Search NASASearch

SEARCH · Search NASA

Results for “Fixed frequency tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Detecting isolated resonance curves using fixed frequency voltage control tests

Isolated resonance curves, or isolas, are resonance branches of the harmonically forced system that exist separately from the main nonlinear forced response curve, leading to excessive vibrations. Traditional stepped or swept sine simulations and tests rely on continuation along the frequency parameter, typically resulting in a jump phenomenon along the primary resonance branch, prior to the disconnected isola. The main objective of this research is to propose an approach to identify isolated resonance curves by performing continuation along the input amplitude that initializes the response from a low-amplitude solution in the linear regime. Furthermore, this is achieved with the open-loop fixed frequency voltage control method that continues along the shaker voltage parameter and measures the so-called S-curves, which are theoretically a continuous solution branch that connect to the isola. The methodology is demonstrated on a fixture-wing-pylon assembly with a vibro-impact nonlinearity localized in a pylon subcomponent attachment. Multi-harmonic balance simulations are deployed to compute both the nonlinear forced response curves and S-curves to demonstrate the isola detection strategy on a reduced-order finite element model of the nonlinear system. Swept sine and fixed frequency voltage control tests are then conducted on the physical structure to demonstrate the isola detection experimentally, revealing the existence of the large amplitude vibrations that are undetected in the forces levels and frequencies measured with traditional frequency sweeping.

Characterization and Analytical Technique

QSHS: an axion dark matter resonant search apparatus

We describe a resonant cavity search apparatus for axion dark matter constructed by the quantum sensors for the hidden sector collaboration. The apparatus is configured to search for QCD axion dark matter, though also has the capability to detect axion-like particles, dark photons, and some other forms of wave-like dark matter. Initially, a tuneable cylindrical oxygen-free copper cavity is read out using a low noise microwave amplifier feeding a heterodyne receiver. The cavity is housed in a dilution refrigerator (DF) and threaded by a solenoidal magnetic field, nominally 8 T. The apparatus also houses a magnetic field shield for housing superconducting electronics, and several other fixed-frequency resonators for use in testing and commissioning various prototype quantum electronic devices sensitive at a range of axion masses in the range 2.0–40 μ eV c -2 . The apparatus as currently configured is intended as a test stand for electronics over the relatively wide frequency band attainable with TM 010 the cavity mode used for axion searches. We present performance data for the resonator, DF, and magnet, and plans for the first science run.

Physics - Physics of elementary particles and fiel

Leveraging FPGA Advantages for Quicker Data Processing for LBNF

The Long Baseline Neutrino Facility (LBNF) will deliver a 2.4 MW muon neutrino beam from Fermilab to the Deep Underground Neutrino Experiment (DUNE), requiring unprecedented precision in beamline alignment to achieve DUNE's neutrino oscillation measurement goals. Vertical misalignments of beamline components as small as 0.5 mm can contribute 6-7\% uncertainty in predicted neutrino flux, necessitating sub-0.1 mm alignment monitoring capabilities. The Horn Location Sensor (HLS) system employs frequency sweep interferometry (FSI) in a distributed hydrostatic leveling network to achieve the required precision under harsh radiation conditions up to 5000 kRad/year. Traditional FSI implementations suffer from laser sweep nonlinearities that degrade resolution and require computationally intensive post-processing corrections using gas reference cells. This work presents a real-time FPGA-based implementation of the HLS data acquisition and processing system using a sweep tracker interferometer for dynamic sweep linearization. The system utilizes a PYNQ-Z2 FPGA with programmable logic implementing parallel 16k-point FFT processing across four channels, synchronized by the sweep tracker signal to eliminate post-processing requirements. Spectral performance testing demonstrates significant improvements in peak sharpness compared to traditional fixed-frequency digitization. The FPGA implementation enables real-time displacement monitoring with processing speeds orders of magnitude faster than software-based approaches, essential for the operational requirements of LBNF's eventual distributed sensor network. This advancement in real-time FSI processing directly supports DUNE's precision neutrino physics program by providing the rapid feedback necessary for maintaining stringent beamline alignment tolerances during high-power beam operations.

