Overall Cooling Effectiveness With Internal Serpentine Channels and Optimized Film Cooling Holes

Abstract The overall cooling effectiveness for gas turbine airfoils is a function of the combined cooling due to internal cooling configurations and film cooling configurations. Typically, film cooling configurations are evaluated independent of the cooling effects of the internal feed channels, generally based on adiabatic effectiveness measurements. In this study, we consider the coupled effects of internal cooling and film cooling configurations through measurements of overall cooling effectiveness for film cooling holes fed by a coflow/counterflow channel and a serpentine channel. A film cooling hole designed by adjoint optimization techniques (X-AOpt) is compared to a standard-shaped hole with 7 deg forward and lateral expansions (7-7-7 SI). Experiments without film cooling showed that the serpentine channel had 35–50% greater overall cooling effectiveness than the straight, coflow channel. Experiments with the X-AOpt hole combined with a serpentine channel showed an area-averaged overall cooling effectiveness of ϕ¯¯=0.58, which was a 70% increase compared to the overall cooling effectiveness of the serpentine channel without film cooling. When the X-AOpt hole was fed with a coflow channel with similar coolant mass flowrate, the overall cooling effectiveness was ϕ¯¯=0.44, i.e., 30% lower than when using the serpentine channel. Interestingly, adiabatic effectiveness measurements with the X-AOpt holes showed a more uniform hole-to-hole performance when using the serpentine channel compared to the coflow channel.

Engineering↗

The Effects of Channel Supplies on Overall Film-Cooling Effectiveness

Abstract Cooling components in the hot section of a gas turbine are essential to component durability. Common methods of cooling include rib turbulators in internal passages and film cooling on external surfaces. The holes that produce the film cooling are fed from the internal channels often containing ribs. Consequently, there is an interdependence of internal heat transfer and external film cooling. The purpose of this study was to obtain a better understanding of the interaction of ribs and film cooling. To quantify the cooling performance, the surface temperatures were measured, from which overall effectiveness was calculated. For the experiments, additively manufactured test coupons were made of Inconel 718 to match engine Biot numbers. These test coupons had internal feed channels with and without ribs and had both cylindrical holes and meter-diffuser-shaped holes with 15 deg lateral expansion angles and a 1 deg forward expansion angle. A single rectangular channel was one type of feed channel. The other type of feed channel was individual circular channels, with each circular channel supplying an individual film-cooling hole. The experimental results showed that the circular individual channels have 80% higher baseline overall effectiveness than the single rectangular channels without any film cooling. Ribbed turbulators without film cooling also increased the overall effectiveness by 21% for single rectangular channels and by 29% for the circular individual channels compared to the respective non-ribbed channels. While the film cooling increased the overall effectiveness of all geometries, the single rectangular channels had increased overall effectiveness levels by up to twice that of the no film-cooling case. On average, the single rectangular channels had an 80% improvement from film cooling, whereas the individual channel feeds, on average, had only a 50% improvement, given their high baseline effectiveness levels.

Engineering↗

Simple Heat Transfer Model for Film Cooling Applications

This report describes the development of a simple engineering model for film cooling. This model is used to derive a relationship between local wall temperature variations and key cooling performance parameters like local heat transfer coefficients and film effectiveness. This relation and method new and different from previously published models. The scope of this report includes the derivation of regression model equations for a flat plate with and without film cooling. The model equation for a flat plate without film cooling can be used to estimate local heat transfer coefficients using surface temperatures measured from infrared thermography. The model equation for the flat plate with film cooling can be used to estimate film cooling effectiveness, $η_f$, and heat transfer augmentation from the film cooling jet(s).

42 ENGINEERING↗

Revisiting Dimensionless Parameters Quantifying Film Cooling

This paper describes a dimensional analysis of film cooling effectiveness for crossflow-fed film cooling holes. An additional parameter is required to account for swirl inside the film cooling hole. Computations based on Reynolds-Averaged Navier-Stokes (RANS) show significant improvements in cooling effectiveness when the coolant supply velocity is decreased. NETL experimental data was used to validate these computational results.

advanced gas turbines↗

Experimental and Computational Investigation of Shaped Film Cooling Holes Designed to Minimize Inlet Separation

