Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fire Stations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Energy Improvements of Fire Station 71

Since 2018, the City of Shawnee, Kansas has completed two phases of the State of Kansas Facility Conservation Improvement Program (FCIP), an initiative that guarantees operational cost and energy savings through targeted construction improvements on City facilities and infrastructure. The City is currently in the third phase of this FCIP, where one of the projects included an investment in energy improvements for Fire Station 71 (FS 71). The City partnered with Navitas, an Energy Service Company (ESCO), to implement a Photovoltaic Solar Array on FS71. The purpose of this project was to invest in sustainable building improvements with Energy Conservation Measures (ECM) to bring cost savings to the City and to provide sustainable benefits to the residents of Shawnee. In the first task of the project, Navitas collaborated with the City of Shawnee and the Community Development Department to determine the optimal layout and schedule for the installation of the solar array on FS 71. In the second task of the project, Navitas installed the 99.8 kW DC Photovoltaic solar array system. This system installation comprised of racking, inverters, optimizers, load center, and disconnect, which were all installed at a total ECM price of $\$$247,948. The third task focused on start-up and commissioning of the array. Navitas installed a real-time data analytics information management system integrated with utility meters, which evaluates the operations of the utility system and verifies operation of equipment and ensures optimum operation for energy efficiency. In the final task of this project, this analytics system was used for monitoring and verification, which will continue to be used to evaluate the success of the project for the coming years. The primary goal of the project was to install the 99.8 kW DC PV solar array at FS 71 to demonstrate the viability of solar energy systems in essential municipal facilities. Fire stations are energy demanding structures, as they require a constant intake of power and have a high baseline energy usage. The success of solar arrays on a fire station exemplifies their energy efficiency and effectiveness and displays their potential for application on other city facilities. By installing a solar array at such a facility, the City sought not only to offset electricity usage but also to serve as a model for ECMs in other municipal facilities and infrastructure projects. From an economic standpoint, this project demonstrates the feasibility of renewable energy at the municipal level. The total project cost of $\$$247,948 was split evenly between city funds and award funding, minimizing financial risk while ensuring guaranteed long-term savings. Any excess savings that are beyond the guaranteed minimums remain with the city, which enables future investment in sustainable energy initiatives. This project provides many benefits to the public. In addition to reducing the environmental footprint of city operations, it lowers taxpayer-funded utility spending and improves the energy security of a critical facility. The knowledge gained from this implementation motivates the City to focus on similar efforts across other public facilities in future FCIP phases and other City projects.

14 SOLAR ENERGY↗

Mitigation for the demolition of building 25-3153, fire station, area 25, Nevada national security site, NYE county, Nevada

The purpose of this letter report is to document the mitigation of adverse effects of a proposed undertaking that would demolish Building 25-3153 in Area 25 of the Nevada National Security Site (NNSS) in compliance with the terms of the 2024 Programmatic Agreement among the U.S. Department of Energy and the Nevada State Historic Preservation Officer and the Advisory Council on Historic Preservation Concerning the Protection of Historic Properties on the Nevada National Security Site, Nye County, Nevada (NNSS PA). Building 25-3153 (State Historic Preservation Office [SHPO] Resource # B19004) is a contributing element to the Nuclear Rocket Development Station (NRDS) Historic District (SHPO Resource # D424), which has been determined eligible for listing in the National Register of Historic Places (NRHP) under Criteria A, B, C, and D (Reno et al. 2023). The proposed demolition constitutes an adverse effect. The U.S. Department of Energy (DOE) National Nuclear Security Administration Nevada Field Office (NNSA/NFO) consulted with the SHPO on an adverse effect finding for the undertaking and notified the SHPO of its intent to use the standard mitigation in the NNSS PA on December 11, 2024 (Julian to Reed). The SHPO concurred on December 30, 2024 (Reed to Julian). Therefore, NNSA/NFO has prepared mitigation pursuant to the standard mitigation in the NNSS PA Appendix D.I.A for contributing elements to recorded, NRHP-eligible districts.

