Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fissile Solutions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Design Optimization of A generic Fissile Solution for Mo99 production using Electron Beam-based Neutron Generator using MCNP+CFD

Molybdenum-99 ( 99 Mo) is a medical isotope used in 80% of all medical imaging procedures today. However, 99 Mo is not directly administered to patients for imaging; its decay product, technetium-99m ( 99 mTc), is a metastable isotope with a half-life of ~6 hours. Such a short half-life does not allow for production, separation, and application to a patient before decaying further. Therefore, the solution is to produce the precursor to 99 mTc, 99 Mo. 99 Mo has a half-life of 66 hours, long enough to produce the material and send it to the desired location before it fully decays. Under National Nuclear Security Administration’s (NNSA) highly enriched uranium (HEU) minimization mission, the Material Management and Minimization (M3) office leads the Molybdenum-99 (Mo-99) program. A major goal of the Mo-99 program is to develop methods of producing 99 Mo using low enriched uranium (LEU) opposed to the traditionally used HEU domestically in the U.S. Internationally, LEU is the new standard for use in research reactors and isotope production facility. In this study, we introduce a generic fissile solution system for 99 Mo production facility meeting the design requirement of 1) LEU usage as fissile material and 2) subcritical fissile system coupled with a horizontal electron beam (E-beam) accelerator. The focus of this research is to optimize a fissile solution configuration for maximum 99 Mo production yield using MCNP model, and ultimately implement the optimized design with computational fluid dynamics (CFD) model to understand thermal hydraulic behavior and solution convection characteristic. The report consists of two parts: 1) isotope yield calculation and criticality analysis with a wide range of parametric test matrix, and 2) thermal hydraulic analysis for solution mixing and cooling assessment.

60 APPLIED LIFE SCIENCES↗

Apparatus and method for generating medical isotopes

An apparatus for generating medical isotopes provides an annular fissile solution vessel surrounding a neutron generator. The annular fissile solution vessel provides for good capture of the emitted neutrons and a geometry that provides enhanced stability in an aqueous reactor. A neutron multiplier and/or a neutron moderator may be used to improve the efficiency and control the criticality of the reaction in the annular fissile solution vessel.

Piefer, Gregory Richard↗

Experimental Steps toward a Density Law for Chlorine-Crediting Criticality Models of Aqueous Plutonium solutions

Criticality accident prevention is an essential safety consideration for all operations involving fissionable and fissile materials. Predictive criticality calculations using advanced neutron transport codes, such as Monte Carlo N-Particle Transport (MCNP), are invaluable tools for designing and implementing operational limits. While indispensable, these tools are limited by the quality and accuracy of the inputs that the user provides to define the modeled system. Parameters such as atomic composition, shape, and material density must be accurately defined to obtain a meaningful result. In the case of material property details for a plutonium model, accurate material characterization data is sometimes sparse. Thus limitations in calculation accuracy can be reduced by improving our knowledge of material properties in the targeted fissile systems. One of the biggest remaining challenges to accurately defining fissile systems is the description of aqueous fissile solutions. Even simple properties, such as density, are not well-known for fissile solutions relevant to nuclear energy and security. Described here are initial efforts undertaken to improve criticality calculation inputs for fissile plutonium chloride solutions in water. This effort is focused on experimentally determining accurate solution characteristics for ternary plutonium chloride/hydrochloric acid/water systems, by measurement of water activity and solution density. The effect of inputting experimental densities for these solutions into MCNP criticality calculations is compared to the traditional approach of modeling an idealized (and fictitious) plutonium-water mixture. Expansion of these efforts to a working density law for aqueous plutonium chloride solutions is also discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Subcriticality Measurements for a Changing Concentration Uranyl Nitrate Solution Tank by Californium Source-Driven Noise Analysis

