Multi-ignition Fire Complexes Drive Extreme Fire Years and Impacts
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Proceedings of conference on materials for improved fire safety with application to design and development of spacecraft and support equipment
Explore the source record for details and available documents.
We present preliminary results on the development of a fire detection system for partial and low gravity environments. A significant challenge is the design of a system with a low false alarm rate. The detection system therefore has to discriminate between combustion particles, cabin, and lunar dust. Aerosol properties are measured and cross referenced to the target detectors at the Gases and Aerosols from Smoldering Polymers (GASP) Laboratory located at the NASA Glenn Research Center. A computational fluid dynamics plume model is also employed to determine the smoke transport properties of the targeted habitats.
Spacecraft are designed to prevent fires through careful material selection and configuration control combined with electrical design controls and isolation of ignition sources. Despite these best efforts, fire risk still exists due to the potential for configuration changes with the introduction of crew and the potential for a ‘failure of imagination’ by designers in anticipating all fuel and ignition sources. Therefore, fire suppression is a critical capability for any crewed spacecraft as a last resort for crew survival. Many spacecraft suppression methods have relied on fire suppressants such as compressed carbon dioxide, nitrogen, and water. A proposed alternative is depressurization of the cabin as a method to extinguish a fire. Limited testing was conducted during Skylab and showed that depress could result in stirring the air flow and aggravating a fire before extinguishing. However, limited information was available on how the test was conducted. To better characterize the approach, testing was conducted at NASA’s White Sands Test Facility to evaluate the effect of depressurization on material extinguishment. The results showed that depressurization does not provide a safe and effective fire suppression capability. The testing approach, results, and conclusions are described and discussed.
Wildfires impose substantial impacts on communities and regions downwind of wildfire smoke. We present a TEMPO‑enabled workflow that generates value‑added Level‑3 smoke‑plume masks and fire‑front maps for large wildfires, such as 2024 Park Fire, using the self‑supervised deep learning system SIT‑FUSE, along with near‑surface NO₂ predictions produced by a foundation model (Microsoft Aurora). We conclude by outlining a roadmap for expanding these capabilities to additional Western U.S. wildfire events and for delivering actionable tools to stakeholders. This open-source, reproducible workflow provides a scalable framework for cross-agency wildfire monitoring to overcome traditional limitations in smoke-cloud discrimination and air-quality forecasting by incorporating TEMPO data and beyond.
A model developed using Fire Dynamics Simulator (FDS) that aimed to determine the effect of a fire in a spacecraft was validated by data collected during the Saffire campaign. The model used inlet and outlet temperatures and CO 2 concentrations of the Saffire payload where fire spread was taking place to determine the amount of heat and combustion products that made it into Northrop Grumman’s Cygnus vehicle. The model was then validated using six remote sensors in various places in the vehicle, as well as a far field device (FFD) in the open zenith section that was representative of average vehicle values. The current work focuses on using the model to predict fire safety scenarios. One simulation aimed to determine the fate of HCl, which sticks to surfaces. The model prediction showed that the HCl was removed from the atmosphere rapidly. This compared well against the FFD data in the Saffire VI campaign event where a bottle of 5% HCl was released into the vehicle. An additional simulation where the Environmental Control and Life Support System (ECLSS) was shut off once the FFD reached 5 ppm of HCl showed that HCl stayed in the atmosphere considerably longer. Continuing the simulation with the ECLSS activated and after temperatures returned to their initial conditions, resulted in a rapid removal of HCL similar to that observed in the original HCl release scenario model. Finally, a simulation that used the heat release rate from a lithium-ion battery test to determine the effect it would have on a spacecraft was performed. This simulation used a heat addition rate that is considerably higher than what was determined from the burning of solid fuels in the Saffire campaign and hence produced a non-trivial temperature increase in more locations within the vehicle.