#B19004↗

Exploring Wildfire & Energy data toward State Prioritization Index (WESPI)

Energy infrastructure can both induce and suffer risks from wildfires ranging from direct damage to energy assets such as substations and power lines to Public Safety Power Shutoffs. Recent wildfire events underscore the need for data-driven approaches that help states and utilities proactively plan for wildfire risk. Existing national tools such as Federal Emergency Management Agency (FEMA)’s National Risk Index (NRI) are valuable for community hazard planning. However, they are less suited for energy infrastructure, as they emphasize population and building exposure rather than system vulnerabilities. In this paper, we explore relationships between energy and wildfire data and present a Wildfire-Energy State Prioritization Index (WESPI). Our methodology combines data from the US Forest Service’s Fire Simulation (FSIM) dataset with energy resilience metrics, historical fire incidents, and geospatial data on transmission lines and fire stations. Correlation analyses suggest that FSIM burn probability is more strongly associated with power outage metrics (ρ = 0.32) than NRI wildfire frequency, and counties with a greater density of fire stations experience more frequent, but less intense wildfires. We further leverage data for burn probability, transmission line density, and fire station density to develop a Wildfire-Energy State Prioritization Index (WESPI) to highlight counties where wildfire hazard, infrastructure exposure, and limited suppression capacity converge. The index provides a consistent, scalable framework for state energy offices and utilities to screen counties for vegetation management, optimization of outage management system deployment, and to inform wildfire mitigation plans.

Critical infrastructure↗

Data and code from: Multivariate bayesian regression model for predicting disposed ash composition at U.S. coal fired power stations

This dataset contains the code and data files needed for implementation of a Multivariate Bayesian Regression model, described in Jin et al. (2025), for the historical prediction of the chemical composition of disposed coal ash at U.S. coal fired power plants as a function of annualized coal purchase data. The integrated coal supply data file (CoalSupplyDataset.csv) represents a compilation of monthly fuel purchase records for the period 1973-2022 at major U.S. power stations. These records were obtained from the U.S. Energy Information Administration. The CSV file also contains, for each coal purchase record, the coal region of the mine as defined by the U.S. Geological Survey. Data entry errors and data gaps in the EIA records were corrected as described in Jin et al. This CSV file represents the integrated coal supply data after corrections were made. The model structure and fitting parameters are encoded in pickle file format (Bayesian.pkl). The model was developed with the coal supply data and coal ash composition data, apportioned according to the Stratified Shuffle Split for training and testing subsets. The model was built using Python and the PyMC library. Reference Publication: Jin, Z.; Huang, J.; Hower, J.C.; Hsu-Kim, H.(2025). Predictive Assessment of the Chemical Composition of Coal Ash in Reserve at U.S. Disposal Sites. Environmental Science & Technology.

Coal ash composition↗

PFAS Removal by Ion Exchange Resins: Background and Knowledge Gaps with Respect to the Hanford Site

