Search NASA⌕ Search

SEARCH · Search NASA

Results for “Faul”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Low-lying isomeric levels in {sup 75}Cu

Isomeric low-lying states were identified and investigated in the {sup 75}Cu nucleus. Two states at 61.8(5)- and 128.3(7)-keV excitation energies with half-lives of 370(40)- and 170(15)-ns were assigned as {sup 75m1}Cu and {sup 75m2}Cu, respectively. The measured half-lives combined with the recent spin assignment of the ground state allow one to deduce tentatively spin and parity of the two isomers and the dominant multipolarities of the isomeric transitions with respect to the systematics of the Cu isotopes. Shell-model calculations using an up-to-date effective interaction reproduce the evolution of the 1/2{sup -}, 3/2{sup -}, and 5/2{sup -} states for the neutron-rich odd-mass Cu isotopes when filling the nug{sub 9/2}. The results indicate a significant change in the nuclear structure in this region, where a single-particle 5/2{sup -} state coexists with more and more collective 3/2{sup -} and 1/2{sup -} levels at low excitation energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Field of view extension and truncation correction for MR-based human attenuation correction in simultaneous MR/PET imaging

Purpose: In quantitative PET imaging, it is critical to accurately measure and compensate for the attenuation of the photons absorbed in the tissue. While in PET/CT the linear attenuation coefficients can be easily determined from a low-dose CT-based transmission scan, in whole-body MR/PET the computation of the linear attenuation coefficients is based on the MR data. However, a constraint of the MR-based attenuation correction (AC) is the MR-inherent field-of-view (FoV) limitation due to static magnetic field (B{sub 0}) inhomogeneities and gradient nonlinearities. Therefore, the MR-based human AC map may be truncated or geometrically distorted toward the edges of the FoV and, consequently, the PET reconstruction with MR-based AC may be biased. This is especially of impact laterally where the patient arms rest beside the body and are not fully considered. Methods: A method is proposed to extend the MR FoV by determining an optimal readout gradient field which locally compensates B{sub 0} inhomogeneities and gradient nonlinearities. This technique was used to reduce truncation in AC maps of 12 patients, and the impact on the PET quantification was analyzed and compared to truncated data without applying the FoV extension and additionally to an established approach of PET-based FoV extension. Results: The truncation artifacts in the MR-based AC maps were successfully reduced in all patients, and the mean body volume was thereby increased by 5.4%. In some cases large patient-dependent changes in SUV of up to 30% were observed in individual lesions when compared to the standard truncated attenuation map. Conclusions: The proposed technique successfully extends the MR FoV in MR-based attenuation correction and shows an improvement of PET quantification in whole-body MR/PET hybrid imaging. In comparison to the PET-based completion of the truncated body contour, the proposed method is also applicable to specialized PET tracers with little uptake in the arms and might reduce the computation time by obviating the need for iterative calculations of the PET emission data beyond those required for reconstructing images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structure of neutron-rich nuclei around the N = 50 shell-gap closure

The structure of neutron-rich nuclei in the vicinity of {sup 78}Ni have been investigated via the beta-decay of {sup 71,73,75}Cu isotopes (ISOLDE, CERN). Experimental results have been compared with shell-model calculations performed with the ANTOINE code using a large (2p{sub 3/2}1 f{sub 5/2}2 p{sub 1/2}1 g{sub 9/2}) valence space and a (56/28)Ni{sub 28} core.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Single and Multi-Nucleon Transfer Reactions for Nuclear Moment Studies Toward Radioactive-Ion Beams

This study is a part of an experimental program to measure nuclear moments in transfer reactions. It aims to probe for a first time the nuclear -spin orientation in multi-nucleon transfer. Fist experiments were performed to measure the quadrupole moment of an isomeric state in {sup 66}Cu (I{sup p}i 6{sup -}, E{sub x} = 1154 keV, T{sub 1/2} = 595(20) ns) in single nucleon transfer and the population of mus isomers in {sup 66}Cu and {sup 63}Ni in multi-nucleon transfer. The experimentally tested methodology allows broad applications toward more exotic species and feasibility of these reactions to produce species away from stability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sci—Thur AM: YIS - 08: Constructing an Attenuation map for a PET/MR Breast coil

