Search NASA⌕ Search

SEARCH · Search NASA

Results for “Facility effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Progress Towards the Validation of a new RELAP5-3D model of the High Temperature Test Facility

Validation is a key step in the development of any type of systems model. As the next generation of reactors approaches, the need for codes that have been validated for these new types of systems continues to grow. An example of a prominent option is the Reactor Excursion Leak Analysis Program (RELAP5-3D), developed by Idaho National Laboratory. This code was developed for the purpose of systems level thermal-hydraulic modeling of light water reactors (LWRS) and postulated transients that can occur in LWRS.RELAP5-3D has been substantially validated against LWR data. Due to its long history as a reactor safety analysis tool, there has been an effort to adapt RELAP5-3D for the purposes of advanced reactor concepts such as prismatic high-temperature gas-cooled reactors (HTGRs). However, RELAP5-3D has not nearly been validated and verified for HTGRs to the degree of LWRs, warranting verification and validation opportunities with computational benchmarks and existing experimental facilities. Examples of such facilities include the modular high-temperature gas-cooled reactor (MHTGR) 350 and the high temperature engineering test reactor (HTTR) from Japan. The MHTGR 350 is a benchmark design concept for code-to-code verification purposes; therefore, it does not provide any experimental data for validation opportunities The HTTR provides useful multiphysics validation data but does not have the in-core instruments to generate thermal-hydraulic experimental data to help with RELAP5-3D validation. Consequently, a facility that could provide key in-core temperatures for thermal-hydraulic validation was still needed. The High Temperature Test Facility (HTTF) is an integral effects facility for HTGR thermal hydraulics developed and operated by Oregon State University. HTTF represents ¼ length scale of the General Atomics MHTGR and is rated for a total power of 2.2 MW. Axially, the core consists of an upper and lower reflector and 10 blocks, numbered from bottom to top (Block 1 is right above lower reflector). The core is heated via graphite resistive heater rods, with respective channels distributed throughout the core. The primary coolant is helium and heat can radiate out of the core to the reactor cavity cooling system (RCCS), which is cooled by water. The primary purpose of the facility is to investigate pressurized conduction cooldown (PCC) and depressurized conduction cooldown (DCC) transients, which are also referred to as the pressurized and depressurized loss of forced cooling respectively. Two experiments were chosen to perform the validation study with a RELAP5-3D model of HTTF. These experiments are PG-27 (PCC) and PG-29 (DCC). These were chosen based off of the quality of available experimental data before and during the experiment which led to their inclusion in the HTGR Thermal Hydraulics Benchmark.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Finding a common ground for RCM experiments. Part B: Benchmark study on ethanol ignition

Rapid compression machines (RCMs) are widely used to investigate gas phase reaction kinetics of various kind of fuels at application relevant conditions. In principle, the operation of an RCM is based on the idea of compressing a homogenous pre-mixed fuel-air mixture by a piston. Usually creviced pistons ensure a homogenous adiabatic core in the center of the reaction chamber which permits the assumption of an isentropic relation between the measured pressure and gas temperature. Despite the ideal core gas compression, non-ideal effects such as heat loss, differences in the compression behavior, and ultimately non-standardized design and operation of rapid compression machines lead to different experimental results in different facilities at nominally the same end of compression conditions. In this study ignition delay times of ethanol are investigated at four different conditions in five independent RCMs. As expected, the raw results of the different facilities indeed show notable differences at the same end of compression conditions. However, according to the adiabatic core hypothesis the agreement between kinetic simulations and experiments should be consistent for all facilities provided that the facility effects are correctly accounted for. To elaborate upon this hypothesis, a kinetic mechanism is optimized to reflect the experimental results of all facilities. In the end, the optimized mechanism predicts all experimental data within the expected uncertainty. This confirms the reliability of RCM experiments for kinetic investigations and the validity of the effective volume approach in simulating RCM data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NLR HPC Facility Power Usage Effectiveness (PUE) Data