Per- and polyfluoroalkyl substances (PFAS) have been a rising concern for the past two decades, with the United States Department of Defense and Environmental Protection Agency investing millions of dollars in research into remediation and clean-up technologies. Due to the environmental persistence, toxicity, biological uptake, and ongoing changes in both federal and state regulatory space, understanding the fate and transport of PFAS compounds has been of growing concern to the US Department of Energy (DOE). The DOE’s Hanford Site is investigating historical use of PFAS and will be doing site characterization for PFAS. Thus, PFAS have not yet been identified as a contaminant concern in regulatory documents. Based on historical records that mention the discharge of aqueous film-forming foam containing PFAS and having on-site fire stations (a risk factor for PFAS contamination), it seems likely that environmental releases of PFAS may have occurred. Pump and treat (P&T) remediation is the selected remedy for multiple groundwater contaminant plumes at Hanford. These P&T systems use ion exchange (IX) as a component of aboveground treatment, with the specific resins depending on the target contaminants. There is potential that these IX resins may be able to remove PFAS from groundwater, but investigation is needed to understand affinity/selectivity and removal capacity given the groundwater composition and the operating conditions. This report provides background on PFAS uses and chemistry, then provides a review of IX resin applications for PFAS, identifying knowledge gaps. Recommendations are provided regarding research needed to address knowledge gaps and acquire information needed to propose IX as a future PFAS remediation technology at the Hanford Site, as well as other U.S. Department of Energy sites. Generally, PFAS compounds are fluorinated substances that contain at least one fully fluorinated methyl or methylene carbon – with a few noted exceptions, any chemical with at least a perfluorinated methyl group (–CF3) or a perfluorinated methylene group (–CF2–) is a PFAS. These chemical compounds are characterized as non-biodegradable, non-reactive, non-photolytic, and hydrolysis resistant. This makes them highly recalcitrant within the environment, however polyfluoroalkyl materials are less recalcitrant as the carbon chains contain C–H bonds which are more easily broken than carbon – fluorine (C–F) bonds. The backbone carbon structures are commonly punctuated with a head group, the most well-known of them are perfluorooctanesulfonic acid and perfluorooctanoic acid, which possess a sulfonate and a carboxylate group, respectively. IX resins are marketed for the removal of PFAS from water systems and industrial water, however, the mechanism of removal is not as well understood as for anion or cation removal. A better understanding of the mechanism of removal would enable the development of IX resins that have improved specificity for PFAS removal. Four knowledge gaps were identified: 1) the effect of dissolved ions on the IX resin PFAS removal effectiveness, 2) the effect of additional primary contaminants of concern (PCOCs) or secondary contaminants of concern (SCOCs) on the effectiveness of PFAS via IX resin, 3) the mechanisms of PFAS removal from water, and 4) practical solutions to IX resin regeneration and waste disposal.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AmeriFlux FLUXNET-1F CL-SDP Senda Darwin Peatland

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site CL-SDP Senda Darwin Peatland. This is the FLUXNET version of the carbon flux data for the site CL-SDP Senda Darwin Peatland produced by applying the standard ONEFlux (1F) software. Site Description - Located at the Senda Darwin Biological Station, in a old-growth rainforest. Locally named "pomponal" from the common name of Sphagnum, is an anthropogenic peatland, formed after the forest is cut or a forest fire. The station is 15 km east of Ancud, in the Chiloé Island, close to the Huicha river.

Perez-Quezada, Jorge [University of Chile]↗

Test and Validate Distributed Coaxial Cable Sensors for in situ Condition Monitoring of Coal-Fired Boiler Tubes

This project aims to test, validate, and advance the technology readiness level (from TRL5 to TRL7) of a novel low-cost distributed stainless-steel/ceramic coaxial cable sensing (SSC-CCS) technology for in situ monitoring of the boiler tube temperature in existing coal-fired power plants. The novel SSC-CCS sensing technology and associated condition-based monitoring (CBM) software to be demonstrated in this project will lead to an improved understanding of the boiler tube failure mechanisms and a prognostic system to improve the overall performance, reliability, and flexibility of the nation’s coal-fired power plant fleet. A boiler tube monitoring system with distributed coaxial cable temperature sensors and a sensor acquisition system was constructed. The high-temperature coaxial cable sensor with a length of 1.3m was made by using a quartz tube (1mm inner diameter (ID) and 6mm outer diameter (OD)) to concentrically separate a 304 stainless-steel (SS) rod (1mm OD) and SS tube (7.94mm OD and 6.16mm ID). The sensor acquisition system includes a vector network analyzer (VNA), a radio frequency (RF) power amplifier, multiple switches and a USB hub. The distributed stainless-steel quartz coaxial cable sensor (SSQ-CCS) had a linear response to temperature with a resolution uncertainty of σ = 0.77℃. To withstand the harsh conditions of 3,300 steam pressures and 800℃ high temperatures, the sensor was shielded by a protective tube made of the same material as the boiler tube. The protection tube had an OD of 1.5 inches and a thickness of 0.25 inches. In the laboratory tests, the sensor showed good sensitivity and fast response. The drift was bounded between +0.33% and -0.67% during a test at 600℃ for 350 hours, indicating good stability of the sensor. A field test was conducted where four sensors were welded on four superheat tubes (SH-Ts) at a coal-fired power station over 400 days. Conventional thermocouples were welded to the superheater tubes alongside the coaxial cable sensors for the purpose of comparison. Two sensors were capable of distributed sensing, with three multiplexed sensing sections. The other two sensors were single section. During the 400-day test period, the power plant experienced startups and shutdowns. At the steady state operations, the temperature of the boiler tube is about 600℃ (1112°F). The sensors recorded the entire coal-firing processes (start-up, steady state, and shut-down) and the glitch event. A GSM modem and a Watchdog were added to the system to ensure reliable data recording. The GSM modem sent daily messages to plant managers and Clemson team to inform the status of the sensor system. If the system was not normally working, the Watchdog would reboot the system automatically. The new coaxial cable based distributed sensing technology has been proven to be successful in both laboratory and field tests. A comprehensive four-stage multi-physics computational framework has been developed to assist the design, optimization, installation, and operation of SSQ-CCS. With the consideration of various operation conditions, we predict the distributions of flue gas temperatures within coal-fired boilers, the temperature correlation between the boiler tube and SSQ-CCS, and the safety of SSQ-CCS. A conditional-based monitoring system is implemented as well. The computational framework developed in this work can guide the future operation of coal-fired plants and other power plants for the safety prediction of boiler operations.

