Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fault Estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Ensemble models for circuit topology estimation, fault detection and classification in distribution systems

This paper presents a methodology for simultaneous fault detection, classification, and topology estimation for adaptive protection of distribution systems. The methodology estimates the probability of the occurrence of each one of these events by using a hybrid structure that combines three sub-systems, a convolutional neural network for topology estimation, a fault detection based on predictive residual analysis, and a standard support vector machine with probabilistic output for fault classification. The input to all these sub-systems is the local voltage and current measurements. A convolutional neural network uses these local measurements in the form of sequential data to extract features and estimate the topology conditions. The fault detector is constructed with a Bayesian stage (a multitask Gaussian process) that computes a predictive distribution (assumed to be Gaussian) of the residuals using the input. Since the distribution is known, these residuals can be transformed into a Standard distribution, whose values are then introduced into a one-class support vector machine. The structure allows using a one-class support vector machine without parameter cross-validation, so the fault detector is fully unsupervised. Finally, a support vector machine uses the input to perform the classification of the fault types. All three sub-systems can work in a parallel setup for both performance and computation efficiency. In conclusion, we test all three sub-systems included in the structure on a modified IEEE123 bus system, and we compare and evaluate the results with standard approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs) at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring, Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases, distribution system state estimation (DSSE) and fault identification are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1 feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system↗

Estimation of Faults in DC Electrical Power System

This paper demonstrates a novel optimization-based approach to estimating fault states in a DC power system. Potential faults changing the circuit topology are included along with faulty measurements. Our approach can be considered as a relaxation of the mixed estimation problem. We develop a linear model of the circuit and pose a convex problem for estimating the faults and other hidden states. A sparse fault vector solution is computed by using 11 regularization. The solution is computed reliably and efficiently, and gives accurate diagnostics on the faults. We demonstrate a real-time implementation of the approach for an instrumented electrical power system testbed, the ADAPT testbed at NASA ARC. The estimates are computed in milliseconds on a PC. The approach performs well despite unmodeled transients and other modeling uncertainties present in the system.

Gorinevsky, Dimitry↗

A multi-agent approach to distribution system fault section estimation in smart grid environment

We report that Multi-Agent Systems (MAS) are seen from different areas as one of the paramount trends for the next generation of power systems. Numerous published studies about MAS discuss its utilization in power distribution networks but none focuses on the prior step to restoration and self-healing that is fault section estimation. This paper aims to show how MAS can improve the utilities’ reliability indexes and consumer satisfaction by overcoming the multiple fault section estimation problem. In order to do this, the authors considered using MAS as a means of communication between smart meters. The purpose of smart meters usage is to employ devices that are already present in smart grids, mainly because of their reading and saving data capacity. The proposed method was tested on a radial feeder generated by the authors. The network was built on HYPERSIM, a software platform of OPAL-RT Technologies. The simulation results show that this MAS provides speed, efficiency, and automation for the process of fault section estimation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Method and system for diagnostics of apparatus

Proposed is a method, implemented in software, for estimating fault state of an apparatus outfitted with sensors. At each execution period the method processes sensor data from the apparatus to obtain a set of parity parameters, which are further used for estimating fault state. The estimation method formulates a convex optimization problem for each fault hypothesis and employs a convex solver to compute fault parameter estimates and fault likelihoods for each fault hypothesis. The highest likelihoods and corresponding parameter estimates are transmitted to a display device or an automated decision and control system. The obtained accurate estimate of fault state can be used to improve safety, performance, or maintenance processes for the apparatus.

