Search NASA⌕ Search

SEARCH · Search NASA

Results for “Filter pack”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Angularly resolved spectral reconstruction of x rays via filter pack attenuation

We have designed a new filter pack array to measure angular variations in x-ray spectra during a single shot. The filter pack was composed of repeating identical columns of aluminum and copper filters of varying thicknesses. These columns were located at different positions to measure the spectrum at each corresponding angle. This array was utilized in an experiment to measure the energy evolution of betatron x rays in a laser wakefield accelerator by curving the wakefield with a transverse density gradient, streaking the x rays across the array in front of an x-ray charge-coupled device (CCD) camera. After subtracting the background and “flattening” the image to remove spatial nonuniformities, a critical energy was calculated for each position that produced the best agreement with the measured signal. There was a clear change in critical energy with angle, shedding light on the dynamics of the electrons that traveled through the accelerator. Furthermore, these angles correspond to distinct emission times, covering a timescale of tens of picoseconds. The filter pack was capable of recovering these angular details without the impact of errors introduced by shot-to-shot variability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-Phase Flow in Packed Beds, Filters and Orifices: Summary of Findings of the Packed Bed Reactor Experiment Onboard of the International Space Station

Understanding the hydrodynamics of adiabatic two-phase flows in packed bed reactors enables the optimization of chemical reaction rates and products that crucial in pharmaceuticals and energy production industries. Additionally, this understanding aids in designing more efficient and compact reactors and reducing space and resource requirements. Insights gained from studying and understanding such flows in microgravity contribute to advancements of space technologies and the enhancement of our capabilities for undertaking future long duration safe, and sustainable space exploration missions. The objective of the Packed Bed Reactor Experiment series (PBRE and PBRE-2) was to develop a fundamental understanding of the hydrodynamics of adiabatic two-phase flows through porous media in microgravity. This work provides a description of the PBRE fluid system and presents the highlights of the PBRE and PBRE-2 previously flown with different packings and operated onboard of the International Space Station Microgravity Science Glovebox (ISS-MSG). These highlights include flow patterns and two-phase pressure drop, and the impact of capillary effects on pressure drop at various gas and liquid flow rates. This work also presents preliminary results from the Packed Bed Reactor Experiment-Water Recovery Series (PBRE-WRS) recently flown with filters and orifices, which was also operated on the ISS-MSG. The objective of the experiment is to validate hydrodynamic models at a range of gas and liquid flow rates pertinent to the operation of these test articles. The microgravity environment allows for measurement and observation of aspects of fluid dynamics that are unique when compared to observations made in full or partial gravity environments.

ISS↗

Submicron and Nanoparticulate Matter Removal by HEPA-Rated Media Filters and Packed Beds of Granular Materials

Contaminants generated aboard crewed spacecraft by diverse sources consist of both gaseous chemical contaminants and particulate matter. Both HEPA media filters and packed beds of granular material, such as activated carbon, which are both commonly employed for cabin atmosphere purification purposes have efficacy for removing nanoparticulate contaminants from the cabin atmosphere. The phenomena associated with particulate matter removal by HEPA media filters and packed beds of granular material are reviewed relative to their efficacy for removing fine (less than 2.5 micrometers) and ultrafine (less than 0.01 micrometers) sized particulate matter. Considerations are discussed for using these methods in an appropriate configuration to provide the most effective performance for a broad range of particle sizes including nanoparticulates.

Perry, J. L.↗

Establishing a silica gel zone in well annulus and evaluating its performance in blocking vertical water flow

