An Advanced Simulation based 3D Framework and Toolkit for Fire Protection and Fire Probabilistic Risk Analysis
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The Fire Protection Office (FP) serves LANL, DOE/NNSA, and the surrounding community by providing fire protection engineering and program services to minimize fire-related risks.
Fire-resistant and nonsmoking foam can be prepared in desirable density range of 24 to 50 kg/cu m by controlled thermal crosslinking of polybenzimidazole prepolymer. Reproducible foams of specific density can be produced by controlling volative content and melting temperature of prepolymer.
Fire protection of critical space assets, including launch and fueling facilities and manned flight hardware, demands automatic sensors for continuous monitoring, and in certain high-threat areas, fast-reacting automatic suppression systems. Perhaps the most essential characteristic for these fire detection and suppression systems is high reliability; in other words, fire detectors should alarm only on actual fires and not be falsely activated by extraneous sources. Existing types of fire detectors have been greatly improved in the past decade; however, fundamental limitations of their method of operation leaves open a significant possibility of false alarms and restricts their usefulness. At the Civil Engineering Laboratory at Tyndall Air Force Base in Florida, a new type of fire detector is under development which 'sees' a fire visually, like a human being, and makes a reliable decision based on known visual characteristics of flames. Hardware prototypes of the Machine Vision (MV) Fire Detection System have undergone live fire tests and demonstrated extremely high accuracy in discriminating actual fires from false alarm sources. In fact, this technology promises to virtually eliminate false activations. This detector could be used to monitor fueling facilities, launch towers, clean rooms, and other high-value and high-risk areas. Applications can extend to space station and in-flight shuttle operations as well; fiber optics and remote camera heads enable the system to see around obstructed areas and crew compartments. The capability of the technology to distinguish fires means that fire detection can be provided even during maintenance operations, such as welding.
A crash-fire protection system is described which will suppress the ignition of crash-spilled fuel that may be ingested by a T-56 turbo-propeller engine. This system includes means for rapidly extinguishing the combustor flame, means for cooling and inerting with water the hot engine parts likely to ignite engine ingested fuel, and means for blanketing with bromotrifluoromethane massive metal parts that may reheat after the engine stops rotating. Combustion-chamber flames were rapidly extinguished at the engine fuel nozzles by a fuel shutoff and drain valve. Hot engine parts were inerted and cooled by 42 pounds of water discharged at seven engine stations. Massive metal parts that could reheat were inerted with 10 pounds of bromotrifluoromethane discharged at two engine stations. Performance trials of the crash-fire protection system were conducted by bringing the engine up to takeoff temperature, actuating the crash-fire protection system, and then spraying fuel into the engine to simulate crash-ingested fuel. No fires occurred during these trials, although fuel was sprayed into the engine from 0.3 second to 15 minutes after actuating the crash-fire protection system.
This report documents analysis to determine whether a hydrogen jet flame impinging on a tunnel ceiling structure could result in permanent damage to the Callahan tunnel in Boston, Massachusetts. This tunnel ceiling structure consists of a passive fire protective board supported by stainless steel hangers anchored to the tunnel ceiling with epoxy. Three types of fire protective boards were considered to determine whether heat from the flame could reach the stainless-steel hangers and the epoxy and cause the ceiling structure to collapse. Heat transfer analyses performed showed that the temperature remains constant where the steel hangers are attached to the passive fire protective board. According to these results, the passive fire protective board should provide adequate protection to the tunnel structure in this release scenario. Tunnel structures with similar suspended fire-resistant liner board materials should protect the integrity of the structure against the extremely low probability of an impinging hydrogen jet flame.
The current multi-year effort seeks to utilize national laboratory support from Argonne to expedite revival of the ANS-54.8 standard titled “Liquid Metal Fire Protection in LMR Plants.” To achieve that objective, the following tasks were identified: Task 1 involves working directly with ANS to revive the ANS-54.8 Working Group. This was to be accomplished by completing necessary paperwork, submitting that paperwork to ANS for approval, enlisting potential working group members from industry, the NRC, national laboratories, and universities, and organizing and leading Working Group activities. The overall purpose of the Working Group is to develop an updated draft of ANS-54.8 for review and approval by ANS consensus committees, the ANS Standards Board, and certification from ANSI. Task 2 focuses on leveraging historical information and expertise at Argonne related to sodium fire protection systems and strategies. For more than a decade, Argonne has worked on both international and domestic projects related to sodium fire protection system development and evaluation. The goal of this task is to utilize that experience to help inform the ANS-54.8 Working Group on important considerations that may be addressed in an updated draft of ANS-54.8. Task 3 focuses on leveraging Argonne experience in the development of and use of analysis methods and tools for the simulation of sodium fire scenarios and evaluation of the effectiveness of sodium fire protection systems and strategies. For more than a decade, Argonne has recovered, modified, and utilized several historical sodium fire analysis software tools. The goal of this task is to utilize that experience to help inform the ANS-54.8 Working Group of best practices for sodium fire progression analysis that may be addressed in an updated draft of ANS-54.8.
