Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fast Neutron Radiography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Analysis of a Prototype Multi-Detector Fast-Neutron Radiography Panel

A multi-detector fast neutron radiography panel was built using the previous work on scalable neutron radiography using the IDEAS ROSSPAD readout module. A new aluminum housing was built to accommodate a large number of detectors tiled together. Additional changes to startup and processing code were made to operate the detector as one cohesive unit. Spatial resolution of the full panel using Cs-137 gammas was reported to be 0.42 line pairs per centimeter at 90% MTF and 2.09 line pairs per centimeter at 10% MTF. Here, three neutron radiographs generated using a Cf-252 fission neutron source were used to determine the spatial resolution of the panel for neutrons. The experiments had 90% MTF values of 0.24, 0.3, and 0.27 line pairs per centimeter and 10% MTF values of 1.30, 1.46, and 1.40 line pairs per centimeter. An example neutron radiograph was also used to prove that the radiography panel can perform true neutron radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy-resolved fast-neutron radiography using an event-mode neutron imaging detector

Energy-resolved fast-neutron radiography is a powerful non-destructive technique that can be used to remotely measure the quantity and distribution of elements and isotopes in a sample. This is done by comparing the energy-dependent neutron transmission of a sample with the known cross-sections of individual isotopes. The reconstruction of the composition is possible due to the unique features (e.g. resonances) in the cross-sections of individual isotopes. At short-pulsed (≲ 1 ns) neutron sources, such information is accessible via time-of-flight neutron imaging in principle, but requires a detector with nanosecond temporal resolution. Conventional neutron detectors can meet this requirement only by heavily compromising spatial resolution or efficiency. Here, we present a unique approach on fast neutron resonance radiography using a scintillator-based event-mode imaging detector at a short-pulsed neutron source, including first results on spatially mapped resonance profiles using MeV neutrons. The event mode approach applied in the presented detector allows recording of individual neutron interactions with nanosecond precision in time and sub-mm resolution in space. As a result, the entire available neutron energy spectrum can be measured for each pulse. At the same time, the use of a thick scintillator screen and lenses to focus the produced light results in a highly flexible field of view and a high interaction probability in the sensitive volume of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Epithermal and Fast Neutron Radiography Facility HFIR Futures – Enhanced Capabilities Series (Vol. 8)

The Sustaining and Enhancing Nuclear Science Initiative at Oak Ridge National Laboratory (ORNL) was created to explore potential enhancements to scientific capabilities in the High Flux Isotope Reactor as part of a reactor pressure vessel replacement project. One proposed scientific enhancement included creation of an epithermal and fast neutron radiography station on the HB-3 beam tube with the capability to image highly radioactive specimens such as irradiated nuclear fuel rods, isotope production targets, or spallation neutron target materials. This document summarizes findings and recommendations from a working group of ORNL staff tasked with conceptualizing such a facility and includes a background of similar instruments at other research facilities, technical specifications, and an estimate of procurement cost and schedule.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Scalable Detector Design for a High-Resolution Fast-Neutron Radiography Panel

Development of a scalable flat-panel neutron radiography device is needed to meet the nondestructive testing needs of a growing industrial market. Flood field images from a Cs-137 gamma source and a Cf-252 fission neutron source were generated using a detector composed of a 3-mm-thick sheet of EJ-200, and 3-mm-thick sheet of acrylic light spreader, an 8 $\times$ 8 array of SensL MICROFJ-60035-TSV SiPMs, and an IDEAS ROSSPAD readout module. The readout module can be tiled together with similar systems to create a panel of any size, and is only limited by the number of available Ethernet ports in a switching system. A collimated gamma line image demonstrated a 90% spatial resolution of approximately 0.47 line pairs per centimeter and a 10% spatial resolution of approximately 2.32 line pairs per centimeter. A neutron edge image demonstrated a 90% spatial resolution of approximately 0.70 line pairs per centimeter and a 10% spatial resolution of approximately 3.35 line pairs per centimeter. Both of these images show the ability to generate radiographs with sub-SiPM spatial resolution. Using these readout modules, a large-scale radiographic panel can be developed by tiling ROSSPAD modules together.