Wells are often constructed for monitoring purposes with relatively long screen lengths (e.g., >10 m). Vertical water flows can occur within the artificial or natural filterpack annulus that surrounds the screened interval, bypassing packer assemblies installed inside the wellbore. Attempts to isolate discrete vertical zones during groundwater sampling are unsuccessful when annular flow occurs and lead to remedy decisions based on biased or incorrect interpretations. Blocking vertical annular water flow and contaminant transport will help obtain more accurate concentrations of contaminants from sampling in targeted depth intervals. The application of silica gels formed from the injected colloidal silica CS suspensions is a novel approach to minimize or prevent movement of vertical movement of groundwater in the surrounding filterpack annulus. In this work, we tested the feasibility of injecting CS suspensions to target locations and developed a modified CS formulation that is injectable and prevents gravity sinking. We studied the distribution and penetration of silica gel at laboratory scale in mock well annulus with surrounding formations. We evaluated the performance of the silica gel in blocking vertical water flow in the annulus and in minimizing chemical transport through the gel zone. CS suspension formulations have been defined that are ready for injection, stay in target locations, and form gel within desired time frames. Injection of CS suspensions achieved uniform distribution in a well annulus filter pack, fully occupied the annulus pore space, and penetrated the formation surrounding the filter packer with a sufficient distance to create a hydraulic annular seal when the injection was applied at a sufficient rate. The depth of penetration into the formation was dependent on the permeability contrast between the filter pack and the surrounding formation. Silica gel that formed in the annulus blocked vertical water flow and stopped the chemical transport through the gel zone. In conclusion, this research reveals that using CS suspension injection and sequential gelation (CS-GEL) is a promising technology for blocking vertical water flow and chemical transport through the filter pack in targeted zones within the annulus of long-screened well systems.

Colloidal silica suspension↗

Semivolatile Particulate Organic Material Southern Africa during SAFARI 2000

During August and September 2000, the University of Washington's Cloud and Aerosol Research Group (CARG) with its Convair-580 research aircraft participated in the Southern African Fire-Atmosphere Research Initiative (SAFARI) 2000 field study in southern Africa. Aboard this aircraft was a Particle Concentrator-Brigham Young University Organic Sampling System (PC-BOSS), which was used to determine semivolatile particulate material with a diffusion denuder sampler. Denuded quartz filters and sorbent beds in series were used to measure nonvolatile and semivolatile materials, respectively. Results obtained with the PC-BOSS are compared to those obtained with conventional quartz-quartz and Teflon-quartz filter pack samplers. Various 10-120 min integrated samples were collected during flights through the h e troposphere, in the atmospheric boundary layer, and in plumes from savanna fires. Significant fine particulate semivolatile organic compounds (SVOC) were found in all samples. The SVOC was not collected by conventional filter pack samplers and therefore would not have been determined in previous studies that used only filter pack samplers. The SVOC averaged 24% of the fine particulate mass in emissions from the fires and 36% of the fine particulate mass in boundary layer samples heavily impacted by aged emissions from savanna fires. Concentrations of fine particulate material in the atmospheric mixed layer heavily impacted by aged savanna frre emissions averaged 130 micrograms per cubic meter. This aerosol was 85% carbonaceous mated.

Eatough, D. J.↗

Filter Bed of Packed Spheres

Spheres sized and treated for desired sieve properties. Filter constructed from densely packed spheres restrained by screens. Hollow gas-filled plastic or metal spheres normally used. Manufactured within one percent or better diameter tolerance. Normally, all spheres in filter of same nominal diameter. Filter used as sieve to pass only particles smaller than given size or to retain particles larger than that size. Options available under filter concept make it easy to design for specific applications.

Elleman, D. D.↗

Effect of particle size on the capture of uranium oxide colloidal particles from aqueous suspensions via high-gradient magnetic filtration