Abstract Film cooling is used to protect turbine components from the extreme temperatures by ejecting coolant through arrays of holes to create an air buffer from the hot combustion gases. Limitations in traditional machining meant film cooling holes universally have sharp inlets, which create separation regions at the hole entrance. The present study uses experimental and computational data to show that these inlet separation are a major cause of performance variation in crossflow fed film cooling holes. Three-hole designs were experimentally tested by independently varying the coolant velocity ratio (VR) and the coolant channel velocity ratio (VRc) to isolate the effects of crossflow on hole performance. Leveraging additive manufacturing (AM) technologies, the addition of a 0.25D radius fillet to the inlet of a 7-7-7 shaped hole is shown to significantly improve diffuser usage and significantly reduce variation in performance with VRc. A second AM design used a very large radius of curvature inlet to reduce biasing caused by the inlet crossflow. Experiments showed that this “swept” hole design did minimize biasing of the coolant flow to one side of the shaped hole, and it significantly reduced variations due to varying VRc. RANS simulations at six VR and three VRc conditions were made for each geometry to better understand how the new geometries changed the velocity field within the hole. The sharp and rounded inlets were seen to have very similar tangential velocity fields and jet biasing. Both AM inlets created more uniform, slower velocity fields entering the diffuser. The results of this article indicate that large improvements in film cooling performance can be found by leveraging AM technology.

Engineering↗

Effects of Downstream Vortex Generators on Film Cooling a Flat Plate Fed by Crossflow

Counter-rotating vortices, formed by the interaction of film-cooling jets and the hot gas flow, adversely affect the performance of conventional film-cooling designs. Downstream vortex generators have been shown to improve cooling effectiveness by mitigating the effects of the counter-rotating vortices and by deflecting the cooling jet laterally. In this study, computational and experimental methods were used to examine how cylindrical film-cooling holes (D = 3.2 mm, L/D = 6, p/D = 3, α = 30 deg) with and without downstream vortex generators perform when the coolant supply channel is perpendicular to the direction of the hot gas. For this study, the hot gas had a temperature of 650 K and an average Mach number of 0.23. Here, the hot-gas-to-coolant temperature ratio was 1.9, and two blowing ratios (0.75 and 1.0) were studied. Results from the computational fluid dynamics study show how crossflow affects the interaction between the film-cooling jet and hot gas flow with and without downstream vortex generators. The experimental measurements were based on infrared thermography in a conjugate heat transfer environment. Results were obtained for film-cooling performance in terms of overall effectiveness, film effectiveness, and local heat transfer coefficients. The downstream vortex generators can increase the laterally averaged effectiveness by a factor of 1.5 relative to cylindrical holes, but this higher performance is restricted to low crossflow velocities and higher blowing ratios.

17 WIND ENERGY↗

Effects of Downstream Vortex Generators on Film Cooling a Flat Plate Fed by Crossflow

This presentation describes experimental and CFD results of a novel idea to improve film cooling effectiveness. This concept involves downstream vortex generators to control counter-rotating vortices that can degrade discrete film cooling jets. The performance can be influenced significantly by how the coolant is supplied to the film cooling holes. In this paper, the effects of a coolant supply channel that is normal to the hot gas path are investigated and discussed.

Straub, Douglas↗

Assessment of Machine Learning Wall Modeling Approaches for Large Eddy Simulation of Gas Turbine Film Cooling Flows: An a Priori Study

Here, in this work, a priori analysis of machine learning (ML) strategies is carried out with the goal of data-driven wall modeling for large eddy simulation (LES) of gas turbine film cooling flows. High-fidelity flow datasets are extracted from wall-resolved LES (WRLES) of flow over a flat plate interacting with the coolant flow supplied by a single row of 7-7-7 shaped cooling holes inclined at 30 degrees with the flat plate at different blowing ratios (BR). The WRLES are performed using the high-order Nek5000 spectral element computational fluid dynamics (CFD) solver. Light gradient boosting machine (LightGBM) is employed as the ML algorithm for the data-driven wall model. Parametric tests are conducted to systematically assess the influence of a wide range of input flow features (velocity components, velocity gradients, pressure gradients, and fluid properties) on the accuracy of ML wall model with respect to prediction of wall shear stress. In addition, the use of spatial stencil and time delay is also explored within the ML wall modeling framework. It is shown that features associated with gradients of the streamwise and spanwise velocity components have a major impact on the prediction fidelity of wall model, while the effect of gradients of wall-normal velocity component is found to be negligible. Moreover, adding flow feature information from an x-y-z spatial stencil significantly improves the ML model accuracy and generalizability compared to just using local flow features from the matching location. Overall, highest prediction accuracy is achieved when both spatial stencil and time delay features are incorporated within the data-driven wall modeling paradigm.