01 COAL, LIGNITE, AND PEAT↗

Northern Region Coal Prospects

This presentation was delivered to the audience attending the U.S. DOE/USEA Northern Regional Coal Workshop in Bismarck, ND on March 11, 2026. The presentation highlights the opportunity for coal plants in the region to provide power to military installations and data centers. There is also an analysis on how coal-fired power stations maintain regional supply during extreme cold weather events. Finally, a summary slide is presented that highlights a recent business case analysis on diverting captured carbon dioxide for use in enhanced oil recovery in the Bakken.

Bakken↗

Expanding Solar Research and Generation for a Bright Energy Future (Final Technical Report)

This project supported the construction of an outdoor solar research facility for the primary purpose of characterizing panel and system lifetimes in the northern New England climate which features cold winters and warm, humid summers. The facility is designed to be integrated into future efforts to explore the impacts of the New England climate on energy storage and grid integration, as well as methods to mitigate factors like snow and dust coverage in the industrial and agricultural environment of the Intervale farming community and the McNeil wood-fired power generating station. It will provide year-round renewable energy research opportunities for faculty and students. As renewable energy generation and storage have become research priorities for UVM, for the state of Vermont, and for the United States as a whole, this facility will benefit the public on a broad range of scales.

14 SOLAR ENERGY↗

Soil Temperature and Moisture within the Kougarok Fire Complex, Kougarok Road Mile Marker 86, Seward Peninsula, Alaska, 2019-2023

