Temperatures of lunar impact flashes: mass and size distribution of small impactors hitting the Moon
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The 45th Weather Squadron (45 WS) asked the Applied Meteorology Unit (AMU) to review the 30-year-old, lightning stand-off distances of 5 nautical miles (nmi) for applicability to today's operations. This was based on the realization that previous lightning strike distance studies did not match how 45 WS issues lightning warnings (Roeder, 2008). The previous lightning distance studies were from the point of origin of the lightning or the average starting location that would tend to be in the core of the thunderstorm. However, the 45 WS issues lightning warnings based on the edge of a preexisting lightning area. Before beginning the AMU project, it took several years to develop a method to calculate a distance distribution beyond a preexisting area (Roeder, 2015). The AMU pulled Lightning Detection and Ranging (LDAR) sensor data from 1/1/2013 to 12/31/2013. This dataset consisted of 37 million individual source data points from the LDAR sensors. Only sources within 50 km north, south, east or west of the LDAR grid center were included in the dataset. This limited the use of LDAR data to that with the greatest accuracy of source detection and increased data processing. Points were grouped into flashes based on spatial and temporal criteria. Based on the sensitivity analysis the AMU performed on the flash clustering algorithm, a time value of 0.3 seconds was found to model flashes adequately. Distance parameters were tested from 1,500 to 7,500 meters (m) in 500 m increments. Distance parameters of both 3,000 m and 4,000 m produced results in the plotting tool that were most representative of the physical behavior of lightning. Thus statistics were gathered for the most representative of these spatial and temporal criteria on the flash size and the polygon expansion distance in order to find the correct data distributions. The best fit curves for the LDAR polygon expansion frequency vs. distances for both the 3 kilometer (km) and 4 km distance threshold values were exponential decay functions and had R2 values of > 0.998, indicating good model fits. The equations of the best fit curves were then used to calculate a desired safety radius of 4 nmi for either 3 km or 4 km distance threshold criteria. The AMU analysis concludes the safe reduction of the 5 nmi lightning warning circles to 4 nmi should improve the operational impact by 36% if based on distance from the center of the property area being protected. If based on the edge of the property being protected, then the reduction is 4.5 nmi to 4 nmi and the operational impact is decreased by 21%. For the 6 nmi lightning warning circles, the recommended 4 nmi stand-off distance will result in a safe reduction of operational impact of 31% if based on the center of the area being protected, or 16% if based on the edge of the property.
During the Flash process, the cross section of a plain-carbon or a low-alloy steel is austenitized through rapid heating and transformed on rapid cooling to a predominantly martensite + bainite structure with small amounts of retained austenite. Unlike conventional heat treating, homogeneity is intentionally avoided during Flash processing of steels. The Flash process assembly consists of a pair of rolls that transfer the steel sheets through the heating and cooling stage of the thermal cycle. The initial microstructure of the steel consists of ferrite (body-centered cubic iron) + carbide ((Fe,X)mCn) mixture. The heating rate through the peak temperature is a function of temperature and reaches a peak of about 300-400°C/s and the cooling rate has a maximum value of 3,000-4,000°C/s. The on-heating phase transformations include carbide dissolution, austenite (face-centered cubic iron) nucleation and growth, and diffusion of carbon and other substitutional elements in the steel. The on-cooling phase transformations include formation of martensite (body-centered tetragonal phase containing supersaturated solute) and bainite (ferrite plates with or without fine carbides). In this project, the focus is on Fe-C-Cr steels that are currently Flash processed for armor applications. The modeling effort proposed here will help optimize the Flash thermal cycle for these low alloy steels to achieve the target performance, which is an ongoing effort at SFP Works. A significant feature of Flash processed Fe-C-Cr steels is the presence of scatter in the through-thickness in the sheet. The variability in hardness results from a variability in the bainite + martensite microstructure that is sensitive to the local chemical concentration of C and Cr. Such a chemical inhomogeneity is intentionally obtained in the Flash process. Although such a microstructural gradient is presumably responsible for the exceptional properties of the Flash processed steel, it is very important to quantify the gradients as a function of Flash variabilities in processing parameters and the input microstructure. Understanding the mechanistic pathway that leads to microstructural gradients could be ground-breaking and instrumental for achieving better process control and optimized microstructural state to meet application-specific strength-ductility requirements. Since the final microstructure depends on setting up precise solute concentration gradients through a rapid heating process, and transforming these regions into various phases, it is important to understand how small changes in steel chemistry, input microstructure (carbide size and distribution), and process variables (Flash thermal cycle) will impact the solute concentration gradients.