33 ADVANCED PROPULSION SYSTEMS↗

Integrated Turbine Component Cooling Designs Facilitated by Additive Manufacturing and Optimization

This research program involved the development of improved gas turbine cooling by optimizing the combined internal and film cooling configurations used for turbine blades and vanes. Improved cooling of turbine airfoils allows the gas turbines to be operated at higher temperatures which improves efficiency for gas turbine-based power generation. This also facilitates operation with hydrogen-based fuels which inherently generate higher operating temperatures. Designs of the new cooling configurations were based on the added geometric flexibility that is available when using metal additive manufacturing techniques. When making these designs, adjustments were made to account for imperfections occurring in the metal additive manufacturing process. New designs for film cooling holes were developed using computational adjoint gradient optimization techniques which generated a unique film cooling hole with 70% greater film cooling effectiveness compared to conventional shaped film cooling holes. A major factor in improving the film cooling effectiveness were small external protrusions on either side of the new hole which generated vortices that pushed coolant towards the surface and increased the lateral spreading of the coolant. Our studies also included optimization of film cooling holes that can be built with conventional manufacturing techniques and optimizing the internal coolant channels that supply coolant to the film cooling holes. Various internal coolant channel shapes were investigated and designs that maximized the cooling of the airfoil while minimizing pressure losses in the channel flows were identified. Testing and verification of the performance of the final configurations was done with a transonic wind tunnel facility which allowed testing at engine realistic high velocities. Final testing of the combined internal and film cooling configurations was done by incorporating the configurations in Penn State’s National Experimental Turbine (NExT) vane. These tests confirmed the enhanced overall cooling effectiveness provided by the new cooling configuration designs.

03 NATURAL GAS↗

Simplified Model and Approach to Transform Infrared Surface Temperature to Film Effectiveness in a Conjugate Heat Transfer Experiment

In the pursuit of more efficient gas turbines, film cooling is a critical technology. This article describes a simplified engineering model based on a one-dimensional thermal resistance network. The model is used to relate film-cooling effectiveness and heat transfer augmentation to local overall cooling effectiveness in a conjugate flat plate experiment. Here, this article presents experimental proof-of-concept data to demonstrate the potential for this model. In contrast to previous approaches, neither the wall heat flux nor the adiabatic wall temperature is required to estimate the local film-cooling performance parameters. The model predicts surface temperatures that are within the experimental uncertainties over the range for which the model is trained and to within five percent when the model is extrapolated to higher coolant channel Reynolds numbers. This article is relevant to conjugate test rigs that can measure the hot-surface temperature distribution with and without film cooling. This information may also be relevant to designers as a method to approximate surface temperatures or used as an approximate heat transfer model for optimization studies.

advanced turbines↗

A One-dimensional Heat Transfer Model for a Cooled Airfoil in a Direct-fired Supercritical CO 2 Turbine

A one-dimensional (1-D) heat transfer model was developed to predict the performance of a cooled airfoil for a supercritical carbon dioxide (sCO 2 ) turbine. The model included the effects of film cooling effectiveness, thermal barrier coating thickness, and internal Nusselt number augmentation. Trends for overall cooling effectiveness versus heat load parameter were obtained for over twelve unique thermal management schemes. The study found that adding a thermal barrier coating was the most effective scheme for increasing the airfoil overall cooling effectiveness. Internal cooling technologies have diminishing returns as the heat transfer coefficient augmentation increases past a factor of five, however the sensitivity of overall cooling effectiveness to heat transfer augmentation scales by a factor of 1.3 when a thermal barrier coating is introduced. Film cooling is seen as a long-term research area which will be inevitably explored as direct sCO 2 systems develop a market presence. However, the model indicates that realizable film cooling effectiveness levels yield a smaller improvement in overall cooling effectiveness than a thermal barrier coating.

42 ENGINEERING↗

Simplified Model and Approach to Transform Infrared Surface Temperature to Film Effectiveness in a Conjugate Heat Transfer Experiment

This paper describes a simplified engineering model based on a one-dimensional thermal resistance network. The model is used to develop a new method to relate film cooling effectiveness and heat transfer augmentation to local overall cooling effectiveness in a conjugate flat plate experiment. This paper presents experimental proof-of-concept data to demonstrate the potential for this model. In contrast to previous approaches, neither the wall heat flux nor the adiabatic wall temperature is required to estimate the local film cooling performance parameters. The model predicts surface temperatures that are within the experimental uncertainties over the range for which the model is trained, and to within five percent when the model is extrapolated to higher coolant channel Reynolds numbers. This paper is relevant to conjugate test rigs that can measure the hot surface temperature distribution with and without film cooling. This information may also be relevant to designers as a method to approximate surface temperatures or used as an approximate heat transfer model for optimization studies.

advanced gas turbines↗

Overall Cooling Effectiveness of Internally Cooled Additively Manufactured Blades

