Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fault Isolation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Fault isolation and fault-tolerant control for Takagi-Sugeno fuzzy time-varying delay stochastic distribution systems

A fault isolation, estimation, and fault-tolerant control (FTC) scheme for nonlinear time-varying delay stochastic distribution control systems was presented in this paper. The Takagi-Sugeno fuzzy model was adopted to approach the nonlinear dynamics of time-varying delay systems. According to the output equivalence principle and Laplace transformation, an augmented state vector was given to solve the time-varying delay problem. When multiple actuator faults and interference occur simultaneously, fault detection, isolation and fault estimation was designed to obtained the fault information. To decouple faults and obtain the value and location information of the fault, the system was separated into two parts through the designed multiple conversion matrices, in which one subsystem was only affected by one actuator fault. This has simplified the design of fault isolation and estimation. A adaptive observer for fault estimation was given. Then, fault information such as the time, location, and size was determined. The observer gain matrices were calculated using linear matrix inequality (LMI). When a fault was detected and diagnosed, a FTC algorithm was devised using the proportional-integral control scheme to compensate the fault as much as possible. It has been shown that even if multiple faults actuator occurred simultaneously, the FTC controller still ensured the output probability density function of the system traced the desired probability density function when a fault occurred. Finally, the expected results were obtained through the simulation example, which confirmed the effectiveness of the method.

42 ENGINEERING↗

Fault isolation and fault-tolerant control for nonlinear stochastic distribution control systems with multiplicative faults

Here, in this paper, a fault isolation, diagnosis and fault tolerant control algorithm is proposed for nonlinear multiple multiplicative faults stochastic distribution control systems employing Takagi–Sugeno fuzzy system. To obtain the detailed fault information, a fault detection algorithm is introduced to discover the fault occurrence time. Then a fault isolation observer is built to produce the residual, and the error system is separated to subsystems affected only by disturbance and multiplicative faults. Moreover, a fault estimation scheme is presented to obtain the fault magnitude information. When faults occur, the system output probability density function will deviate from the desired distribution. So the model predictive control fault tolerant control scheme is needed to minimize the impact of faults as much as possible to make sure that the post fault output probability density function track the desired probability density function. The validity of the designed algorithm is demonstrated through a simulation example, where the fault tolerant control algorithm ensures that the system output probability density function still track the given output probability density function despite the complex case of multiple multiplicative faults occurring simultaneously.

42 ENGINEERING↗

Adaptive Threshold-Based Zonal Isolation of Faults in a Multiterminal DC Using Local Measurements

Fast and accurate methods of fault detection and isolation are a pre-emptive measure in multiterminal dc (MTdc) systems. Zonal isolation of faults is necessary to prevent any misopertation of the dc breakers that can lead to a shutdown of the network. Existing techniques require fast-communication or data synchronization methods have their own disadvantages. This article proposes a method for efficient fault zone isolation without the need of a communication link that prevents any misoperation of the dc breakers in a radial MTdc. This method provides individual local measurement-based control to the hybrid dc circuit breakers (dcCB). Faults created outside the zone of protection for a breaker create a change in the rate of change of current or voltage leading to misoperation. To avoid detection using a fixed threshold, an adaptive threshold based approach is suggested that updates the threshold based on the present operating status. Sensitivity analysis by varying the current limiting inductance and fault location is performed. In conclusion, a three terminal radial model of an MTdc is used for zonal isolation using power system computer aided design/electromagnetic transients including dc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Energy Resource-Cognizant Upgrade Paths to the Traditional Restoration Strategy of Utilities for Improved Load Restoration

Climate change has resulted in increasingly impactful and more frequent occurrences of extreme weather events. This trend poses a significant challenge for distribution utilities and system operators to ensure that there is uninterrupted power supply to critical loads in their networks under fault scenarios; however, currently, utilities deploying the automated fault location, isolation and restoration (FLISR) function in their advanced distribution management system (ADMS) do not take into account the available generation and load-modification capabilities of distributed energy resources present in the disconnected network due to an upstream isolated fault. This results in the network reconfiguration and restoration to result in sub-optimal load restoration. Therefore, this paper presents two approaches that can upgrade the existing FLISR capabilities of distribution utilities to significantly increase the restoration of critical loads. The performance of the proposed approaches is evaluated on a numerical model of a real distribution feeder in Georgia, USA.