The vertical location of the lightning superbolts seen on the Voyager images of Jupiter has been determined using a comparison between the measured spot sizes for single flashes with the intensity distributions calculated from various assumptions about the altitude of the flash. A Monte Carlo model was used to describe the light scattering in the clouds, aerosols, and gases of the Jupiter atmosphere. Best agreement between the measurements and the model predictions was obtained when the lightning activity was assumed to occur in a lower cloud centered at the 5-bar pressure level, whereas the width predicted for lightning in the ammonia cloud was much smaller than the measured widths. The results imply that the lightning observed by the Voyager must be in a cloud much deeper than the ammonia cloud. The lower cloud is expected to be composed of water or a mixture of water and ammonium hydrosulfide.
For decades, lightning has been used with some success as an indicator of tropical cyclone (TC) intensity change. An increase in inner-core lightning is usually associated with TC intensification, but this is not always the case. Significant lightning outbreaks have been observed in weakening storms, and hurricanes can rapidly intensify in the total absence of inner-core lightning. These conflicting results arise because lightning production depends on convective and microphysical characteristics that can arise during both intensification and weakening phases in TCs. Recent work using flash size and energy metrics provided by the Geostationary Lightning Mapper (GLM) aboard the GOES-R series of satellites shows some promise in distinguishing between lightning outbreaks that correspond to intensification and those that correspond to weakening. If a hurricane is rapidly intensifying in the presence of inner-core lightning, the size and optical energy of the flashes generally increases as intensification proceeds. It is hypothesized that this relationship is governed by changes in the TC-scale circulation that produce enhanced upper-level outflow and large, strongly helical convective updrafts in the inner core. These changes increase the quantity and spatial extent of charged upper-level ice, which allows large intracloud flashes to occur when electric field breakdown occurs. This presentation will present objective diagnostics of convective asymmetry using azimuthal wavenumber decomposition of GOES-R Advanced Baseline Imager brightness temperatures. The degree of symmetry will be related to GLM flash characteristics to better understand how changes in the symmetry of TC inner-core convection relates to flash rate, size, and energy. It will also show how the evolution of inner-core asymmetries relates to the spatial distribution and characteristics of lightning flashes in the inner core.
Research projects involving oscillatory combustion and fuel vaporization are reported. Comparisons of experimental and theoretical droplet vaporization histories under ambient conditions such that the droplet may approach its thermodynamic critical point are presented. Experimental data on instantaneous heat transfer from a gas to a solid surface under conditions of oscillatory pressure with comparisons to an unsteady one-dimensional model are analyzed. Droplet size and velocity distribution in a spray as obtained by use of a double flash fluorescent method were investigated.
Previous work using land-based lightning detection networks and lightning imagers in low Earth orbit has established that lighting is a useful predictor of TC intensification. Increases in the number of lightning flashes in both the inner core and outer rainbands of hurricanes are linked to hurricane intensification. Sometimes, however, lightning outbreaks can occur in storms that weaken during or after the outbreak. Environmental conditions such as vertical wind shear and land interaction or inner-core structural changes such as secondary eyewall formation can account for some of this discrepancy. Hurricane Dorian (2019), however, exhibited a distinct inner-core lightning outbreak in a low-shear environment with minimal land interaction. The lightning flashes during this outbreak were located on the inner edge of the eyewall, which is not the expected location of enhanced convection during secondary eyewall formation. Regardless, Dorian weakened during and after this lightning outbreak. This presentation will analyze Dorian’s lightning evolution using data from the Geostationary Lightning Mapper (GLM) aboard the GOES-16 satellite. GLM provides continuous observations of not only the number and polarity of lightning flashes, but also the size and optical energy of the flashes. Here we show marked differences in the distributions of average flash area and total optical energy between the two most pronounced lightning outbreaks in Dorian’s lifetime: one while the storm was rapidly intensifying and another while the storm began to weaken. During intensification, lightning flashes were fewer but larger and more energetic, whereas during weakening, lightning flashes were much more numerous, but were smaller and less energetic. We present evidence that barotropic mixing between the eye and eyewall could have contributed to both the increase in inner-core lightning and the weakening of Dorian’s storm-scale maximum wind speed. These results suggest that average flash area and total optical energy could help to distinguish between lightning outbreaks that correspond to intensification and outbreaks that correspond to weakening.
