Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fabry-Perot interferometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Simultaneous measurement of temperature and strain by cascaded fiber Bragg grating-silicon Fabry-Perot interferometer sensor

We report a fiber-optic sensor configuration with a cascaded fiber Bragg grating (FBG) and a silicon Fabry-Perot interferometer (FPI) for simultaneous measurement of temperature and strain. The sensor is composed of a 5 mm FBG on a single mode fiber and a 100μm thick silicon FPI attached to the tip of the optical fiber. The FBG is surface mounted on the host structure, and the FPI tip is suspended. Due to the stress-free, cantilever configuration, the silicon FPI is insensitive to strain, but sensitive to temperature with a sensitivity much higher than the FBG due to the large thermo-optic coefficient of silicon. The sensor is tested from room temperature to 100°C with varying strain up to ∼150με. The silicon FPI provides high temperature sensitivity of 89 pm/°C unaffected by strain. Since the FBG is attached to the host structure, it is affected by both thermal and mechanical strain; the sensitivity of these was experimentally obtained 32 pm/°C and 1.09 pm / με, respectively. Interrogated with a broadband light source and a high-speed spectrometer, the sensor shows temperature and strain resolutions of 1.9 × 10 −3 °C and 0.042 με, respectively. Here, due to the small size, enhanced sensitivity, and high resolution, this cascaded FBG-FPI sensor can be used in applications where accurate measurement of temperature and strain is required.

42 ENGINEERING↗

Differently Structured Fabry-Perot Interferometers for Gas Pressure Monitoring

In this study, we present an experimental comparison of gas pressure sensors based on differently structured extrinsic Fabry-Pérot interferometers (FPIs). Different fabrication techniques were adopted to foster the practical realization of these sensors. A novel photonic crystal fiber (PCF) based FPI with an angle cleaved end face that enables gas to easily flow in and out of the cavity while also avoiding the mixed signal from the cascaded structure is also presented. We measured helium gas pressure from 0.1 MPa (atmospheric pressure) to 5 MPa at room temperature and obtained a gas pressure sensitivity coefficient of 0.5±0.01 nm/MPa. Furthermore, the gas pressure sensitivities are numerically analyzed to validate the experimental results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time measurement of parametric influences on the refractive index and length changes in silica optical fibers

In this paper, we present a simple cascaded Fabry-Perot interferometer (FPI) that can be used to measure in real-time the refractive index (RI) and length variation in silica optical fibers caused due to external physical parameters, such as temperature, strain, and radiation. As a proof-of-concept, we experimentally demonstrate real-time monitoring of temperature effects on the RI and length and measure the thermo-optic coefficient (TOC) and thermal expansion coefficient (TEC) by using the cascaded FPI within a temperature range of 21–486°C. The experimental results provide a TEC of 5.53 × 10 −7 /°C and TOC of 4.28 × 10 −6 /°C within the specified temperature range. Such a simple cascaded FPI structure will enable the design of optical sensors to correct for measurement errors by understanding the change in RI and length of optical fiber caused by environment parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A High-Temperature Multipoint Hydrogen Sensor Using an Intrinsic Fabry–Perot Interferometer in Optical Fiber

This paper presents a multiplexable fiber optic chemical sensor with the capability of monitoring hydrogen gas concentration at high temperatures up to 750 °C. The Pd-nanoparticle infused TiO 2 films coated on intrinsic Fabry–Perot interferometer (IFPI) array were used as sensory films. Strains induced upon exposure to hydrogen with varied concentrations can be monitored by IFPI sensors. The fiber sensor shows a repetitive and reversible response when exposed to a low level (1–6%) of hydrogen gas. Uniform sensory behavior across all the sensing cavities is demonstrated and reported in this paper.

47 OTHER INSTRUMENTATION↗

Active Compensation of Radiation Effects on Optical Fibers for Sensing Applications

Neutron and gamma irradiation is known to compact silica, resulting in macroscopic changes in refractive index (RI) and geometric structure. The change in RI and linear compaction in a radiation environment is caused by three well-known mechanisms: (i) radiation-induced attenuation (RIA), (ii) radiation-induced compaction (RIC), and (iii) radiation-induced emission (RIE). These macroscopic changes induce errors in monitoring physical parameters such as temperature, pressure, and strain in optical fiber-based sensors, which limit their application in radiation environments. We present a cascaded Fabry–Perot interferometer (FPI) technique to measure macroscopic properties, such as radiation-induced change in RI and length compaction in real time to actively account for sensor drift. The proposed cascaded FPI consists of two cavities: the first cavity is an air cavity, and the second is a silica cavity. The length compaction from the air cavity is used to deduce the RI change within the silica cavity. We utilize fast Fourier transform (FFT) algorithm and two bandpass filters for the signal extraction of each cavity. Inclusion of such a simple cascaded FPI structure will enable accurate determination of physical parameters under the test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-mode lasing in terahertz metasurface quantum-cascade VECSELs