Daily averages of soil temperature and moisture measured once every hour at different heights located at Intensive Monitoring Stations within the Kougarok Fire Complex, Kougarok Road Mile Marker 86 site. Data were retrieved annually from 2019-2023. Package contains 21 *.CSV data files plus a file level metadata *.CSV, data dictionary *.CSV, data file inventory *.CSV, and sensor location site map *.JPG. Data files have header rows, NaN fields indicate invalid or missing data, and negative vertical offsets are above ground.The Kougarok tundra fire complex (KFC) is located north of Nome and the Kigluaik Mountains, near Quartz Creek and the Kougarok River. The site is accessed by foot from the end of the Nome-Taylor Highway (mile marker 86; also called the Kougarok or Beam Road). The KFC burned in six major fires in the decades since 1950 (Alaska Interagency Coordination Center, unpublished data). Lightning ignited five of these fires (1971, 1997, 2015, and 2019) and one was human caused (2002). The mosaic of overlapping fire scars allows for the study of repeat fires in the tundra which, until recently, was not a common phenomenon outside the boreal forest in Alaska. Our reference unburned tundra fire site is south of the KFC located at mile marker 80 of the Nome-Taylor Highway.The two most recent fires are the Mingvk Lake (2015; 21,698 acres burned from 7/27/2015 to 9/28/2015) and Garfield Creek (2019; 422 acres burned from 7/31/2019 to 8/20/19). The Mingvk Lake fire scar includes areas that burned 1-4x (1971, 1997, 2002), while the entirety of the Garfield Creek fire scar has burned 2x previously (1971, 2002).Previous research at the KFC focused on permafrost (Liljedahl et al. 2007; Narita et al. 2015; Iwahana et al. 2016; Tsuyuzaki, Iwahana, and Saito 2017) and vegetation (Narita et al. 2015; Hollingsworth et al. 2021) response to fire. The central Seward Peninsula is characterized by continuous permafrost with a thickness of 15 to 30 m and a mean active layer thickness of 56 cm (Hinzman et al. 2003). Sloping hills with mixed shrub–tussock tundra and tussock tundra vegetation in the uplands are characteristic of the region. Three micrometeorological towers near the Kougarok field site recorded a mean annual temperature of −2.4°C, mean January temperature of −23.1°C, mean July temperature of +11°C, and mean summer rainfall (June–August) of 94 mm from 2000 to 2006 (Liljedahl et al. 2007).The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Characterization of Arsenic and Selenium in Coal Fly Ash to Improve Evaluations for Disposal and Reuse Potential (Final Technical Report)

Coal fly ash is a high volume waste material that is discarded in landfills and surface water impoundments across the U.S. and is also widely recycled for a variety of applications. The leaching of potential of contaminants of concern, such as arsenic (As) and selenium (Se), is often the driver of risk assessments for coal ash disposal and reuse. The extent of leachable As and Se depends on several factors related to environmental conditions and fly ash characteristics. Previous studies employed various methods to delineate the concentration, chemical form, and distribution of As and Se in fly ash materials. However, few studies have attempted to directly correlate these properties to mobilization parameters relevant to disposal and reuse. Instead, the coal residuals industries often rely upon standardized leaching protocols that can be laborious or involve hazardous chemicals. The goals of the project were to: 1) Develop and evaluate a characterization protocol that can be used to screen fly ash samples for leachability of As and Se; 2) Characterize As, Se, and associated constituents of fly ash particles at multiple length scales (nanometer to micrometer) to determine if elemental associations differ as a function of the resolution of characterization; and 3) Establish a predictive model for the chemical composition of coal ash produced annually at major U.S. coal fired power facilities on 50-year national coal supply records. For the first objective, we performed leaching experiments with 52 fly ash samples collected from 15 different U.S. power plants and representing coal feedstocks from the three major domestic coal regions. For this work, we assessed the mobilization potential of As and Se in fly ash based on standardized leaching protocols and performed multivariate and lasso regression analyses to explore correlations of leachable As and Se contents with characteristics such as major element contents, loss on ignition (LOI) and pH. The results of regression models indicated that major elements (Fe, Ca, Al) for a wide range of fly ashes can serve as predictor variables for the leaching potential of As, but not for Se. LOI and pH were not important predictive variables in the models. Both regression approaches resulted in relatively strong fits for leachable As (correlation coefficient R 2 = 0.78 for both models) compared to models for leachable Se (R 2 = 0.49). Overall, these results suggest that correlation models combined with on-site elemental analysis with portable analyzers may enable a screening method for leachable As in coal ash. For the second objective, we utilized nanoscale 2-D imaging (30-50 nm spot size) with the Hard X-ray Nanoprobe (HXN) in combination with microprobe X-ray capabilities (~5 µm resolution) to determine As and Se elemental associations in fly ash particles. Speciation of As and Se was also measured at the nano- to microscale with X-ray absorption spectroscopy. The enhanced resolution of HXN showed As and Se that were diffusely located around or comingled with Ca- and Fe-rich particles. The results also showed nanoparticles of Se attached to the surface of fly ash grains. Overall, a comparison of As and Se species across scales highlights the heterogeneity and complexity of chemical associations for these trace elements of concern in coal fly ash. For the final objective, we developed a predictive model for major element composition of coal ash in reserve at disposal sites of major U.S. coal fired power plants. This model was constructed from coal purchase records of 705 power stations from 1973-2022 and was trained on coal ash composition data showing that coal ash elemental composition is strongly associated with the source of feedstock coal. The model showed regional shifts in the major element contents of ash produced by power plants in the last 50 years, particularly for calcium and iron (expressed as %CaO and %Fe 2 O 3 ), as coal-fired power stations changed their source of coal over this time frame. Our approach enables an estimation of coal ash chemical composition that is stored in waste impoundments at individual power stations. Such information can help delineate the regional market potential for material applications that would utilize coal ash harvested from disposal sites across the U.S.