The effectiveness of High Gradient Magnetic Filtration (HGMF) in capturing uranium oxide particles from suspensions was investigated in this study. Two sets of experiments were performed to evaluate the importance of size on the capture of uranium oxide particles. The first considered two batches sieved into size bins of< 5, 5–10, 10–15, and 15–20 µm, while the second was performed using two suspensions with diameters smaller than 1.0 µm and between 1.0 and 1.5 µm. Iron oxide experiments, with particles between 0.3 and 0.8 µm, were performed for calibration purposes. In all experiments, a surfactant (Triton-X100 or sodium dodecyl sulfate) was used to prevent particle aggregation and limit the influence of non-magnetic capture mechanisms. A magnetic field of approximately 1.1 Tesla was generated using a water cooled electromagnet. HGMF was performed using tubular filters packed with ferromagnetic stainless-steel wool. Of the initial four uranium oxide particle sizes, magnetic capture was only observed for particles with a diameter of less than 5 µm, while larger particles experienced no magnetic and minimal total capture. For particles with diameters smaller than 1.0 µm and between 1.0 and 1.5 µm, capture efficiencies increased by 39 ± 9% and 34 ± 6% respectively, solely due to the magnetic field. Although the magnetic force is proportional to particle diameter, the capture efficiency decreased as diameter increased. So these results suggest that Brownian diffusion, which is influential for micron sized particles and increases with decreasing particle size, is acting in conjunction with the magnetic force to influence the efficacy of HGMF for uranium oxide. This important finding underscores the effectiveness of Brownian diffusion in increasing the rate of collision between particles and collector fibers. A stochastic trajectory model was developed to incorporate the influence of Brownian motion on particle behavior and filter removal efficiency. Modeling results are discussed and compared for uranium and iron oxide particles.

42 ENGINEERING↗

High-resolution x-ray spectrometer for x-ray absorption fine structure spectroscopy

Two extended x-ray absorption fine structure flat crystal x-ray spectrometers (EFX’s) were designed and built for high-resolution x-ray spectroscopy over a large energy range with flexible, on-shot energy dispersion calibration capabilities. The EFX uses a flat silicon [111] crystal in the reflection geometry as the energy dispersive optic covering the energy range of 6.3–11.4 keV and achieving a spectral resolution of 4.5 eV with a source size of 50 μm at 7.2 keV. A shot-to-shot configurable calibration filter pack and Bayesian inference routine were used to constrain the energy dispersion relation to within ±3 eV. The EFX was primarily designed for x-ray absorption fine structure (XAFS) spectroscopy and provides significant improvement to the Laboratory for Laser Energetics’ OMEGA-60 XAFS experimental platform. The EFX is capable of performing extended XAFS measurements of multiple absorption edges simultaneously on metal alloys and x-ray absorption near-edge spectroscopy to measure the electron structure of compressed 3d transition metals.

47 OTHER INSTRUMENTATION↗

Applying colloidal silica suspensions injection and sequential gelation to block vertical water flow in well annulus: laboratory testing on rheology, gelation, and injection

We evaluated the application of silica suspension injection and sequential gelation to block vertical water flow in the annuli of long-screened wells. First, we studied the viscosity, rheological behavior, and gelation performance of colloidal silica suspensions in batch tests. Then, we tested the injection of silica suspensions and the water flow blocking efficiency of the later formed silica gel in column and bench-scale sandbox experiments. Micron-sized fumed powder silica suspensions and nanosized silica suspensions recovered from geothermal fluids were tested in this work. Fumed silica suspensions showed shear thinning, while nanosized silica suspensions exhibited Newtonian flow behavior. During the gelation process, the nanosized silica suspension changed from a Newtonian fluid to a shear thinning fluid while increasing its overall viscosity. At comparable concentrations, the nanosized silica suspensions have much lower viscosity than that of the fumed silica suspensions. Increases in the Na + concentration and silica particle concentration in these suspensions shortened the gelation time. Silica suspension gelation in sand columns completely blocked the water flow and sustained the injection pressure up to 50 psig (344.7 kPa). A silica suspension was successfully injected into the target zone in the annulus of a bench-scale sandbox mimicking long-screened wells in the field. The silica gel formed in the annulus effectively blocked chemical transport through the gelled zone. Our research reveals that a process using silica suspension injection and sequential gelation technology is promising for blocking the vertical water flow and chemical transport through the filter pack in targeted zones within the annulus of long-screened well systems.

54 ENVIRONMENTAL SCIENCES↗

Sensitometric data for earth resources film

Sensitometry is applied to all photographic earth resources mission film processing. The exposure is made using an intensity modulated sensitometer with a 2850 K source filtered to produce a 5500 K spectral distribution. In addition, any filters used on the sensor are included in the sensitometer filter pack in order to accurately simulate the exposure conditions. The modulator consists of a continuous carbon wedge and a 20-step carbon step tablet.

