Search NASA⌕ Search

SEARCH · Search NASA

Results for “False data injection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Evaluation of a fault tolerant system for an integrated avionics sensor configuration with TSRV flight data

The performance analysis results of a fault inferring nonlinear detection system (FINDS) using sensor flight data for the NASA ATOPS B-737 aircraft in a Microwave Landing System (MLS) environment is presented. First, a statistical analysis of the flight recorded sensor data was made in order to determine the characteristics of sensor inaccuracies. Next, modifications were made to the detection and decision functions in the FINDS algorithm in order to improve false alarm and failure detection performance under real modelling errors present in the flight data. Finally, the failure detection and false alarm performance of the FINDS algorithm were analyzed by injecting bias failures into fourteen sensor outputs over six repetitive runs of the five minute flight data. In general, the detection speed, failure level estimation, and false alarm performance showed a marked improvement over the previously reported simulation runs. In agreement with earlier results, detection speed was faster for filter measurement sensors soon as MLS than for filter input sensors such as flight control accelerometers.

Caglayan, A. K.↗

Performance analysis of a fault inferring nonlinear detection system algorithm with integrated avionics flight data

This paper presents the performance analysis results of a fault inferring nonlinear detection system (FINDS) using integrated avionics sensor flight data for the NASA ATOPS B-737 aircraft in a Microwave Landing System (MLS) environment. First, an overview of the FINDS algorithm structure is given. Then, aircraft state estimate time histories and statistics for the flight data sensors are discussed. This is followed by an explanation of modifications made to the detection and decision functions in FINDS to improve false alarm and failure detection performance. Next, the failure detection and false alarm performance of the FINDS algorithm are analyzed by injecting bias failures into fourteen sensor outputs over six repetitive runs of the five minutes of flight data. Results indicate that the detection speed, failure level estimation, and false alarm performance show a marked improvement over the previously reported simulation runs. In agreement with earlier results, detection speed is faster for filter measurement sensors such as MLS than for filter input sensors such as flight control accelerometers. Finally, the progress in modifications of the FINDS algorithm design to accommodate flight computer constraints is discussed.

Caglayan, A. K.↗

Calculations of particle-laden flows by second-moment closures

A differential second-moment closure is applied to calculate nonswirling turbulent particle-laden jet flow. The closure is effected by extending constant-density single-phase turbulence models to the continuous (carrier) phase of two-phase flow. The dispersed (discrete) phase is treated by stochastic-Lagrangian technique. To reduce the effects of numerical (false) diffusion on the predicted results, a higher order differencing scheme, namely the flux-spline, is employed. In addition, an experimental study is conducted to provide data of good quality, especially near the inlet, for model assessment. The experiment consists of a confined coaxial jet flow of air with glass beads. The beads' diameter is 105 microns and is injected from the inner jet with a mass loading ratio of 0.9. The computed results are in good agreement with experimental data, especially for the carrier phase. However, the predicted turbulence fluctuations associated with the discrete phase are lower than the data at the downstream region of the flow field.

Nikjooy, M.↗

Kepler Planet Detection Metrics: Per-Target Flux-Level Transit Injection Tests of TPS for Data Release 25

Quantifying the ability of a transiting planet survey to recover transit signals has commonly been accomplished through Monte-Carlo injection of transit signals into the observed data and subsequent running of the signal search algorithm (Gilliland et al., 2000; Weldrake et al., 2005; Burke et al., 2006). In order to characterize the performance of the Kepler pipeline (Twicken et al., 2016; Jenkins et al., 2017) on a sample of over 200,000 stars, two complementary injection and recovery tests are utilized:1. Injection of a single transit signal per target into the image or pixel-level data, hereafter referred to as pixel-level transit injection (PLTI), with subsequent processing through the Photometric Analysis (PA), Presearch Data Conditioning (PDC), Transiting Planet Search (TPS), and Data Validation (DV) modules of the Kepler pipeline. The PLTI quantification of the Kepler pipeline's completeness has been described previously by Christiansen et al. (2015, 2016); the completeness of the final SOC 9.3 Kepler pipeline acting on the Data Release 25 (DR25) light curves is described by Christiansen (2017).2. Injection of multiple transit signals per target into the normalized flux time series data with a subsequent transit search using a stream-lined version of the Transiting Planet Search (TPS) module. This test, hereafter referred to as flux-level transit injection (FLTI), is the subject of this document. By running a heavily modified version of TPS, FLTI is able to perform many injections on selected targets and determine in some detail which injected signals are recoverable. Significant numerical efficiency gains are enabled by precomputing the data conditioning steps at the onset of TPS and limiting the search parameter space (i.e., orbital period, transit duration, and ephemeris zero-point) to a small region around each injected transit signal.The PLTI test has the advantage that it follows transit signals through all processing steps of the Kepler pipeline, and the recovered signals can be further classified as planet candidates or false positives in the exact same manner as detections from the nominal (i.e., observed) pipeline run (Twicken et al., 2016, Thompson et al., in preparation). To date, the PLTI test has been the standard means of measuring pipeline completeness averaged over large samples of targets (Christiansen et al., 2015, 2016; Christiansen, 2017). However, since the PLTI test uses only one injection per target, it does not elucidate individual-target variations in pipeline completeness due to differences in stellar properties or astrophysical variability. Thus, we developed the FLTI test to provide a numerically efficient way to fully map individual targets and explore the performance of the pipeline in greater detail. The FLTI tests thereby allow a thorough validation of the pipeline completeness models (such as window function (Burke and Catanzarite, 2017a), detection efficiency (Burke Catanzarite, 2017b), etc.) across the spectrum of Kepler targets (i.e., various astrophysical phenomena and differences in instrumental noise). Tests during development of the FLTI capability revealed that there are significant target-to-target variations in the detection efficiency.

DR25↗

In-Situ Wire Damage Detection System

An In-Situ Wire Damage Detection System (ISWDDS) has been developed that is capable of detecting damage to a wire insulation, or a wire conductor, or to both. The system will allow for realtime, continuous monitoring of wiring health/integrity and reduce the number of false negatives and false positives while being smaller, lighter in weight, and more robust than current systems. The technology allows for improved safety and significant reduction in maintenance hours for aircraft, space vehicles, satellites, and other critical high-performance wiring systems for industries such as energy production and mining. The integrated ISWDDS is comprised of two main components: (1) a wire with an innermost core conductor, an inner insulation film, a conductive layer or inherently conductive polymer (ICP) covering the inner insulation film, an outermost insulation jacket; and (2) smart connectors and electronics capable of producing and detecting electronic signals, and a central processing unit (CPU) for data collection and analysis. The wire is constructed by applying the inner insulation films to the conductor, followed by the outer insulation jacket. The conductive layer or ICP is on the outer surface of the inner insulation film. One or more wires are connected to the CPU using the smart connectors, and up to 64 wires can be monitored in real-time. The ISWDDS uses time domain reflectometry for damage detection. A fast-risetime pulse is injected into either the core conductor or conductive layer and referenced against the other conductor, producing transmission line behavior. If either conductor is damaged, then the signal is reflected. By knowing the speed of propagation of the pulse, and the time it takes to reflect, one can calculate the distance to and location of the damage.

Williams, Martha↗