Subcritical californium source-driven noise analysis (CSDNA) measurements were performed at the Oak Ridge Critical Experiments Facility in 1983 using a stainless-steel tank with an inside diameter of 76.2 cm and a height of 91.4 cm but only filled with a uranyl (93.16 wt.% 235 U) nitrate solution to a height of 76.2 cm for all measurements. The free acid content of the uranyl nitrate solution was less than 0.01 N to minimize hazards in handling. The total available highly enriched uranium for these measurements was 5,296 g. The concentration of the solution was varied from the highest density of 14.71 grams of uranium per liter (g U/L) initially in 16 steps, lowering the concentration to 0.3492 g U/L, and finally using a tank filled with only water. The tank had a Plexiglas lid to minimize evaporation. The Cf source was contained in a re-entrant Lexan tube which could be in the solution parallel to the axis of the cylindrical tank. The detectors were 3 He proportional counters in the solution in shrink-fit tubing to isolate the counters from the fissile solution and adjacent to the outside of the tank. In some cases, the detectors were scintillators adjacent to the outside of the tank. In other cases, the source was external to the tank. Some data presented in this report are from notes and are not in the logbook. The prompt neutron decay constant was obtained from fitting the date from the CSDNA measurements. The purpose of this report is to document the experimental information for the measurements performed so that later, researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (ICSBEP) or a Nuclear Energy Agency benchmark. The prompt neutron decay measurements could be the basis of as International Reactor Physic Benchmark Program. The data from these measurements are available from the Records Management Services Department of Oak Ridge National Laboratory, and the logbook is also available from the ICSBEP at Idaho National Laboratory. Preparation of the present report is part of a larger cooperative effort between Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other USDOE critical experiments facilities using more than 500 operational days of critical facility time.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Critical and Californium Source-Driven Noise Analysis Subcritical Measurements with an Unreflected Cylindrical Tank of Mixed Uranium-Plutonium Nitrate Solution

The reported experiments were performed by Oak Ridge National Laboratory (ORNL) at the Battelle Northwest Laboratory’s (now Pacific Northwest National Laboratory) critical experiments facility at Hanford, Washington in 1981 and used 16 days of critical facility time, not including 10 days for setup and removal of ORNL equipment. These measurements were to assess the capability of the Cf source-driven noise analysis (CSDNA) method to measure the subcriticality (keff) of mixed U-Pu nitrate solutions. In addition to the CSNDA measurements, measurements were also performed near delayed criticality where CSDNA measurements cannot be performed. This report documents the experiments that were not reported at that time by presenting the ORNL experimental results and any online analysis performed during and shortly after the measurements. The mixed nitrate solution had a U concentration at 188 grams per liter (g/L), a Pu concentration of 280 g/L, free acid normality of 2.80, H ion molarity of 5.9 and a specific gravity of 1.754 g/cm 3 , a 240 Pu isotopic content of 7.981 wt. %, and a 235 U isotopic content of 0.724 wt. %. The stainless-steel tank for the solution had an inside diameter of 35.38 cm, an outside diameter of 35.53 cm, a height of 56.72 cm, and bottom thickness of 0.9525 cm. A Zircaloy pipe with a 3.1496 cm outside diameter, a 2.7788 cm inside diameter, and bottom thickness of 0.635 cm was available for insertion of the Cf source in the center of the fissile solution. The Cf source was also located at the outside surface of the tank (solution height varied from 10 to 53 cm) and in the center of the solution (solution height varied from 10 to 60.7 cm). The CSDNA measurements were not analyzed online to determine the subcritical neutron multiplication factors. At all subcritical states, the break frequency noise analysis data was fitted to obtain the prompt neutron decay constant. The neutron multiplication factors were determined for the two configurations of the measurements near delayed criticality. The subcritical neutron multiplication factors from the CNSDA measurements can be obtained with further analysis. However, the near delayed critical configuration, the prompt neutron decay constants, the count rates, and the measured cross and auto power spectral densities can be calculated directly for benchmarking. Much of data presented in this report are from ORNL notes—not in the ORNL logbooks. For the final benchmark analysis, the data from the Battelle Northwest Laboratory (which operated the critical facility in 1981) critical facility logbook should be consulted and be incorporated where appropriate. The purpose of this report is to document the experimental information for the measurements performed so that at a later date researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Criticality Safety Benchmark Program (ICSBEP) or Nuclear Energy Agency benchmark. The data from these measurements are available from the ORNL Records Management Services Department, and the logbook is available from ICSBEP at Idaho National Laboratory. Preparation of the present report is part of a larger cooperative effort between Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other USDOE critical experiments facilities using more than 500 operational days of critical facility time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Application of a Density Law via Python for Aqueous Plutonium Nitrate

