Search NASA⌕ Search

SEARCH · Search NASA

Results for “Finite element model calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Thermally anisotropic building envelope for thermal management: finite element model calibration using field evaluation data

The thermally anisotropic building envelope (TABE) is an active building envelope that redistributes thermal loads in response to weather conditions and building energy demand. Conductive layers throughout the TABE distribute low-grade heat among hydronic loops, altering heat flow direction and intensity. Finite element models of TABE roof and wall panels were developed and calibrated using field evaluation data. The calibration results showed that heat flux differences between the experimental data and finite element models averaged –0.42% and 3.57%, with a maximum mean square error of 1.78 and 3.96 for roof and wall panels, respectively. A reduction in heat flux from the environment to the building living space over the entire testing period (weeks in July/August) was found to be 85% for roof panels and 335% (load reversed) for wall panels. Finally, these results indicate TABE can effectively harness low-grade thermal energy sources to achieve high energy efficiency and promote demand-side management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Near-Net-Shape HIP Manufacturing for sCO2 Turbomachinery Cost Reduction

sCO2 turbomachinery that operates above 650°C requires the use of γ' strengthened Ni-based superalloys, leading to high cost and barrier of market adoption. Near-net-shape (NNS) HIP manufacturing with 282® alloy powder is being developed for sCO2 turbine components, with a significant estimated cost reduction. Tensile, creep, low cycle fatigue properties of argon gas atomized and plasma atomized powders were evaluated and compared to sand cast HAYNES® 282®. While tensile strength and fatigue life outperformed sand cast material, a 10~25% debit in the creep stress capability was observed due to the fine grain size and presence of prior particle boundaries (PPBs). Finite element model calibrated by powder rheological properties accurately predicted the nonuniform shrinkage during HIP, providing HIP tooling design to achieve the target dimension. A 20 lbs. turbine nozzle ring was successfully demonstrated within 0.01 inch dimensional tolerance at the vanes. A 1700lbs. turbine casing with complex internal struts and manifolds was also demonstrated being close to the target dimension.

14 SOLAR ENERGY↗

An asynchronous parallel high-throughput model calibration framework for crystal plasticity finite element constitutive models

Crystal plasticity finite element model (CPFEM) is a powerful numerical simulation in the integrated computational materials engineering toolboxes that relates microstructures to homogenized materials properties and establishes the structure–property linkages in computational materials science. However, to establish the predictive capability, one needs to calibrate the underlying constitutive model, verify the solution and validate the model prediction against experimental data. Bayesian optimization (BO) has stood out as a gradient-free efficient global optimization algorithm that is capable of calibrating constitutive models for CPFEM. Here in this paper, we apply a recently developed asynchronous parallel constrained BO algorithm to calibrate phenomenological constitutive models for stainless steel 304 L, Tantalum, and Cantor high-entropy alloy.

304L stainless steel↗

Power Law Hardening Fit for Inconel 718 Material

The objective of this work is to create an accurate elastic-plastic J2 plasticity model calibration for the Inconel 718 material at room temperature for use in finite element models. This calibration was made using a power-law hardening model of form σ = σ y + $Aε^{n}_{p}$ where A and n are empirically determined constants, and σ y is the proportional limit.

36 MATERIALS SCIENCE↗

Bayesian optimization for inverse calibration of expensive computer models: A case study for Johnson-Cook model in machining

Inverse model calibration for identifying the constitutive model parameters can be computationally demanding for expensive-to-evaluate simulation models. Here, this paper presents a modified Bayesian optimization (BO) method, denoted as BO-bound, that incorporates theoretical bounds on the quantity of interest. A case study for the inverse calibration of the Johnson Cook (J-C) flow stress model parameters is presented using machining (cutting) force data. The results show fast calibration of the five J-C parameters within 25 simulations. In general, the BO-bound method is applicable for inverse calibration of any expensive simulation models as well as optimization problems with known bounds.

Bayesian optimization↗

Direct sensitivity analysis on the parameterization of crystal plasticity models

Various methods for calibrating crystal plasticity finite element (CPFE) models lead to non-unique input parameter values, which subsequently introduce uncertainty in the predicted mechanical response. Sensitivity analysis (SA) conducted on crystal plasticity models is used to identify how variability in these parameters contribute to output uncertainty. Traditional SA on CPFE parameters uses simplified surrogate models to save computational time. However, the accuracy of the surrogate models depends on the quantity of training data used, and any modeling error can propagate into the SA results, potentially affecting their reliability. In this work, the elementary effects test (EET) method, a global SA technique using direct CPFE simulations was employed, and the results obtained were compared with the First Order Second Moment (FOSM) method. ExaConstit, an open-source GPU-enabled CPFE code, was used to perform the simulations and direct SA. The EET method was accurately able to capture the non-linear effects of all the input parameters on the output and is a valuable approach for reliably attributing parameter sensitivities in CPFE models. Based on the results, efficient strategies to perform future parameter calibration and SA are discussed. Additionally, the SA trends observed in different single crystal orientations closely mirrored the activity of the slip systems.