In the present study we utilized Friction Extrusion (FE) a solid phase processing technique to produce fully consolidated dense 5 mm rods of AA7075 alloy. The combination of large shear stresses and temperatures at the tool-billet interface during the FE process resulted in the formation of dynamically recrystallized ~2.0 μm equiaxed grains and fine uniformly distributed stable η (MgZn 2 ) precipitates ~25–100 nm in size. Formation of such a microstructure resulted in lower solutionizing temperature and times (flash annealing) as compared to the conventionally extruded counterparts. Here we demonstrate for the first time that the solutionizing times for the T6 heat treatment of AA7075 can be reduced by three times using this FE process. In addition to being an energy efficient process, FE also serves to improve the performance of AA7075 alloys by retaining their strength while enhancing the ductility of the material. The tensile data for samples that were flash annealed and artificially aged after FE processing showed exceptional increase in ultimate tensile strength by over 19% and yield strength by over 59%, compared with an as-FE-processed sample.
Multiwavelength observations of supernova remnant (SNR) 1987A show that its morphology and luminosity are rapidly changing at X-ray, optical, infrared, and radio wavelengths as the blast wave from the explosion expands into the circumstellar equatorial ring, produced by mass loss from the progenitor star. The observed infrared (IR) radiation arises from the interaction of dust grains that formed in mass outflow with the soft X-ray emitting plasma component of the shocked gas. Spitzer IRS spectra at 5 - 30 microns taken on day 6190 since the explosion show that the emission arises from approx. 1.1 x 10(exp -6) solar mass of silicate grains radiating at a temperature of approx. 180+/-(15-20) K. Subsequent observations on day 7137 show that the IR flux had increased by a factor of 2 while maintaining an almost identical spectral shape. The observed IR-to-X-ray flux ratio (IRX) is consistent with that of a dusty plasma with standard LMC dust abundances. This flux ratio has decreased by a factor of approx. 2 between days 6190 and 7137, providing the first direct observation of the ongoing destruction of dust in an expanding SN blast wave on dynamic time scales. Detailed models consistent with the observed dust temperature, the ionization fluence of the soft X-ray emission component, and the evolution of IRX suggest that the radiating si1icate grains are immersed in a 3.5 x 10(exp 6) K plasma with a density of (0.3 - 1) x 10(exp 4)/cu cm, and have a size distribution that is confined to a narrow range of radii between 0.02 and 0.2 microns. Smaller grains may have been evaporated by the initial UV flash from the supernova.
There is no definitive knowledge of which of several concurrent processes ultimately results in unstable combustion within liquid rocket chambers employing shear coaxial injectors. Possible explanations are a detrimental change in the atomization characteristics due to a decrease in the gas-to-liquid velocity ratio, a change in the gas side injector pressure drop allowing acoustic coupling to the propellant feed system or the disappearance of a stabilizing recirculation region at the base of the LOX post. The aim of this research effort is to investigate these proposed mechanisms under conditions comparable to actual engine operation. Spray characterization was accomplished with flash photography and planar laser imaging to examine the overall spray morphology and liquid jet breakup processes and with a PDPA to quantify the spatial distribution of droplet size and mean axial velocity. A simplified stability model based on the Rayleigh criterion was constructed for the flow dynamics occurring within the chamber and injector to evaluate the potential coupling between the chamber and injector acoustic modes and was supported by high frequency measurements of chamber and injector pressure oscillations. To examine recirculation within the LOX post recess, velocity measurements were performed in the recess region by means of LDV. Present experiments were performed under noncombusting conditions using LOX/GH2 stimulants at pressures up to 4 MPa.