A predictive density tool has been developed in Python to reduce bias and uncertainty in nuclear criticality safety calculations for plutonium nitrate systems. The Pitzer Method and an empirical method were implemented into the tool, allowing for plutonium nitrate density calculations. Additionally, the Python tool can generate atom densities for a MCNP6.2 material card using the density from the selected method and directly the densities into a prepared MCNP6 input text file. The material card and density are calculated based on customizable user inputs of plutonium content, nitric acid content, temperature, plutonium isotope weight percentages and impurity concentrations. The Python tool has been validated and verified against the International Handbook of Evaluated Criticality Safety Benchmark Experiments to predict densities within a root mean square error of 1.0% for the Pitzer method and 1.8% for the empirical method. These errors in density were shown to lead to a ±0.5% error in MCNP6.2 calculated k effective for the Pitzer method and a ±1.7% error for the Empirical method. Simultaneous work is also being done at the University of New Mexico and Los Alamos National Laboratory to create a similar tool for plutonium chloride solutions, which aims to provide the accreditation of the chlorine absorption. These capabilities will not only provide more accurate models but also lead the way towards a better understanding of solution systems and potential relaxation in the conservatism of the current aqueous plutonium processing limits.

97 MATHEMATICS AND COMPUTING↗

A Python Tool for Aqueous Plutonium Nitrate Density Law Input Preprocessing in MCNP6

Here, this work develops a predictive density tool in Python, named Plutonium Nitrate Solutions (PuNS), to reduce bias and uncertainty in nuclear criticality safety calculations for plutonium nitrate systems. The Pitzer method and an empirical method were implemented into the PuNS tool to generate atom densities for use in MCNP6 material cards. These material cards are directly prepared into an MCNP6 input text file and are calculated based on customizable user inputs of plutonium content, nitric acid content, temperature, and plutonium isotope weight percentages. The PuNS tool is validated and verified against the International Criticality Safety Benchmark Evaluation Project Handbook experiments and is observed to predict densities within a root mean square error of 0.89% for the Pitzer method and 1.82% for the empirical method. These errors in density lead to up to 1569 pcm difference in MCNP6 calculated k eff for the Pitzer method and up to a 1751 pcm difference for the empirical method when compared to experimental benchmarks. Simultaneous work is also being performed at Los Alamos National Laboratory and the University of New Mexico to create a similar tool for plutonium chloride solutions, named Plutonium Chloride Solution, which aims to provide the accreditation of the chlorine absorption. These capabilities will not only provide more accurate models but also facilitate an improved understanding of solution systems and a potential relaxation in the conservatism of current aqueous plutonium processing criticality safety limits.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Recalculating Dissolver Curves for Critical Parameters for Nuclear Criticality Safety

The dissolver paradox is a phenomenon in criticality safety whereby a high density fissile material is being dissolved in a low fissile density solution and is subcritical before and after dissolution. However, as the metal is being dissolved, there may be an intermediate concentration that leads to a critical state. CCG-184 is a Y-12 report written in 1980 that provided critical parameter data for two separate dissolver paradox scenarios: solid metal spheres and hollow metal spheres with internal moderation effects. The sphere and shell are both surrounded by solution, however the shell contains solution of the same concentration within itself. In 1980, there are limitations to the computational methods to determine critical parameters. These are due to the lower number of energy groups utilized (16-group) at the time, smaller number of established cross-sectional data, as well as a larger uncertainty within the resonance region of neutron energies. With these constraints in mind, these critical parameters are recalculated with newer cross-sectional data, a newer Monte Carlo code: SCALE 6.1.3 using KENO V.a, and a larger number of energy bins.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Semi-Empirical Density Law for Ternary, Homogeneous PuCl 3 /HCl/H 2 O Solutions

Nuclear material operations pose unique hazards that are not encountered in other chemical, energy, or manufacturing industries. One of these hazards is the potential for a nuclear criticality accident when handling fissile isotopes such as 235 U and 239 Pu. These hazards are particularly high when fissile material is dissolved in solution as the neutron behaviors of the system can change rapidly with the physical and chemical changes accessible in solution. Current estimates of solution density used for criticality safety are outdated and hinder fissile material handling. Developing new estimates for these safety calculations requires experimental characterization and the derivation of empirical density models. We have derived a density law describing PuCl 3 /HCl/H 2 O solutions from experimental data characterizing solution density. Density data was treated using a Pitzer-derived eight-parameter equation, defining density as a function of analyte concentrations, temperature, and interactions between these variables. The model is predictive across the concentration and temperature ranges from which it was derived. The potential effects of varying oxidation states of plutonium, which are easily accessible in aqueous media, on the bulk solution density of the ternary system were also investigated. The resulting Pitzer-derived density law was applied to a nuclear criticality safety model, and the impact of the experimental characterization of solution density relative to previous estimates was demonstrated to be significant and suggest that the current approach to estimating density in nuclear criticality safety calculations may lead to overly conservative controls.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Verification of Subcritical Limits in ANSI/ANS-8.1-2014

