The Influence of Chemical Descriptors on the Reactivity of Potential Hypergolic Fuels With Hydrogen Peroxide

The state-of-the-art for storable hypergolic bipropellant systems is monomethylhydrazine (MMH) and mixed oxides of nitrogen (MON). While MMH and MON provide fast and highly reliable hypergolic ignition with excellent propulsive performance, they suffer from safety concerns impacting their production, cost, and supply to various test and launch facilities. In contrast, identifying and demonstrating low-toxicity fuels hypergolic with rocket grade hydrogen peroxide (H2O2) has been challenging with long ignition delay (IDT) and low propulsive performance affecting their deployment in flight systems. This work describes a preliminary observational study to assess the effects of molecular descriptors suspected to predict the reactivity and hypergolicity of compounds within the same chemical class (i.e., thioamide). The approach centered on evaluating functional groups, electrostatic potential, number of carbons, dipole moment, and adiabatic ionization energy. Thiourea is hypergolic with 89.2 wt.% H2O2 (minimum IDT of 21.9 ms) and was selected as a core fuel to study the reactivity of derived fuels with different functionalities. Additionally, the chemical properties were calculated with the Gaussian16 suite. The results showed that group substitution and generally increased number of carbons on thiourea increases IDT. It was observed that a more positively charged sulfur atom in the thioamide does not increase the reactivity towards H2O2. The dipole moment analysis revealed an overall trend of decreasing IDT due to increasing dipole moment. Finally, a lower adiabatic ionization energy related to increased IDTs for most cases. Additional chemical classes comprising a wider range of functionalities and electrophilic attributes are being investigated in on-going work.

Propellant↗

Reliability Effects of Surge Current Testing of Solid Tantalum Capacitors

Solid tantalum capacitors are widely used in space applications to filter low-frequency ripple currents in power supply circuits and stabilize DC voltages in the system. Tantalum capacitors manufactured per military specifications (MIL-PRF-55365) are established reliability components and have less than 0.001% of failures per 1000 hours (the failure rate is less than 10 FIT) for grades D or S, thus positioning these parts among electronic components with the highest reliability characteristics. Still, failures of tantalum capacitors do happen and when it occurs it might have catastrophic consequences for the system. This is due to a short-circuit failure mode, which might be damaging to a power supply, and also to the capability of tantalum capacitors with manganese cathodes to self-ignite when a failure occurs in low-impedance applications. During such a failure, a substantial amount of energy is released by exothermic reaction of the tantalum pellet with oxygen generated by the overheated manganese oxide cathode, resulting not only in destruction of the part, but also in damage of the board and surrounding components. A specific feature of tantalum capacitors, compared to ceramic parts, is a relatively large value of capacitance, which in contemporary low-size chip capacitors reaches dozens and hundreds of microfarads. This might result in so-called surge current or turn-on failures in the parts when the board is first powered up. Such a failure, which is considered as the most prevalent type of failures in tantalum capacitors [I], is due to fast changes of the voltage in the circuit, dV/dt, producing high surge current spikes, I(sub sp) = Cx(dV/dt), when current in the circuit is unrestricted. These spikes can reach hundreds of amperes and cause catastrophic failures in the system. The mechanism of surge current failures has not been understood completely yet, and different hypotheses were discussed in relevant literature. These include a sustained scintillation breakdown model [1-3]; electrical oscillations in circuits with a relatively high inductance [4-6]; local overheating of the cathode [5,7, 8]; mechanical damage to tantalum pentoxide dielectric caused by the impact of MnO2 crystals [2,9, 10]; or stress-induced-generation of electron traps caused by electromagnetic forces developed during current spikes [11]. A commonly accepted explanation of the surge current failures is that at unlimited current supply during surge current conditions, the self-healing mechanism in tantalum capacitors does not work, and what would be a minor scintillation spike if the current were limited, becomes a catastrophic failure of the part [l, 12]. However, our data show that the scintillation breakdown voltages are significantly greater that the surge current breakdown voltages, so it is still not clear why the part, which has no scintillations, would fail at the same voltage during surge current testing (SCT).

Teverovsky, Alexander↗