Search NASA⌕ Search

SEARCH · Search NASA

Results for “Firefighting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

NASA System-Wide Safety Wildland Firefighting Operations Workshop Report

On March 9-11, 2022, NASA’s System-Wide Safety Wildland Firefighting Operations Workshop engaged the broader wildland firefighting management ecosystem in a safety-oriented discussion via a virtual platform. This enabled a better understanding of how NASA and community expertise can be leveraged in the safe development of current and future firefighting systems and operations. The goals of the workshop were to: (1) identify and prioritize the top safety-oriented risks, gaps in capabilities, and emerging technologies to enhance wildland firefighting for both near-term and far-term concepts, with a specific focus on aviation operations and (2) engage the stakeholder community in defining emergent safety-oriented scope, roles, responsibilities, and procedures for agents undergoing increasingly complex wildland firefighting operations in information-rich, but uncertain environments. Workshop participants were solicited from wildland firefighting stakeholders across government, industry, and academia. All levels of government were engaged, as NASA sought attendees from federal, state, local, and tribal government agencies. Industry participants from traditional wildland firefighting domains such as data visualization and equipment manufacturers were invited, and corporate attendees from novel application domains such as aerial robotics and autonomous systems were present as well. The top three findings were as follows: (1) Enhancing situation awareness is a safety priority, especially in the use of aerial assets; (2) Timely access to information along with data fusion and integrated displays will enhance safety-critical decision-making both inside and outside aviation contexts; and (3) Tailorable standards and common operating pictures in the field will enhance inter-agency cooperation in the wildland firefighting lifecycle and enable the optimal use of limited resources such as aerial assets. The workshop helped inform NASA of the relevant safety-related wildland firefighting concerns and aided the broader ecosystem in understanding the potential safety-oriented role NASA might play in this community. Increased engagement with crucial governmental stakeholders (e.g., U.S. Forest Service, CAL FIRE, etc.) along with industry partners in cutting- edge information -centric domains is a fundamental next step. Additionally, the workshop findings will help define the first of a series of operationally challenging demonstrations, held in concert with strategic ecosystem partners, known as the Safety Demonstrator Series for NASA’s System-Wide Safety project. The first demonstration is set in the wildland firefighting application domain and will: (1) examine high risk operational scenarios to reduce their overall risk via services, functions or capabilities that act as risk mitigators (or transfer that risk to automated systems better able to tolerate it) and (2) explore novel tools and technologies that will enhance safety margins by enabling non-traditional or neoteric operational paradigms.

wildland firefighting↗

Electronic Escape Trails for Firefighters

A proposed wireless-communication and data-processing system would exploit recent advances in radio-frequency identification devices (RFIDs) and software to establish information lifelines between firefighters in a burning building and a fire chief at a control station near but outside the building. The system would enable identification of trails that firefighters and others could follow to escape from the building, including identification of new trails should previously established trails become blocked. The system would include a transceiver unit and a computer at the control station, portable transceiver units carried by the firefighters in the building, and RFID tags that the firefighters would place at multiple locations as they move into and through the building (see figure). Each RFID tag, having a size of the order of a few centimeters, would include at least standard RFID circuitry and possibly sensors for measuring such other relevant environmental parameters as temperature, levels of light and sound, concentration of oxygen, concentrations of hazardous chemicals in smoke, and/or levels of nuclear radiation. The RFID tags would be activated and interrogated by the firefighters and control-station transceivers. Preferably, RFID tags would be configured to communicate with each other and with the firefighters units and the control station in an ordered sequence, with built-in redundancy. In a typical scenario, as firefighters moved through a building, they would scatter many RFID tags into smoke-obscured areas by use of a compressed-air gun. Alternatively or in addition, they would mark escape trails by dropping RFID tags at such points of interest as mantraps, hot spots, and trail waypoints. The RFID tags could be of different types, operating at different frequencies to identify their functions, and possibly responding by emitting audible beeps when activated by signals transmitted by transceiver units carried by nearby firefighters.

