Search NASASearch

SEARCH · Search NASA

Results for “Failure Rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Facilitating Data Collection of Maintenance Events to Populate the Hydrogen Component Reliability Database (HyCReD)

The Hydrogen Component Reliability Database (HyCReD) is a collaborative project between the National Renewable Energy Laboratory, the University of Maryland, and hydrogen stakeholders to improve safety and reliability for hydrogen facilities by implementing component reliability data taxonomies that support hydrogen infrastructure failure rate analysis. The project aims to quantify failure rates of hydrogen components through high-quality data collection and analysis on root causes and maintenance needed. HyCReD provides a common database for cataloging hydrogen component failures which exists for reliability research in many other mature industries [2]. The database fills a gap for the hydrogen community by providing a scientifically rigorous approach to quantitative risk assessment (QRA), prognostic health management (PHM), and reliability-centered maintenance (RCM) analysis. High level results will be aggregated and anonymized to protect company sensitive information; detailed results will be used to help address issues of hydrogen components. These advanced analytics will support accelerated deployment of hydrogen infrastructure by enabling better: design and safety of projects (safety codes and standards development), infrastructure reliability and cost (component failure rates, maintenance protocols), and component R&D needs (robust supply chain). A key to a successful HyCReD implementation is facilitating the ease of reporting and data quality in the database that can be used for analysis. Maintenance data was a previously identified gap in initial efforts to populate and validate the database taxonomies [3]. Collection of maintenance data will be instrumental in identifying failure modes and rates, identifying incipient component failures or reduced performance, cataloging best practices for maintenance routines and methods for prognostic health management, and quantifying the risk and effect of different failure modes. Several key priorities are identified for streamlined data collection to achieve quality and detailed failure data: Applicability, Ease of Use, Accessibility, and Information Security. The HyCReD team has now begun deployment of the database to several companies and groups that have signed non-disclosure agreements to facilitate the data collection of failures in industry hydrogen refueling station infrastructure. This paper will provide an update into the process of HyCReD deployment including the development of a coding guide for facility personnel to reference and ensure data quality and consistency from one station to another as well as implementation of contextually dependent data fields of system taxonomy and formatted entries to provide ease of use. The goal is to communicate the lessons learned from the roll-out to technicians and engineers in the field, and the addition of need for high level of security to protect all stakeholders.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Correlation Between Weather Alerts and Grid Component Failures for Grid Alert

Weather events cause most grid failures. Often, we even get notifications on our phones to take cover or be prepared for an imminent event. If electric grid utilities had a similar warning that also included probable scenarios and the equipment involved, they could prepare and minimize the effects. Recent research at Idaho National Laboratory into electric grid risk analysis methods resulted in a tool that allows for the development of the most likely scenarios given failure probabilities of grid components. INL has a project with the U.S. Department of Energy’s Cybersecurity, Energy Security, and Emergency Response (CESER) program to develop a Grid Alert application that receives messages from the existing emergency alert system, filters and determines components possibly affected by the emergency event, calculates probable scenarios uses MASTERRI and then notifies the utility if there is significant risk. Historical failure data of elements that comprise the U.S. electric grid have been compiled by utilities and organizations such as the international regulatory body North American Electric Reliability Corporation (NERC). Nominal failure rates are obtained from this data. To make this tool possible, estimated failure rates are needed for different component types given the alert type, severity, and location. Historic weather-related grid element failures are correlated with historic weather events from Integrated Public Alert & Warning System (IPAWS). These correlated events and failures are used along with Bayesian updates from the historical norms to provide a modified failure rate for grid elements in the alert areas and calculate probable scenarios. This discusses the Grid Alert project plan but focuses on the data gathered and process used in determining failure rates for possible grid failure scenarios.