01 COAL, LIGNITE, AND PEAT↗

Impact of grassland fire dynamics on particulate emission factors

Understanding particulate emission factors in grassland fires is critical for improving air quality assessments and refining emissions inventories. This study explores the dynamic and heterogeneous nature of fire processes and their influence on particulate emissions. Traditional emission factor inventories often rely on static values, overlooking the spatially and temporally variable dynamics of fire behavior. Through field experiments conducted at Konza Prairie Biological Station measuring emissions with uncrewed aerial vehicles, and computational modeling using HIGRAD/FIRETEC, this research highlights the dependency of emission production on localized fire dynamics, including ignition patterns, fuel properties, and atmospheric conditions. The results demonstrate a need for fire dynamic considerations to accurately capture emissions variability.

09 BIOMASS FUELS↗

National Fire Protection Association Spurs the Safe Adoption of EVs Through Education and Outreach

As electric vehicles (EV) and their charging infrastructure steadily increase in popularity across the U.S., growing pains still exist, impeding their true potential for growth. The barriers include a general lack of knowledge around EV systems, range anxiety, electrical workplace safety practices, code compliance and inspection for charging stations, maintenance garages and workers, insurance concerns, and the potential risks associated with damaged lithium-ion batteries (fires, re-ignition, water immersion, and stranded energy).NFPA partnered with SMEs, training development organizations, and Clean City Coalitions to create a series of common online trainings for each EV ecosystem sector, educating communities on the realities of EV proliferation, myths, facts, statistics, codes, and basic information for each sector to become versed in EV knowledge. We also constructed a workshop program for the many EV stakeholders who should be involved in setting up a strategic, cohesive outlook for the participating towns and cities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Predictive Assessment of the Chemical Composition of Coal Ash in Reserve at U.S. Disposal Sites

In the United States, more than 2 Gt of coal combustion residuals (i.e., coal ash) are stored in hundreds of disposal units. Recent federal regulations mandate the closure or retrofitting of most coal ash impoundments, presenting significant challenges for waste management. These regulatory pressures also present opportunities to reuse coal ash. However, the quality and quantity of discarded coal ash across the U.S. are not well known, even though this information is crucial for spurring its reuse for conventional and new material applications. This study describes a predictive model for the major element composition of coal ash in reserve at disposal sites of major U.S. coal-fired power plants. This model was constructed from coal purchase records of 705 power stations from 1973 to 2022 and was trained on coal ash composition data, showing that coal ash elemental composition is strongly associated with the source of feedstock coal. The model showed regional shifts in the major element contents of ash produced by power plants in the last 50 years, particularly for calcium and iron (expressed as %CaO and %Fe2O3), as power stations changed their source of coal over this time frame. Our approach enables an estimation of chemical composition for ash stored in waste impoundments at individual power stations. Such information can help to delineate the regional market resource potential of supplementary cements for concrete and other material innovations that would utilize coal ash harvested from disposal sites across the U.S.