Jorgensen, Charles↗

Deployment of an Advanced Electrocardiographic Analysis (A-ECG) to Detect Cardiovascular Risk in Career Firefighters

INTRODUCTION Sudden cardiac death is the leading cause of line of duty death among firefighters, accounting for approximately 45% of fatalities annually. Firefighters perform strenuous muscular work while wearing heavy, encapsulating personal protective equipment in high ambient temperatures, under chaotic and emotionally stressful conditions. These factors can precipitate sudden cardiac events like myocardial infarction, serious dysrhythmias, or cerebrovascular accidents in firefighters with underlying cardiovascular disease. Screening for cardiovascular risk factors is recommended but not always followed in this population. PHASER is a project charged with identifying and prioritizing risk factors in emergency responders. We have deployed an advanced ECG (A-ECG) system developed at NASA for improved sensitivity and specificity in the detection of cardiac risk. METHODS Forty-four professional firefighters were recruited to perform comprehensive baseline assessments including tests of aerobic performance and laboratory tests for fasting lipid profiles and glucose. Heart rate and conventional 12-lead ECG were obtained at rest and during incremental treadmill exercise testing (XT). In addition, a 5-min resting 12-lead A-ECG was obtained in a subset of firefighters (n=18) and transmitted over a secure networked system to a physician collaborator at NASA for advanced-ECG analysis. This A-ECG system has been proven, using myocardial perfusion and other imaging, to accurately identify a number of cardiac pathologies including coronary artery disease (CAD), left ventricular hypertrophy, hypertrophic cardiomyopathy, non-ischemic cardiomyopathy, and ischemic cardiomyopathy. RESULTS Subjects mean (SD) age was 43 (8) years, weight 91 (13) kg, and BMI of 28 (3) kg/square meter. Maximum oxygen uptake (VO2max) was 39 (9) ml/kg/min. This compares with the 45th %ile in healthy reference values and a recommended standard of 42 ml/kg/min for firefighters. The metabolic threshold (VO2Theta) above which lactate accumulates was 23 (8) ml/kg/min. The chronotropic index, a measure of cardiovascular strain during XT was 35 (8) /L compared with reference values for men of 40 /L. Total cholesterol, LDL-C and HDL-C were 202 (34),126 (29), and 55 (15) mg/dl, respectively. Fifty-one percent of subjects had .3 cardiovascular risk factors, 2 subjects had resting hypertension (BP.140/90), and 23 had pre-hypertension (.120/80 but <140/90). Seven had exaggerated exercise induced hypertension but only one had ST depression on XT ECG, at least one positive A-ECG score for CAD, and documented CAD based on cardiology referral. While all other subjects, including those with fewer risk factors, higher aerobic fitness, and normal exercise ECGs, were classified as healthy by A-ECG, there was no trend for association between risk factors and any of 20 A-ECG parameters in the grouped data. CONCLUSIONS A-ECG screening correctly identified the individual with CAD although there was no trend for A-ECG parameters to distinguish those with elevated BP or multiple risk factors but normal XT ECG. We have demonstrated that a new technology, advanced-ECG, can be introduced for remote firefighter risk assessment. This simple, time and cost-effective approach to risk identification that can be acquired remotely and transmitted securely can detect individuals potentially at risk for line-of-duty death. Additional research is needed to further document its value.

Dolezal, B. A.↗

Toward improved thermal exposure classes for structural firefighters

In the early 1970s, there was an initial effort to quantify the conditions under which firefighters are expected to perform. Harvey Utech led this endeavor by defining three levels of thermal exposure—routine, ordinary, and emergency—which were characterized by combining a range of air temperatures and radiative heat fluxes. In the last half-century, there has been a concerted scientific effort to further understand the conditions to which firefighters are exposed during structural firefighting. Research has been conducted on the resiliency of turnout gear and facepiece lenses, the thermal conditions observed during a structure fire, and the impact of firefighter tactics such as ventilation and suppression. The authors synthesize the results from these research areas to update the original thermal classifications to six categories of exposure—routine, Ordinary I, Ordinary II, Emergency I, Emergency II, and Emergency III—which are more representative of the operating environment and protective equipment thresholds that firefighters should be aware of during firefighting operations and tactical decision-making.