As part of preparing for the Crew Exploration Vehicle (CEV), the National Aeronautics and Space Administration (NASA) worked on developing the requirements to manage the fire risk. The new CEV poses unique challenges to current fire protection systems. The size and configuration of the vehicle resembles the Apollo capsule instead of the current Space Shuttle or the International Space Station. The smaller free air volume and fully cold plated avionic bays of the CEV requires a different approach in fire protection than the ones currently utilized. The fire protection approach discussed in this paper incorporates historical lessons learned and fire detection and suppression system design philosophy spanning from Apollo to the International Space Station. Working with NASA fire and materials experts, this approach outlines the best requirements for both the closed out area of the vehicle, such as the avionics bay, and the crew cabin area to address the unique challenges due to the size and configuration of the CEV.
Fire prevention, protection, and fighting systems at KSC for space shuttle operations
Fire prevention activities at NASA's Stennis Space Center are reviewed in this viewgraph presentation. The Fire Prevention Office of the Fire Department at NASA Stennis conducts inspections and issues small appliance permits, while the Operations Section responds to emergencies.
This viewgraph presentation provides information on fire protection operations and administration at Stennis Space Center (SSC). The presentation also lists innovative practices and recent improvements.
An overview of lithium-ion battery safety as it pertains to fire protection engineers for the 6th edition of the Society of Fire Protection Engineering Handbook
A crash-fire protection system to suppress the ignition of crash-spilled fuel that may be ingested by a T-56 turbopropeller engine is described. This system includes means for rapidly extinguishing the combustor flame and means for cooling and inerting with water the hot engine parts likely to ignite engine-ingested fuel. Combustion-chamber flames were extinguished in 0.07 second at the engine fuel manifold. Hot engine parts were inerted and cooled by 52 pounds of water discharged at ten engine stations. Performance trials of the crash-fire prevention system were conducted by bringing the engine up to takeoff temperature, stopping the normal fuel flow to the engine, starting the water discharge, and then spraying fuel into the engine to simulate crash-ingested fuel. No fires occurred during these trials, although fuel was sprayed into the engine from 0.3 second to 15 minutes after actuating the crash-fire protection system.
A high-performance sandwich-type fire protection system comprising a steel outer sheath and insulation combined in various configurations is described. An inherent advantage of the sheath system over coatings is that it eliminates problems of weatherability, materials strength, adhesion, and chemical attack. An experimental comparison between the protection performance of state-of-the-art coatings and the sheath system is presented, with emphasis on the protection of certain types of steel tanks for fuel storage and transport. Sheath systems are thought to be more expensive than coatings in initial implementation, although they are less expensive per year for sufficiently long applications.
This fire protection engineering technical report discusses and presents the properties, data, and safety of select lithium-ion batteries. Lithium-ion batteries have increased in usage and a fire scenario analysis must be created for each situation where they may be introduced in buildings to determine the risk associated if a battery failure were to occur.
NASA's JPL has completed a feasibility study using infrared technologies for wildland fire suppression and management. The study surveyed user needs, examined available technologies, matched the user needs with technologies, and defined an integrated infrared wildland fire mapping concept system configuration. System component trade-offs were presented for evaluation in the concept system configuration. The economic benefits of using infrared technologies in fire suppression and management were examined. Follow-on concept system configuration development and implementation were proposed.
NERAC, Inc., Tolland, CT, aided Paul Monroe Engineering, Orange, CA, in the development of their PC1200 Series Fire Protection Jacket that protects the oil conduit system on an offshore drilling platform from the intense hydrocarbon fires that cause buckling and could cause structural failure of the platform. The flame-proof jacketing, which can withstand temperatures of 2000 degrees Fahrenheit for four hours or more, was developed from a combination of ceramic cloth (similar to the ceramic in Space Shuttle tiles), and laminates used in space suits.
Avco has drawn upon its heat shield experience to develop a number of widely-accepted commercial fire protection materials. Originating from NASA's space shuttle thermal protection system, one such material is Chartek 59 fireproofing, an intumescent epoxy coating specifically designed for outdoor use by industrial facilities dealing with highly flammable products such as oil refineries and chemical plants. The coating is applied usually by spray gun to exterior structural steel conduits, pipes and valves, offshore platforms and liquefied petroleum gas tanks. Fireproofing provides two types of protection: ablation or dissipation of heat by burn-off and "intumescence" or swelling; the coating swells to about five times its original size, forming a protective blanket of char which retards transfer of heat to the metal structure preventing loss of structural strength and possible collapse which would compound the fire fighting problem.