24 - POWER TRANSMISSION AND DISTRIBUTION

Natural Hazard Forecast Alert Grid Risk System

Weather events cause most power outages. Often, we even get notifications on our phones to take cover or be prepared for an imminent event. If electric grid utilities had a similar warning that also included probable scenarios and the equipment involved, they could prepare and minimize the effects. Idaho National Laboratory had a project with the U.S. Department of Energy’s Cybersecurity, Energy Security, and Emergency Response program to develop a grid alert application that receives messages from the existing emergency alert system, filters and determines components possibly affected by the emergency event, calculates probable scenarios using MASTERRI (Modeling And Simulation for Targeted Reliability and Resilience Improvement). For high-risk events, the application can then send alert links to subscribed electric distribution utility operations staff to allow them to see and evaluate the scenarios and the impact in a web based interactive map tool. This proof of concept application used data from utilities and organizations, such as the international regulatory body North American Electric Reliability Corporation, which have complied historical failure data of elements that comprise the U.S. electric grid. Nominal failure rates are obtained from this data. To make this tool possible, estimated failure rates were calculated for different component types given the alert type, severity, and location. Historic weather-related grid element failures were correlated with historic weather events from the Integrated Public Alert & Warning System. These correlated events and failures are used along with Bayesian updates from the historical norms to provide a modified failure rate for grid elements in the alert areas and calculate probable scenarios. Working with an industry collaborator, actual grid models and data were used for demonstration cases. This report outlines the work performed for this project.

24 - POWER TRANSMISSION AND DISTRIBUTION

Solar Photovoltaic (PV) Damage Assessment After Typhoon Mawar: Findings and Recommendations for Resilient PV on Guam

A team from the National Renewable Energy Laboratory (NREL) visited Guam in August 2023 to assess failure modes of solar photovoltaic (PV) systems after Typhoon Mawar and to provide recommendations to increase the resilience of PV systems on Guam. The team visited 30 systems: commercial and utility scale, and rooftop and ground-mounted. The team observed systems with no apparent damage, as well as systems that were completely lost. Systems fared very well overall. The average failure rate of rooftop systems was 18%, with a median failure rate of 2%, meaning the few systems that suffered total loss pulled up the average. Only eight 8 of the 25 rooftop systems suffered more than 5% damage. All ground-mounted systems suffered less than 0.5% damage, aside from a carport that lost 16% of its modules. PV systems at Andersen Air Force Base suffered 5% damage on average, with a median system failure of 0.6%. In almost all cases, failures were the result of: (1) Inadequate clamping of the module frame to the mount, (2) Module mounting clamps rotating out of underlying support rail (i.e., T-bolt that rotates free at less than 60 degrees of rotation), (3) An object hitting the panel resulting in a fracture, and in some cases leading to a cascading failure of several more panels, and (4) Excessive tilt angle (in Guam, greater than 5 degrees can be a risk due to wind speed, and power production trade-offs are insignificant).

14 SOLAR ENERGY

Rare events and Griffiths phases in topological quantum error correction

The performance of quantum error correcting (QEC) codes is often studied under the assumption of spatiotemporally uniform error rates. On the other hand, experimental implementations almost always produce heterogeneous error rates, in either space or time, as a result of effects such as imperfect fabrication and/or cosmic rays. It is therefore important to understand if and how their presence can affect the performance of QEC in qualitative ways. Here, in this work, we study the effects of nonuniform error rates in the representative examples of the 1D repetition code and the 2D toric code, focusing on when they have extended spatiotemporal correlations; these may arise, for instance, from rare events (such as cosmic rays) that temporarily elevate error rates over the entire code patch. These effects can be described in the corresponding statistical mechanics models for decoding, where long-range correlations in the error rates lead to extended rare regions of weaker coupling. For the 1D repetition code where the rare regions are linear, we find two distinct decodable phases: a conventional ordered phase in which logical failure rates decay exponentially with the code distance, and a rare-region dominated Griffiths phase in which failure rates are parametrically larger and decay as a stretched exponential. In particular, the latter phase is present when the error rates in the rare regions are above the bulk threshold. For the 2D toric code where the rare regions are planar, we find no decodable Griffiths phase: rare events which boost error rates above the bulk threshold lead to an asymptotic loss of threshold and failure to decode. Unpacking the failure mechanism implies that techniques for suppressing extended sequences of repeated rare events (which, without intervention, will be statistically present with high probability) will be crucial for QEC with the toric code.

classical statistical mechanics

Hierarchical memories: Simulating quantum LDPC codes with local gates

Constant-rate low-density parity-check (LDPC) codes are promising candidates for constructing efficient fault-tolerant quantum memories. However, if physical gates are subject to geometric-locality constraints, it becomes challenging to realize these codes. In this paper, we construct a new family of [[N,K,D]] codes, referred to as hierarchical codes, that encode a number of logical qubits K=Ω(N/log(N) 2 ). The N th element of this code family is obtained by concatenating a constant-rate quantum LDPC code with a surface code; nearest-neighbor gates in two dimensions are sufficient to implement the corresponding syndrome-extraction circuit and achieve a threshold. Below threshold the logical failure rate vanishes superpolynomially as a function of the distance D(N). We present a bilayer architecture for implementing the syndrome-extraction circuit, and estimate the logical failure rate for this architecture. Under conservative assumptions, we find that the hierarchical code outperforms the basic encoding where all logical qubits are encoded in the surface code.