Weinschenk, Craig↗

Deployment of an Advanced Electrocardiographic Analysis (A-ECG) to Detect Cardiovascular Risk in Career Firefighters

INTRODUCTION: Sudden cardiac death is the leading cause of line of duty death among firefighters, accounting for approximately 45% of fatalities annually. Firefighters perform strenuous muscular work while wearing heavy, encapsulating personal protective equipment in high ambient temperatures, under chaotic and emotionally stressful conditions. These factors can precipitate sudden cardiac events like myocardial infarction, serious dysrhythmias, or cerebrovascular accidents in firefighters with underlying cardiovascular disease. PURPOSE: The purpose of this study was to deploy and then evaluate the contribution of resting advanced ECG (A-ECG) in addition to other screening tools (family history, lipid profiles, and cardiopulmonary exercise tests, XT) in assessment of an individual fs cardiac risk profile. METHODS: Forty-four career firefighters were recruited to perform comprehensive baseline assessments including tests of aerobic performance, fasting lipids and glucose. Five-min resting 12-lead A-ECGs were obtained in a subset of firefighters (n=21) and transmitted over a secure networked system to a NASA physician collaborator. Using myocardial perfusion and other imaging as the gold standard, A-ECG scoring has been proven useful in accurately identifying a number of cardiac pathologies including coronary artery disease (CAD), left ventricular hypertrophy, hypertrophic cardiomyopathy, and non-ischemic and ischemic cardiomyopathy. RESULTS: Subjects f mean (SD) age was 43 (8) years, weight 91 (13) kg, and BMI 28 (3) kg/m2. Fifty-one percent of subjects had .3 cardiovascular risk factors. One subject had ST depression on XT ECG, at least one positive A-ECG score for CAD, and documented CAD based on cardiology referral. While all other subjects, including those with fewer risk factors, higher aerobic fitness, and normal exercise ECGs, were classified as healthy by A-ECG, there was no trend for association between risk factors and any of 20 A-ECG parameters in the grouped data.

Dolezal, B. A.↗

Incorporating UAS Traffic Management into Wildland Firefighting Operations: Initial Findings of Subject Matter Expert Interviews

Uncrewed Aircraft Systems (UASs) are being utilized throughout the disaster and emergency response domain, including in wildland firefighting operations. While UASs can offer safety benefits in comparison to crewed aircraft, such as removing the human pilot from the vehicle so that they are not exposed to the same risks and the ability to operate in low-visibility conditions, they are not without tradeoffs. For example, it can be challenging for UAS pilots (UASPs) to build situation awareness of the airspace in which their UAS is operating. In order to address some of the challenges associated with using UASs and provide greater assistance to the firefighters and incident personnel in the wildland firefighting environment, the National Aeronautics and Space Administration (NASA) launched the Advanced Capabilities for Emergency Response Operations (ACERO) project. Building on previous NASA research, ACERO will explore the implementation of a traffic management system in the wildland fire environment to enhance safety and support situation awareness. ACERO draws on the UAS Traffic Management (UTM) system previously demonstrated in an urban environment. However, a traffic management system implemented in the wildland fire environment is expected to look and function much differently in order to meet the unique needs of this domain. At the outset of the ACERO project, interviews were conducted with five UASPs who operate UASs at wildland fire incidents. The interviews focused on exploring UASPs’ initial insights about the application of a traffic management system in wildland firefighting and understanding the unique needs of this environment. The UASPs discussed a range of topics including, the shape, size, and organization of UAS operations in the wildland fire environment, information needs for a user interface, such as traffic and map information, an alerting function when other traffic nears their operation area, and the importance of conformance monitoring. The UASPs also discussed their willingness to share operational information to support safety. In this paper, we describe the foundational work upon which ACERO will build and summarize the information and insights gathered during the UASP interviews, some of which have already informed the development of the ACERO work.