Gorinevsky, Dimitry↗

An Integrated Approach for Aircraft Engine Performance Estimation and Fault Diagnostics

A Kalman filter-based approach for integrated on-line aircraft engine performance estimation and gas path fault diagnostics is presented. This technique is specifically designed for underdetermined estimation problems where there are more unknown system parameters representing deterioration and faults than available sensor measurements. A previously developed methodology is applied to optimally design a Kalman filter to estimate a vector of tuning parameters, appropriately sized to enable estimation. The estimated tuning parameters can then be transformed into a larger vector of health parameters representing system performance deterioration and fault effects. The results of this study show that basing fault isolation decisions solely on the estimated health parameter vector does not provide ideal results. Furthermore, expanding the number of the health parameters to address additional gas path faults causes a decrease in the estimation accuracy of those health parameters representative of turbomachinery performance deterioration. However, improved fault isolation performance is demonstrated through direct analysis of the estimated tuning parameters produced by the Kalman filter. This was found to provide equivalent or superior accuracy compared to the conventional fault isolation approach based on the analysis of sensed engine outputs, while simplifying online implementation requirements. Results from the application of these techniques to an aircraft engine simulation are presented and discussed.

imon, Donald L.↗

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification: Preprint

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs)at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases - distribution system state estimation (DSSE) and fault identification - are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system monitoring↗

Estimating residual fault hitting rates by recapture sampling

For the recapture debugging design introduced by Nayak (1988) the problem of estimating the hitting rates of the faults remaining in the system is considered. In the context of a conditional likelihood, moment estimators are derived and are shown to be asymptotically normal and fully efficient. Fixed sample properties of the moment estimators are compared, through simulation, with those of the conditional maximum likelihood estimators. Properties of the conditional model are investigated such as the asymptotic distribution of linear functions of the fault hitting frequencies and a representation of the full data vector in terms of a sequence of independent random vectors. It is assumed that the residual hitting rates follow a log linear rate model and that the testing process is truncated when the gaps between the detection of new errors exceed a fixed amount of time.

Lee, Larry↗

Fault isolation and fault-tolerant control for nonlinear stochastic distribution control systems with multiplicative faults

Here, in this paper, a fault isolation, diagnosis and fault tolerant control algorithm is proposed for nonlinear multiple multiplicative faults stochastic distribution control systems employing Takagi–Sugeno fuzzy system. To obtain the detailed fault information, a fault detection algorithm is introduced to discover the fault occurrence time. Then a fault isolation observer is built to produce the residual, and the error system is separated to subsystems affected only by disturbance and multiplicative faults. Moreover, a fault estimation scheme is presented to obtain the fault magnitude information. When faults occur, the system output probability density function will deviate from the desired distribution. So the model predictive control fault tolerant control scheme is needed to minimize the impact of faults as much as possible to make sure that the post fault output probability density function track the desired probability density function. The validity of the designed algorithm is demonstrated through a simulation example, where the fault tolerant control algorithm ensures that the system output probability density function still track the given output probability density function despite the complex case of multiple multiplicative faults occurring simultaneously.

42 ENGINEERING↗

Fault isolation and fault-tolerant control for Takagi-Sugeno fuzzy time-varying delay stochastic distribution systems

A fault isolation, estimation, and fault-tolerant control (FTC) scheme for nonlinear time-varying delay stochastic distribution control systems was presented in this paper. The Takagi-Sugeno fuzzy model was adopted to approach the nonlinear dynamics of time-varying delay systems. According to the output equivalence principle and Laplace transformation, an augmented state vector was given to solve the time-varying delay problem. When multiple actuator faults and interference occur simultaneously, fault detection, isolation and fault estimation was designed to obtained the fault information. To decouple faults and obtain the value and location information of the fault, the system was separated into two parts through the designed multiple conversion matrices, in which one subsystem was only affected by one actuator fault. This has simplified the design of fault isolation and estimation. A adaptive observer for fault estimation was given. Then, fault information such as the time, location, and size was determined. The observer gain matrices were calculated using linear matrix inequality (LMI). When a fault was detected and diagnosed, a FTC algorithm was devised using the proportional-integral control scheme to compensate the fault as much as possible. It has been shown that even if multiple faults actuator occurred simultaneously, the FTC controller still ensured the output probability density function of the system traced the desired probability density function when a fault occurred. Finally, the expected results were obtained through the simulation example, which confirmed the effectiveness of the method.

