At least 19 records

A High-Temperature Multipoint Hydrogen Sensor Using an Intrinsic Fabry–Perot Interferometer in Optical Fiber

This paper presents a multiplexable fiber optic chemical sensor with the capability of monitoring hydrogen gas concentration at high temperatures up to 750 °C. The Pd-nanoparticle infused TiO 2 films coated on intrinsic Fabry–Perot interferometer (IFPI) array were used as sensory films. Strains induced upon exposure to hydrogen with varied concentrations can be monitored by IFPI sensors. The fiber sensor shows a repetitive and reversible response when exposed to a low level (1–6%) of hydrogen gas. Uniform sensory behavior across all the sensing cavities is demonstrated and reported in this paper.

47 OTHER INSTRUMENTATION↗

Simultaneous measurement of temperature and strain by cascaded fiber Bragg grating-silicon Fabry-Perot interferometer sensor

We report a fiber-optic sensor configuration with a cascaded fiber Bragg grating (FBG) and a silicon Fabry-Perot interferometer (FPI) for simultaneous measurement of temperature and strain. The sensor is composed of a 5 mm FBG on a single mode fiber and a 100μm thick silicon FPI attached to the tip of the optical fiber. The FBG is surface mounted on the host structure, and the FPI tip is suspended. Due to the stress-free, cantilever configuration, the silicon FPI is insensitive to strain, but sensitive to temperature with a sensitivity much higher than the FBG due to the large thermo-optic coefficient of silicon. The sensor is tested from room temperature to 100°C with varying strain up to ∼150με. The silicon FPI provides high temperature sensitivity of 89 pm/°C unaffected by strain. Since the FBG is attached to the host structure, it is affected by both thermal and mechanical strain; the sensitivity of these was experimentally obtained 32 pm/°C and 1.09 pm / με, respectively. Interrogated with a broadband light source and a high-speed spectrometer, the sensor shows temperature and strain resolutions of 1.9 × 10 −3 °C and 0.042 με, respectively. Here, due to the small size, enhanced sensitivity, and high resolution, this cascaded FBG-FPI sensor can be used in applications where accurate measurement of temperature and strain is required.

42 ENGINEERING↗

Differently Structured Fabry-Perot Interferometers for Gas Pressure Monitoring

In this study, we present an experimental comparison of gas pressure sensors based on differently structured extrinsic Fabry-Pérot interferometers (FPIs). Different fabrication techniques were adopted to foster the practical realization of these sensors. A novel photonic crystal fiber (PCF) based FPI with an angle cleaved end face that enables gas to easily flow in and out of the cavity while also avoiding the mixed signal from the cascaded structure is also presented. We measured helium gas pressure from 0.1 MPa (atmospheric pressure) to 5 MPa at room temperature and obtained a gas pressure sensitivity coefficient of 0.5±0.01 nm/MPa. Furthermore, the gas pressure sensitivities are numerically analyzed to validate the experimental results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active Compensation of Radiation Effects on Optical Fibers for Sensing Applications

Neutron and gamma irradiation is known to compact silica, resulting in macroscopic changes in refractive index (RI) and geometric structure. The change in RI and linear compaction in a radiation environment is caused by three well-known mechanisms: (i) radiation-induced attenuation (RIA), (ii) radiation-induced compaction (RIC), and (iii) radiation-induced emission (RIE). These macroscopic changes induce errors in monitoring physical parameters such as temperature, pressure, and strain in optical fiber-based sensors, which limit their application in radiation environments. We present a cascaded Fabry–Perot interferometer (FPI) technique to measure macroscopic properties, such as radiation-induced change in RI and length compaction in real time to actively account for sensor drift. The proposed cascaded FPI consists of two cavities: the first cavity is an air cavity, and the second is a silica cavity. The length compaction from the air cavity is used to deduce the RI change within the silica cavity. We utilize fast Fourier transform (FFT) algorithm and two bandpass filters for the signal extraction of each cavity. Inclusion of such a simple cascaded FPI structure will enable accurate determination of physical parameters under the test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of bulk-edge coupling on observation of anyonic braiding statistics in quantum Hall interferometers

Abstract Quantum Hall interferometers have been used to probe fractional charge and statistics of quasiparticles. We present measurements of a small Fabry–Perot interferometer in which the electrostatic coupling constants which affect interferometer behavior can be determined experimentally. Near the center of the ν = 1/3 state this device exhibits Aharonov–Bohm interference interrupted by a few discrete phase jumps, and Φ 0 oscillations at higher and lower magnetic fields, consistent with theoretical predictions for detection of anyonic statistics. We estimate the electrostatic parameters K I and K I L by two methods: using the ratio of oscillation periods in compressible versus incompressible regions, and from finite-bias conductance measurements. We find that the extracted K I and K I L can account for the deviation of the phase jumps from the theoretical anyonic phase θ a = 2 π /3. At integer states, we find that K I and K I L can account for the Aharonov–Bohm and Coulomb-dominated behavior of different edge states.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Distributed Acoustic Sensing Based on Coherent Microwave Photonics Interferometry