To date, terahertz quantum-cascade vertical-external-cavity surface-emitting lasers (QC-VECSELs) have tended to oscillate in only one or two lasing modes at a time. This is due to the fact that the interaction between all of the longitudinal external cavity modes and the QC gain material is mediated through a single metasurface resonance, whose spatial overlap changes little with frequency; this suppresses spatial-hole-burning induced multi-mode operation. In this Letter, a VECSEL external cavity is demonstrated using an output coupler based upon a high-resistivity silicon etalon, which presents a periodic reflectance spectrum that is nearly matched with the external cavity mode spectrum. As the cavity length is varied, a systematic transition between a single/double-mode lasing regime and a multi-mode lasing regime is realized due to the Vernier effect. Up to nine modes lasing simultaneously with a free-spectral-range of approximately 21 GHz is demonstrated. Furthermore, this result provides a path toward the multi-mode operation necessary for eventual frequency comb operation.

47 OTHER INSTRUMENTATION↗

Considerations in upconversion: A practical guide to sum-frequency generation spectrometer design and implementation

Here, in this tutorial review, we discuss how the choice of upconversion pulse shape in broadband vibrational sum-frequency generation (SFG) spectrometer design impacts the chemical or physical insights one can obtain from a set of measurements. A time-domain picture of a vibrational coherence being mapped by a second optical field is described and the implications of how this mapping, or upconversion process, takes place are given in the context of several popular and emerging approaches found in the literature. Emphasis is placed on broadband frequency-domain measurements, where the choice of upconversion pulse enhances or limits the information contained in the SFG spectrum. We conclude with an outline for a flexible approach to SFG upconversion using pulse-shaping methods and a simple guide to design and optimize the associated instrumentation.

47 OTHER INSTRUMENTATION↗

Broadband Stability of the Habitable Zone Planet Finder Fabry–Pérot Etalon Calibration System: Evidence for Chromatic Variation

The comblike spectrum of a white light–illuminated Fabry–Pérot etalon can serve as a cost-effective and stable reference for precise Doppler measurements. Understanding the stability of these devices across their broad (hundreds of nanometers) spectral bandwidths is essential to realizing their full potential as Doppler calibrators. However, published descriptions remain limited to small bandwidths or short time spans. We present an ∼6 month broadband stability monitoring campaign of the Fabry–Pérot etalon system deployed with the near-infrared Habitable Zone Planet Finder (HPF) spectrograph. We monitor the wavelengths of each of ∼3500 resonant modes measured in HPF spectra of this Fabry–Pérot etalon (free spectral range = 30 GHz, bandwidth = 820–1280 nm), leveraging the accuracy and precision of an electro-optic frequency comb reference. These results reveal chromatic structure in the Fabry–Pérot mode locations and their evolution with time. We measure an average drift on the order of 2 cm s{sup –1} day{sup −1}, with local departures up to ±5 cm s{sup –1} day{sup −1}. We discuss these behaviors in the context of the Fabry–Pérot etalon mirror dispersion and other optical properties of the system and the implications for the use of similar systems for precise Doppler measurements. Our results show that this system supports the wavelength calibration of HPF at the ≲10 cm s{sup −1} level over a night and the ≲30 cm s{sup −1} level over ∼10 days. Our results also highlight the need for long-term and spectrally resolved study of similar systems that will be deployed to support Doppler measurement precision approaching ∼10 cm s{sup −1}.

42 ENGINEERING↗

Effect of Near-field Distribution on Transmission Characteristics of Fiber-fed Fabry–Perot Etalons

Fiber-fed etalons are widely employed in advanced interferometric instruments such as gravitational-wave detectors, ultrastable lasers and calibration reference for high-precision spectrographs. We demonstrate that variation in near-field distribution of the feeding fiber would deteriorate the spectrum precision of the fiber-fed Fabry–Perot etalon, especially when precision at the order of 3 × 10{sup -10} or higher is required. The octagonal fiber reinforced with double scrambler could greatly improve the steadiness and uniformness of the near-field distribution. When building wavelength calibrators for sub-m s{sup -1} precision radial-velocity instruments, the double scrambler should be considered meticulously.

47 OTHER INSTRUMENTATION↗