42 ENGINEERING↗

Comprehensive AI-based System for Control, Sensor Estimation, and Fault Detection of Cascaded Multilevel Inverters

In this paper, an Artificial Intelligence-based (AI) system is proposed for an 11-level cascaded H-bridge multilevel inverter (MLI) with the aims of harmonic suppression and reliability enhancement. The system consists of three seamlessly integrated Neural Networks (NNs). First, a multilayer perceptron is used to generalize the optimal switching angles for selective harmonic elimination under non-equal DC voltages. Next, an autoencoder NN estimates the voltage sensor readings to address potential drifting. Finally, a perceptron NN detects inverter faults based solely on the output voltage of the MLI. Simulation scenarios were evaluated, and the results show that the proposed system provides a comprehensive solution for the robust operation of the MLI. The proposed solution is capable of minimizing the targeted harmonics orders with minimal impact on the fundamental voltage, even when the voltage sensor drifts. Furthermore, the inverter under fault conditions was successfully identified.

Rezende da Costa Reis Kimpara, Renata↗

Parameter Transient Behavior Analysis on Fault Tolerant Control System

In a fault tolerant control (FTC) system, a parameter varying FTC law is reconfigured based on fault parameters estimated by fault detection and isolation (FDI) modules. FDI modules require some time to detect fault occurrences in aero-vehicle dynamics. This paper illustrates analysis of a FTC system based on estimated fault parameter transient behavior which may include false fault detections during a short time interval. Using Lyapunov function analysis, the upper bound of an induced-L2 norm of the FTC system performance is calculated as a function of a fault detection time and the exponential decay rate of the Lyapunov function.

Belcastro, Christine↗

Optimization-Based Data-Driven Approach for Detecting Fault Location in Power Systems

In grids with large penetration of converterinterfaced resources (CIRs), measurements of voltage, current, and line parameters can fluctuate significantly during fault conditions. These fluctuations, combined with complex network topologies and extensive system branching, make accurate fault location challenging. Faults, such as short circuits, can cause prolonged outages with serious socio-economic impacts, highlighting the need for rapid fault identification to minimize downtime. However, current fault detection methods—such as relays and digital fault recorders—often relay information too slowly, impeding swift corrective action. Given the limited availability of high-resolution phasor measurement units, this paper introduces an optimization-based observer to estimate fault locations, grid line parameters, and voltages using local CIR measurements. To preserve the confidentiality of CIRs and enhance estimation accuracy, this study uses a black-box model of CIRs. This bottom-up, event-driven approach can enhances protection and control systems through optimized and real-time fault detection. Simulation results show that the optimization-based data-driven observer can accurately detect fault locations and estimate grid states and parameters, providing valuable insights for utilities and operators in grid applications.

Subedi, Sunil [ORNL] (ORCID:000000034069090X)↗

A physics‐informed learning technique for fault location of DC microgrids using traveling waves

Abstract Fast and accurate fault location in DC power systems is of particular importance to ensure their reliable operation. One of the approaches for implementing a fast‐tripping protection scheme is to use Traveling waves (TW) initiated by a fault scenario. This paper proposes a physics‐informed machine learning approach that utilizes TWs for fault location in DC microgrids. TWs are extracted by the so‐called multiresolution analysis which identifies the TW's wavelet coefficients for multiple frequency ranges. This paper deploys Parseval's theorem to find the energy of wavelet coefficients as a quantitative metric for describing TWs. The hypothesis of this paper is that once the Parseval energy curves for a specific cable are extracted, they can be utilized to locate faults along with that cable regardless of the DC system in which the cable is deployed. The fault location algorithm uses Parseval energy curves to train a Gaussian Process (GP) estimator. With the Parseval energy values of measured current at the protection device location, the GP estimator is able to estimate fault locations with high accuracy. The effectiveness of the proposed algorithm is verified by simulating a DC microgrid system in PSCAD/EMTDC.

Paruthiyil, Sajay Krishnan↗