A microwave photonics method has been developed for measuring distributed acoustic signals. This method uses microwave-modulated low coherence light as a probe to interrogate distributed in-fiber interferometers, which are used to measure acoustic-induced strain. By sweeping the microwave frequency at a constant rate, the acoustic signals are encoded into the complex microwave spectrum. The microwave spectrum is transformed into the joint time–frequency domain and further processed to obtain the distributed acoustic signals. The method is first evaluated using an intrinsic Fabry Perot interferometer (IFPI). Acoustic signals of frequency up to 15.6 kHz were detected. The method was further demonstrated using an array of in-fiber weak reflectors and an external Michelson interferometer. Two piezoceramic cylinders (PCCs) driven at frequencies of 1700 Hz and 3430 Hz were used as acoustic sources. The experiment results show that the sensing system can locate multiple acoustic sources. The system resolves 20 nε when the spatial resolution is 5 cm. The recovered acoustic signals match the excitation signals in frequency, amplitude, and phase, indicating an excellent potential for distributed acoustic sensing (DAS).

47 OTHER INSTRUMENTATION↗

Real-time measurement of parametric influences on the refractive index and length changes in silica optical fibers

In this paper, we present a simple cascaded Fabry-Perot interferometer (FPI) that can be used to measure in real-time the refractive index (RI) and length variation in silica optical fibers caused due to external physical parameters, such as temperature, strain, and radiation. As a proof-of-concept, we experimentally demonstrate real-time monitoring of temperature effects on the RI and length and measure the thermo-optic coefficient (TOC) and thermal expansion coefficient (TEC) by using the cascaded FPI within a temperature range of 21–486°C. The experimental results provide a TEC of 5.53 × 10 −7 /°C and TOC of 4.28 × 10 −6 /°C within the specified temperature range. Such a simple cascaded FPI structure will enable the design of optical sensors to correct for measurement errors by understanding the change in RI and length of optical fiber caused by environment parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fiber-optic bolometers with high-temperature tolerance and reduced time constants for fusion plasma diagnostics

Fiber-optic bolometers (FOBs) designed for plasma radiation measurement in magnetically confined fusion environments have been previously developed and tested at the DIII-D tokamak. These FOBs utilize a silicon Fabry–Perot interferometer at the fiber tip for temperature measurement and a gold disk as a radiation absorber. This paper presents recent advancements in the development of FOBs with reduced cooling time constants and enhanced temperature tolerance. We also demonstrate high-temperature operation and report findings from irradiation tests. By incorporating a copper sensor holder as a thermal sink and integrating two closely packed sensor heads into a compact design, the cooling time constants were reduced to ∼100 ms in vacuum, while minimizing uncertainties caused by temperature gradients. The FOBs were subjected to heating at 400 °C for five hours, with no observed degradation in noise performance post-heating. High-temperature operation tests were conducted at ∼220 °C using a 404 nm square-wave modulated laser to simulate the plasma radiation. In addition, four FOBs constructed from copper-coated pure-silica fibers were fabricated and underwent irradiation testing, enduring a total γ-radiation dose of 15.2 MGy and a neutron fluence of 1.6 × 10 18 n/cm 2 . As a result, the FOBs maintained their physical integrity and the optical signal shows high visibility throughout the test.

42 ENGINEERING↗

Narrow-bandwidth tunable optical filter stabilized by Newton’s rings fringe analysis

The resolution of grating spectrometers is insufficient to resolve many features present in the emission spectra of solid-state quantum emitters. Spectral resolution may be improved by inserting a Fabry–Perot interferometer (FPI) whose length is tuned by a piezoelectric actuator. Yet piezo creep and thermal fluctuations cause instability that makes this solution unsuitable for measurement times longer than tens of seconds. To overcome this challenge, we employ active feedback derived from the Newton’s rings interference pattern formed by the reflection of a single-frequency laser from the FPI cavity. The resulting FPI transmission frequency is stable to within 50 MHz over several hours.