Power generation gas turbine blades must utilize highly effective cooling schemes to withstand moderate heat loads for long operating times. Prior work indicates that gas turbines in the 5-10 MW range primarily utilize internal cooling to prevent further increase of aerodynamic losses that result from film cooling, but few studies focus solely on internal cooling. In this study, three additively manufactured internal cooling designs were tested in the 50 percent span section of the National Experimental Turbine (NExT) blade: a baseline cooling design with pin-fin arrays and rib turbulators, a double wall design with impingement jets and serpentine channels, and an incremental impingement design. The designs were tested in a high-speed linear cascade at exit Reynolds numbers ranging from 700,000 to 1,400,000 at an exit Mach of 0.8. In addition, freestream turbulence and build angle effects on cooling performance were studied.

gas turbine blades↗

Computational Study of Additively Manufactured Internally Cooled Airfoils for Industrial Gas Turbine Applications

Internal cooling features such as pin-fins, impingement jets, and rib-turbulators are necessary to keep turbine components cool, but if sufficiently advanced can potentially also eliminate the need for film cooling on turbine blades particularly in industrial gas turbines where temperatures are not extreme. Furthermore, by leveraging additive manufacturing, other advanced designs such as lattice and incremental impingement configurations are possible and have recently been experimentally tested. While the performance of such configurations has been quantified through means of overall cooling effectiveness, it is not as clear why certain designs were better than others, or what the mechanisms were behind the observed external cooling patterns. The purpose of this study was to computationally analyze different advanced turbine blade internal cooling designs previously tested by the National Energy Technology Laboratory.

CFD↗

Methods for Measuring and Computing the Reference Temperature in Newton’s Law of Cooling for External Flows

Newton’s law of cooling requires a reference temperature (𝑇 𝑟𝑒𝑓 ) to define the heat-transfer coefficient (ℎ). For external flows with multiple temperatures in the freestream, obtaining 𝑇 𝑟𝑒𝑓 is a challenge. One widely used method, referred to as the adiabatic-wall (AW) method, obtains 𝑇 𝑟𝑒𝑓 by requiring the surface of the solid exposed to convective heat transfer to be adiabatic. Another widely used method, referred to as the linear-extrapolation (LE) method, obtains 𝑇 𝑟𝑒𝑓 by measuring/computing the heat flux ($𝑞^{′′}_𝑠$) on the solid surface at two different surface temperatures (𝑇 𝑠 ) and then linearly extrapolating to $𝑞^{′′}_𝑠$ = 0. A third recently developed method, referred to as the state-space (SS) method, obtains 𝑇 𝑟𝑒𝑓 by probing the temperature space between the highest and lowest in the flow to account for the effects of 𝑇 𝑠 or $𝑞^{′′}_𝑠$ on 𝑇 𝑟𝑒𝑓 . This study examines the foundation and accuracy of these methods via a test problem involving film cooling of a flat plate where $𝑞^{′′}_𝑠$ switches signs on the plate’s surface. Results obtained show that only the SS method could guarantee a unique and physically meaningful 𝑇 𝑟𝑒𝑓 where 𝑇 𝑠 =𝑇 𝑟𝑒𝑓 on a nonadiabatic surface $𝑞^{′′}_𝑠$ = 0. The AW and LE methods both assume 𝑇 𝑟𝑒𝑓 to be independent of 𝑇 𝑠 , which the SS method shows to be incorrect. Though this study also showed the adiabatic-wall temperature, 𝑇 𝐴𝑊 , to be a good approximation of 𝑇 𝑟𝑒𝑓 (<10% relative error), huge errors can occur in ℎ about the solid surface where |𝑇 𝑠 −𝑇 𝐴𝑊 | is near zero because where 𝑇 𝑠 =𝑇 𝐴𝑊 , $𝑞^{′′}_𝑠$ ≠ 0.

Newton's law of cooling↗

Active and passive cooling approaches for a Southern California residential community

This study assesses cooling strategies in a low-income community in Southern California that lacks air conditioning and struggles with heat and air pollution. We used an urban building energy model and an electric distribution system model to evaluate active and passive cooling measures. The most effective space cooling measures were high-performance air-source heat pumps, cool coatings, window films, and harnessing the space cooling effect from heat pump water heaters. The results show that combining heat pump water heaters with window films and cool coatings reduces heat index hazard hours within buildings by 95 % to 99 % but increases total energy costs (equipment costs plus changes in utility bills) by 20 % to 60 % where the higher end includes building electrical upgrades. These measures also led to increased space heater use during colder months to avoid overcooling. Replacing conventional heaters with air source heat pumps eliminated unsafe indoor temperatures and reduced total energy use, but increased cost by 125 % to 150 %. In total, using heat pumps for space and water heating could reduce primary energy use by up to 57 %. The higher cost of active and passive cooling measures can be mitigated by existing and emerging incentive programs, especially those that support heat pumps. Electric distribution upgrades to support community electrification are estimated to increase utility costs by $\$$25 to $\$$40 per ratepayer per year. The results underscore the potential and challenges of adapting building infrastructure in communities at risk from climate and environmental stressors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