At least 19 records

Fault isolation and fault-tolerant control for nonlinear stochastic distribution control systems with multiplicative faults

Here, in this paper, a fault isolation, diagnosis and fault tolerant control algorithm is proposed for nonlinear multiple multiplicative faults stochastic distribution control systems employing Takagi–Sugeno fuzzy system. To obtain the detailed fault information, a fault detection algorithm is introduced to discover the fault occurrence time. Then a fault isolation observer is built to produce the residual, and the error system is separated to subsystems affected only by disturbance and multiplicative faults. Moreover, a fault estimation scheme is presented to obtain the fault magnitude information. When faults occur, the system output probability density function will deviate from the desired distribution. So the model predictive control fault tolerant control scheme is needed to minimize the impact of faults as much as possible to make sure that the post fault output probability density function track the desired probability density function. The validity of the designed algorithm is demonstrated through a simulation example, where the fault tolerant control algorithm ensures that the system output probability density function still track the given output probability density function despite the complex case of multiple multiplicative faults occurring simultaneously.

42 ENGINEERING↗

Modelica-based system modeling for studying control-related faults in chiller plants and boiler plants serving large office buildings

System modeling is critical when studying operation faults in chiller plants and boiler plants. However, current fault models have difficulties faithfully representing the operation of chiller plants and boiler plants under the effects of those faults, especially the control-related ones. In this study, we present a systematic method to develop high-fidelity models for approximating the behaviors of chiller plants and boiler plants under faulty conditions. Compared to existing ones, the resulting fault models have two advantages: first, they better characterize the dynamic patterns in the system operation. In those models, control architecture and control logic are faithfully implemented. Thus, they can be used to study control-related faults, such as incorrect staging control due to sensor bias and mistuned feedback control. Second, they are readily extensible and can support large-scale investigations to explore different faulty conditions/scenarios. Those models are established in a hierarchical structure while modules in each layer can be redeclared and parameterized at upper layers. In such a case, modifications to the models can be realized through model modifiers and the process can be easily streamlined with scripts. We applied the proposed models in a comprehensive fault impact evaluation of the 13 control-related faults of chiller and boiler plants. In this evaluation, the proposed plant model is coupled with the EnergyPlus thermal load model to study the impact of various faulty scenarios. Based on the evaluation results, we identified the faults that have the most significant impacts on the operation of the chiller and boiler plants, respectively. We also found that the relationship between the impacts of the studied faults and the severity level of the faults are highly non-linear

Huang, Sen↗

Fault isolation and fault-tolerant control for Takagi-Sugeno fuzzy time-varying delay stochastic distribution systems

A fault isolation, estimation, and fault-tolerant control (FTC) scheme for nonlinear time-varying delay stochastic distribution control systems was presented in this paper. The Takagi-Sugeno fuzzy model was adopted to approach the nonlinear dynamics of time-varying delay systems. According to the output equivalence principle and Laplace transformation, an augmented state vector was given to solve the time-varying delay problem. When multiple actuator faults and interference occur simultaneously, fault detection, isolation and fault estimation was designed to obtained the fault information. To decouple faults and obtain the value and location information of the fault, the system was separated into two parts through the designed multiple conversion matrices, in which one subsystem was only affected by one actuator fault. This has simplified the design of fault isolation and estimation. A adaptive observer for fault estimation was given. Then, fault information such as the time, location, and size was determined. The observer gain matrices were calculated using linear matrix inequality (LMI). When a fault was detected and diagnosed, a FTC algorithm was devised using the proportional-integral control scheme to compensate the fault as much as possible. It has been shown that even if multiple faults actuator occurred simultaneously, the FTC controller still ensured the output probability density function of the system traced the desired probability density function when a fault occurred. Finally, the expected results were obtained through the simulation example, which confirmed the effectiveness of the method.

42 ENGINEERING↗

Effects of multiple simultaneous faults on characteristic fault detection features of a heat pump in cooling mode