Uncrewed Aircraft System (UAS)↗

Incorporating UAS Traffic Management into Wildland Firefighting Operations: Initial Findings of Subject Matter Expert Interviews

Uncrewed Aircraft Systems (UASs) are being utilized throughout the disaster and emergency response domain, including in wildland firefighting operations. While UASs can offer safety benefits in comparison to crewed aircraft, such as removing the human pilot from the vehicle so that they are not exposed to the same risks and the ability to operate in low-visibility conditions, they are not without tradeoffs. For example, it can be challenging for UAS pilots (UASPs) to build situation awareness of the airspace in which their UAS is operating. In order to address some of the challenges associated with using UASs and provide greater assistance to the firefighters and incident personnel in the wildland firefighting environment, the National Aeronautics and Space Administration (NASA) launched the Advanced Capabilities for Emergency Response Operations (ACERO) project. Building on previous NASA research, ACERO will explore the implementation of a traffic management system in the wildland fire environment to enhance safety and support situation awareness. ACERO draws on the UAS Traffic Management (UTM) system previously demonstrated in an urban environment. However, a traffic management system implemented in the wildland fire environment is expected to look and function much differently in order to meet the unique needs of this domain. At the outset of the ACERO project, interviews were conducted with five UASPs who operate UASs at wildland fire incidents. The interviews focused on exploring UASPs’ initial insights about the application of a traffic management system in wildland firefighting and understanding the unique needs of this environment. The UASPs discussed a range of topics including, the shape, size, and organization of UAS operations in the wildland fire environment, information needs for a user interface, such as traffic and map information, an alerting function when other traffic nears their operation area, and the importance of conformance monitoring. The UASPs also discussed their willingness to share operational information to support safety. In this presentation, we describe the foundational work upon which ACERO will build and summarize the information and insights gathered during the UASP interviews, some of which have already informed the development of the ACERO work.

Uncrewed Aircraft Systems (UAS)↗

Understanding the Impact of Fuel on Surfactant Microstructure of Firefighting Foam

Abstract Aqueous film-forming foam is being phased out due to the environmental impacts of fluorinated surfactants contained in the firefighting foams. To develop an environmentally friendly firefighting foam, it is important to understand the factors controlling the firefighting performance of surfactants. Fuel transport through foam has been considered as a dominant mechanism for foam collapse. Therefore, the impact of fuels (heptane, octane and trimethylbenzene (TMB)) on surfactant microstructure was studied for three different types of surfactants (Capstone, Glucopon, and siloxane) that have applications in firefighting foam. Multiple techniques were used to identify the microstructure and interfacial properties of surfactants with and without exposure to liquid fuel. The ignition time of fuel vapor through foam and solubility of fuel through liquid surfactant solution were measured as well. This work shows fuel solubility has an impact on the surfactant microstructure and interfacial properties. In addition, fuel solubility and vapor pressure affect the ignition time of fuel vapors.

Engineering↗

Firefighters Integrated Response Equipment System

The Firefighters Integrated Response Equipment System (Project FIRES) is a joint National Fire Prevention and Control Administration (NFPCA)/National Aeronautics and Space Administration (NASA) program for the development of an 'ultimate' firefighter's protective ensemble. The overall aim of Project FIRES is to improve firefighter protection against hazards, such as heat, flame, smoke, toxic fumes, moisture, impact penetration, and electricity and, at the same time, improve firefighter performance by increasing maneuverability, lowering weight, and improving human engineering design of his protective ensemble.

Kaplan, H.↗

Fire and Ice - Safety, Comfort, and Getting the Firefighters' Job Done

Daily life for firefighters consists of working with life-threatening hazards in hostile environments. A major hazard is excessive ambient heat. New hazards have arisen from protective gear that was intended to increase survival time of firefighters while finding and rescuing victims. The insulation is so good now that a firefighter's metabolic heat buildup cannot escape. This forces body core temperatures to life threatening levels in about 20 minutes of moderate activity. Using NASA space suit technology, Oceaneering Space Systems developed a liquid cooling garment prototype that will remove up to 250 watts of metabolic heat. After testing and certification as an approved accessory for firefighter use, this garment will be available for use by any individual encapsulated in protective clothing. This demonstration will present a high surface area circulated liquid cooling garment displayed on a mannequin and available for attendees to try on to experience the effects of active cooling.