Timeseries of Energy Systems Integration Facility (ESIF) Data Center Power Usage Effectiveness (PUE) Data provided in Parquet and compressed CSV formats Power Metrics Timeseries Fields: ts: Timestamp cooling_kw: Cooling (kilowatts) - Captures the power used by fans and pipe trace heaters associated with outdoor cooling equipment. The dedicated tower filter pump power is also captured as cooling load. energy_reuse: Energy Reuse Effectiveness hvac_kw: Heating, ventilation, and air conditioning (kilowatts) - Captures fan walls, fan coils that support the data center electrical rooms, and the make-up air unit. it_power_kw: IT equipment (kilowatts) - Captures power used by the IT equipment on the data center floor. plug_and_light_kw: Lights and utility plugs (kilowatts) - Captures power associated with the data center and dedicated mechanical room. The crank-case heater for the emergency standby generator is also captured as light and plug load. pue: Power Usage Effectiveness pump_kw: Pumps (kilowatts) - Captures power from pumps that move water in the data center Energy Recover Water loop and the Tower Water loops, and also captures power used by the boost pumps that circulate water through the fan walls. Note: The tower filter pump runs constantly to filter water from the data center cooling tower system, so 2.67 kilowatts are attributed to this pump and that is not reflected in this data field. day: Day of month Outside Weather Station Timeseries Fields: ts: Timestamp outside_air_humidity: Outside air humidity - Relative humidity percent outside_air_temp: Outside air temperature - Degrees Fahrenheit day: Day of month More detail: High-Performance Computing Data Center Power Usage Effectiveness

97 MATHEMATICS AND COMPUTING↗

Biorefinery siting and sizing to achieve the US Billion‐Ton Bioeconomy vision: A case study using a gasification–Fischer–Tropsch process

Achieving a secure, abundant, and affordable energy future requires a robust and adaptable energy strategy, with bioenergy playing a pivotal role. Biomass-based energy presents a promising pathway to use domestic resources while fostering economic opportunities in rural areas. Despite the potential to source more than 1 billion dry short tons of biomass annually in the US, significant infrastructure and economic barriers hinder full utilization for energy production. This study used the Biofuel Infrastructure, Logistics, and Transportation (BILT) model to assess biorefinery siting and scale and determine the number and size of facilities required to maximize use of the US biomass potential. A spatially agnostic approach first assessed the effects of facility capacity and transportation constraints on biomass use. Then, a spatially explicit analysis integrated county-level biomass availability from the US Department of Energy's 2023 Billion-Ton Report and technoeconomic assessments to evaluate different biorefinery deployment scenarios. The results indicate that an optimized mix of facility sizes is essential to leverage biomass resources fully across varying regional production densities to maximize use of the US biomass potential. Larger biorefineries or co-located smaller facilities significantly enhance biomass use while reducing costs through economies of scale. These findings underscore the importance of strategically balancing facility capacity and spatial distribution to optimize the bioenergy supply chain. In conclusion, this study provides critical insights for advancing the US bioenergy economy by aligning biorefinery deployment with biomass resource availability and economic viability.

BILT Model↗

Methodology For Determining The Effective Aircraft Impact Area For Irregularly Shaped Facilities

This report presents a computational methodology for determining the effective aircraft impact area for irregularly shaped facilities, extending the approach in Department of Energy (DOE) Standard 3014 by decomposing “critical areas” into multiple rectangular nodes rather than relying on a single bounding cuboid. This method reduces unnecessary conservatism that can arise when non-critical space is enveloped by a single footprint. The facility’s critical areas are partitioned into nodes of constant height, a baseline aircraft impact trajectory is established, and the facility perspective is rotated to accommodate arbitrary heading angles. For each node, analytic expressions are provided to construct the node-specific effective impact polygon that accounts for skid distance, structural footprint, fly-in (shadow) region driven by building height and descent angle, and wingspan offsets capturing wing-only strikes.

42 ENGINEERING↗

Revealing the potential of nickel zinc ferrite: Facile synthesis and cost-effective anode for lithium-ion batteries

The increasing demand for lithium-ion batteries (LIBs) underscores the need for cost-effective alternative anode materials to ensure efficient Li-ion storage, given their pivotal role in various industries. This research focuses on the facile synthesis of nickel zinc ferrite (NZFO: Ni 0.65 Zn 0.35 Fe 2 O 4 ) and conducts comprehensive electrochemical analyses to evaluate its potential as a high-capacity alternative anode material for LIBs. The NZFO-CMR [sodium carboxymethyl cellulose (2%) and styrene-butadiene rubber (1%)] exhibited an initial delithiated capacity of ∼1232 mA h g −1 and maintained a stable capacity of around 358 mA h g −1 , along with an average Coulombic efficiency of 99.6% over 200 cycles. Cyclic voltammetry analysis revealed that Li-ion insertion was predominantly governed by ion diffusion, and the consistent correlation observed in electrochemical impedance spectroscopy spectra indicated stable electrochemical behavior throughout cycling. The facile synthesis approach and reasonable electrochemical performance of NZFO suggest its potential as an alternative anode material for advancing LIB's technology.