DER↗

Distributed Energy Resource-Cognizant Upgrade Paths to the Traditional Restoration Strategy of Utilities for Improved Load Restoration: Preprint

Climate change has resulted in increasingly impactful and more frequent occurrences of extreme weather events. This trend poses a significant challenge for distribution utilities and system operators to ensure that there is uninterrupted power supply to critical loads in their networks under fault scenarios; however, currently, utilities deploying the automated fault location, isolation and restoration (FLISR) function in their advanced distribution management system (ADMS) do not take into account the available generation and load-modification capabilities of distributed energy resources present in the disconnected network due to an upstream isolated fault. This results in the network reconfiguration and restoration to result in sub-optimal load restoration. Therefore, this paper presents two approaches that can upgrade the existing FLISR capabilities of distribution utilities to significantly increase the restoration of critical loads. The performance of the proposed approaches is evaluated on a numerical model of a real distribution feeder in Georgia, USA.

DER↗

Defining a Use Case for the ADMS Test Bed: Fault Location, Isolation, and Service Restoration with Distributed Energy Resources

Advanced distribution management systems (ADMS) integrate multiple enterprise-level functions into a single platform and offer advanced applications such as fault location, isolation, and service restoration (FLISR), to utilities to meet their operational needs for a modernized grid. These applications need to operate reliably even as distributed energy resource (DER) penetration increases on distribution systems. The ADMS test bed at the National Renewable Energy Laboratory offers utilities and vendors the opportunity to evaluate the performance of such advanced applications on distribution feeders of the future and to understand their potential benefits for a specific utility. This is done through defining use cases that address specific questions. This paper presents the definition of a use case on the performance of a commercially-available FLISR application on a feeder of an electric cooperative with DERs. After experiments are completed, results from this use case will be disseminated to the electric utility and research community to improve understanding of the challenges and benefits that DERs present to ADMS applications and the operation of a modernized grid.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Defining a Use Case for the ADMS Test Bed: Fault Location, Isolation, and Service Restoration with Distributed Energy Resources: Preprint

Advanced distribution management systems (ADMS) integrate multiple enterprise-level functions into a single platform and offer advanced applications such as fault location, isolation, and service restoration (FLISR), to utilities to meet their operational needs for a modernized grid. These applications need to operate reliably even as distributed energy resource (DER) penetration increases on distribution systems. The ADMS test bed at the National Renewable Energy Laboratory offers utilities and vendors the opportunity to evaluate the performance of such advanced applications on distribution feeders of the future and to understand their potential benefits for a specific utility. This is done through defining use cases that address specific questions. This paper presents the definition of a use case on the performance of a commercially-available FLISR application on a feeder of an electric cooperative with DERs. Results from this use case will be disseminated to the electric utility and research community to improve understanding of the challenges and benefits that DERs present to ADMS applications and the operation of a modernized grid.

61 RADIATION PROTECTION AND DOSIMETRY↗

Enhanced data validation strategy of air quality monitoring network

Quick validation and detection of faults in measured air quality data is a crucial step towards achieving the objectives of air quality networks. Therefore, the objectives of this paper are threefold: (i) to develop a modeling technique that can be used to predict the normal behavior of air quality variables and help provide accurate reference for monitoring purposes; (ii) to develop fault detection method that can effectively and quickly detect any anomalies in measured air quality data. For this purpose, a new fault detection method that is based on the combination of generalized likelihood ratio test (GLRT) and exponentially weighted moving average (EWMA) will be developed. GLRT is a well-known statistical fault detection method that relies on maximizing the detection probability for a given false alarm rate. In this paper, we propose to develop GLRT-based EWMA fault detection method that will be able to detect the changes in the values of certain air quality variables; (iii) to develop fault isolation and identification method that allows defining the fault source(s) in order to properly apply appropriate corrective actions. In this paper, reconstruction approach that is based on Midpoint-Radii Principal Component Analysis (MRPCA) model will be developed to handle the types of data and models associated with air quality monitoring networks. All air quality modeling, fault detection, fault isolation and reconstruction methods developed in this paper will be validated using real air quality data (such as particulate matter, ozone, nitrogen and carbon oxides measurement).