Pattison, Christopher A. [California Institute of

Surf-Deformer: Mitigating Dynamic Defects on Surface Code via Adaptive Deformation

In this paper, we introduce Surf-Deformer, a code deformation framework that seamlessly integrates adaptive defect mitigation functionality into the current surface code workflow. It crafts several basic deformation instructions based on fundamental gauge transformations, which can be combined to explore a larger design space than previous methods. This enables more optimized deformation processes tailored to specific defect situations, restoring the QEC capability of deformed codes more efficiently with minimal qubit resources. Additionally, we design an adaptive code layout that accommodates our defect mitigation strategy while ensuring efficient execution of logical operations. Our evaluation shows that Surf-Deformer outperforms previous methods by significantly reducing the end-to-end failure rate of various quantum programs by 35× to 70×, while requiring only about 50% of the qubit resources compared to the previous method to achieve the same level of failure rate. Ablation studies show that Surf-Deformer surpasses previous defect removal methods in preserving QEC capability and facilitates surface code communication by achieving nearly optimal throughput.

Yin, Keyi

Impacts of PV Module Connector Failures on Cost and Performance of Utility Scale Photovoltaic Systems

The reliability, cost and performance of electrical connectors are a concern in all types of electrical systems, and demands on connectors used on photovoltaic (PV) systems include that connectors maintain electrical conductivity and physical strength, endure ultraviolet sunlight and high ambient temperature, and resist moisture and chemical intrusion over a very long (>25 year) performance period. Connector failures increase operation and maintenance (O&M) costs and reduce plant production, but connector failure can also cause safety and liability problems, which are of greater concern. This work results from a three-year collaboration between Sandia National Laboratories (SNL), the Electric Power Research Institute (EPRI), and the National Renewable Energy Laboratory (NREL) and funded by the U.S. Department of Energy (DOE) Solar Energy Technology Office (SETO) under Agreements #39035 and #38531 "Connector Reliability Across the US Solar Sector." a multi-pronged investigation of PV connector health across the US (see https://energy.sandia.gov/pvconnectors/). This report presents derivation of a Techno-Economic Analysis (TEA) that models failure modes and frequencies (how often failure occurs), estimates O&M costs and lost production associated with connector failures, and then calculates the effect that PV module connectors can have on Levelized Cost of Energy (LCOE). The model is informed with initial data from quantitative assessment of failure rates, root causes and mechanisms, in-situ diagnostics and data collection, lab-based forensics, and interviews with PV connector manufacturers and plant operators. SNL conducted site inspections at multiple utility-scale sites in different climates and subjected field samples of new, used, and degraded connectors to visual and electrical characterization. EPRI conducted metallurgical analysis of the pin and sleeve conductors to study failure-induced morphological and compositional changes. There is in general a shortage of statistically valid data, but data from PVROM database maintained by SNL was sufficient to ascertain failure rates and lost production as well as provide qualitative insight in its curated maintenance records. This report details the structure of the mathematical model but the sources of data to inform the model will continue to evolve. Analysis of a 100 MW PV plant is provided as an example of the use of the model, with results indicating that connectors are responsible for Annualized O&M Costs of $\$$71,933/year; Annualized Unit O&M Costs of $\$$0.72/kW/year; that a Reserve Account of $\$$187,220 should be available to fund repairs related to connectors; that connectors add $\$$1,494,004 to the Net Present Value of the O&M Costs (project life); and that O&M related to connectors adds about $\$$0.00088/kWh to the Levelized Cost of Energy. The impact of this model is to provide a tool to make the US solar sector more robust by quantifying and monetizing the reliability risks to utility-scale PV systems posed by poorly installed, mismatched and/or poorly designed and manufactured connectors. The TEA provides a model incorporating failure statistics, O&M cost data, and lost production into a single figure of merit, informing decisions and enabling practitioners to optimize cost and performance trade-offs. Stakeholders include connector manufacturers, system designers and equipment specifiers, standards bodies, installers and O&M providers, investors and insurance underwriters. This report supports continued growth of PV predicated on assurances that properly installed and maintained PV system connectors are safe and reliable. The project team is proposing future work including accelerated testing of connectors and expanding the approach taken here to other PV system components, such as TEA for rapid shut-down devices.