In 2013, around 23000 Canadian women and 200 Canadian men were diagnosed with breast cancer. An estimated 5100 women and 55 men died from the disease. Using the sensitivity of MRI with the selectivity of PET, PET/MRI combines anatomical and functional information within the same scan and could help with early detection in high-risk patients. MRI requires radiofrequency coils for transmitting energy and receiving signal but the breast coil attenuates PET signal. To correct for this PET attenuation, a 3-dimensional map of linear attenuation coefficients (μ-map) of the breast coil must be created and incorporated into the PET reconstruction process. Several approaches have been proposed for building hardware μ-maps, some of which include the use of conventional kVCT and Dual energy CT. These methods can produce high resolution images based on the electron densities of materials that can be converted into μ-maps. However, imaging hardware containing metal components with photons in the kV range is susceptible to metal artifacts. These artifacts can compromise the accuracy of the resulting μ-map and PET reconstruction; therefore high-Z components should be removed. We propose a method for calculating μ-maps without removing coil components, based on megavoltage (MV) imaging with a linear accelerator that has been detuned for imaging at 1.0MeV. Containers of known geometry with F18 were placed in the breast coil for imaging. A comparison between reconstructions based on the different μ-map construction methods was made. PET reconstructions with our method show a maximum of 6% difference over the existing kVCT-based reconstructions.

60 APPLIED LIFE SCIENCES↗

SU-D-201-05: Phantom Study to Determine Optimal PET Reconstruction Parameters for PET/MR Imaging of Y-90 Microspheres Following Radioembolization

Purpose: Imaging Y-90 microspheres with PET/MRI following hepatic radioembolization has the potential for predicting treatment outcome and, in turn, improving patient care. The positron decay branching ratio, however, is very small (32 ppm), yielding images with poor statistics even when therapy doses are used. Our purpose is to find PET reconstruction parameters that maximize the PET recovery coefficients and minimize noise. Methods: An initial 7.5 GBq of Y-90 chloride solution was used to fill an ACR phantom for measurements with a PET/MRI scanner (Siemens Biograph mMR). Four hot cylinders and a warm background activity volume of the phantom were filled with a 10:1 ratio. Phantom attenuation maps were derived from scaled CT images of the phantom and included the MR phased array coil. The phantom was imaged at six time points between 7.5–1.0 GBq total activity over a period of eight days. PET images were reconstructed via OP-OSEM with 21 subsets and varying iteration number (1–5), post-reconstruction filter size (5–10 mm), and either absolute or relative scatter correction. Recovery coefficients, SNR, and noise were measured as well as total activity in the phantom. Results: For the 120 different reconstructions, recovery coefficients ranged from 0.1–0.6 and improved with increasing iteration number and reduced post-reconstruction filter size. SNR, however, improved substantially with lower iteration numbers and larger post-reconstruction filters. From the phantom data, we found that performing 2 iterations, 21 subsets, and applying a 5 mm Gaussian post-reconstruction filter provided optimal recovery coefficients at a moderate noise level for a wide range of activity levels. Conclusion: The choice of reconstruction parameters for Y-90 PET images greatly influences both the accuracy of measurements and image quality. We have found reconstruction parameters that provide optimal recovery coefficients with minimized noise. Future work will include the effects of the body matrix coil and off-center measurements.

60 APPLIED LIFE SCIENCES↗

NEAMS-IPL MOOSE Framework Activities

The Multiapp Picard iteration Milestone’s purpose was to support a framework level “tight-coupling” method within the hierarchical Multiapp’s execution scheme. This new solution scheme gives developers new choices for running multiphysics applications, particularly those with very strong nonlinear effects or those requiring coupling across disparate time or spatial scales. Figure 1 shows a typical Multiapp setup in MOOSE. Each node represents a separate simulation containing a separate equation system. MOOSE solves the equation system on each node in turn, in a user-controlled manner. Information can be aggregated or split and transferred from parent to child or child to parent as needed between solves. Performing a tightly coupled execution scheme using this method wasn’t possible in the original implementation. This is was due to the inability to back up to a previous state once a converged solution was accepted at a particular Multiapp level.

97 MATHEMATICS AND COMPUTING↗