Abstract Background For at least four decades, practitioners have recognized advantages of aerial versus ground ignition for maximizing the effectiveness of prescribed fires. For example, larger areas can be ignited in less time, or ignition energy may be variously targeted over an area in accordance with the uneven distribution of fuels. The maturation of wireless communication, geopositioning systems, and unmanned aerial systems (UAS) has enhanced those advantages, and UAS approaches also provide further advantages relative to helicopter ignitions, such as reduced risk to human safety, lower operating costs, and higher operational flexibility. In a long running study at the Bankhead National Forest in northcentral Alabama, prescribed fire has been used for nearly 20 years. Most of the burns have been hand-ignited via drip torches, while some have been aerially ignited via helicopter. In March 2022, for the first time, a UAS was used to ignite prescribed fires across a landscape that included a long-term research stand. This field note relates comparisons of both fire behavior and fuel consumption metrics for the UAS-ignited burn versus previous burns on the same stand, and versus burns of other research stands in the same year. Results The UAS-ignited prescribed fire experienced burn effects similar to those from ground-ignited prescribed fires on the same stand in previous years, as well as those from ground-ignited prescribed fires on other stands in the same year. Conclusion This post hoc analysis suggests that UAS ignition approaches may be sufficient for achieving prescribed burn goals, thereby enabling practitioners to realize the advantages offered by that ignition mode.
Post-monsoon open-field stubble burning in northwestern (NW) India—a key agricultural region known as the “breadbasket”—is a longstanding practice used to clear fields. Satellite observations spanning over two decades have revealed significant upward trends in crop production, vegetative greenness, and the frequency of post-harvest fires, with this last contributing to hazardous air quality during the peak burning season (mid-October to mid-November). Since 2022, thermal anomaly data from Aqua-MODIS and SNPP-VIIRS sensors have shown a sharp decline in reported fire events—an observation that contrasts starkly with the concurrent rise in regional aerosol loading detected from space. This apparent discrepancy became particularly pronounced in 2024–2025, prompting a closer examination using high-temporal-resolution imagery from the Advanced Meteorological Imager (AMI) on the geostationary satellite GEO-KOMPSAT-2A. These observations revealed a clear spike in fire-related signals occurring around and after 4:00 p.m. local time, i.e., outside the typical noon to 2:00 p.m. detection window of the MODIS and VIIRS. A fire detection algorithm exploiting the fire-sensitive shortwave-infrared 3.8 μm signal and its contrast to 11.2 μm infrared observations is designed to adopt AMI observations and applied to its multi-year observations (2019–2025). The resulting fire dataset unambiguously shows a gradual shift in stubble burning activity toward the late afternoon hours beginning in 2022 which is underreported by polar-orbiting satellites. The orbital drift of NASA’s MODIS sensor on the Aqua platform allows detection of some of the gradually shifting fires during afternoon hours, but the MODIS still misses a large number of fires occurring around and after 4 p.m. The AMI’s relatively coarse spatial resolution (~4 km), a consequence of its slant viewing geometry over NW India, imposes inherent limitations on quantifying the full extent of fire occurrences. The operational air quality forecasting models currently assimilate satellite fire detections predominantly captured during early afternoon overpasses of the MODIS and VIIRS. The temporal shift in fire activity complicates such forecast, leading to a substantial underestimation of emissions. Intense stubble burning and the resulting air pollution highlight the need for effective crop residue management practices for mitigating the frequency of open biomass burning and thereby reducing episodic degradation of air quality and its associated public health and economic impacts.
Material selection is a key part of the National Aeronautics and Space Administration (NASA) spacecraft fire safety management plan. Non-flammable textiles are necessary to ensure large-scale flame propagation events do not occur inside a spacecraft. An increased use of textiles and other softgood material is crucial to the pursuit of exploration spaceflight to reduce mass and volume. Exploration spaceflight missions benefit from enriched oxygen cabin environments (>21% O2) by allowing a reduced prebreathe protocol before Extravehicular Activity (EVA). However, materials become exponentially more flammable the higher the O2 levels become. Recent testing within the agency has revealed the lack of commercial-off-the-shelf (COTS) materials that can meet safety requirements in oxygen-enriched environments. Most of the fibers and textiles developed during Apollo (100% O2 cabin environment) and Skylab (>70% O2 cabin environment) are no longer commercially available due to those Programs ending and the discontinuation of raw materials or closure of the original manufacturers. As NASA returns to higher oxygen concentrations inside spacecraft, non-flammable textile development efforts have begun to meet the agency’s needs. This paper discusses those efforts including overall fire safety approach, priorities, interactions with industry, flammability testing and expected challenges.