36 MATERIALS SCIENCE↗

Quantifying spatial resolution in a fast neutron radiography system

Neutron imaging is a powerful nondestructive examination modality that has been employed in various applications. Fast neutrons provide advantages over lower energy neutrons, such as examining thicker samples and inducing negligible activation and transmutations. However, fast neutrons interact mostly via elastic scattering with both the neutron detector and the object, causing degradation in spatial resolution. This study explores the quantification of spatial resolution caused by the testing target itself and suggests proper candidate materials for characterizing spatial resolution in terms of modulation transfer function. Knife-edge radiographs of 3 mm, 6 mm, and 5 cm thick Tantalum (Ta) foils, and a 2.54 cm Tungsten (W) cube were acquired using a CCD-based imaging system and a Polyvinyl Toluene (PVT) scintillator at the Ohio State Research Reactor (OSURR)’s fast neutron beam facility. The spatial resolutions calculated were 195 ± 20 μm, 224 ± 22 μm, 248 ± 25 μm, and 435 ± 44 μm for 3 mm, 6 mm, and 5 cm Ta foils, and 2.54 cm W cube, respectively. The results showed a worsening spatial resolution with increasing target thickness. Simulations and calculations estimate that elastic scattering kinematics between neutrons and protons in the PVT medium also limits spatial resolution, and it sets a lower limit of ~44 μm on the spatial resolution for 2 MeV neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Neutron Radiography Simulations

Conclusions: Elements other than detector array can heavily impact performance; Must consider a variety of alterations to an imaging array to determine an optimal system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification of Material Type and Thickness Using Combined X-ray and Fast Neutron Radiography

Material identification (ID) using radiography is a problem that has implicitly existed since the discovery of the X-ray. Since 9-11, this problem has received renewed attention for homeland security applications of the generic, “what is in the box?” type1. Examples of items potentially in the box include: roadside bombs, nuclear weapons, contraband shipments and the like. In these cases, the “what” can include: explosives, projectiles, fissile material, or drugs. Here we investigate the ability of 60Co gamma-rays, 14MeV neutrons, and their combination to tease apart information about density, thickness and atomic number of items in the box. That information subset can be combined with other types of independent information (e.g. neutron and gammaspectroscopy, intelligence, photographs etc.) to assert a more complete picture of what, exactly, is in the box? That more complete information set can form the basis for actions including: remote detonation, evacuations, disablement, detention, search, arrest etc.

36 MATERIALS SCIENCE↗

Design Investigation of a Scalable Fast Neutron Radiography Panel

Advances in flat-panel radiography device design have increased the use of radiation imaging as a nondestructive evaluation tool. Neutron radiography offers many advantages compared to photon-based radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast neutron radiography-based on single-photon digital photosensor: concept and demonstration

For decades, fast neutron radiography performed using pulse-counting detectors employed PMTs coupled to plastic scintillator pixel arrays. SiPM-based systems are now sought to replace fragile PMTs, but conventional, “analog” SiPMs suffer from intrinsic limitations which limit their achievable performance. Among these limitations, a complete analog readout and digitizer chain is required, a counterintuitive approach when considering that the single-photon avalanche diode (SPAD), the basic unit cell of SiPMs, is a Boolean detector providing digital detection at the sensor level. This paper outlines a new concept for neutron radiography instrumentation by using photon-to-digital converters (PDCs, aka digital SiPMs), a fully digital solution to sense the scintillation light.

Pratte, Jean-Francois↗

Time-gated fast neutron transmission radiography system and method

The present disclosure relates to a time-gated fast neutron transmission radiography system and method. The system makes use of a pulsed neutron source for producing neutrons in a plurality of directions, with at least a subplurality of the neutrons being directed at an object to be imaged. The system also includes a neutron detector system configured to time-gate the detection of neutrons emitted from the pulsed neutron source to within a time-gated window.

Schmidt, Andrea↗

Fast-neutron/gamma-ray radiography using a broad-energy neutron source

Transmission radiography is a well-established nondestructive examination technique with widespread application to fields ranging from medicine to security. Traditionally, inspection is performed using a single particle type (such as x-rays). However, the information available using a single probe for traditional radiography is limited. The present work evaluates material discrimination via transmission radiography using the attenuation ratio of monoenergetic gamma rays to a broad spectrum of fast neutrons. Here, the method was assessed using an 241 Am/Be radioisotope source that provides both 4.4 MeV gamma rays and a spectrum of fast neutrons up to 12 MeV. A total of 14 object configurations were measured: seven different materials each with two thicknesses (2.5 cm and 5 cm). The ability to distinguish materials was evaluated and shows more significant variation among atomic numbers than for high-energy x-rays alone, making it easier to distinguish between classes such as low-, mid-, and high-Z materials. These results suggest that superior material discrimination is also possible using a combination of monoenergetic gamma rays and broad-spectrum fast neutrons from a variety of nuclear reactions, such as 11 B(d,nγ) 12 C, that could be implemented in future inspection systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon-to-Digital Converters for Neutron Imaging Instruments (Final Report)