54 ENVIRONMENTAL SCIENCES↗

Fault Diagnosis of Hybrid Computing Systems Using Chaotic-Map Method

Computing systems are becoming increasingly complex with nodes consisting of a combination of multi-core central processing units (CPUs), many integrated core (MIC) and graphics processing unit (GPU) accelerators. These computing units and their interconnections are subject to different classes of hardware and software faults, which should be detected to support mitigation measures. We present the chaotic-map method that uses the exponential divergence and wide Fourier properties of the trajectories, combined with memory allocations and assignments to diagnose component-level faults in these hybrid computing systems. We propose lightweight codes that utilize highly parallel chaotic-map computations tailored to isolate faults in arithmetic units, memory elements and interconnects. The diagnosis module on a node utilizes pthreads to place chaotic-map threads on CPU and MIC cores, and CUDA C and OpenCL kernels on GPU blocks. We present experimental diagnosis results on five multi-core CPUs; one MIC; and, seven GPUs with typical diagnosis run-times under a minute.

Rao, Nageswara↗

End-to-end microgrid protection using distributed data-driven methods

This paper introduces an end-to-end microgrid protection framework that offers real-time system monitoring, fault-related decision making, and circuit breaker control. This is achieved through the design of distributed data-driven techniques based on the support vector machine method, where each relay is responsible for distributed data collection, fault detection, fault localization, and fault isolation. Local communication is established among neighboring relays, fostering cooperative fault localization and isolation. This decentralized design not only reduces the computational and communication requirements but also enables the adaptability of each relay under varying operational dynamics. The proposed end-to-end protection framework was validated using MATLAB/Simulink simulations on a 100% renewable microgrid, achieving an accuracy of 93.1% with response time of 0.0523 s, in protecting against a range of fault scenarios that are characterized by various types, locations, impedances, load conditions, photovoltaic power levels, and microgrid operating modes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

End-To-End Decentralized Transmission Line Protection in IBR-Dominated Weak Grids Using Interpretable Data-Driven Methods

Traditional transmission line protection relies on predictable synchronous-based fault signatures, which frequently fail under the non-standard, current-limited fault characteristics of Inverter-Based Resources (IBRs). This study investigates how to achieve secure, communication-free fault isolation in IBR-dominated weak grids without relying on opaque, computationally heavy "black-box" machine learning algorithms. To address this, we propose a novel, standalone, and inherently interpretable data-driven protection framework. Unlike centralized methods requiring multi-terminal communication, this decentralized approach relies solely on local measurements using a hierarchical linear-kernel Support Vector Machine (SVM). The methodology decomposes the protection task into four sequential stages that mimic traditional protection elements: fault detection and fault direction identification, fault type classification, zone classification, and location estimation. This multi-stage architecture allows for specialized feature engineering at each stage, combining high computational efficiency with logic traceability. The framework's end-to-end performance was validated via C-code and PSCAD/EMTDC co-simulation, utilizing a real-world utility network and an OEM black-box IBR model. The proposed relay achieves 97.2% overall accuracy and provides a reliable trip decision within a 2.5-cycle window. The results confirm 100% accuracy in fundamental fault detection, reliable zone selectivity across low to moderate fault resistances, and robust security against non-fault transients, proving its immediate viability for integration into commercial numerical relays.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spatial-Temporal Recurrent Graph Neural Networks for Fault Diagnostics in Power Distribution Systems

