Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fixed Field Accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Study of a Fixed Field Accelerator as a Driver for Proton Driven Plasma Wakefield Acceleration

A fixed field accelerator (FFA) scheme is studied that is aimed to provide a continuous stream of high-energy proton bunches at a rate of up to 20 kHz. The bunches can be used to drive plasma wakefields capable of acceleration of leptons in a single stage for a lepton collider at the Higgs and the top-mass scales. The proposed FFA is assumed to have a circumference of 6900 m and is designed to accelerate proton bunches from 150 GeV to 500 GeV .

43 PARTICLE ACCELERATORS↗

Modeling and implementation of vertical excursion FFA in the Zgoubi ray-tracing code

Vertical Fixed Field Accelerators (vFFAs) feature complex and highly non-linear magnetic fields, which require simulation codes allowing step-wise particle tracking. Methods to model the 3D magnetic field of scaling vFFAs have been developed in the ray-tracing code Zgoubi. The field modeling and particle tracking methods include the field non-linearities, the fringe fields, and the field superposition of neighboring magnets. The procedure implements the vFFA analytical field expressions, allowing design studies and parameter optimizations using the Zgoubi built-in fit method. The vFFA procedure has been applied to a ten-fold symmetry ring with a triplet focusing structure designed to accelerate protons from 3 MeV to 12 MeV and studied under the ISIS-II proton driver prototype project. Results from particle tracking in externally generated 3D semi-analytical field maps and the developed vFFA analytical model are shown to be in excellent agreement.

43 PARTICLE ACCELERATORS↗

Tune compensation in nearly scaling fixed field alternating gradient accelerators

In this paper, we investigate the stability of the particle trajectories in fixed field alternating gradient accelerators (FFAs) in the presence of field errors. The emphasis is on the scaling radial sector FFA type: A collaboration work is ongoing in view of better understanding the properties of the 150 MeV scaling FFA at Kyoto University Institute for Integrated Radiation and Nuclear Science in Japan and progress toward high-intensity operation. Analysis of certain types of field imperfections revealed some interesting features that required the development of an analytical model based on the scalloping angle of the orbits. This helped explain some of the experimental results as well as generalize the concept of a scaling FFA to a nonscaling one for which the tune variations obey a well-defined law. Based on this, a compensation scheme of tune variations in imperfect scaling FFAs is presented. This is the cornerstone of a novel concept of a fixed tune FFA in which the scaling is not achieved at every azimuthal position of the ring but rather in an average sense.

43 PARTICLE ACCELERATORS↗

Compact, Achromatic Non-scaling FFAG Accelerator for HEP, Commercial and Medical Applications (CRADA FRA-2008-0005 Final Report)

Proton and light-ion accelerators have many research and medical applications, but the current state of technology in accelerators severely limits their widespread use: (1) synchrotrons have an intrinsic low duty cycle and become quite large for light ions; and (2) cyclotrons do not have energy variability and require complex superconducting magnets for high energy. A new concept in non-scaling Fixed-Field Alternating-Gradient (FFAGs) has been invented that incorporates both the energy variability of the synchrotron and the high duty cycle of the cyclotron. The concept uses normal-conducting, combined-function magnets that apply only constant (dipole) and linear-gradient (quadrupole) fields to stabilize the accelerator. This project will develop an optimized design for a new non-scaling and cost-effective innovation in FFAG accelerators. The accelerator design will have optics that can stably accelerate protons to 250 MeV (or higher) and carbon ions to =200 MeV, an energy considered ideal for radiation therapy. Phase I will optimize, fully simulate, and demonstrate the feasibility of this accelerator. Commercial Applications and other Benefits as described by the awardee: The fixed-field acceleration concept should eliminate some of the most pronounced technical difficulties, expense, maintenance, and required expertise faced in conventional proton and light-ion accelerators. In addition to the application for high energy physics, these accelerators should have application in cancer treatment, radiopharmaceuticals, and medical isotope production, and materials science.