Perry, L.↗

Measurements of the nitric acid to NO(x) ratio in the troposphere

Nitric acid concentrations, measured by both teflon/nylon filter packs (FP) and the tungstic oxide denuder (DEN), are compared with the average NO(x) concentrations from LIF and chemiluminescent methods. The HNO3/NO(x) ratio based on FPs ranged from 0.8 to 10.4, with a mean of 3.4. The DEN nitric acid concentrations produced ratios ranging from less than 0.3 to 9.8, with a mean of 2.6. Average marine ratios were larger than those from continental regions, in part due to continental anthropogenic sources of NO(x).

Huebert, B. J.↗

Annular denuders for use in global climate and stratospheric measurements of acidic gases and particles

Measurements of acidic and basic gases that coexist with fine particle (less than 2.5 micron) may be useful for determining the impact of these species on global climate changes and determining species that influence stratospheric ozone levels. Annular denuders are well suited for this purpose. A new concentric annular denuder system, consisting of a three channel denuder, a Teflon coated cyclone preseparator, and a multistage filter pack was developed, evaluated, and shown to provide reliable atmospheric measurements of SO2, HNO2, HNO3, NH3, SO4(=), NH4(+), NO3(-), and H(+). For example, the precision of the annular denuder for the ambient measurements of HNO3 and nitrates at concentrations between 0.1 to 3 microgram/cu m was + or - 12 and 16 pct., respectively. The 120 x 25 mm three channel denuder is encased in a stainless steel sheath and has annular spaces that are 1 mm wide. This design was shown to have nearly identical capacity for removal of SO2 as conventional 210 x 25 mm single channel denuder configurations. The cyclone preseparator was designed and tested to have a D sub 50 cutoff diameter of 2.5 micron and minimal retention of HNO3.

Stevens, Robert K.↗

Annular denuder systems: Precision and applicability to stratospheric sampling

Annular denuder systems (ADS) are designed to sample both gases and particles from ambient air without cross interference. The ADS's were used to detect chemical gradients over rural forest canopies. Accurate and precise methods for the sampling and analysis of low concentrations of gaseous and particulate species over short sampling periods were developed. Typical analytical precision data for nitrate and sulfate are shown. Both sampling and analytical precision data for a 2 hour test using four collocated ADS's are presented. On this particular day, the overall precision for HNO3 was unusually poor. The overall precision for the major constituents of interest is generally about 3 to 5 percent for typical ambient concentrations. The ADS's could potentially be used to determine the concentrations of HNO3 and fine-particle nitrate in the stratosphere, and to simultaneously characterize the chemical composition of stratospheric aerosols. Assuming 50 mb pressure, a 2 hour sampling time, a 50 Lpm sampling rate, and a low blank value, an overal precision of about 15 percent should be possible for 1 ppbv of HNO3 or nitrate, which would include nitric-acid trihydrate (NAT); and pump-driven systems could accommodate more complex systems involving denuders and filter packs in sequence. Alternate coatings could possibly be developed to selectively sample species such as Cl2 and ClNO3. The ADS's might also be useful in laboratory studies of heterogeneous chemical reactions involving NAT aerosols.

Randtke, Stephen J.↗

An intercomparison of five ammonia measurement techniques

Results obtained from five techniques for measuring gas-phase ammonia at low concentration in the atmosphere are compared. These methods are: (1) a photofragmentation/laser-induced fluorescence (PF/LIF) instrument; (2) a molybdenum oxide annular denuder sampling/chemiluminescence detection technique; (3) a tungsten oxide denuder sampling/chemiluminescence detection system; (4) a citric-acid-coated denuder sampling/ion chromatographic analysis (CAD/IC) method; and (5) an oxalic-acid-coated filter pack sampling/colorimetric analysis method. It was found that two of the techniques, the PF/LIF and the CAD/IC methods, measured approximately 90 percent of the calculated ammonia added in the spiking tests and agreed very well with each other in the ambient measurements.