Faults in air-cooled vapor compression air-conditioning systems are known to reduce performance, including efficiency, capacity, and lifespan. Their effects have been studied, and fault detection and diagnostic (FDD) methods have been developed as tools for field technicians to install or repair systems, or for monitoring to alert operators to the fault’s presence. Most of this work has focused on faults that occur singly. It is likely that in some systems, multiple faults occur simultaneously, but it is uncertain what effects this may have on diagnostics. Here, this paper describes a laboratory study of a split system air source heat pump in which combinations of two, three, and four simultaneous faults occur. The study includes all combinations of: improper evaporator airflow; overcharge or undercharge of refrigerant; liquid line restrictions; and non-condensable gas in the refrigerant, each at multiple fault intensities. Fault features – those characteristics that can be determined from measurements, for use in diagnostics – are analyzed, and the key fault features are presented. A robust existing method for determining refrigerant charge, the virtual refrigerant charge sensor (VRC) is tested using the multiple fault data, in order to understand how its performance is impacted by the combined faults. The VRC performs well, typically able to correctly determine whether a system is undercharged or overcharged, but the magnitude estimates are impacted. The results suggest that simple subcooling-based methods of charging a system are likely to provide unsatisfactory results when other faults are present.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On the Interplay Between Distributed Bulk Plasticity and Local Fault Slip in Evolving Fault Zone Complexity

Abstract We numerically investigate the role of plastic strain accumulation on the mechanical response of a planar strike‐slip fault. Our models show that fault‐zone strength significantly impacts the ensuing sequence of earthquakes. Weaker fault zones accumulating more plastic strain promote more complexity in the seismicity pattern through aperiodic earthquake occurrences and intermittent episodes of rupture and arrest. However, if the fault zone strength is high enough, the overall earthquake sequence is characterized by periodic fault‐spanning events. We find that both the fault normal stress and the fault geometric profile evolve throughout the earthquake sequence, suggesting a self‐roughening mechanism. Despite the significant impact of plasticity on the fault response, the width of the plastically deforming region in the fault zone is small compared to the fault length. Our results suggest a rich behavior in dynamically evolving fault zones and support the need for further high‐resolution studies of the highly non‐linear near‐fault region.

Geology↗

Relationships between fault characteristics and seismic responses in a large lab-scale tri-axial injection test conducted on a faulted Castlegate Sandstone

Here to investigate mechanisms causing microseismicity (M w < 2) at a CO 2 injection site, a large-scale triaxial block experiment was carried out on a faulted (saw-cut) cubic-meter of Castlegate Sandstone. The experiment consisted of injection tests at varying differential stresses, while monitoring and recording pore pressure and acoustic emissions (AEs). During the experiment, ~33,000 AEs and ~14 mm of horizontal displacement/slip, like a strike-slip fault movement, occurred. To understand the AE responses and ascertain fault characteristics near the located AEs, we modeled the topography of the fault surface, fault aperture, and fault-gouge thickness using pre- and post-experiment laser scans of the fault surface on each half of the block. Additionally, we characterized surface roughness parallel and perpendicular to slip. Models show crushing and flattening of the fault surfaces can be linked to the spatiotemporal distribution of AEs within 50 mm of the fault surface. Approximately 65% of AEs were in areas with small aperture (≤300 μm); thicker fault gouge was observed in adjacent areas with wider aperture and shows a two-fold reduction in grain size relative to unaltered Castlegate Sandstone. This work provides a conceptual understanding on fault surface evolution, which can be applied towards modeling of seismic slip.

58 GEOSCIENCES↗

Fluid migration in low-permeability faults driven by decoupling of fault slip and opening

Understanding the response of faults to the injection of high-pressure fluids is important for several subsurface applications, for example, geologic carbon sequestration or energy storage. Lab-based experiments suggest that fluid injection can activate fault slip and that this slip can lead to increased fluid transmission along low-permeability faults. Here we present in situ observations from a cross-borehole fluid-injection experiment in a low-permeability shale-bearing fault, which show fault displacement occurring before fluid-pressure build-up. Comparing these observations with numerical models with differing permeability evolution histories, we find that the observed variation in fluid pressure is best explained by a change in permeability only after the fault fails and slips beyond the pressurized area. Once fluid migration occurs along the fault as a result of slip-induced permeability increase, the fault experiences further opening due to a decrease in the effective normal stress. We then suggest that decoupling of fault slip and opening, leading to a rapid increase in fluid pressurization following the initial fault slip, could be an efficient driver for fluid migration in low-permeability faults.

58 GEOSCIENCES↗

Rupture Jumping and Seismic Complexity in Models of Earthquake Cycles for Fault Stepovers with Off-Fault Plasticity