The first edition of the current American National Standards Institute (ANSI)/American Nuclear Society (ANS) standard ANSI/ANS-8.1-2014, “Nuclear Criticality Safety in Operations with Fissionable Materials Outside Reactors,” was published in 1964 as ASA N6.1-1964, “Safety Standard for Operations with Fissionable Materials Outside Reactors.” In 1969, that standard was revised as ANSI N16.1-1969, “Nuclear Criticality Safety in Operations with Fissionable Materials Outside Reactors.” ANSI N16.1-1969 includes a variety of subcritical limits (SCLs) for uniform aqueous solutions and metals containing fissile nuclides of 233 U, 235 U, and 239 Pu. Furthermore, SCLs are also included for uranium-water lattices. In the 1983 version of ANSI/ANS-8.1 (a revision of ANSI N16.1-1975), the suite of SCLs in the standard was expanded to include 235 U enrichment limits for homogeneous uranium-water mixtures and dry/damp oxides, uniform aqueous solutions of low-enriched uranium, and uniform aqueous mixtures of Pu(NO 3 ) 4 containing 240Pu in addition to the SCLs included in ANSI N16.1-1969. The SCLs have changed little in subsequent revisions (ANSI/ANS-8.1-1998 and ANSI/ANS-8.1-2014). The ANSI/ANS-8.1-2014 standard is currently being revised to include new SCLs (uranium metal and compounds with enrichments up to 20 wt% 235 U) and possible updates to the current SCLs already in the standard, although these new/updated SCLs will not be available to the nuclear criticality safety (NCS) community for a number of years. The original bases for these SCLs were documented in papers in journals such as Nuclear Science and Engineering and in ANS meeting transactions; however, these bases are ambiguous enough that sites and regulators in the United States have not widely endorsed them for safety purposes. Overall, the purpose of this paper is to present the results of a comparison study for the SCLs in the ANSI/ANS-8.1-2014 standard using modern codes (SCALE and MCNP) and cross sections (ENDF/B-VIII.0) to provide some assurance about their quality (bias and bias uncertainty) for use in NCS applications and for consideration by the ANS-8.1 Working Group as a reference for future revisions.

42 ENGINEERING↗

Evaluation of the Potential for Precipitation of Solids during Storage of Non-Aluminum SNF Solutions

Non-aluminum clad spent nuclear fuels (NASNF) stored in the L-Area basin will be dissolved in H-Canyon using the 6.3D electrolytic dissolver. The solutions will be stored in either the hot or warm canyon until the preparation of a sludge batch for the Defense Waste Processing Facility. Spent nuclear fuel solutions could be stored for 1-2 years before transfer to the H-Area Tank Farm depending on the interval between sludge batches. The solution level in the storage tanks will be maintained; therefore, precipitation of solids due to evaporation is not an issue. However, the precipitation of solids from completely dissolved SNF due to solution instabilities has been observed during intermediate storage of solutions generating hydrated oxides.The presence of fissile material in these solids is generally associated with zirconium molybdate, which is known to act as a host lattice for Pu and can carry the actinides upon precipitation. The formation of zirconium molybdate solids which carry fissile material is a potential concern for the storage of NASNF solutions. To address this concern, the Savannah River National Laboratory performed a literature review to identify knowledge gaps which may require experimental work to determine if the formation of solids is a concern during storage of these solutions. Based on the literature review, the precipitation of zirconium molybdate solids from the Campaign 1 NASNF solutions during intermediatestorage is expected. This conclusion is supported by the identification of zirconium molybdate solids found on the H-Canyon 6.1D Dissolver MK-12 insert spacer. The formation of the zirconium molybdate solids is attributed to hydrolysis and radiolytic processes in the nitric acid solution. As the molybdate solids form, U and Pu can substitute for Zr in the crystal lattice resulting in co-precipitation. Generally, the Pu substitutes directly into the crystal lattice during precipitation while the U associated with the molybdate solids more likely absorbs from the solution. The U in the NASNF solutions is present as uranyl nitrate, a 2+ cation which will not substitute as easily into the molybdate crystal lattice for the Zr 4+ ion.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Calculations of Subcritical Limits in ANSI/ANS-8.1 [Slides]