Williams, E. J.↗

Two-Phase Flow in Filters and Orifices: ISS Packed Bed Reactor Experiment Water Recovery Series (PBRE-WRS)

Understanding the hydrodynamics of adiabatic two-phase flows in packed bed reactors offers numerous benefits. It enables the optimization of chemical reactions rates and products which results in more efficient and compact reactors, thus reducing space and resource requirements, crucial for long duration space missions. The Packed Bed Reactor Experiment-Water Recovery Series (PBRE-WRS) is a flight experiment planned for operation on the Microgravity Science Glove box (MSG) facility of the International Space Station (ISS). The objective of the experiment is to validate hydrodynamic models at a range of gas and liquid flow rates, where these models are used in the design of processes for life support systems in microgravity. The microgravity environment allows for measurement and observation of aspects of fluid dynamics that are unique when compared to observations made in full or partial gravity environments. The experiment consists of testing two-phase flow hydrodynamics in three different filters, four (4) orifices and one check valve test articles. The experiment utilizes the hardware of the previously flown PBRE and PBRE-2 with packed beds of different packings materials and sizes. The fluid system of the PBRE-WRS consists of a nitrogen gas delivery and water delivery subsystems. The gas delivery subsystem can accommodate two ranges of gas flow rates, just as for the water delivery system. The nitrogen gas loop is open whereas the water loop is closed. Gas is separated from the water using a gas-liquid phase separator which is located in the water delivery module. Preliminary results from ground testing show the pressure drop across the filters increasing at different rates with the liquid and gas flow rates. In this work, a detailed system description is presented along with a summary of results from ground performance testing of different test sections in an end-to-end preflight testing campaign.

ISS↗

Detecting Short Circuits: Post Accident Electric Vehicle Battery Safety Check

Fast and accurate detection of soft short circuits (SCs) in the battery packs of damaged electric vehicles is needed by first responders and mechanics to mitigate the potential risk from battery fires that may occur hours, days, or weeks after an accident. Here, this paper presents an SC-detection algorithm for potentially damaged lithium-ion batteries that works quickly and without a priori knowledge of the battery-pack chemistry, capacity, state of charge, or state of health. The proposed universal SC-detection algorithm is designed to be implemented on an inexpensive handheld device that can connect to and monitor the voltages of all cells in a pack. Transient filtering and linear-quadratic state observation provide estimates of normalized SC current for every cell in the pack. Cells with SC-current estimates outside a sigma-based threshold are detected. Simulations, experiments, and electric vehicle (EV) crash data are used to verify the speed, sensitivity, and accuracy of the method, demonstrating 96% accurate detection of 0.0027 C SCs in under 1 h for 5S cell groups in the lab and no false positives for crashed Volkswagen, Chevrolet, and Tesla vehicles without SCs.

25 - ENERGY STORAGE↗

Packing Optimization of an Intentionally Stratified Sorbent Bed Containing Dissimilar Media Types

The Fire Cartridge is a packed bed air filter with two different and separate layers of media designed to provide respiratory protection from combustion products after a fire event on the International Space Station (ISS). The first layer of media is a carbon monoxide catalyst made from gold nanoparticles dispersed on iron oxide. The second layer of media is universal carbon, commonly used in commercial respirator filters. Each layer must be optimally packed to effectively remove contaminants from the air. Optimal packing is achieved by vibratory agitations. However, if post-packing movement of the media within the cartridge occurs, mixing of the bed layers, air voids, and channeling could cause preferential air flow and allow contaminants to pass. Several iterations of prototype fire cartridges were developed to reduce post-packing movement of the media within each layer (settling), and to prevent mixing of the two media types. Both types of movement of the media contribute to decreased fire cartridge performance. Each iteration of the fire cartridge design was tested to demonstrate mechanical loads required to cause detrimental movement within the bed, and resulting level of functionality of the media beds after movement was detected. In order to optimally pack each layer, vertical, horizontal, and orbital agitations were tested and a final packed bulk density was calculated for each method. Packed bulk density must be calculated for each lot of catalyst to accommodate variations in particle size, shape, and density. In addition, a physical divider sheet between each type of media was added within the fire cartridge design to further inhibit intermixing of the bed layers.

Kidd, Jessica↗