43 PARTICLE ACCELERATORS↗

Paraxial, Thin-Lens Analysis of Fixed-Tune, Non-Scaling FFAs with Two Magnets per Cell

Fixed-field accelerators (FFAs) have closed orbits that change as a function of beam momentum. It is sometimes useful to avoid various resonances by keeping the tunes constant as these orbits change. A well-known example is the scaling FFA where the entire beam orbit and optics are geometrically scaled as a function of momentum. However, this is stricter than necessary: cells with three or more lenses can have fixed tunes even when the focussing strengths in the lenses change. Recently, Dejan Trbojevic has found a pair of nonlinear magnets that produce fixed tunes and fixed beta functions while not being a scaling FFA. This improves on a more approximate solution in. Notably a scaling FFA would require one magnet to be entirely reverse-bending, whereas the Trbojevic solution does not do this and instead resembles an intermediate point between the traditional scaling field profiles and the nonscaling profiles centred around a momentum with equal and positive fields. This suggests there are at least three levels of stringency that one can apply to a fixed-tune FFA design: 1. Fixed cell tunes (in both planes) as a function of momentum; 2. Fixed optics (beta functions) as a function of momentum; 3. Similarity of all orbits via a scaling symmetry law ↔ traditional scaling FFA. This note studies the interesting case #2 above (#3 being fully characterised by the orbit at a single energy) in the simplest possible example: a cell of two thin lenses in the small angle (paraxial) approximation.

43 PARTICLE ACCELERATORS↗

Permanent Magnets for the CEBAF 24GeV Upgrade

An upgrade of the CEBAF facility to double its present energy of 12GeV has been proposed. To provide double the number of linac passes using the existing five stacked arc beamlines, some beamlines are replaced by fixed-field accelerator (FFA) arcs, allowing multiple energies to pass through the same magnets. A solution is presented in which two of the existing electromagnetic beamlines are replaced with permanent magnet non-scaling FFA arcs, as demonstrated at CBETA. The two-stage design reduces peak magnetic field and synchrotron radiation loss compared to using a single stage. FFAs do not pulse their magnets, making permanent magnets a promising and power-efficient technology option. However, the magnetic field requirements are still at the high end of accelerator permanent magnets produced thus far (1.6T peak on beam), while the magnets must also be combined-function, having a gradient with a dipole offset. Designs using a novel oval aperture and open midplane within an adapted Halbach magnet are presented.

Brooks, S. J.↗

Benchmark Midplane Field for Medical FFA

This is a lattice cell for a fixed-field medical accelerator, transmitting protons from 10–250 MeV. The goal is to have fixed tunes throughout this energy range. The cell is based on the lattice Feb7 2024 ProtonAccelerator.f90 from Dejan Trbojevic and had the magnet field profiles re-optimised to attain fixed tunes with realistic magnet fringe fields.

43 PARTICLE ACCELERATORS↗

Artificial or variable gravity attained by tether systems

The simplest orbiting tethered system demands for stability that the mass centers of two end bodies be displaced above and below the position of zero acceleration. Therefore, the contents of the end bodies are subjected necessarily to acceleration fields or artificial gravity whose magnitudes depend on the dimensions and masses of the system. If the length of the tether changes, so do the fields. Even for a fixed tether length, the acceleration field at a location in the system may be somewhat variable unless special means are employed to maintain a constant value. These fundamental properties of a tethered system can be used to advantage if small or variable acceleration fields are desired for experimental or operational reasons. This potential use involves a few expressions from a formulation of tether system dynamics. Some of these formulae were collected for convenient use. Two and three body tethered equilibrium equations are explained. A special application of acceleration field control using a tether system is attainment of near-zero gravity. In this applicaition, even small variations about zero become a critical matter.

Lundquist, C. A.↗

Widening and distortion of the particle energy distribution by chromaticity in quasi-isochronous rings

This paper reports the observation of beam energy widening and distortion from Gaussian due to a nonvanishing horizontal chromaticity at a quasi-isochronous storage ring. The result originates from an average path-length dependence on the betatron oscillation amplitudes, which is intimately correlated to the transverse chromaticities. It is the first experimental validation of the impact of such a nonlinear transverse-longitudinal coupling effect on the equilibrium beam characteristics in a storage ring. The results could be important for quasi-isochronous rings, steady-state microbunching, nonscaling fixed-field alternate gradient accelerators, etc., where very small momentum compaction or large chromaticity is required.

43 PARTICLE ACCELERATORS↗

Exploratory splitter bend system designs for FFA@CEBAF

An upgrade to the Continuous Electron Beam Accelerator Facility (CEBAF) at the Thomas Jefferson National Accelerator Facility (JLAB) is anticipated to provide an electron beam of over 20 GeV using the existing superconducting-RF linear accelerator and new fixed-field alternating (FFA) gradient recirculation arcs made up of Halbach-style permanent magnets. In the current design, the FFA arcs will carry six beams with energies of approximately 11, 13, 16, 18, 20, and 22 GeV which will require horizontal splitter lines to match the beam from the preceding linac. In this paper, we describe two alternative splitter beamline designs that are tuned to match the beam's Twiss parameters, R56, time-of-flight, bend-plane offset, and dispersion into the FFA cells.