ANSI/ANS-8.1 standard “Nuclear Criticality Safety in Operations with Fissionable Materials Outside of Reactors” provides subcritical limit (SCL) values for several single- and multiple-parameter limits for fissile nuclides, including, uniform aqueous solutions and metals containing nuclides of 233 U, 235 U, and 239 Pu, uranium-water lattices, homogeneous uranium-water mixtures of dry/damp oxides, uniform aqueous solutions of low-enriched uranium, and uniform aqueous mixtures of Pu(NO 3 ) 4 containing 240 Pu

ENDF↗

Gandolinium poison solubility testing for the downstream impacts from accelerated basin de-inventory

The Accelerated Basin De-inventory (ABD) Program at the Savannah River Site (SRS) is designed to accelerate the de-inventory of L-Basin and accelerate the Spent Nuclear Fuel (SNF) Disposition mission. Spent fuel will be dissolved in H-Canyon without recovery of uranium. The dissolver solutions will be temporarily stored, pH-adjusted to excess hydroxide (which will facilitate precipitation of metal oxides/hydroxides), transferred to the Concentration, Storage, and Transfer Facility (CSTF), and subsequently immobilized in the Defense Waste Processing Facility (DWPF) during planned sludge batch campaigns. ABD accelerates basin closure, significantly reduces programmatic risk, and greatly reduces the lifecycle budget requirements for the site by eliminating the need for a SNF drying and packaging capability. The ABD approach represents a significant change to the clean-up approach for the SRS. However, the increased fissile loading in sludge batches, due to the dissolver solutions, requires investigation to ensure fissile limits are efficiently and safely managed; higher fissile loadings in the glass are projected to be two to three times higher than the current fissile concentration limit of 897 g/m 3 and will be addressed in a future report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The LASL program in nuclear pumped liquid lasers

The development of nuclear-pumped, liquid-based lanthanide ion lasers is discussed. Early investigations of lanthanide ion lasers have lead to solid-state and gaseous neodymium lasers, and a demonstration of lasing in the liquid state. Solvents containing organic chelating agents have been employed in liquid Eu(+3) and Tb(+3) lasers to extend fluorescence lifetimes, however aprotic solvents have been found to enable the development of large-scale liquid lasers. The advantages to be gained from high-power nuclear-pumped lasers based on lanthanide solutions include the high density of fissile materials possible, and a nuclear pumping cell which can operate in either a nuclear or optical pumping mode is being fabricated at the Los Alamos Scientific Laboratory to investigate the nuclear pumping of liquid lanthanide ion lasers. Areas that need exploration before specific laser design features can be considered include energy channeling within the liquid upon excitation, radiation damage due to solvent dissociation, and reactor technology for the development of a self-critical liquid reactor.

Mansfield, C. R.↗

Validation and Independent Uncertainty Analysis of the MIX-SOL-THERM-003 ICSBEP Benchmark

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) was started in 1992 by the United States Department of Energy and later in 1995 became an international project with contributions from 22 countries. The project is now organized by the OECD (Organisation for Economic Co-operation and Development) Nuclear Energy Agency (NEA). In its most recent iteration, the ICSBEP handbook contains over five thousand evaluations of critical, near-critical, and subcritical experiments conducted in facilities all around the world. These benchmarks serve as valuable information for criticality safety engineers who can use them to validate calculation techniques and establish minimum subcritical margins for operations with fissionable materials. The benchmarks in the handbook are categorized by their fissile material composition, material form (oxide, solution, or metal), and fission energy spectra. This is especially useful for those looking for benchmarks similar to a system they are working on to compare methods and identify trends. The ICSBEP Handbook Uncertainty Guide is document outlining recommended practices and methods for determining uncertainties in these benchmarks. Quantifying these uncertainties thoroughly is crucial as it allows a higher degree of confidence that data used from them is valid and relevant. The guide stresses the importance of a thorough and well documented uncertainty analysis when evaluating an experiment. All measured values of a system, whether they be dimensions or material compositions, have a certain amount of uncertainty associated with them and can be analyzed one by one to determine their effects on the system. Many evaluated benchmarks in the handbook present this in detail, however some do not, mostly earlier evaluations performed in the 1990’s and early 2000’s. Recently at Los Alamos National Laboratory (LANL), the Nuclear Criticality Safety Division (NCSD) of LANL has been validating MCNP6.2 ® input files of criticality benchmarks for use by Whisper, a criticality safety code developed at LANL. This effort is also part of the OECD NEA Working Party on International Nuclear Data Evaluation Co-operation (WPEC) Subgroup 45, also known as Validation of Nuclear Data Libraries (VaNDaL). The goal of VaNDaL is to compile a set of validated simulation inputs for use in validating nuclear data and simulation codes. As part of these efforts, one of the benchmarks reviewed was the MIX SOL-THERM-003 ICSBEP benchmark. This paper provides an independent uncertainty analysis of this benchmark experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SCALE 6.2.4 Validation: Nuclear Criticality Safety