14 SOLAR ENERGY

Management of Risks Associated with Application of Novel Materials in Novel Operating Environments in Novel Reactor Designs

There is currently no widely agreed, detailed general method for licensing a novel plant incorporating novel materials (or materials being deployed in novel environments); in many such situations, there are no directly applicable engineering code cases for decision-makers (including regulators) to rely on. This paper discusses a framework for solving this problem that is based on the Reliability and Integrity Management (RIM) approach delineated in ASME BPVC Section XI Division 2. NRC Regulatory Guide 1.246, Rev. 0, endorses, with conditions, the subject portion of the ASME Code. The proposed framework is meant to support development of a licensing case by addressing certain technical challenges. The framework discussed here is compatible with the Licensing Modernization Project, but applying it in a specific case will call for advances in the state of practice, if not the state of the art. The RIM approach calls for applicants to (a) allocate reliability targets to plant structures, systems, and components (SSCs), (b) show that they are able to relate the currently observed physical condition of each SSC in the program to its failure probability well enough to determine whether the target reliability allocations are being satisfied, allowing for uncertainty related to the novelty of the materials/designs/operating environments, and (c) be able to demonstrate that the proposed program of surveillances will reliably detect unacceptable degradation of an SSC before SSC failure occurs. These challenges are discussed in the paper, and a potentially applicable modeling approach based on cumulative damage rather than failure rates is briefly illustrated.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Modeling the PV System Level Economic Impact of PV Connector Failure Modes

Photovoltaic (PV) connectors must maintain mechanical integrity for over 25 years while operating under UV exposure, elevated temperature, and mechanical loading. Connector degradation increases with electrical resistance, leading to energy losses, unplanned downtime, and higher operation and maintenance (O&M) costs and in severe cases, safety risks from overhearing or arcing. Connector related failures remain among the most frequent causes of disruption in utility-scale PV (UPV) systems, yet their lifetime economic impacts are poorly quantified. This work presents a techno-economic analysis (TEA) framework that links identified connector failure modes to system level energy losses and lifetime cost impacts using identified resistance measurements and failure rates from 6,2761 PV connectors inspected. Connector failures increase system level O&M costs, raising LCOE by roughly 5%. Downtime driven availability losses dominate economic impact. Resistance-driven I2R and IV-curve losses are secondary, but remain non-negligible. Thermal damage, bend-radius violations, and loose connections drive the majority of LCOE uplift Improving connector reliability through better installation quality, inspection, and design can meaningfully reduce lost energy, O&M costs, and LCOE.

14 SOLAR ENERGY

Enhanced Component Performance Study: Motor-Operated Valves 1998-2024

This report presents an enhanced performance evaluation of motor-operated valves (MOVs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2024 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The MOV failure modes considered are fail to open or close (FTOC), fail to operate or control (FTOP), and spurious operation (SO). The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. The following increasing trend was identified for MOVs for the most recent 10-year period: • Low-demand MOV frequency of FTOC demands (demands per reactor year). The following decreasing trends were identified for MOVs for the most recent 10-year period: • Low-demand MOV FTOC failure probability • High-demand MOV SO failure rate • Low-demand MOV frequency of FTOC events (failures per reactor year) • High-demand MOV frequency of SO events (failures per reactor year).