Accelerator Physics↗

Status of Error Correction Studies in Support of FFA@CEBAF

In pursuit of higher energy at the Continuous Electron Beam Accelerator Facility (CEBAF), the FFA@CEBAF energy upgrade study is considering the implementation of a novel technology to recirculate electron beam through the accelerating gradient of the machine more times. The technology in question is Fixed-Field Alternating-gradient (FFA) bending accelerator arcs: these arcs may replace the present highest energy electromagnetic (EM) arcs, and due to a much wider energy acceptance allow several more passes. The survey and beam error tolerance of the FFA arcs need to be well understood prior to commissioning, in addition to the limits of planned correction magnets and diagnostics. This work explores the current state of error tolerance and correction studies in FFA arcs at CEBAF.

Benesch, J.↗

Current status of conceptual horizontal splitter design for FFA@CEBAF energy Upgrade

Jefferson Lab’s Continuous Electron Beam Accelerator Facility (CEBAF) is currently investigating the feasibility of upgrading its maximum operating energy using Fixed-Field Alternating-gradient (FFA) recirculating arcs to increase the total number of recirculations of the beam through the pair of LINACs. These FFA arcs will be composed of permanent magnets, with small Panofsky-style multipole correctors. In order to control the beam parameters through these FFA arcs, horizontal splitters must be used. The geometrical and physical constraints, as well as the beam matching requirements are very restrictive, complicating the design. This work will show the current status of the most mature design, which includes matching solutions, as well as options for extraction of the beam.

Accelerator Physics↗

Status Update of Permanent Magnet Radiation Resiliency Studies at CEBAF

The proposed energy upgrade of the Continuous Electron Beam Accelerator Facility (CEBAF) incorporates Fixed-Field Alternating-gradient (FFA) arcs utilizing permanent magnet technology. Given the radiation environment within the CEBAF tunnel enclosure, validating the long-term magnetic stability of these materials is a critical step for the project's technical feasibility. This contribution presents an overview of the ongoing permanent magnet radiation resiliency program at Jefferson Lab. We briefly review the experimental methodology used to monitor demagnetization in situ and summarize the operational experience from the initial data-taking campaign. Furthermore, we discuss the upgrades implemented for the second exposure campaign, currently underway, which aims to refine dose correlation and reduce systematic uncertainties. We report on the general status of the program and the roadmap for certifying permanent magnet optics for the proposed upgrade energies.

Bodenstein, R. [Thomas Jefferson National Accelera↗

Error and Correction Analysis for the FFA@CEBAF Energy Upgrade

An energy upgrade design for the Continuous Electron Beam Accelerator Facility (CEBAF) is under development, using fixed field alternating gradient (FFA) return arcs to recirculate electron beam up to an additional five times through the accelerating structures at CEBAF. A necessary component of any large accelerator is a beam steering and optical correction system. Small environmental changes and system errors can lower beam quality or even shut down the machine; and in pursuit of the scientific mission of JLab, high quality electron beams must be delivered to the experimental halls on a predictable schedule. Correction in the novel FFA arcs of the current upgrade design is complicated by several factors. These complexities inform the choice of correction algorithm structure and parameter values. A baseline algorithm in addition to diagnostic and correction hardware configuration is presented. The effect of this correction protocol is shown with respect to estimated errors, and several possible extensions of the algorithm are discussed. This work presents an important proof of concept for the FFA@CEBAF design effort, and provides a functional correction strategy which may be simply adjusted and optimized for future design changes.

Coxe, Alex [Old Dominion Univ., Norfolk, VA (Unite↗

Application of radiochromic gel dosimetry to commissioning of a megavoltage research linear accelerator for small–field animal irradiation studies