Fault diagnostics are extremely important to decide proper actions toward fault isolation and system restoration. The growing integration of inverter-based distributed energy resources imposes strong influences on fault detection using traditional overcurrent relays. This paper utilizes emerging graph learning techniques to build new temporal recurrent graph neural network models for fault diagnostics. The temporal recurrent graph neural network structures can extract the spatial-temporal features from data of voltage measurement units installed at the critical buses. From these features, fault event detection, fault type/phase classification, and fault location are performed. Compared with previous works, the proposed temporal recurrent graph neural networks provide a better generalization for fault diagnostics. Moreover, the proposed scheme retrieves the voltage signals instead of current signals so that there is no need to install relays at all lines of the distribution system. Therefore, the proposed scheme is generalizable and not limited by the number of relays installed. The effectiveness of the proposed method is comprehensively evaluated on the Potsdam microgrid and IEEE 123-node system in comparison with other neural network structures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fault Detection for Dynamical Systems using Differential Geometric and Concurrent Learning Approach

This paper presents a fault identification and estimation approach that brings together the differential geometric concept of observability codistribution with data driven concurrent learning. In order to identify faults in presence of unknown disturbances, we utilize the differential geometric approach to design a coordinate transformation, to find a subspace in which the effect of disturbances and system faults can be segregated. We then use concurrent learning to estimate magnitude of the constant fault. We illustrate the approach to fault isolation for a linear helicopter dynamics and a spherical pendulum dynamics. We use Lyapunov stability analysis to show that the fault estimate by concurrent learning converges to the actual fault value, and then illustrate the design of a recovery controller.

Fault detection and diagnosis↗

Role of Well Operations and Multiphase Geomechanics in Controlling Fault Stability During CO 2 Storage and Enhanced Oil Recovery

CO 2 injection in active oil fields is a technology proposed for industrializing carbon storage operations. However, monitoring CO 2 migration, oil recovery, and mechanical deformation within caprock and on faults is a challenging problem in large-scale storage-enhanced oil recovery operations due to intersecting faults, multiphase flow effects, and wells with complex production-injection schedule. We develop and demonstrate a methodology based on our coupled modeling framework to monitor the movement of CO 2 , hydrocarbons and water, and the associated evolution in mechanical stability of faults during CO 2 storage-enhanced oil recovery in the Farnsworth Unit oil field in Texas, United States. The methodology honors geological, geophysical, and production-injection data acquired in the field over six decades. Differential depletion from hydraulically isolated fault compartments followed by water and CO 2 injection-induced overpressure causes volumetric contraction and expansion of the reservoir, and changes in the total and effective stresses in the overburden-reservoir-underburden complex. CO 2 migrates upward to accumulate near top of the geologic structure, and water migrates downward to pressurize the faults. Three-dimensional changes in the pressure and stress fields in the system lead to changes in the shear and effective normal tractions on three major faults compartmentalizing the field. Evolution in fault tractions is used to compute the evolution in the Coulomb failure function of the faults to quantify induced-slip tendency under production and injection. We explain the spatial heterogeneity and time variability of Coulomb failure function in terms of well location heterogeneity and well rate variability.

58 GEOSCIENCES↗

Enhancing the distribution grid resilience using cyber-physical oriented islanding strategy

The increasing penetration of distributed generations enables an innovative operation paradigm that allows islanded operation to enhance the resilience of the distribution grid. In this study, a cyber-physical oriented islanding strategy is proposed by coordinating centralised and distributed control to achieve seamless islanding transition and operational flexibility in emergency conditions. A cyber-physical control structure is developed to mitigate various disturbances (e.g. emergencies or fluctuations) according to different operation conditions. Specifically, the distributed fault isolation and seamless islanding transition are coordinated to mitigate the outage caused by unplanned islanding, while a secondary control is proposed to support primary control by reducing the power fluctuations during islanded operation. With a rapid response speed, the local cyber-physical devices are coordinated to accomplish islanding separation by selecting a feasible islanded area even under an unplanned islanding situation. A field test was conducted on a practical distribution network in China, and the results demonstrated the effectiveness and feasibility of the proposed islanding strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

First Ever Polymer Flood Field Pilot to Enhance the Recovery of Heavy Oils on Alaska’s North Slope – Polymer Injection Performance