Rossel, Jacob

Real-Time FPGA Implementation For Frequency Sweep Interferometry In The LBNF Complex

The Long Baseline Neutrino Facility (LBNF) will deliver a 2.4 MW muon neutrino beam from Fermilab to the Deep Underground Neutrino Experiment (DUNE), requiring unprecedented precision in beamline alignment to achieve DUNE's neutrino oscillation measurement goals. Vertical misalignments of beamline components as small as 0.5 mm can contribute 6-7\% uncertainty in predicted neutrino flux, necessitating sub-0.1 mm alignment monitoring capabilities. The Horn Location Sensor (HLS) system employs frequency sweep interferometry (FSI) in a distributed hydrostatic leveling network to achieve the required precision under harsh radiation conditions up to 5000 kRad/year. Traditional FSI implementations suffer from laser sweep nonlinearities that degrade resolution and require computationally intensive post-processing corrections using gas reference cells. This work presents a real-time FPGA-based implementation of the HLS data acquisition and processing system using a sweep tracker interferometer for dynamic sweep linearization. The system utilizes a PYNQ-Z2 FPGA with programmable logic implementing parallel 16k-point FFT processing across four channels, synchronized by the sweep tracker signal to eliminate post-processing requirements. Spectral performance testing demonstrates significant improvements in peak sharpness compared to traditional fixed-frequency digitization. The FPGA implementation enables real-time displacement monitoring with processing speeds orders of magnitude faster than software-based approaches, essential for the operational requirements of LBNF's eventual distributed sensor network. This advancement in real-time FSI processing directly supports DUNE's precision neutrino physics program by providing the rapid feedback necessary for maintaining stringent beamline alignment tolerances during high-power beam operations.

Rossel, A. Jacob [Fermilab; Unlisted]

Hydrodynamic Impact of a System with a Single Elastic Mode II : Comparison of Experimental Force and Response with Theory

Hydrodynamic impact tests were made on an elastic model approximating a two-mass spring system to determine experimentally the effects of structural flexibility on the hydrodynamic loads encountered during seaplane landing impacts and to correlate the results with theory. A flexible seaplane was represented by a two-mass spring system consisting of a rigid prismatic float connected to a rigid upper mass by an elastic structure. The model had a ratio of sprung mass to hull mass of 0.6 and a natural frequency of 3.0 cycles per second. The tests were conducted in smooth water at fixed trims and included both high and low flight-path angles and a range of velocity. Theoretical and experimental comparisons indicated that the theoretical results agreed well with the experimental results.

Miller, Robert W

A Study of Longitudinal Control Problems at Low and Negative Damping and Stability with Emphasis on Effects of Motion Cues

As part of a general investigation to determine the effects of simulator motions on pilot opinion and task performance over a wide range of vehicle longitudinal dynamics, a cooperative NASA-AMAL program was conducted on the centrifuge at Johnsville, Pennsylvania. The test parameters and measurements for this program duplicated those of earlier studies made at Ames Research Center with a variable-stability airplane and with a pitch-roll chair flight simulator. Particular emphasis was placed on the minimum basic damping and stability the pilots would accept and on the minimum dynamics they considered controllable in the event of stability-augmentation system failure. Results of the centrifuge-simulator program indicated that small positive damping was required by the pilots over most of the frequency range covered for configurations rated acceptable for emergency conditions only (e.g., failure of a pitch damper). It was shown that the pilot's tolerance for unstable dynamics was dependent primarily on the value of damping. For configurations rated acceptable for emergency operation only, the allowable instability and damping corresponded to a divergence time to double amplitude of about 1 second. Comparisons were made of centrifuge, pitch-chair and fixed-cockpit simulator tests with flight tests. Pilot ratings indicated that the effects of incomplete or spurious motion cues provided by these three modes of simulation were important only for high-frequency, lightly damped dynamics or unstable, moderately damped dynamics. The pitch- chair simulation, which provided accurate angular-acceleration cues to the pilot, compared most favorably with flight. For the centrifuge simulation, which furnished accurate normal accelerations but spurious pitching and longitudinal accelerations, there was a deterioration of pilots' opinion relative to flight results. Results of simulator studies with an analog pilot replacing the human pilot illustrated the adaptive capability of human pilots in coping with the wide range of vehicle dynamics and the control problems covered in this study. It was shown that pilot-response characteristics, deduced by the analog-pilot method, could be related to pilot opinion. Possible application of these results for predicting flight-control problems was illustrated by means of an example control-problem analysis. The results of a brief evaluation of a pencil-type side-arm controller in the centrifuge showed a considerable improvement in the pilots' ability to cope with high-frequency, low-damping dynamics, compared to results obtained with the center stick. This improvement with the pencil controller was attributed primarily to a marked reduction in the adverse effects of large and exaggerated pitching and longitudinal accelerations on pilot control precision.