The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using two electron Linear Induction Accelerators (LIA’s). Understanding fundamental properties of the electron beams is essential to optimizing spot size and dose for radiography. This work describes distribution measurements of a single-kicked electron beam (16.5MeV, 1.7kA, 60ns) at a location downstream at imaging station C on DARHT Axis 2. The beam at station C is focused by the S4 solenoid located upstream. The beam distribution is measured by imaging optical transition radiation (OTR) from electrons striking a 51-µm thick titanium foil. This data and analysis were originally published by Ekdahl. The results here are a re-analysis of the asymmetric halo emittance contribution as compared to the emittance resulting from the FWHM of the distribution. This is accomplished using xtr2 fits to the data which include non-linear magnetic field effects in S4. Also examined are the calculated S4 spherical aberration contributions to the emittance using xtr.
Polymorphs of enstatite are common phases in many meteorites. They contain clues on their formation and the thermal evolution of their host rock which includes shock metamorphism. Rare, micron-sized, CLEN whiskers and thin platelets in chondritic porous micrometeorites were interpreted as solar nebula condensates that remained unaffected during atmospheric entry flash-heating. This CLEN formed by protoenstatite (PEN) inversion whereby the surface energy of the micron-sized PEN crystals aided the OREN-CLEN transformation or by metastable growth. Ca-poor, Mg,Fe-pyroxene with unequilibrated, intraparticle, Mg/(Mg+Fe) distributions occur in most chondritic micrometeorites. These distributions are a parent body signature that survived dynamic pyrometamorphism because the duration of the thermal spike during atmospheric entry is too short but this conclusion does not consider the ultrafine grain size of micrometeorites. The maximum temperature and duration of the heating event will depend on the kinetic energy and entry angle of the incoming micrometeorite. But lacking detailed petrological data for an individual particle, its thermal profile during atmospheric entry can not be deduced from its mass alone as a function of entry angle. In order to constrain dynamic pyrometamorphism in unmelted micrometeorites, I determined the petrological composition and silicate mineralogy in non-chondritic micrometeorites L2005T13, L2005E40, and L2006A28.
A Large Area Pulsed Solar Simulator (LAPSS) has been installed at JPL. It is primarily intended to be used to illuminate and measure the electrical performance of photovoltaic devices. The simulator, originally manufactured by Spectrolab, Sylmar, California, occupies an area measuring about 3 meters wide by 12 meters long. The data acquisition and data processing subsystems have been modernized. Tests on the LAPSS performance resulted in better than +/- 2 percent uniformity of irradiance at the test plane and better than +/- 0.3 percent measurement repeatability after warm-up. Glass absorption filters are used to reduce the level of ultraviolet light emitted from the xenon flash lamps. This provides a close match to standard airmass zero and airmass 1.5 spectral irradiance distributions. The 2 millisecond light pulse prevents heating of the device under test, resulting in more reliable temperature measurements. Overall, excellent electrical performance measurements have been made of many different types and sizes of photovoltaic devices.
Here, this work investigated the behaviors of single-component and multi-component sprays under different flash boiling intensities. Isooctane, hexane, ethanol, isooctane-hexane, and isooctane-ethanol mixtures were used as test fuels. The pressure ratio of the ambient pressure over saturation pressure (R p ) was used as the indicator of the superheated degree. Macroscopic characteristics of the sprays under 10 different R p (1.1 to 0.14) were investigated using Diffused Backlight Imaging (DBI). Droplet size, which revealed the spray microscopic characteristics, was also investigated using Phase Doppler Anemometry (PDA). The results showed that ambient pressure reduction led to higher flash boiling intensity, significant spray morphology changes, and smaller droplet size, regardless of the fuel type and blend ratios. Spray collapse was observed for all sprays once R p dropped below 0.3. Spray collapse dramatically increased the liquid penetration length, expanded the near-field spray angle, and reduced the far-field angle for sprays with all the fuels. Fuel properties, such as the latent heat of vaporization, had significant impacts on droplet size distributions, thus altering the liquid penetration length and spray angles. Under similar R p , sprays with high ethanol content generally had larger droplet sizes compared with other fuel sprays due to the high latent heat of vaporization. The larger droplets caused the high ethanol content sprays to be more resistant to the plume trajectory change, resulting in a smaller far-field spray angle variations with changing R p . At R p of 0.28, sprays with the similar latent heat of vaporization have similar droplet sizes, and droplet sizes at different radial locations were also similar to each other.
