2 (2.4 m – 0.41 m pixels) and WorldView-3 (1.38 m – 0.31 m pixels).

Alana Semple↗

Characterization of the upgraded single-line-of-sight time-resolved x-ray imager using short-pulse visible and UV lasers

The single-line-of-sight time-resolved x-ray imager (SLOS-TRXI), a fast-gated x-ray imager used for capturing x-ray self-emission in inertial confinement fusion experiments on OMEGA, has been upgraded and characterized. SLOS-TRXI combines an electron-dilation imager and a hybrid complementary metal–oxide–semiconductor (hCMOS) sensor to capture multiple gated frames on a single line of sight with a temporal resolution of ~40 ps and a spatial resolution of 10 µm. The original hCMOS sensor with four frames was replaced with a newer-generation hCMOS sensor having eight frames. Gate characterizations of both the sensor and the entire SLOS-TRXI diagnostic were performed using ~10-ps FWHM visible (2ω) and UV (4ω) short-pulse lasers, respectively. A stepped echelon was used to generate a train of five UV laser pulses having an interpulse separation of 30 ± 3 ps. Characterization results of the hCMOS gating (2.28 ± 0.02-ns FWHM on average) and a temporal resolution of the upgraded SLOS-TRXI (34 ± 4-ps FWHM on average) are presented. A temporal magnification for the electron-dilation imager between 40 and 60 was inferred from the characterization results. Furthermore, the spatial resolution of the upgraded SLOS-TRXI remains the same in light of this work.

47 OTHER INSTRUMENTATION↗

Performance of an X-γ ray detection system based on a thick silicon LGAD

We present the performance of a X-γ ray detection systems based on a 300 µm thick silicon low-gain avalanche diode (LGAD) and of an equivalent Diode structure without the gain layer, read-out by a custom-made low-noise charge amplifier. For the LGAD structure, the multiplication gains M s from 10.2 to 19.3 are measured, and the Equivalent Noise Charge (ENC) components have been studied in detail. As expected, a significant reduction of the white and 1/f voltage series and dielectric ENC components is observed with increasing gain, shortening the optimum peaking time to τ = 0.4÷8 μs depending on the gain value, with respect to the standard diode, while the parallel ENC component increases proportionally to the gain up to M s = 15. Setting the gain M s = 12.7, a minimum ENC = 34.5 electrons r.m.s. (298 eV FWHM) at τ = 1 μs is found. However, the electronic noise, evaluated on the pulser FWHM, is found to only marginally contribute to the width of the spectral lines of a radioactive source, which are dominated instead by the statistical noise of the charge multiplication within the LGAD structure. The spectral lines' excess width is found to be proportional to the signal multiplication gain M s and increases with the energy of the photons. A minimum line width of 850 eV FWHM at 13.9 keV is measured at room temperature, τ = 2 μs and a gain M s = 10.2.

47 OTHER INSTRUMENTATION↗

Few-femtosecond time resolution in optically pumped hard X-ray scattering at a free-electron laser

Capturing chemical dynamics in real time is a central goal of ultrafast science, necessitating measurements fast enough to track atomic motion on few-femtosecond timescales with high precision. We present time-resolved hard X-ray scattering that meets these criteria by combining 7 fs full-width at half maximum (FWHM) near-infrared laser pulses with sub10 fs FWHM hard X-ray pulses from a free-electron laser. Using heavy water’s electronic response to strong-field ionization as a benchmark, we achieve a sub-8 fs FWHM instrument response function. These optical pump X-ray probe measurements enable direct observation of chemical dynamics with angstrom spatial and few-fs temporal resolution.

Weckwerth, Eleanor [Stanford University, CA (Unite↗

Direct Measurement of Light Scattering and Quantum State Preservation from Non-Specular Materials [Slides]

Conclusions from Bidirectional Reflectance Distribution Function (BRDF) Measurements: Mirrors are specular and have consistent reflectance over a range of angles. The measured power of the reflected light was consistent for all power meter positions; Kapton had a similar specular response as the mirror (FWHM), but displayed varying power levels for the different power meter positions (much like the Anodized AI and the Solar Cells); The Solar Cells had very high loss consistent with a material that is supposed to absorb light, but still exhibited specular behavior for FWHM; The Anodized AI had the most diffuse (highest FWHM) reflectance and low BRDF amplitude; Also tried to measure the BRDF Aeroglaze (a common satellite coating) but the power meter was not sensitive enough. To the eye, this material seemed very absorbent and any reflection would be very diffuse.