Sadoff, Melvin

IOTA experiment for proton pulse compression at extreme space-charge

The longitudinal compression of intense proton bunches with strong space-charge force is an essential component of a proton driver for a muon collider. We propose a proton bunch compression experiment at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab to explore optimal radio frequency (RF) cavity and lattice configurations. IOTA is a compact fixed-energy storage ring dedicated to beam physics R&D that can circulate a 2.5-MeV proton beam with extreme space-charge. Using ImpactX and its 3D space-charge solver, simulations indicate that bunch length can be rapidly reduced by a factor of at least two, without appreciable degradation in transverse beam quality, even under strong space-charge conditions. However, longitudinal defocusing presents a large effect in short-pulsed proton beams, and the optimization of bunch compression under such conditions is discussed.

Simons, Benjamin [Northern Illinois U.; Fermilab]

IOTA Experiment for Proton Pulse Compression at Extreme Space-Charge

The longitudinal compression of high-intensity, space-charge-dominated proton bunches is a critical requirement for future proton-driven muon colliders. We propose a proton bunch compression experiment at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab to investigate optimal radio-frequency (RF) cavity parameters and lattice configurations. IOTA is a compact, fixed-energy storage ring dedicated to beam physics Research and Development and capable of circulating a 2.5 MeV proton beam under extreme space-charge conditions. Using the ImpactX code with its 3D space-charge solver, simulations indicate that the bunch length can be rapidly reduced by at least a factor of two without appreciable degradation of transverse beam quality--even in the strong space-charge regime. However, longitudinal defocusing due to the space-charge remains a significant challenge in short-pulsed intense proton bunches, and the optimization of compression under these conditions is discussed.

Simons, B. D. [Northern Illinois U.]

Phase Picking Beyond Local Distances: Where Waveform Filtering Still Matters for Deep Learning Models

Waveform filtering is a standard step in traditional seismic phase picking but often receives little attention in deep learning workflows, where models are typically trained on raw or minimally processed waveforms. Although this strategy performs well for local events, we show that performance can degrade substantially at regional distances. To address this limitation, we introduce two ways to incorporate multiband-filtered waveforms into deep learning phase pickers. The stacking approach concatenates filtered inputs along the channel dimension, while the branching approach processes each frequency band through a dedicated network branch before feature fusion. Both approaches can substantially improve performance across epicentral distances of 0° to 20°, but their effectiveness depends strongly on the selected frequency bands. Tests with multiple filter banks show that filter-bank design should be treated as part of model optimization rather than as a fixed preprocessing choice. Grad-CAM analysis of the branching model indicates that band importance varies among waveform samples and across training realizations, with only a weak overall preference for the 0.25 to 0.5 Hz band. These results show that no single filter band is consistently optimal and demonstrate that explicit feature engineering remains valuable for robust deep learning-based seismic phase picking.