In some crewed-spacecraft applications, onboard materials are intentionally selected to function as hazard control barriers to prevent powered hardware and/or ignited flammable items from igniting nearby flammable materials by acting as non-breaching, non-flammable containment (e.g., cargo transfer bags, zero gravity stowage racks, and jettison stowage bags on the International Space Station). Historically, flammability self-extinguishment testing of broad acreage or outermost layer materials alone was believed to be sufficient to verify overall flammability compliance. Though required, testing on design features such as threaded seams and zippers was not performed due to the incorrect assumption that flammability performance would not be impacted. However, recent coupon level testing of layups and configurations consisting of multiple materials have revealed that these features may be more susceptible to ignition and fire propagation than the bulk material. Additionally, configurational coupon ignition and propagation testing does not explicitly determine a material’s ability to provide protection to vulnerable flammable hardware. The need to evaluate this gap in assessing material or layup effectiveness as fire barriers between ignition sources and flammable materials led to the development of a new configuration-based fire barrier test. Test setup, relevant configurations, and test validation are discussed. The new barrier test method establishes a configuration for the test apparatus, identifies a conservative ignitor configuration, and defines pass/fail criteria. Test setup, relevant configurations, and test validation are discussed.
Material selection is a key part of the National Aeronautics and Space Administration (NASA) spacecraft fire safety management plan. Non-flammable textiles are necessary to ensure large-scale flame propagation events do not occur inside a spacecraft. An increased use of textiles and other softgood material is crucial to the pursuit of exploration spaceflight to reduce mass and volume. Exploration spaceflight missions benefit from enriched oxygen cabin environments (>21% O2) by allowing a reduced prebreathe protocol before Extravehicular Activity (EVA). However, materials become exponentially more flammable the higher the O2 levels become. Recent testing within the agency has revealed the lack of commercial-off-the-shelf (COTS) materials that can meet safety requirements in oxygen-enriched environments. Most of the fibers and textiles developed during Apollo (100% O2 cabin environment) and Skylab (>70% O2 cabin environment) are no longer commercially available due to those Programs ending and the discontinuation of raw materials or closure of the original manufacturers. As NASA returns to higher oxygen concentrations inside spacecraft, non-flammable textile development efforts have begun to meet the agency’s needs. This paper discusses those efforts including overall fire safety approach, state-of-the-art textile review and testing, an agency-wide assessment of textile needs performed by the NASA Engineering and Safety Center (NESC), the textile development strategy and expected challenges.
In this project, robust heat-flux measurement systems were developed. The heat-flux sensors utilize thermoelectric effects to directly transduce the heat-flux inputs to analog electrical voltage signals. They were constructed from dedicated materials that can withstand temperatures of at least 1000°C and maintain adequate performance at these conditions for prolonged periods of time. The proposed approaches took into account numerous considerations, including system cost, sensor head resilience, sensor footprint, data accuracy, response time, and maintenance requirements. Through modern thermoelectric materials design, methodical materials selection and rigorous testing in materials characterization labs and medium-scale fire research facilities, we have demonstrated functioning laboratory prototypes, upon which one could base industrial heat-flux sensing platforms capable of operating in the challenging high-temperature, corrosive environments of the boilers of coal-fired power plants. A distributed sensor array for heat-flux measurements throughout the furnace water-wall, the superheater area and the economizer coils can provide critical data for the power plant control systems to increase efficiency, improve safety and reduce down times. For example, the combined heat-flux sensor/control systems can contribute to the optimization of burner and boiler operations under flexible loads, the optimization of heat-exchange conditions and overall reduction of heat rate and emissions, the prediction of imminent overheating conditions, and the optimization of the soot-blowing protocols.
Biogenic thermal insulation materials are in high demand because of its carbon-sequestration nature. However, high flammability, moisture condensation, and relatively high thermal conductivity of biogenic material are major concerns for sustainable building applications. In this study, we report the fire-retardant cellulose xerogel insulation nanocomposites derived from hemp fiber recycling and silica xerogel, in which the boric acid treatment improves its fire retardancy. The as-prepared materials show a low thermal conductivity of 31.3 mW/m K, high flexural modulus of 665 MPa, hydrophobicity with the water contact angle of 115°, and fire retardancy with 30% weight loss over a period of burning time 10 min. Overall, this work provides an effective method for the synthesis of fire-retardant biogenic thermal insulation materials and shows a promising way for next-generation bio-based insulation materials.
This proceedings document is a compilation about work performed by a community of researchers from universities, industry and government laboratories across the United States and in Europe and Japan who have recognized the value of the reduced-gravity environment in attacking the fundamental and practical problems of combustion science. On their behalf, I am pleased to present this document to the assembled participants at the Fourth International Microgravity Combustion Workshop, to be held near the NASA Lewis Research Center in Cleveland, Ohio, on May 19-21, 1997.