Multi-sensor measurements of total lightning (in-cloud plus cloud-to-ground) from the Lightning Imaging Sensor (LIS) aboard the TRMM satellite has been combined with passive microwave ice scattering and precipitation radar reflectivity profile information previously cataloged for precipitation features observed by TRMM. These precipitation features are defined by their surface rainfall or ice scattering signatures, with horizontal scales approx. 100 - 10000 sq km. Additionally, convective scale (approx. 100 sq km) storms are defined by the lightning data. Over the U.S. the national cloud-to-ground lightning observations are used to also determine the ratio of in-cloud to cloud-to-ground lightning, where it is hypothesized these ratios are related to the vertical profile of reflectivity and concentration of precipitation-sized ice. Combining the LIS, TRMM Microwave Imager (TMI), and Precipitation Radar (PR) for these storms allows investigation of the convective structures and convective regimes leading to observed lightning, scattering, and reflectivity signatures. Application of this approach to a global, multi-year data set (1998-2000) furthers our understanding of convective processes in different climatological regimes. The figure shows the distribution of high flash rate storms.
This study presents a comprehensive examination of the spectrum of storm types and their attributes worldwide (between 35N and 35S latitude), and as a function of season, location, and convective regime using the observed lightning, microwave scattering, and reflectivity signatures from NASA's Tropical Rainfall Measuring Mission (TRMM) low-Earth orbiting observatory. A global, multi-year data set (1998-2000) indicates that the deepest thunderstorms (having reflectivity in excess of 50 dBZ at 9 km altitude) occur in all the sub-tropical continents and occasionally over the open ocean, but are most common over the Americas. The most intense storms have the greatest lightning rates, lowest brightness temperatures and greatest depth of reflectivity- all indicative of strong updrafts and a well-developed volume of precipitation-sized ice particles. Mesoscale convective systems occurring within or in association with forcing from the sub-tropical continents are the most prolific lightning producers. The greatest flash rate to date of 993 flashes per minute was observed by NASA's Lightning Imaging Sensor on May 6, 1999 during an overpass of a pre-frontal squall line extending from Tennessee to Louisiana. The global distribution and frequency of thunderstorms, and the most recent summary of the extreme storms observed from space, in particular, will be discussed in greater detail.
Here, this study demonstrated the reactive flash sintering (RFS) for two powder mixtures: TiN-ZrN (both conducting) and AlN-TiN (TiN conducting but AlN insulating), targeting ternary metal nitrides (TMN) of Ti 0.5 Zr 0.5 N and Ti 0.5 Al 0.5 N, respectively. A constant volage and pressure (e.g., 8 V DC, ∼15 MPa) at room temperature triggered the flash (current density up to 27 A/mm 2 ) without pre-heating, and the entire RFS process finished in a few minutes. For TiZrN, the flash was instantaneous whereas for TiAlN, there was a long incubation before the flash followed by a quick and dramatic flash. Both conventional ex situ XRD and in situ synchrotron study had been carried out. They showed a uniform Ti 0.57 Zr 0.43 N solution formed in RFS and persisted upon cooling, while (Ti, Al) N solid solution formed at high temperature was not stable and likely went through a very quick phase separation in the cooling process. The final products from RFS had been characterized using SEM/EDS for microstructure. Both TiZrN and TiAlN were dense. Distribution of Ti, Zr, and N was uniform for TiZrN; for TiAlN, Ti and N distribution was uniform, while association of Al with oxygen was observed. TGA-DSC revealed the onset oxidation temperature for TiZrN was comparable to TiN and ZrN, while it was higher by ∼200 °C for TiAlN, likely due to the formation of Al 2 O 3 . In terms of mechanical properties such as hardness or fracture toughness, forming a single-phase solid solution (like TiZrN) does not offer obvious benefits. while large grain size from RFS seemed to be unfavorable. Future optimization of RFS condition and in-depth study by both experiments and simulation are needed to fully understand the composition-processing-structure-property relationships for such TMN from the reactive flash sintering process.
Data centers have grown in physical size and their electrical power consumption has grown to levels of several 100kW and approaching 1 GW in large installations. The low voltage electrical distribution inside of Data Centers consists of several conversion stages and a lot of wiring to bring the power from medium voltage (MV) levels outside of the building to the low voltage levels that the servers and racks require. Energy losses during distribution and conversion and high incident arc flash energy levels at the point of use are significant. The electrical distribution system is complex and costly.