Oak Ridge National Laboratory (ORNL) collaborated with the Université de Sherbrooke (UdeS) to design a modular and scalable tile of innovative digital photodetectors called Photon-to-Digital Converters (PDC) and the required subsystems to demonstrate the feasibility of large area single-photon detectors to support high-resolution, depth-of-interaction, fast neutron radiography based on scintillation detectors. The goal is to demonstrate the advantages of using PDC over conventional Silicon Photomultiplier (SiPM) for neutron imaging systems. The basic building blocks of analog SiPM and PDC are Single-Photon Avalanche Photodiodes (SPAD). The main difference between conventional SiPMs and PDCs, is in the fact that analog SiPMs sum the charge produced by individual SPAD passively, while in PDCs each SPAD is read out individually by an active electronic circuit. Hence, PDCs provide a direct photon-to-bit conversion where a logic “1” means that there was a detection in a given SPAD. Conversely, an analog SiPM requires a sophisticated preamplifier (current amplifiers or transimpedance amplifier) followed by a shaping amplifier and an analog-to-digital converter. Moreover, since the charge from each SPAD varies slightly, the passive sum of the analog SiPM will have signal fluctuations for the same amount of photon detected. This is one of many issues that is completely eliminated by individual one-to-one SPAD read out in PDCs. The large area required for scintillator readouts for neutron imaging is such that the output capacitance of a large area of SiPM arrays is very high. This creates a burden on the signal-to-noise optimization with respect to the power budget. For PDC, the power consumption is dictated by rate of the incident photon flux, or in photon-starved environments, the dark noise rate of the SPAD array. In other words, the power consumption in the absence of events is extremely low. Hence, the power consumption of a PDC read out system is much lower than its analog counterpart. Further, the large SiPM capacitance may introduce signal distortions on the scintillator fast rise or decay time with undesired effects on timing and pulse shape discrimination. The problem is absent in PDCs, as their readout is independent on device capacitance. UdeS is the world leader in 3D vertical integration of frontside illuminated SPAD arrays over CMOS readouts. These capabilities allow future production of “3D PDC” with maximum photosensitive fill factor and electronic functionalities tailored to the application. UdeS' vast knowledge of SPADs and CMOS design made the team an ideal collaborator in the development of large area high-resolution fast neutron radiography.

42 ENGINEERING↗

Gantryless Associated-Particle Neutron Radiography

The present work reports on the development of techniques for in-field fast-neutron radiography measurements using the associated-particle imaging (API) method. The API method employs alpha-neutron coincidences from the d+t→α+n reaction to enable fast neutron transmission imaging with excellent contrast using a wide cone beam. However, for field radiography applications, the API method is burdened by the need for the relative positions of the source and detector to be known. Fortunately, these relative positions can be inferred from transmission data. The inferred positions also enable accurate stitching of multiple images into a composite image even when using a low-resolution detector panel and acquiring images having few overlapping pixels. The developed techniques address analysis of measurements where (1) the source and detector panel are separately hand positioned rather than held in registration by a gantry, (2) multiple detector panel positions within the “coincident cone” of tagged neutrons are required to piece together an image of an item of interest, and (3) normalization measurements that have identical source-detector positioning but without the inspected object are not possible. The present work will describe the system calibrations (including timing calibrations and neutron direction calibrations) necessary for subsequent analyses, the method of locating the detector in the coincident cone of neutrons with millimeter precision using the timing and directions of coincident neutrons, the method of calculating a normalization image for a given detector panel position, and the method used to project multiple images into a common image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Transmission Imaging with a Portable D-T Neutron Generator

Fast-neutron transmission imaging provides complementary information to x-ray transmission imaging. While fast neutron imaging resolution is generally below x-ray imaging, 14-MeV neutrons have an advantage over portable x-ray systems. Neutrons have higher transmission through high-Z materials due to a more uniform attenuation as a function of material atomic number Z compared to X-rays, and can therefore image low-Z materials inside high-Z materials. As a result, portable neutron transmission imaging has many applications, including inspection of concrete and welds for corrosion in vehicles, bridges, and other infrastructure, measurement of material levels in containers, and inspection of suspicious packages. Fast-neutron imaging is also more practical for field use than thermal-neutron imaging due to the size and shielding requirements typical of thermal-imaging systems compared to the availability of small 14.1 MeV D-T neutron generators. However, there are limitations in portable fast-neutron imaging systems, including limited neutron output, limited light produced by neutron scintillators, and lower resolution due to neutron source spot size and 2-3 mm scintillator thickness. In addition, digital-panel dark-noise is roughly 100x higher than neutron scintillator light, and variations in noise across the panel and in time is comparable to the imaging signal. Here we discuss recent efforts in developing a portable fast-neutron radiography system, including an improved neutron scintillator, mitigation of panel noise, and new commercial portable D-T neutron generators. We also present MCNP efforts to model neutron imaging, including scintillator resolution and the effects of neutron scattering from the object and surrounding materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