25 ENERGY STORAGE↗

RELAP5-3D validation studies based on the High Temperature Test facility

In the spring and summer of 2019, experiments were conducted at the High Temperature Test Facility (HTTF) that form the basis of an upcoming high-temperature gas-cooled reactor (HTGR) thermal hydraulics (T/H) benchmark. HTTF is an integral effects test facility for HTGR T/H modeling validation. This paper presents RELAP5-3D models of two of those experiments: PG-27, a pressurized conduction cooldown (PCC); and PG-29, a depressurized conduction cooldown (DCC). These models used the RELAP5-3D model of HTTF originally developed by Paul Bayless as a starting point. The sensitivity analysis and uncertainty quantification code, RAVEN was used to perform calibration studies for the steady-state portion of PG-27. Here we developed four PG-27 calibrations based on steady-state conditions. These calibrations all used an effective thermal conductivity equal to 36 % of the measured thermal conductivity, but they differed with respect to the frictional pressure drops and radial conduction models. These models all captured the trends in steady-state temperature distributions and transient temperature behavior well. All four calibrations show room for improvement in predicting the transient temperature rise. The smallest error in temperature rise during the transient was a 21 % underprediction, and the largest was a 48 % underprediction. The errors in transient temperature rise are largely a result of a mismatch in power density between the RELAP5-3D model and the experiment due to the location of active heater rods along the boundary between heat structures in the model. The best of these calibrations was applied to PG-29 to model the DCC. Once again, temperatures during the transient were underpredicted but trends in temperature were captured. The RELAP5-3D model captured trends in the data but could not reproduce measured temperatures exactly. This result is not attributed to deficiencies in the experimental data or to RELAP5–3D itself. Rather, this result likely arises due to the some of the assumptions and decisions made when the RELAP5-3D model was first developed, prior to the execution of HTTF experiments. An agreement in prediction of temperature trends but challenges reproducing HTTF temperatures within measurement uncertainty is consistent with previous analyses of HTTF in the literature. Future RELAP5-3D validation activities centered around HTTF may be able to provide greater insight into the code’s capabilities for HTGR modeling with a more finely nodalized model.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Scaling methodologies and similarity analysis for thermal hydraulics test facility development for water-cooled small modular reactor

Small modular reactors (SMRs) represent a promising option for providing clean and sustainable energy due to their potential for enhanced safety, reduced capital costs, and increased siting flexibility. However, new reactor systems require the development and operation of representative scaled-down test facilities to support the verification and validation of system computer codes and models. Here this study reviews the research on scaling methodologies and similarity principles pivotal in developing non-nuclear integral effects test and separate effects test facilities for water-cooled SMRs. The study focuses on a review of the scaling methods, similarity approaches, and possible challenges posed by the unique and compact design features of integral-pressurized water reactor-type SMRs, and their representative test facilities. This study also reviews previous research related to scaling and similarity methodologies and provides insights into design considerations for achieving prototypic conditions in test facilities. The findings and recommendations emphasize the broader impact of appropriate scaling and similarity principles to ensure meaningful and transferable results from non-nuclear test facilities to accelerate the safe and efficient deployment of next-generation water-cooled SMRs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reducing Non-Radiative Recombination in Perovskite Solar Cells with a SiO2-Graphene Oxide Buried Interface Layer

Perovskite solar cells (PSCs) have emerged as a transformative photovoltaic technology. However, the device performance of inverted PSCs is dramatically limited by surface defects and the underlying film morphology of metal halide perovskite (MHP) thin film. Herein, we report a novel buried interface layer consisting of SiO2 nanoparticles (NPs) chemically bonded to graphene oxide (GO), deposited atop a hydrophobic hole extraction layer (HEL) to address this limitation. The SiO2 NPs serve as insoluble scaffolds that immobilize GO sheets on the hydrophobic HEL surface, enabling the formation of homogeneous MHP thin films. Meanwhile, the GO functional groups interact with surface-uncoordinated Pb2+, suppressing interfacial defects and guiding crystal grain growth of the resultant MHP thin films. This synergistic effect suppresses non-radiative charge recombination and enhances charge extraction efficiency. As a result, a 26.07% efficiency with significantly suppressed photocurrent hysteresis is observed from PSCs incorporating the SiO2-GO buried interface layer. Moreover, the above PSCs maintain 92% of their initial PCE after 1800 h of continuous operation at the maximum power point under AM 1.5 G (100 mW/cm2) illumination at 25 degrees C in air with 50-60% relative humidity. These results demonstrate that we have developed a facile and effective way to realize high-performance inverted PSCs.