ABSTRACT Fault stepovers are prime examples of geometric complexity in natural fault zones that may affect seismic hazard by determining whether an earthquake rupture continues propagating or abruptly stops. However, the long-term pattern of seismicity near-fault stepovers and underlying mechanisms of rupture jumping in the context of earthquake cycles are rarely studied. Leveraging a hybrid numerical scheme combining the finite element and the spectral boundary integral methods, FEBE, we carry out fully dynamic simulations of sequences of earthquakes and aseismic slip for both compressive and tensile stepovers with off-fault plasticity. We consider a rate-and-state friction law for the fault friction and pressure-sensitive Drucker–Prager plasticity for the off-fault bulk response. We observe that the accumulation of plastic deformation, an indication of off-fault damage, is significantly different in the two cases, with more plastic deformation projected in the overlapping region for the tensile stepover. The seismic pattern for a tensile stepover is more complex than for a compressive stepover, and incorporating plasticity also increases complexity, relative to the elastic case. A tensile stepover with off-fault plasticity shows rupture segmentation, temporal clustering, and frequent rupture jumping from one fault to another. These results shed light on possible mechanisms of rupture jumping in fault stepovers as well as the long-term evolution of the fault zone.

Geochemistry & Geophysics↗

Analysis of Automated Fault Detection and Diagnosis Records as an Indicator of HVAC Fault Prevalence: Methodology and Preliminary Results

Faults in commercial buildings can cause energy waste and other performance problems such as reduced occupant comfort, reduced equipment longevity, and increased noise. However, it is currently unknown how commonly faults occur in different equipment types. A method has been developed to estimate the prevalence of faults in air handling units, air terminal units, and rooftop units. This method includes two types of data. The first is data from several automated fault detection and diagnostics (AFDD) software technologies. This type of data provides a large sample that represents a wide range of building types, geographical locations, and equipment types. It includes fault diagnoses from thousands of buildings around the United States, as well as anonymized metadata describing the building and equipment characteristics. The number of fault records is in the order of 107. However, despite the size and richness of the data sample, this data contains some degree of inaccuracy, i.e., false positive and false negative findings. Therefore, the study includes a second type of data, coming from manual inspection of buildings that have had the same AFDD methods applied to them (from the commercial AFDD offerings). Since the field tests are conducted in buildings with AFDD-generated fault prevalence data, they can be combined with the larger sample size to provide insight into the potential biases or lower sensitivity of the AFDD data. Once a library of fault prevalence data is built, it will be studied to provide further insight into the drivers of fault prevalence, for example, whether prevalence is correlated with building type, geographical location (which is tied to climate and to utility rates), building size, etc. This paper describes the methods developed for this study and illustrates them with preliminary data. It discusses some of the challenges of harmonizing disparate outputs from multiple AFDD vendors, application of a unifying fault taxonomy, and fault prevalence metrics.

Ebrahimi Fakhar, Amir↗

The Variable Continuous Bimaterial Interface in the San Jacinto Fault Zone Revealed by Dense Seismic Array Analysis of Fault Zone Head Waves

Key factors controlling earthquake ruptures include fault geometry, continuity, and seismic velocity structure around the fault. We present a novel tool that better informs deep bimaterial fault geometry embedded in distributed damage and seismicity, associated velocity contrasts across the fault, and their correlations with surface complexities. The method employs fault zone head and direct body waves and is applied to recordings from five spatiotemporally different seismic arrays along the complex San Jacinto fault zone (SJFZ) in southern California. We detect and distinguish these signals based on instantaneous phase coherence and relative energy in a cascading manner from one scale array to another. The analysis reveals a >70-km long continuous bimaterial interface within the SJFZ with several deep northeast dipping fault segments. The northern SJFZ, for instance, locates ~7 km northeast of its surface expression at 18-km depth. P-wave velocity contrasts range from near 0% to >15%, consistent with other bimaterial faults, and differ by a few % depending on fault-array azimuth, implying directional-dependent velocity contrasts. S-wave head waves and velocity contrasts are also imaged for the first time at the southern SJFZ, averaging to 2.9% in agreement with tomography results. The imaged geometry and continuity suggest the SJFZ initiated along remnant tectonic structures and translates to a rupture potential of M > 7.2, i.e., the sizes of its largest paleo-earthquakes. The P and S contrasts, and their ratios, have important implications for earthquake rupture speed, mode, directivity, and frictional heating along the SJFZ and other major faults globally.

58 GEOSCIENCES↗

An ontology-based fault generation and fault propagation analysis approach for safety-critical computer systems at the design stage

Abstract Fault propagation analysis is a process used to determine the consequences of faults residing in a computer system. A typical computer system consists of diverse components (e.g., electronic and software components), thus, the faults contained in these components tend to possess diverse characteristics. How to describe and model such diverse faults, and further determine fault propagation through different components are challenging problems to be addressed in the fault propagation analysis. This paper proposes an ontology-based approach, which is an integrated method allowing for the generation, injection, and propagation through inference of diverse faults at an early stage of the design of a computer system. The results generated by the proposed framework can verify system robustness and identify safety and reliability risks with limited design level information. In this paper, we propose an ontological framework and its application to analyze an example safety-critical computer system. The analysis result shows that the proposed framework is capable of inferring fault propagation paths through software and hardware components and is effective in predicting the impact of faults.