To develop and implement an efficient and accurate commissioning procedure for small-field static beam animal irradiation studies on an MV research linear accelerator (Linatron-M9) using radiochromic gel dosimetry. The research linear accelerator (Linatron-M9) is a 9 MV linac with a static fixed collimator opening of 5.08 cm diameter. Lead collimators were manually placed to create smaller fields of 2 × 2 cm 2 , 1 × 1 cm 2 , and 0.5 × 0.5 cm 2 . Relative dosimetry measurements were performed, including profiles, percent depth dose (PDD) curves, beam divergence, and relative output factors using various dosimetry tools, including a small volume ionization chamber (A14), GAFCHROMIC™ EBT3 film, and Clearview gel dosimeters. The gel dosimeter was used to provide a 3D volumetric reference of the irradiated fields. The Linatron profiles and relative output factors were extracted at a reference depth of 2 cm with the output factor measured relative to the 2 × 2 cm 2 reference field. Absolute dosimetry was performed using A14 ionization chamber measurements, which were verified using a national standards laboratory remote dosimetry service. Absolute dosimetry measurements were confirmed within 1.4% (k = 2, 95% confidence = 5%). The relative output factor of the small fields measured with films and gels agreed with a maximum relative percent error difference between the two methods of 1.1 % for the 1 × 1 cm 2 field and 4.3 % for the 0.5 × 0.5 cm 2 field. These relative errors were primarily due to the variability in the collimator positioning. The measured beam profiles demonstrated excellent agreement for beam size (measured as FWHM), within approximately 0.8 mm (or less). Film measurements were more accurate in the penumbra region due to the film’s finer resolution compared with the gel dosimeter. Following the van Dyk criteria, the PDD values of the film and gel measurements agree within 11% in the buildup region starting from 0.5 cm depth and within 2.6 % beyond maximum dose and into the fall-off region for depths up to 5 cm. The 2D beam profile isodose lines agree within 0.5 mm in all regions for the 0.5 × 0.5 cm 2 and the 1 × 1 cm 2 fields and within 1 mm for the larger field of 2 × 2 cm 2 . The 2D PDD curves agree within approximately 2% of the maximum in the typical therapy region (1–4 cm) for the 1 × 1 cm 2 and 2 × 2 cm 2 and within 5% for the 0.5 × 0.5 cm 2 field. This work provides a commissioning process to measure the beam characteristics of a fixed beam MV accelerator with detailed dosimetric evaluation for its implementation in megavoltage small animal irradiation studies. Radiochromic gel dosimeters are efficient small-field relative dosimetry tools providing 3D dose measurements allowing for full representation of dose, dosimeter misalignment corrections and high reproducibility with low inter-dosimeter variability. Altogether, radiochromic gels are valuable for fast, full relative dosimetry commissioning in comparison to films for application in high-energy small-field animal irradiation studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CBETA: The first multi-pass superconducting linear accelerator with energy recovery

Energy recovery has been achieved in a multipass linear accelerator, demonstrating a technology for more compact particle accelerators operating at higher currents and reduced energy consumption. Energy delivered to the beam during the first four passes through the accelerating structure was recovered during four subsequent decelerating passes. High-energy efficiency was achieved by the use of superconducting accelerating cavities and permanent magnets. The fixed-field alternating-gradient optical system used for the return loop successfully transported electron bunches of 42, 78, 114, and 150 MeV in a common vacuum chamber. This new kind of accelerator, an eight-pass energy recovery linac, has the potential to accelerate much higher current than existing linear accelerators while maintaining small beam dimensions and consuming much less energy per electron.

43 PARTICLE ACCELERATORS↗

Status of CEBAF Upgrades

Extending CEBAF energy reach by increasing the number of recirculations, while using the existing SRF system is being explored. Proposed energy upgrade is based on a new approach to multi-pass acceleration of electrons in a single Fixed Field Alternating Gradient (FFA) beam line, configured with Halbach-style permanent magnets. Encouraged by recent success of CBETA, a proposal was formulated to nearly ?double? CEBAF energy by replacing the highest energy arcs with a pair of FFA arcs. The new non-scaling FFA arcs would support simultaneous transport of additional 6 passes with energies spanning a factor of two. One of the challenges of the multi-pass (11) linac optics is to assure uniform focusing in a vast range of energies, in a fixed field lattice. Here, we propose a triplet lattice that would provide a stable periodic solution covering energy ratio of 1:33. The current CEBAF injection at 123 MeV, makes optical matching in the first linac virtually impossible due to extremely high energy span ratio (1:175). Replacement of the current injector with a 650 MeV recirculating injector will alleviate that problem. Orbital and optical matching from the FFA arcs to the linacs is implemented as a compact non-adiabatic insert. Presented scheme would promise to deliver a 22 GeV beam with normalized emittance of 76 mm·mrad and with a relative energy spread of 1×10-3. Further recirculation beyond 22 GeV is limited by large, 974 MeV per electron, energy loss due to synchrotron radiation

Bogacz, Alex↗