01 COAL, LIGNITE, AND PEAT↗

Carbon Capture Pilot at Dry Fork Power Station (Final Technical Report)

The objective of this project was to design, seek necessary approvals, build and operate a large-scale pilot sorbent-based post combustion carbon capture system (CCS) at a coal fired power generation facility. TDA’s CCS uses a highly stable, low-cost, high-capacity physical adsorbent to effectively remove CO 2 via a combination vacuum and concentration swing adsorption (VCSA) process. The CCS is integrated with the power plant flue gas exhaust, which is rich in CO 2 (~13% vol. CO 2 ) and removes more than 90% of the plant’s overall carbon emissions.

01 COAL, LIGNITE, AND PEAT↗

The composition of gases from a diffusion flame above longleaf pine needle fuel beds

The gas and tar composition of a diffusion flame from longleaf pine needles is currently poorly understood and more data are needed to fill in the gap between pyrolysis data and smoke plume data, thus improving physical and chemical modeling of wildland smoke formation. A pilot experiment to measure light gas and tar composition of such a flame is described for three flame regions: persistent flame (flame base), intermittent flame, and smoke plume. Flame gases from 24 experimental fires were collected in canisters and analyzed using EPA method TO-14A for CO 2 , CO, H 2 , CH 4 , and C 2 to C 7 hydrocarbon gases. Condensed gas (tar) samples were collected and analyzed using GC/MS. Other light gases were measured using FTIR spectroscopy. Results from compositional data analysis suggest significant differences in (relative) concentration of compounds detected in the three regions of the flame. Statistical tests for differences in flame zones were performed using the canister data: Concentration of hydrocarbons relative to CO and CO 2 decreased from the persistent flame zone above the pyrolyzing needles through the intermittent flame region into the flame-free plume. This was likely due to both chemical reactions (oxidation) occurring in the flame as well as the introduction of air into the flame/plume by entrainment.

Biomass↗

Electrically‐Driven Metal‐Insulator Transitions Emerging from Localizing Current Density and Temperature

Negative differential resistance (NDR) is a key electronic response enabling two‐terminal artificial neurons that can be achieved through different physical phenomena, including phase‐homogeneous current density and temperature (electro‐thermal) localizations and spatially‐localized metal‐insulator phase transitions (MITs). These two effects have been observed to occur sequentially in select electrically‐biased transition metal oxides. However, it is unknown why and under what conditions localizing behaviors precede MITs, particularly as a function of device length scale. To this end, the interplay between phase‐homogeneous electro‐thermal localizations and MITs is investigated in a 3D multiphysics simulation of a lateral thin film device, using the material properties of the prototype MIT material VO 2 . These findings demonstrate that the MIT is nucleated through dynamically localizing current density and temperature. A critical device width (≈0.7 µm in this study) is identified, below which both the electrically‐induced electro‐thermal and phase inhomogeneities cease to appear. It is demonstrated that the formation of spatial inhomogeneities directly relates to device dimensions, and demonstrate the decoupling of NDR from the MIT through device scaling relationships. These results provide insight into the material phenomena underlying the material's electrical responses, clarifying conditions under which spatial inhomogeneities form in electrically‐biased MIT materials.

artificial neuron↗

AmeriFlux US-MEF Manitou Experimental Forest

This is the AmeriFlux version of the carbon flux data for the site US-MEF Manitou Experimental Forest. Site Description - This site was established on an existing 30-m tower structure at the Forest Service's Manitou Experimental Forest, Colorado. Manitou Experimental Forest is located approximately 38 km northwest of Colorado Springs, within the Pike National Forest. The tower was constructed and used between 2008 and 2013 by NCAR for the BEACHON project and has line power and internet connections. The tower is located in approximately 12 km^2 of ponderosa pine forest and savannah with a land use history of thinning and prescribed burning, though these disturbances have not occurred for many years. The tower is situated in a broad, flat valley that drains to the north. Early research at the site was focused mainly on grazing, while more recently it has turned broadly to the ecology and management of ponderosa pine ecosystems. In 2002, the Hayman Fire burned approximately 56,000 ha to the west and northwest of the tower location.

Frank, John [US Forest Service, Rocky Mountain Res↗