97 MATHEMATICS AND COMPUTING↗

Impacts of common faults on an air conditioner with a microtube condenser and analysis of fault characteristic features

Split system air conditioners are widely used to cool residential buildings, because of their low cost and simplicity. However, their efficiency is impacted by installation faults, which include: improper refrigerant charge (undercharge or overcharge), improper evaporator airflow, liquid line restrictions (LL), and the presence of non-condensable gas (NC) in the refrigerant. No known previously published research has studied the effect of these four faults on a system equipped with a microtube condenser, which has smaller tube size than a traditional condenser and therefore holds less refrigerant charge, but has a different configuration than a microchannel. Furthermore, very few have studied the impacts of LL and NC. Herein this paper describes laboratory fault tests of a microtube-equipped system, compares the fault impacts with those of a traditional system, and considers the characteristic fault features. The tested system uses R-410A refrigerant and has a scroll compressor, a fixed orifice expansion device, and two fin-tube heat exchangers. The tests were carried out under steady operation with a range of fault intensities and operating conditions. The microtube system’s performance degradation from faults is similar to systems with traditional heat exchangers, despite the reduced capacity to hold refrigerant charge.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of the Phase-to-Ground Fault Apparent Admittance Method with Phase/Ground Boundaries to Detect Types of Electrical Faults for Protective Relays Using Signature Library and Simulated Events

Protective relays in electric power grids recognize the types of electrical faults in a few seconds. The most common detection method to detect the types of electrical faults is based on measuring the angle between the zero and negative sequence currents. However, it is not completely accurate because the phase to phase ground and phase to ground electrical faults could have the same detection conditions. Therefore, engineers need to plot the events after an electrical fault to observe the nature of the incidents in detail. In this study, the phase to ground fault apparent (PGFA) admittance method with phase/ground boundaries identified the types of electrical faults located in distribution power lines and feeders. This method was based on measuring the PGFA admittance magnitudes for the faulted and non-faulted phases, resulting in greater than zero and near zero, respectively. The PGFA admittance algorithm was built with MATLAB/ Simulink software and tested with signature library and grid simulation events. The PGFA method with phase/ground boundaries was evaluated with the confusion matrix. The measured and predicted values matched in more than 90% of the tests, and the PGFA admittance method with phase/ground boundaries presented an accuracy of 94.3% and a precision of 100%.

Piesciorovsky, Emilio↗

From fault-detection to automated fault correction: A field study

A fault detection and diagnostics (FDD) tool, as addressed by this study, is a tool that continuously identifies the presence of faults and efficiency improvement opportunities through a one-way interface to the building automation system and the application of automated analytics. Although FDD tools can inform operators of building operational faults, currently an action is always required to correct the faults to generate energy savings. Fault auto-correction integrating with commercial FDD technology offerings can close the loop between the passive diagnostics and active control, increase the savings generated by FDD tools, and reduce the reliance on human intervention. This paper presents the field study of seven fault auto-correction algorithms implemented in commercial FDD platforms. Implementation includes software changes in the FDD tools and additional controls hardware or software changes in the BAS that were required to enable the execution of different types of auto-correction algorithms in real buildings. The routines successfully and automatically correct faults and improve the operation of large built-up Heating, Ventilation, and Air Conditioning (HVAC) systems, common in most commercial buildings. The auto-correction algorithms are tested across four buildings and three different building automation systems, following a rigorous procedure to make sure they work properly and do not negatively impact the system and building occupants. Finally, technology benefits, market drivers, and scalability changes are drawn from the implementation effort and test results, to drive future research and industry engagement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Direct Bayesian inference for fault severity assessment in Digital-Twin-Based fault diagnosis

For applications in condition-based maintenance of nuclear systems, the assessment of fault severity is crucial. In this work, we developed a framework that allows for direct inference of the probability distributions of possible faults in a system. Here, we employed a model-based approach with model residuals generated from analytical redundancy relations provided by physics-based models of the system components. From real-time sensor readings, the values of the model residuals can be calculated, and the posterior probability distributions of the faults can be computed directly using the methods of Bayesian networks. From the posterior distribution of each fault, one can estimate the fault probability based on a chosen threshold and assess the severity of the fault. By eliminating the discretization and simplifications in middle steps, this approach allows us to leverage the available computational resources to provide more accurate fault probability estimates and severity assessments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