Alaska North Slope (ANS) holds an estimated 20-30+ billion barrel heavy oil resources, yet the development pace has been very slow due to high development costs and low oil recovery using conventional waterflood and EOR methods. The objective of this pilot is to perform a field experiment to validate the use of an advanced polymer flooding technology to unlock the vast heavy oil resources on ANS. The advanced polymer flooding technology combines polymer flooding, low salinity water flooding, horizontal wells, and if necessary, injection conformance control treatments into one integrated process to significantly improve oil recovery from heavy oil reservoirs. Two pairs of horizontal injection and production wells have been deployed in an isolated fault block of the Schrader Bluff heavy oil reservoir at the Milne Point Field to conduct a polymer flood pilot. The pilot will acquire scientific knowledge and field performance data to optimize polymer flood design in the Schrader Bluff heavy oil reservoirs on ANS. Polymer injection started on August 28, 2018 using a custom made polymer blending and pumping unit. This paper focuses on the facility setup and polymer injection performance into the horizontal injectors drilled and completed in the Schrader Bluff heavy oil reservoir. Partially hydrolyzed polyacrylamide (HPAM) polymer was selected and the initial target viscosity was set at 45 centipoise. Polymer injection rate was set at 2200 bbl/day for one injector (J-23A) and 1200 bbl/day for the other (J-24A) based on production voidage. Injection pressure was controlled at below fracture pressure to prevent fracturing the reservoir and causing fast breakthroughs. Step rate and pressure falloff tests indicate that short term polymer injectivity is similar to water injectivity, which means that injectivity is mostly controlled by fluid mobility deep in the reservoir rather than that in the vicinity of the injection wellbore. Long term injection data indicate that polymer injectivity has been decreasing in both injectors as the reservoir is filled by polymer. No polymer has been observed in the production stream 7 months after the start of polymer injection compared with a 3-month breakthrough time with waterflood. This indicates that polymer significantly delays breakthrough time which will lead to increased sweep efficiency.

Ning, Samson↗

First Ever Polymer Flood Field Pilot - A Game Changer to Enhance the Recovery of Heavy Oils on Alaska’s North Slope

The development pace of Alaska’s vast, 20-25 billion barrels, heavy oil resources has been very slow due to high development costs and low oil recovery using conventional waterflood, and the impracticality of deploying thermal methods due to the presence of continuous permafrost. Although, polymer flooding has attracted attention and has become a promising EOR technique in heavy oil reservoirs due to the extensive application of horizontal wells and advancement of polymer flooding technology, no field tests have been performed to date in Alaska’s underdeveloped heavy oil reservoirs. The overall objective of this research is to perform a field experiment to validate the use of polymer flooding for extracting heavy oil in Alaska’s challenging environment. Two pre-existing pairs of horizontal injection and production wells in an isolated fault block of the Schrader Bluff heavy oil reservoir at the Milne Point Field are currently being used for the field experiment. Hydrolyzed polyacrylamide (HPAM) polymer injection started on August 28, 2018 at 600 ppm (4 cP viscosity) concentration ramping up to 1,800 ppm (45 cP viscosity) over a three week time period, and has been maintained at an average concentration of ~1,800 ppm. Current injection rates in the two horizontal injectors are ~2,200 and 600 bwpd. Laboratory experiments to determine the polymer retention, optimum water salinity, synergistic effects of water salinity and polymer, and handling of produced fluids, in support of the field experiment, are currently ongoing. Similarly, reservoir simulation of coreflood behavior and history match of previous waterfloods to predict polymer flood performance in the project area are also conducted in parallel. The field data and scientific knowledge that have been collected since the start of the injection indicates that the field pilot is performing as predicted. To date, no unexpected injectivity issues or polymer breakthrough have been encountered, and the two horizontal producers are showing positive response to the polymer injection, resulting in incremental increase in oil production rate. Since the research is still in its early stages, selected field, laboratory and simulation results are presented and discussed to highlight the integrative approach adopted in this first ever polymer flood field pilot in Alaska.

02 PETROLEUM↗