14 SOLAR ENERGY↗

Reduction of Porosity in Cementitious Waste Forms to Reduce Effective Diffusivity

Although current practices meet regulations for grout waste forms, development of sequestration materials and techniques for contaminants of concern could expand the use of grout waste forms and reduce risk to established processes from future compositional changes. There are contaminants in waste streams that are not permanently and completely sequestered in current grout waste forms under certain conditions. These contaminants include methyl mercury, 129 I, 99 Tc, and nitrate. Each of these species have minor fractions that are not permanently and completely isolated from the environment and therefore potentially contribute to long-term environmental impacts. An approach of interest includes the technique of reducing porosity to result in reduced leachability of all contaminants simultaneously. The current Savannah River Site (SRS) saltstone formulation was used to evaluate the relationship between leachability and porosity reduced waste forms by altering the water-to-binder ratio. Results indicated decreasing the water-to-binder directly reduced porosity and resulted in the waste form’s ability to more effectively immobilize nitrate. This work was funded by the Department of Energy Office of Environmental Management (DOE-EM) Technology Operations Office (TOO) Project # HQ221818.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Engineering self-deliverable ribonucleoproteins for genome editing in the brain

The delivery of CRISPR ribonucleoproteins (RNPs) for genome editing in vitro and in vivo has important advantages over other delivery methods, including reduced off-target and immunogenic effects. However, effective delivery of RNPs remains challenging in certain cell types due to low efficiency and cell toxicity. To address these issues, we engineer self-deliverable RNPs that can promote efficient cellular uptake and carry out robust genome editing without the need for helper materials or biomolecules. Screening of cell-penetrating peptides (CPPs) fused to CRISPR-Cas9 protein identifies potent constructs capable of efficient genome editing of neural progenitor cells. Further engineering of these fusion proteins establishes a C-terminal Cas9 fusion with three copies of A22p, a peptide derived from human semaphorin-3a, that exhibits substantially improved editing efficacy compared to other constructs. We find that self-deliverable Cas9 RNPs generate robust genome edits in clinically relevant genes when injected directly into the mouse striatum. Overall, self-deliverable Cas9 proteins provide a facile and effective platform for genome editing in vitro and in vivo.

59 BASIC BIOLOGICAL SCIENCES↗

Facile Strategy to Prepare Poly(ionic liquid)-Coated Solid Polymer Electrolytes through Layer-by-Layer Assembly

The inability of solid polymer electrolytes to preserve strong mechanical strength with high ionic conductivity hinders the commercialization of lithium metal batteries (LMBs). The success of fabricating layer-by-layer (LbL)-assembled electrolytes has realized the application of flexible solid polymer electrolytes in electrochemical devices. Here, we demonstrate a rational strategy to construct solid electrolytes coated with multiple ultrathin layers of polyanions (poly(sodium 4-styrenesulfonate)) and polycations (linear poly(1-butyl-3-(4-vinylbenzyl)-1H-imidazolium chloride) (BVIC)/linear poly(PEG 4 -VIC)/SiO 2 -g-poly(PEG 4 -VIC)) using an LbL assembly method. Poly(ionic liquid) backbones and PEG side groups are employed to facilitate the transport of lithium ions via the segmental motion of the macromolecular matrix. The fabricated free-standing membranes exhibited good ionic conductivities of 9.03–10 × 10 –4 S cm –1 . Furthermore, a Li/LiFePO 4 cell assembled with the LbL-membrane electrolytes exhibits an initial high discharge capacity of 143–158 mAhg –1 at 60 °C with high columbic efficiency. In conclusion, this approach, which combines polymer synthesis and LbL self-assembly, is an effective and facile route to fabricate solid polymer electrolyte membranes with superior ionic conductivity and mechanical robustness, which are useful for electrochemical devices and high-voltage battery applications.

25 ENERGY STORAGE↗

Load-Shifting Strategies for Cost-Effective Emission Reductions at Wastewater Facilities

Significant hourly variation in the carbon intensity of electricity supplied to wastewater facilities introduces an opportunity to lower emissions by shifting the timing of their energy demand. This shift could be accomplished by storing wastewater, biogas from sludge digestion, or electricity from on-site biogas generation. However, the life cycle emissions and cost implications of these options are not clear. Here, we present a multiobjective optimization framework for comparing cost- and emission-minimizing load-shifting strategies at a California case study facility with a relatively low carbon intensity grid and high spread in peak and off-peak electricity prices. We evaluate cost and emission trade-offs from the optimal flexible operation of both existing infrastructure and optimally sized energy flexibility upgrades. We estimate energy-related emission reductions of up to 9.0% with flexible operation of existing infrastructure and up to 16.8% with optimally sized storage upgrades. Only a fraction of these potential savings are realized under actual industrial energy tariffs and the EPA’s recommended social cost of carbon. Energy flexibility may hold promise as a short-term emission-saving solution for the wastewater sector, but the extent of savings is heavily dependent on the cost of carbon, electricity tariffs, and emission intensity of the regional electricity grid.