Elementary Effects Test↗

WHA Sphere Impacting RHA Plate: Modeling Brittle Behavior in Metal Alloys

Brittle behavior of metal alloys is often critical to modeling ballistic impact and penetration. The ALEGRA multiphysics finite element software incorporates calibrated models for the equation of state, elasticity, yield stress, plasticity and fracture, but simulations do not always capture expected metal fracture. Here we report concerted efforts to do so for one important case where experiments clearly show shear fractures: a tungsten sphere impacting a steel plate at various angles. Our best simulations show fractures that are qualitatively similar to experiments, but there are significant differences in quantitative metrics. Specifically, velocities of tracers used to quantify simulated plug parameters consistently fall short of measured plug velocities. Also, simulated plugs break apart more than expected from experimental evidence. We attribute these shortfalls to the lack of an explicit shear fracture mechanism in the material models, leading to over-estimated resistance to plug formation and movement.

36 MATERIALS SCIENCE↗

Digital image correlation and infrared thermography data for seven unique geometries of 304L stainless steel

Material Testing 2.0 (MT2.0) is a paradigm that advocates for the use of rich, full-field data, such as from digital image correlation and infrared thermography, for material identification. By employing heterogeneous, multi-axial data in conjunction with sophisticated inverse calibration techniques such as finite element model updating and the virtual fields method, MT2.0 aims to reduce the number of specimens needed for material identification and to increase confidence in the calibration results. To support continued development, improvement, and validation of such inverse methods—specifically for rate-dependent, temperature-dependent, and anisotropic metal plasticity models—we provide here a thorough experimental data set for 304L stainless steel sheet metal. The data set includes full-field displacement, strain, and temperature data for seven unique specimen geometries tested at different strain rates and in different material orientations. Commensurate extensometer strain data from tensile dog bones is provided as well for comparison. We believe this complete data set will be a valuable contribution to the experimental and computational mechanics communities, supporting continued advances in material identification methods.

36 MATERIALS SCIENCE↗

Study of Microphonic Effects on the C100 Cryomodule for High Energy Electron Beam Accelerators

The Continuous Electron Beam Accelerator Facility (CEBAF) at Thomas Jefferson National Laboratory (JLab) is a particle accelerator which can accelerate an electron beam to relativistic speeds and apply the beam onto target samples. The C100 superconducting radio frequency (SRF) cavity is the primary accelerating structure of the C100 cryomodule, one of the many cryomodules which compose the CEBAF linear accelerator. SRF cavities are particularly sensitive to internal and external vibrations that can result in a phenomenon called microphonics which degrade the operational stability of a cryomodule. The purpose of this thesis is to investigate the significance of mechanical disturbances on the electromagnetic resonant frequency of a C100 SRF cavity. Knowledge of the mechanical resonance of the cavities and cryomodule sheds light into how these disturbances are most easily realized as deformation which causes radio frequency (RF) detuning. Three studies were conducted: the development and hammer test calibration of a Finite Element Analysis (FEA) model of a C100 cavity, the development and hammer test calibration of an FEA model of a C100 cavity string, and the hammer test of the C100-10R cryomodule at the Cryomodule Test Facility (CMTF). The cavity FEA model was found to accurately predict two modes found in two real cavities in a simply supported configuration. The cavity string FEA model leveraged the calibrated cavity FEA model but was not found to accurately predict the modal behavior of a real cavity string. Even so, the modal behavior of the cavity string inside the C100-10R cryomodule was captured during a hammer test while it was partially assembled. Finally, the C100-10R cryomodule was placed in the CMTF to study RF detuning. The RF detuning spectra during hammer hits and background noise was captured. The results of the hammer testing indicate two strong peaks at low frequencies (9-10 Hz and 22-23 Hz). These two frequencies were found to be nearly coincident to four instances of mechanical resonance found during the hammer testing done on the partially-assembled C100-10R. Because of this, these two modes are believed to contribute to RF detuning of the cryomodule. This test event also included the testing of the effectiveness of a configuration of BNNT canisters designed to act as dampers. While these tests show promising results, the lurking variables render these tests somewhat inconclusive.

Hull, Caleb James↗

High Temperature Sodium Submersible Flowmeter Design and Analysis

This work details the design and analysis of a permanent magnet flowmeter designed to be submerged in a pool type sodium fast reactor environment. Recently developed Samarium Cobalt rare earth magnets were utilized that have demonstrated resilience to temperature and neutron flux up to 550 °C and 10 18 n/cm 2 , respectively. This paper will discuss the theory, design, calibration and uncertainty quantification of the flowmeter. The flowmeter was calibrated over a flowrate range of 11.4 - 90.9 LPM at temperatures of 220 and 400 °C, yielding an uncertainty in calibration of 2-3.6%. Here, a finite element model was developed and validated experimentally, yielding <; 3.2% error.

47 OTHER INSTRUMENTATION↗

Plasticity and fracture behavior of Inconel 625 manufactured by laser powder bed fusion: Comparison between as-built and stress relieved conditions

In this work, the influence of stress relief on the plasticity and fracture behavior of Inconel 625 fabricated through laser powder bed fusion additive manufacturing (AM) was investigated. The as-built versus stress relieved microstructures were compared, showing similar grain structures but the presence of ~10 vol % δ phase in the stress relieved condition, and no δ phase in the as-built condition. Mechanical tests under plane strain tension were performed on the stress relieved samples, and an anisotropic plasticity model was calibrated and validated using finite element simulations. Uniaxial and notched tension tests were performed on both as-built and stress relieved samples to probe the effect of stress relief on stress state- and direction-dependent fracture behavior. It was found that on average, the fracture strain of the stress relieved samples along the build direction was 30% higher than that along the perpendicular build direction in the stress state range studied, and the stress relief heat treatment resulted in a 45% decrease in fracture strain. The fracture strain in stress relieved samples was more strongly dependent on stress state than in as-built samples.

36 MATERIALS SCIENCE↗