58 GEOSCIENCES

Dimensionally Aligned Signal Projection Algorithms Library

Dimensionally aligned signal projection (DASP) algorithms are used to analyze fast Fourier transforms (FFTs) and generate visualizations that help focus on the harmonics for specific signals. At a high level, these algorithms extract the FFT segments around each harmonic frequency center, and then align them in equally sized arrays ordered by increasing distance from the base frequency. This allows for a focused view of the harmonic frequencies, which, among other use cases, can enable machine learning algorithms to more easily identify salient patterns. This work seeks to provide an effective open-source implementation of the DASP algorithms proposed by Vann et al. (2018) as well as functionality to help explore and test how these algorithms work with an interactive dashboard and signal-generation tool. The DASP library is implemented in Python and contains four types of algorithms for implementing these feature engineering techniques: fixed harmonically aligned signal projection (HASP), decimating HASP, interpolating HASP, and frequency aligned signal projection (FASP). Each algorithm returns a numerical array, which can be visualized as an image. The HASP algorithms are variations of the algorithms originally presented by Vann et al. (2018). For consistency, FASP, which is the terminology used for the short-time Fourier transform (STFT), has been implemented as part of the library to provide a similar interface to the STFT of the raw signal. Additionally, the library contains an algorithm to generate artificial signals with basic customizations such as the base frequency, sample rate, duration, number of harmonics, noise, and number of signals. Finally, the library provides multiple interactive visualizations, each of which is implemented using IPyWidgets and works in a Jupyter environment. A dashboard-style visualization is provided, which contains some common signal-processing visual components (signal, FFT, spectogram) updating in unison with the HASP functions (see Figure 1 below). Separate from the dashboard, an independent visualization is provided for each of the DASP algorithms as well as for the artifical signal generator. These visualizations are included in the library to aid in developing an intuitive understanding how the algorithms are affected by different input signals and parameter selections.

harmonics

Real-Time Wave Energy Converter Control Using Instantaneous Frequency

Wave Energy Converters (WECs) rely on effective Power Take-Off (PTO) control strategies to maximize energy absorption under dynamic sea conditions. Traditional hydrodynamic modeling techniques may require computationally intensive convolution calculations, making real-time control implementation challenging. This paper presents an alternative approach by leveraging instantaneous frequency estimation to dynamically adjust PTO damping in response to varying wave frequencies. Two real-time frequency estimation methods are explored: the Hilbert Transform (HT) and Phase-Locked Loop (PLL). The Hilbert Transform method provides accurate frequency tracking but introduces a delayed response due to its dependence on causal data. Conversely, the PLL approach demonstrates strong potential in frequency tracking but requires careful gain tuning, particularly in complex sea states. Comparative evaluations across multiple test cases—including sinusoidal variations, amplitude steps, frequency step changes, and real-world JONSWAP spectrum waves—highlight the strengths and limitations of each method. The two different PTO control techniques across the various frequency estimation methods were tested under real-sea states using a state-space model of a point-absorbing Wave Energy Converter. The Capture Width Ratio (CWR) is used as a performance metric, with results showing that the HT achieves a 10.6% improvement, while the PLL estimation yields a 0.9% improvement relative to the fixed parameter control baseline. These results highlight the effectiveness of real-time frequency estimation in improving energy absorption compared to static control parameters.

WEC control

VHF ranging and position fixing experiment using ATS satellites: Executive summary of final report on phases 1 and 2, 25 November - 1 May 1971

The VHF transponders of the ATS-1 and ATS-3 geostationary satellites were used in ranging and position fixing experiments. An interrogation signal was transmitted from a ground terminal to ATS-3, which relayed it to the vehicle transponders. The vehicle that was addressed repeated the signal and its response was relayed back through both satellites to the ground terminal, where propagation times were measured; lines-of-position and fixes were computed. The 0.43 second tone-code ranging signal contained a single audio tone frequency. Ambiguity was resolved and user craft identified by a simple digital code. Seven vehicles were used in the test: three aircraft, two ships, an oceanographic buoy, and a truck. Ionospheric and multipath effects were studied. It is concluded that a VHF system could have an accuracy of + or - one nautical mile for ships and aircraft if calibration transponders are used to monitor the ionosphere.