Foley, Tico↗

The NASA Firefighter's Breathing System Program: A Status Report

The National Aeronautics and Space Administration (NASA), through its Technology Utilization Program, has been making its advanced technology developments available to the public. This has coincided in recent years with a growing demand within the fire service for improved protective equipment. A better breathing system for firefighters was one of the more immediate needs identified by the firefighting organizations. The Johnson Space Center (JSC), based upon their experience in providing life support systems for space flight, was subsequently requested to determine the feasibility of providing an improved breathing system for firefighters. Such a system was determined to be well within the current state of the art, and the Center is well into a development program to provide design verification of this improved protective' equipment. This report - outlines the overall objectives of this program, progress to date, and future planned activities.

McLaughlan, Pat B.↗

NASA firefighters breathing system program report

Because of the rising incidence of respiratory injury to firefighters, local governments expressed the need for improved breathing apparatus. A review of the NASA firefighters breathing system program, including concept definition, design, development, regulatory agency approval, in-house testing, and program conclusion is presented.

Wood, W. B.↗

Improved Clothing for Firefighters

Application of space technology should reduce incidence of injuries, heat exhaustion, and fatigue in firefighters. Using advanced materials and design concepts of aerospace technology, protective gear was fabricated and tested for the heat, face, torso, hand and foot. In tests, it was found that new gear protects better than conventional firefighter gear, weighs 40 percent less, and reduces wearer's energy expenditure by 25 percent.

Abeles, F. J.↗

Improved Gloves for Firefighters

New firefighter's gloves are more flexible and comfortable than previous designs. Since some firefighters prefer gloves made of composite materials while others prefer dip-coated gloves, both types were developed. New gloves also find uses in foundries, steelmills, and other plants where they are substituted for asbestos gloves.

Tschirch, R. P.↗

Firefighters' communication transceiver test plan

The requirements for the operational testing of the firefighters communication transceiver were identified. The major concerns centered around the integrity and reliability of the firefighter/microphone interface. The major concern about the radio hardware was that it be intrinsically safe in hazardous atmospheres and that the system not interfere with the fit or facial seal of self-contained breathing apparatus (SCBA). The greatest concern for operational testing purposes as the reliability and clarity of the line of communication between the firefighter and those on the fireground with whom he must maintain contact. A desire to test any units developed in both training exercises and in real responses to hazardous material incidents was expressed. It is felt that a VOX-microphone built into the SCBA facemask gives the best performance. A voice-pickup product device which combines a bone conduction microphone and a speaker into a single ear mounted unit is examined.

Wallace, R. J.↗

Advanced Transceivers for Firefighters

Report presents concept of improved portable radio transceiver for firefighters. Based in part on study of propagation of radio waves in such environments as high-rise buildings, ships, and tunnels. Study takes into account possible health hazard posed by personal tranceivers and needs and wishes expressed by firefighters in interviews. Conceptual radio attaches to clothing to allow hands-free use; voice-actuated with microphone worn at throat. Speaker placed near wearer's shoulder. Flexible antenna placed either horizontally across shoulders, vertically at one shoulder, or on transceiver itself.

Blood, B. D.↗

High-Capacity, Portable Firefighting Pump

Report describes an evaluation of firefighting module that delivers water at 5,000 gal/min (320 L/s). Is compact, self-contained, portable water pump. Besides firefighting, module used for flood control, pumping water into large vessels, and pump water from sinking ships.

Burns, Ralph A.↗

Firefighting Module

Firefly II pump module is NASA's Marshall Space Flight Center's commercial offshoot of a NASA/US Coast Guard program involving development of a lightweight, helicopter-transportable firefighting module for a quick response in combating shipboard or harbor fires. Operable on land or water, the Amphib One is equipped with 3 water cannons. When all 3 are operating, unit pumps more than 3,000 gallons a minute. Newly developed model used by U.S. Coast Guard can pump 5,000 gallons per minute. It was designed for applications such as firefighting onboard ship fires, emergency dockside water pumping, dewatering ships in danger of sinking, flood control, and emergency water supply at remote locations.

Source record↗