KC, Raju Bhai (ORCID:0000000267406588)↗

Fabrication of silicon-tipped fiber-optic temperature sensors using aerogel-assisted glass soldering with precise laser heating

We demonstrate the fabrication of fiber-optic Fabry–Perot interferometer (FPI) temperature sensors by bonding a small silicon diaphragm to the tip of an optical fiber using low melting point glass powders heated by a 980 nm laser on an aerogel substrate. The heating laser is delivered to the silicon FPI using an optical fiber, while the silicon temperature is being monitored using a 1550 nm white-light system, providing localized heating with precise temperature control. The use of an aerogel substrate greatly improves the heating efficiency by reducing the thermal loss of the bonding parts to the ambient environment. A desirable temperature for bonding can be achieved with relatively small heating laser power. The bonding process is carried out in an open space at room temperature for convenient optical alignment. The precise temperature control ensures minimum perturbation to the optical alignment and no induced thermal damage to the optical parts during the bonding process. For demonstration, we fabricated a low-finesse and high-finesse silicon FPI sensor and characterized their measurement resolution and temperature capability. The results show that the fabrication method has a good potential for high-precision fabrication of fiber-optic sensors.

Sheng, Qiwen↗

Super-resolution demodulation for fiber sensor arrays based on the MUSIC algorithm

This paper studies the use of MUltiple SIgnal Classification (MUSIC) as a super-resolution algorithm to improve demodulation results for intrinsic Fabry–Perot interferometer (IFPI) sensor arrays. Through distinction between noise and signal subspaces in an observation matrix, this paper shows that a 38-fold improvement in the full width at half maximum (FWHM) estimation of IFPI optical path differences (OPD) can be achieved using this algorithm. Based on this improved method, this paper demonstrates that a tunable laser with a 1.3-nm tuning range can achieve the same sensor demodulation performance as a tunable laser with a 50-nm tuning range if a conventional Fourier transform-based algorithm is used. This paper presents a new approach to analyzing optical signals produced by multiple multiplexed interferometers with similar OPDs with potential applications for both single-mode and multiple-mode devices.

Li, Yuqi (ORCID:0000000291643663)↗

A Hermetic Package Technique for Multi-Functional Fiber Sensors through Pressure Boundary of Energy Systems Based on Glass Sealants

This paper presents a hermitic fiber sensor packaging technique that enables fiber sensors to be embedded in energy systems for performing multi-parameter measurements in high-temperature and strong radiation environments. A high-temperature stable Intrinsic Fabry–Perot interferometer (IFPI) array, inscribed by a femtosecond laser direct writing scheme, is used to measure both temperature and pressure induced strain changes. To address the large disparity in thermo-expansion coefficients (TECs) between silica fibers and metal parts, glass sealants with TEC between silica optical fibers and metals were used to hermetically seal optical fiber sensors inside stainless steel metal tubes. The hermetically sealed package is validated for helium leakages between 1 MPa and 10 MPa using a helium leak detector. An IFPI sensor embedded in glass sealant was used to measure pressure. The paper demonstrates an effective technique to deploy fiber sensors to perform multi-parameter measurements in a wide range of energy systems that utilize high temperatures and strong radiation environments to achieve efficient energy production.

Optics↗

Fiber-optic bolometer with low detection limit fabricated using thermal release tape and precise laser heating

Fiber-optic bolometers (FOBs) based on a fiber-tipped silicon Fabry–Perot (FP) interferometric temperature sensor and a gold disk absorber have been shown to be an attractive alternative to conventional resistive bolometers for plasma radiation measurement in fusion devices. Either a high-finesse FP or a low-finesse FP can be used, each with trade-offs between noise performance and fabrication complexity. In this paper, we present an FOB design that overcomes these limitations by combining a low-finesse long silicon FP cavity with a large gold disk absorber to achieve enhanced sensitivity and noise performance without increasing the fabrication complexity and the time constant. We also demonstrated a fabrication method for the sensor head facilitated by thermal release tape and precise laser heating. Our FOB demonstrates a temperature resolution of 0.08 mK, a cooling time constant of 230 ms, and a noise equivalent power density of 0.015 W m −2 . This represents an eightfold improvement over previous high-finesse FOBs and 26-fold improvement over previous low-finesse FOBs with similar demodulation bandwidths and similar cooling time constants.

Fabry–Perot interferometer↗

Considerations in upconversion: A practical guide to sum-frequency generation spectrometer design and implementation

Here, in this tutorial review, we discuss how the choice of upconversion pulse shape in broadband vibrational sum-frequency generation (SFG) spectrometer design impacts the chemical or physical insights one can obtain from a set of measurements. A time-domain picture of a vibrational coherence being mapped by a second optical field is described and the implications of how this mapping, or upconversion process, takes place are given in the context of several popular and emerging approaches found in the literature. Emphasis is placed on broadband frequency-domain measurements, where the choice of upconversion pulse enhances or limits the information contained in the SFG spectrum. We conclude with an outline for a flexible approach to SFG upconversion using pulse-shaping methods and a simple guide to design and optimize the associated instrumentation.

47 OTHER INSTRUMENTATION↗