Source record

Pareto-optimal target definition for multi-axis random vibration testing

In random vibration testing with multiple control channels, existing control laws require specification of a complete spectral density matrix at each control frequency. Spectral density matrices include autospectral densities on the diagonal and cross-spectral densities on the off-diagonal. In practice, the off-diagonal terms are often unknown, and recent vibration testing research has focused on fixing the diagonal and specifying the off-diagonal to minimize the required control energy, subject to a constraint that the target matrix is positive semidefinite. This paper shows that, even with a fixed diagonal, off-diagonal terms strongly affect control residuals. This overlooked effect occurs in both square and rectangular systems. By jointly considering input energy and control residuals, open-loop inputs are derived directly from the diagonal without specifying the off-diagonal terms. Vibration targets that can be used in closed-loop control are then derived using the optimal inputs, with positive semidefinite constraints applied during the derivation. The result is a set of Pareto-optimal control solutions. For each solution in the set, any other possible solution produces greater control error, greater input energy, or both. A balanced solution is selected automatically, though others can be chosen based on test needs. Simulations and experiments show that the proposed method outperforms state-of-the-art energy-minimizing approaches, achieving significant reductions in both control error and input energy.

Autospectral density

VHF Ranging and Position Fixing Experiment Using ATS Satellites: Final Report on Phases 1 and 2, 25 November 1968 - 1 May 1971

The testing program with the ATS-1 and ATS-3 spacecraft showed that geostationary satellites can provide superior communications and position surveillance for mobile craft. Inexpensive modifications to conventional mobile communications equipment aboard the craft can provide reliable, high quality voice and digital communications with distant ground stations and other vehicles, and automatic surveillance of the positions of all the craft by a ground facility. The tests also demonstrated the location and automatic readout of remote data collection platforms. Frequency modulation signals with the narrow audio and radio frequency bandwidths of terrestrial mobile radio communications were relayed through the VHF transponders of the geostationary satellites. The voice and digital communications were far superior in reliability and quality to long-distance mobile communications by other means. It was shown that one satellite can provide nearly uniform high quality performance over approximately one-third of the earth's surface. Position fixes by range measurement from the two satellites were accurate to approximately one nautical mile, except near the equator and the poles.

Source record

ATS ranging and position fixing experiment, phase 3

The experiments to test the concept of position location by range measurements from pairs of satellites in the L-band using ATS-5 are reported. Results of the ranging experiments confirmed that ranging resolution measured in tens or hundreds of feet may be achieved at VHF and L-band within the radio frequency bandwidths used for communications with simple, inexpensive, automatic equipment.

Anderson, R. E.

Analysis of Polarized Dust Emission Using Data from the First Flight of SPIDER

Using data from the first flight of Spider and from the Planck High Frequency Instrument, we probe the properties of polarized emission from interstellar dust in the Spider observing region. Component-separation algorithms operating in both the spatial and harmonic domains are applied to probe their consistency and to quantify modeling errors associated with their assumptions. Analyses of diffuse Galactic dust emission spanning the full Spider region demonstrate (i) a spectral energy distribution that is broadly consistent with a modified-blackbody (MBB) model with a spectral index of β d = 1.45 ± 0.05 (1.47 ± 0.06) for E (B)-mode polarization, slightly lower than that reported by Planck for the full sky; (ii) an angular power spectrum broadly consistent with a power law; and (iii) no significant detection of line-of-sight polarization decorrelation. Tests of several modeling uncertainties find only a modest impact (~10% in σ r ) on Spider's sensitivity to the cosmological tensor-to-scalar ratio. The size of the Spider region further allows for a statistically meaningful analysis of the variation in foreground properties within it. Assuming a fixed dust temperature T d = 19.6 K, an analysis of two independent subregions of that field results in inferred values of β d = 1.52 ± 0.06 and β d = 1.09 ± 0.09, which are inconsistent at the 3.9σ level. Furthermore, a joint analysis of Spider and Planck 217 and 353 GHz data within one subregion is inconsistent with a simple MBB at more than 3σ, assuming a common morphology of polarized dust emission over the full range of frequencies. This evidence of variation may inform the component-separation approaches of future cosmic microwave background polarization experiments.

79 ASTRONOMY AND ASTROPHYSICS