climate↗

Causal Directions Matter: How Environmental Factors Drive Convective Cloud Detrainment Heights

This study investigates how environmental factors influence the level of maximum detrainment (LMD) in deep convective clouds. Through a novel application of the Linear Non‐Gaussian Acyclic Model (LiNGAM), we discover causal structures between environmental variables and LMD, observed at six tropical sites operated by the Atmospheric Radiation Measurement (ARM) user facility. LiNGAM effectively identifies causal directions among variables of interest, revealing robust relationships such as those among the lifting condensation level (LCL), level of free convection (LFC), and convective inhibition (CIN), aligning with prior knowledge. Relative humidity is shown to directly influence LMD; however, this relationship exhibits strong nonlinearity and becomes difficult to detect when the contrast between oceanic and continental environments is excluded from the analysis. This study highlights the importance of establishing causal relationships before performing statistical inference.

54 ENVIRONMENTAL SCIENCES↗

Micro-segregation phenomena and related spectroscopic signals in melt-grown β-Ga2O3 single crystals

One of the primary advantages of β-Ga2O3 over incumbent wide bandgap semiconductors is the ability to grow directly from the melt. Melt growth, using Czochralski or similar methods, results in impurities in the crystal which originate from the crucible, such as iridium and other transition metals like chromium. These impurities exhibit optoelectronic signatures useful for their identification and sensitive to the Fermi energy of a given crystal (i.e., signatures vary with the electrical conductivity of the matrix). In this work, we describe how laser Raman systems can be used to map and spatially correlate Cr3+ photoluminescence, electronic-coupled Raman scattering from Ir4+d–d internal transitions, and the Raman line attributed to hydrogenic shallow donors. Laser ablation inductively coupled plasma mass spectrometry directly measured spatially dependent relative metal concentrations and confirmed spectroscopic signals resulting from heterogeneities in impurity concentrations in β-Ga2O3 boules. Mapping of photoluminescence and Raman-related signatures is, thus, demonstrated as an effective and facile method for spatial measurement of chemical heterogeneities in both insulating and conductive melt-grown β-Ga2O3 crystals.

Dutton, Benjamin L. (ORCID:000000031272130X)↗

Analysis of AP1000 Small-Break Loss-of-Coolant Accident Using Reactor Transient Simulator

The Westinghouse Electric Company’s Advanced Passive Reactor (AP1000) is characterized by the incorporation of passive safety systems (PSSs) designed to ensure core cooling during transient events. The assessment of PSSs requires evaluation of their performance through a combination of experiments and simulations employing various thermal-hydraulic codes. In addition, detailed evaluation of PSSs for a specific reactor system transient analysis such as loss-of-coolant-accident analysis supports understanding representative integral effects test facility development and the further evolution model development and assessment process. Developing a reactor system code is a complex and time-consuming process that requires significant engineering expertise and effort. It can take several months to even years to complete in the early stages of reactor system design and analysis. However, this process can be expedited through the use of transient simulator models for similar reactor systems, which can be used for lesson learning and training purposes. This study uses the Personal Computer Transient Analyzer (PCTRAN) code. The main advantage of PCTRAN is its ease of use and ability to run faster than real time. This study presents the results obtained for a small-break loss-of-coolant accident (SBLOCA) for two breaks using the full version (licensed) of PCTRAN. The purpose of this investigation is to evaluate the overall system behavior during the postulated SBLOCA event as well as assess the capability of the PCTRAN code to reproduce the system response during transient events. The obtained results were compared with the Westinghouse NOTRUMP system code. The PCTRAN code proved to be reliable in predicting the qualitative behavior of the system in both transient cases. As for the system response, it was found that it is contingent on the activation time of the PSSs. The differences in reactor coolant system pressure between the two codes were attributed to the critical flow model and simplification of mass and energy balance. Despite PCTRAN’s limitations, it can still provide a reasonable prediction of various reactor parameters such as pressure, mass flow rate, and void fraction during a SBLOCA scenario. It is worth noting that PCTRAN currently employs a bulk approach similar to that of the Modular Accident Analysis Program (MAAP) and MELCOR codes. However, the upcoming version of PCTRAN will include an artificial intelligence–based detection and accident prevention system, as well as different models for different reactor components. Consequently, PCTRAN has the potential to be upgraded to match the system thermal-hydraulic codes of the U.S. Nuclear Regulatory Commission and become more widely used in cybersecurity to safeguard nuclear power plants from cyberattacks.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