The computational bias of criticality safety computer codes must be established through the validation of the codes to critical experiments. A large collection of suitable experiments has been vetted by the International Criticality Safety Benchmark Evaluation Project (ICSBEP) and made available in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook). More than 600 cases from this handbook have been prepared and reviewed within the Verified, Archived Library of Inputs and Data (VALID), which is maintained by the Reactor and Nuclear Systems Division at Oak Ridge National Laboratory. The performance of the KENO V.a and KENO-VI Monte Carlo codes within the SCALE 6.2.4 code system is assessed using the VALID models of benchmark experiments. A range of nuclear cross section libraries based on Evaluated Nuclear Data File (ENDF)/B-VII.1 in both multigroup (MG) and continuous energy (CE) formats is considered. The critical experiments available to validate the KENO V.a code cover 15 broad categories of systems. These systems use a range of fissile materials, including a range of uranium enrichments, various plutonium isotopic vectors, and some mixed uranium/plutonium oxides. The physical forms of the fissile material also vary and are represented as metal, solutions, or arrays of rods or plates in a water moderator. The neutron energy spectra of the systems also vary and cover fast, intermediate, mixed, and thermal spectra. Over 550 of the total cases use the KENO V.a code for the four nuclear data libraries considered in this report.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimization of the Post-Operational Phase on Two Belgian Multi-Unit Nuclear Power Plants: the Case of the Non-Fissile Irradiated Core Items - 20156

The current legal framework in Belgium foresees the progressive phase out of nuclear power between October 2022 (Doel 3) and December 2025 (Doel 2). Upon its definitive shutdown, each unit of the Tihange and Doel sites will enter a Post-Operational Phase (POP) and be prepared for its Decontamination and Decommissioning (D and D). Prior to obtaining the D and D license, the Operator Electrabel is legally required to remove any non-fissile irradiated core items stored in the deactivation pools. The non-fissile irradiated core items consist essentially of control rods, poison rods and source thimbles as well as thimble plugs and foreign materials irradiated during operation: - Their significant content in highly radiant radionuclides (up to 6 TBq of Co-60 per kg of irradiated material) renders all existing operational waste management processes inadequate due to insufficient biological shielding; - Their high concentrations in long-lived radionuclides call for their disposal in a geological repository for which no final design nor waste acceptance criteria are expected prior to 2050. Uncertainties in the Belgian energy supply and security, however, require the Operator to be prepared for a partial nuclear phase out, where one or more units would benefit from lifetime extension while the remaining units would undergo decommissioning. The present paper aims at presenting how Electrabel, in partnership with Tractebel, addressed this challenge by maximizing the use of synergies within the respective sites as well as between both sites themselves, all the while accounting for site specificities. The most recent results and state of progress of the project will be detailed and the first lessons learned will be shared. The project has been split in multiple tasks and phased as follows: - An inventory phase aimed at mapping the contents, origin, composition and history of the non-fissile irradiated core items; - A pre-characterization phase based on neutron activation models; - A waste sorting phase aimed at separating waste forms for which an evacuation route exists from those for which such route does not exist; - A feasibility phase aimed at exploring all possible scenarios for the management of non-fissile irradiated core items and identifying the optimal feasible solution for each site; - A preparation phase (currently ongoing), developing further the optimal solution and ensuring that back-up solutions are available for any foreseeable change of context (licensing issue, modification in the nuclear phase-out program, etc.) and initiating early contacts with potential subcontractors for segmentation works and cask manufacturers, as well as the Belgian regulatory body and waste management agency. This phase also foresees the investigation of destructive and non-destructive radiological measurements to support the detailed characterization of the waste forms; - A realization phase (future work). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