22 GENERAL STUDIES OF NUCLEAR REACTORS

Deconsolidation and Leach Burn Leach of Seven As Irradiated AGR 5/6/7 TRISO Fuel Compacts from Capsules 2, 3, 4, and 5

Seven as-irradiated Advanced Gas Reactor (AGR) 5/6/7 compacts underwent destructive post-irradiation examination via deconsolidation-leach-burn leach at Idaho National Laboratory (INL). The selection of the compacts extended the upper and lower limits of time-average volume-average (TAVA) temperature for compacts that had gone through deconsolidation-leach-burn leach so far. The measured inventories of fission products and actinides in the compact matrix and outer pyrolytic carbon were reported. Results indicated unexpectedly higher rates of fuel kernel leaching compared to compacts from AGR-1 and AGR-2. These failure rates were attributed to damage during post-irradiation sample handling, rather than irradiation itself. AGR-5/6/7 compacts have little or no matrix coverage for some particles at the top and bottom ends of cylindrical fuel compacts, making them more fragile. Sixty particles were randomly sampled from each compact, and the gamma results were reported. Three SiC shells from were identified, one of which showed signs of chemical attack in the high-irradiation temperature compact.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Effect of Transverse Compression on the Dielectric Breakdown of Power Cable with Ethylene Propylene Rubber Insulation

Understanding of the failure mechanisms of submarine dynamic power cables (SDPC) is critical for innovative design to meet the 2035 cost reduction target of U.S. DOE Floating Offshore Wind Shot. This is important because the current design suffers a significant failure rate in the field. This project explored a multiphysics approach and conducted systematic electro-thermo-mechanical (ETM) experimental study on the power cores extracted from a 15 kV power cable. The power cable had three cores of copper conductor and ethylene propylene rubber (EPR) insulation. An ETM testing system with transverse compression capability was developed. Mechanical loading induced dielectric breakdown. Increasing temperature from room temperature (RT, 22 degrees Celsius) to 90 degrees Celsius resulted in the 67% decrease in the failure mechanical load as defined by the dielectric breakdown. With the same temperature rise, the creep mechanical load was reduced by 70% at a given dielectric breakdown time. The post-test measurement revealed an impressive recovery of electrical resistance, although the dielectric breakdown occurred in the ETM test that would not be captured without the use of ETM testing.

Wang, Hong [ORNL] (ORCID:0000000201730545)

Electro-Thermo-Mechanical (ETM) Study on Submarine Dynamic Power Cables (SDPC) for Offshore Wind Transmission

Understanding the failure mechanisms of submarine dynamic power cables (SDPC) is critical for innovative design to meet the 2035 cost reduction target of U.S. DOE Floating Offshore Wind Shot. This is important because the current design suffers a significant failure rate in the field. This project conducted a systematic electro-thermo-mechanical (ETM) experimental study on the power cores extracted from a 15kV power cable with three cores of copper conductor, ethylene propylene rubber (EPR) insulation, and continuously corrugated welded aluminum armor (CCWA). An ETM testing system was developed by integrating a high voltage (HV) amplifier, two ceramic heaters, and a rod-plate transverse compression setup into a mechanical testing machine. Increasing temperature from room temperature (RT, 22 degree C) to 90 degree C resulted in the 67% decrease in the failure mechanical load as defined by the dielectric breakdown. Under creep mechanical loading, the dielectric breakdown time was decreased by 70% for a given mechanical load when the specimen temperature increased from RT to 90oC. The failure strain in both monotonic and creep mechanical loading modes was related to the maximum mechanical load applied. Although the dielectric breakdown occurred in the ETM test, the post-test measurement revealed an impressive recovery of electric resistance. The failure analysis on cross section of tested specimens indicated a sizable gap across insulation layer near the area between copper conductor and loading rod, which apparently resulted from online dielectric failure and offline elastic recovery of components including conductor and insulation layer.

17 WIND ENERGY

Generic and ML Workloads in an HPC Datacenter: Node Energy, Job Failures, and Node-Job Analysis

HPC datacenters offer a backbone to the modern digital society. Increasingly, they run Machine Learning (ML) jobs next to generic, compute-intensive workloads, supporting science, business, and other decision-making processes. However, understanding how ML jobs impact the operation of HPC datacenters, relative to generic jobs, remains desirable but understudied. In this work, we leverage long-term operational data, collected from a national-scale production HPC datacenter, and statistically compare how ML and generic jobs can impact the performance, failures, resource utilization, and energy consumption of HPC datacenters. Our study provides key insights, e.g., ML-related power usage causes GPU nodes to run into temperature limitations, median/mean runtime and failure rates are higher for ML jobs than for generic jobs, both ML and generic jobs exhibit highly variable arrival processes and resource demands, significant amounts of energy are spent on unsuccessfully terminating jobs, and concurrent jobs tend to terminate in the same state. We open-source our cleaned-up data traces on Zenodo (https://doi. org/10.5281/zenodo.13685426), and provide our analysis toolkit as software hosted on GitHub (https://github.com/atlarge-research/2024-icpads-hpc-workload-characterization). This study offers multiple benefits for data center administrators, who can improve operational efficiency, and for researchers, who can further improve system designs, scheduling techniques, etc.