36 MATERIALS SCIENCE↗

A thick Anger camera for gamma-ray astronomy

The NaI(Tl) Anger camera is a natural candidate for a position sensitive detector in imaging of astrophysical gamma-ray sources. Here laboratory measurements are presented of the response of a relatively thick (5.1 cm) NaI(Tl) Anger camera designed for coded aperture imaging in the 50 keV to 2 MeV energy range. A position resolution of 10.5 mm FWHM at 122 keV and 6.3 mm FWHM at 662 keV. The energy resolution was 7 percent FWHM at 662 keV. The ability of the detector to resolve the depth of the gamma-ray interaction and the use of this depth resolution to reduce back-incident and internal background is discussed.

Cook, W. R.↗

A large area imaging gas scintillation proportional counter for use in X-ray astronomy

A large area (200 sq cm), broad bandwidth (0.1-70 keV), imaging gas scintillation proportional counter (IGSPC) has been constructed for use in X-ray astronomy. The IGSPC consists of a high pressure xenon gas scintillation proportional counter (GSPC) coupled to a multi-wire proportional counter (MWPC) via a calcium fluoride window. THe MWPC, filled with a mixture of argon, methane, and tetrakis (dimethylamino) ethylene, detects the UV photons emitted by the xenon gas in the GSPC. The detector has a measured energy resolution of 8.0 percent (FWHM) and 4.3 percent (FWHM) at 5.9 keV and 22.1 keV, respectively. The predicted spatial resolution of the detector is less than 1 mm (FWHM) between 3-22 keV and 37-60 keV. A method to determine the three-dimensional location of detected X-rays is described. In addition, a combination of discrimination schemes designed to reduce the non-X-ray background in the IGSPC by more than two orders of magnitude is discussed.

Ku, W. H.-M.↗

Low energy X-ray spectra measured with a mercuric iodide energy dispersive spectrometer in a scanning electron microscope

A mercuric iodide energy dispersive X-ray spectrometer, with Peltier cooling provided for the detector and input field effect transistor, has been developed and tested in a scanning electron microscope. X-ray spectra were obtained with the 15 keV electron beam. An energy resolution of 225 eV (FWHM) for Mn-K(alpha) at 5.9 keV and 195 eV (FWHM) for the Mg-K line at 1.25 keV has been measured. Overall system noise level was 175 eV (FWHM). The detector system characterization with a carbon target demonstrated good energy sensitivity at low energies and lack of significant spectral artifacts at higher energies.

Iwanczyk, J. S.↗

Delay line anodes for microchannel-plate spectrometers

A photon-counting readout system for microchannel-plate spectrometers is described that uses a delay line and timing circuit for the wavelength coordinate and a wedge-wedge charge division system for the orthogonal spatial coordinate. A novel zigzag layout allows these two anode patterns to coexist on a common planar substrate and share the charge from each photoevent, thereby simultaneously localizing the photon in each of its two dimensions. Unlike wedge-and-strip or resistive anode encoders, the delay line offers a spatial resolution that is relatively independent of the format length. Unlike discrete anode systems, the delay line readout system's complexity is also independent of the field of view size. These facts make the delay line readout system advantageous in large format detectors. A testbed detector having a delay line propagation speed of 2.2 mm/ns and a time resolution of 33 ps FWHM has been assembled. Ultraviolet testing shows a Gaussian event distribution having a 70-micron FWHM width; the readout system blur contribution is less than 50-micron FWHM.

Lampton, M.↗

Resonance scattering by sodium in Mercury's atmosphere. I - The effect of phase and atmospheric smearing

The dependence of the intensity in the sodium D1 and D2 lines on the planetary phase and position of the disk is presented. Theoretical intensities are convolved with an atmospheric point spread function with FWHM of 0.5 and 2.0 arcsec for planetary phases 60 and 90 deg. It is shown that although the absolute intensities are extremely dependent on seeing, the I(D2)/I(D1) ratio remains a reliable indicator of column abundance regardless of the seeing function. For a uniform distribution of sodium, limb brightening will be apparent for a seeing disk with FWHM of 0.5 arcsec but will not be apparent for a FWHM of 2.0 arcsec.

Killen, R. M.↗