crossanalysis

Low Activity Waste Glass Optimization with Property Models from Machine Learning, Part 2: Experimental Validation and Active Learning

The United States Department of Energy is responsible for managing legacy nuclear waste stored in underground tanks at the Hanford Site. To treat the waste, it is planned as the current baseline to separately vitrify low-activity waste (LAW) and high-level waste fractions. Previously, machine learning (ML) based glass property models (e.g., chemical durability, viscosity, electrical conductivity and SO3 solubility) were developed with prediction uncertainties. A waste glass optimization approach was then established to enable the capability of using these ML models in LAW glass formulation. In this study, the previous ML models were first experimentally validated, and the results were incorporated back into the database to update the ML models. The updated models and formulations showed increased waste loading while reducing the failure rate, demonstrating improved predictive accuracy, reduced uncertainties, and the effectiveness of active learning in guiding high-dimensional, nonlinear LAW glass design. This represents the first experimental validation of ML based LAW glass formulation, with practical benefits such as higher waste loading, shorter mission duration, and lower operational risk.

Lu, Xiaonan (ORCID:0000000179708148)

Reliability Analysis of Power Grids Considering Component Failures of Variable Energy Resources

This paper proposes an improved model for the reliability assessment of power systems considering component failures of variable energy resources (VER). The inherent intermittency of VER such as solar photovoltaic (PV) and wind farms, along with their susceptibility to component failures, present significant challenges to reliable system operation. These issues, combined with power grid operation and network constraints, complicate the reliable operation of VER-integrated power systems. Here, to address these concerns, this paper introduces a reliability assessment framework that considers VER input variability, its impact on component availability, and their resulting impact on overall system reliability. Stochastic models based on discrete Markov processes are developed to incorporate variable irradiance, wind speeds, and their effects on PV and wind component failure rates. A next-event and state transition-based approach is then developed to integrate the stochastic models into a mixed-timing sequential Monte Carlo simulation framework for composite reliability assessment. Case studies on the RTS-GMLC system demonstrate the effectiveness of the proposed model in evaluating the reliability of VER-integrated systems.

Pandit, Dilip [Sandia National Laboratories (SNL-N

Underwater unexploded ordnance discrimination based on intrinsic target polarizabilities – A case study

Seabed unexploded ordnance that resulted partly from the high failure rate among munitions from more than 80 years ago and from decades of military training and testing of weapons systems poses an increasing concern all around the world. Although existing magnetic systems can detect clusters of debris, they are not able to tell whether a munition is still intact requiring special removal (e.g. in situ detonation) or is harmless scrap metal. The marine environment poses unique challenges, and transferring knowledge and approaches from land to a marine environment has not been easy and straightforward. On land, the background soil conductivity is much lower than the conductivity of the unexploded ordnance and the electromagnetic response of a target is essentially the same as that in free space. For those frequencies required for target characterization in the marine environment, the seawater response must be accounted for and removed from the measurements. The system developed for this study uses fields from three orthogonal transmitters to illuminate the target and four three-component receivers to measure the signal arranged in a configuration that inherently cancels the system's response due to the enclosing seawater, the sea–bottom interface and the air–sea interface for shallow deployments. The system was tested as a cued system on land and underwater in San Francisco Bay – it was mounted on a simple platform on top of a support structure that extended 1 m below and allowed the diver to place metal objects to a specific location even in low-visibility conditions. The measurements were stable and repeatable. Furthermore, target responses estimated from marine measurements matched those from land acquisition, confirming that the seawater and air–sea interface responses were removed successfully. Thirty-six channels of normalized induction responses were used for the classification, which was done by estimating the target principal dipole polarizabilities. Our results demonstrated that the system can resolve the intrinsic polarizabilities of the target, with clear distinctions between those of symmetric intact unexploded ordnance and irregular scrap metal. The prototype system was able to classify an object based on its size, shape and metal content and correctly estimate its location and orientation.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF