Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flex Harness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Analysis of a Dynamic Flexed Flat Cable Harness

A dynamic flex test was performed on a spacecraft instrument harness composed of multiple individual flex cables, with each flex cable containing multiple copper traces. The purpose of the test was to demonstrate the capability of the harness to survive the number of expected flex cycles during the planned mission with appropriate margin. However, during testing, increased trace resistances and open circuits were observed beginning at approximately 10% of the total number of planned flex cycles. This paper discusses the various proximate causes that contributed to increased and open resistance in the flex cables and the subsequent redesign, manufacturing, reliability, and quality-related changes that were instituted. An analysis process, including failure analysis, non-destructive evaluation, digital imaging correlation, and parametric modeling, will also be discussed. The paper will cover the development of a robust dynamic flex harness design and include recommendations to extend flex harness life; make changes to the flex harness life test; and improve flex cable manufacturing, quality, and reliability.

Flexible PCB↗

Analysis of a Dynamic Flexed Flat Cable Harness

A dynamic flex test was performed on a spacecraft instrument harness composed of multiple individual flex cables, with each flex cable containing multiple copper traces. The purpose of the test was to demonstrate the capability of the harness to survive the number of expected flex cycles during the planned mission with appropriate margin. However, during testing, increased trace resistances and open circuits were observed beginning at approximately 10% of the total number of planned flex cycles. This paper discusses the various proximate causes that contributed to increased and open resistance in the flex cables and the subsequent redesign, manufacturing, reliability, and quality-related changes that were instituted. An analysis process, including failure analysis, non-destructive evaluation, digital imaging correlation, and parametric modeling, will also be discussed. The paper will cover the development of a robust dynamic flex harness design and include recommendations to extend flex harness life; make changes to the flex harness life test; and improve flex cable manufacturing, quality, and reliability.

Flexible PCB↗

Mars Science Laboratory Drill

The Drill for the Mars Science Laboratory mission is a rotary-percussive sample acquisition device with an emphasis on toughness and robustness to handle the harsh environment on Mars. The unique challenges associated with autonomous drilling from a mobile robot are addressed. A highly compressed development schedule dictated a modular design architecture that satisfies the functional and load requirements while allowing independent development and testing of the Drill subassemblies. The Drill consists of four actuated mechanisms: a spindle that rotates the bit, a chuck that releases and engages bits, a novel voice-coil-based percussion mechanism that hammers the bit, and a linear translation mechanism. The Drill has three passive mechanisms: a replaceable bit assembly that acquires and collects sample, a contact sensor / stabilizer mechanism, and, lastly a flex harness service loop. This paper describes the various mechanisms that makeup the Drill and discusses the solutions to their unique design and development challenges.

Okon, Avi B.↗

Mars Science Laboratory Drill

This drill (see Figure 1) is the primary sample acquisition element of the Mars Science Laboratory (MSL) that collects powdered samples from various types of rock (from clays to massive basalts) at depths up to 50 mm below the surface. A rotary-percussive sample acquisition device was developed with an emphasis on toughness and robustness to handle the harsh environment on Mars. It is the first rover-based sample acquisition device to be flight-qualified (see Figure 2). This drill features an autonomous tool change-out on a mobile robot, and novel voice-coil-based percussion. The drill comprises seven subelements. Starting at the end of the drill, there is a bit assembly that cuts the rock and collects the sample. Supporting the bit is a subassembly comprising a chuck mechanism to engage and release the new and worn bits, respectively, and a spindle mechanism to rotate the bit. Just aft of that is a percussion mechanism, which generates hammer blows to break the rock and create the dynamic environment used to flow the powdered sample. These components are mounted to a translation mechanism, which provides linear motion and senses weight-on-bit with a force sensor. There is a passive-contact sensor/stabilizer mechanism that secures the drill fs position on the rock surface, and flex harness management hardware to provide the power and signals to the translating components. The drill housing serves as the primary structure of the turret, to which the additional tools and instruments are attached. The drill bit assembly (DBA) is a passive device that is rotated and hammered in order to cut rock (i.e. science targets) and collect the cuttings (powder) in a sample chamber until ready for transfer to the CHIMRA (Collection and Handling for Interior Martian Rock Analysis). The DBA consists of a 5/8-in. (.1.6- cm) commercial hammer drill bit whose shank has been turned down and machined with deep flutes designed for aggressive cutting removal. Surrounding the shank of the bit is a thick-walled maraging steel collection tube allowing the powdered sample to be augured up the hole into the sample chamber. For robustness, the wall thickness of the DBA was maximized while still ensuring effective sample collection. There are four recesses in the bit tube that are used to retain the fresh bits in their bit box. The rotating bit is supported by a back-to-back duplex bearing pair within a housing that is connected to the outer DBA housing by two titanium diaphragms. The only bearings on the drill in the sample flow are protected by a spring-energized seal, and an integrated shield that diverts the ingested powdered sample from the moving interface. The DBA diaphragms provide radial constraint of the rotating bit and form the sample chambers. Between the diaphragms there is a sample exit tube from which the sample is transferred to the CHIMRA. To ensure that the entire collected sample is retained, no matter the orientation of the drill with respect to gravity during sampling, the pass-through from the forward to the aft chamber resides opposite to the exit tube.

Okon, Avi B.↗

Thin Film Technology Development for the Powersphere

The Aerospace Corporation, NASA Glenn Research Center, Lockheed-Martin, and ILC Dover over the past two years have been engaged in developing a Multifunctional Inflatable Structure for the Powersphere Concept under contract with NASA (NAS3-01115). The Powersphere concept consists of a relatively large spherical solar array, which would be deployed from a microsatellite. The Powersphere structure and the deployment method was patented by the Aerospace Corporation (U.S. Patent Numbers 6,284,966 B 1 and 6,3 18,675). The work on this project has resulted in a number of technological innovations in the state of the art for integrating flexible thin-film solar cells with flex circuit harness technology and inflatable ultraviolet-light-rigidizable structures. The specific power, specific volume, for the Powersphere are presented in Figures 1 and 2 as a function of solar cell technology and efficiency. The Powersphere will enable microsatellite missions across NASA enterprises and DoD missions by providing ample electric power at an affordable cost. The Powersphere design provides attitude-independent electric power and thermal control for an enclosed microsatellite payload. The design is scalable, robust in high radiation environments and provides sufficient electric power to allow the use of electric propulsion. Electric propulsion enables precise positioning of microsatellites which is required for inspectors that would be deployed to inspect the International Space Station, Space Shuttle or large unmanned spacecraft. The Powersphere allows for efficient launch packaging versus deployed volume as shown in Figure 3.

Simburger, Edward J.↗

A Coarse Pointing Assembly for Optical Communication

In the framework of a contract with the European Space Agency, RUAG Space are developing a Coarse Pointing Assembly for an Optical Communication Terminal with the goal to enable high-bandwidth data exchange between GEO and/or LEO satellites as well as to earth-bound ground stations. This paper describes some development and testing aspects of such a high precision opto-mechanical device, with emphasis on the influence of requirements on the final design, the usage of a Bearing Active Preload System, some of the lessons learned on the BAPS implementation, the selection of a flex print design as rotary harness and some aspects of functional and environmental testing.

Szekely, G.↗

The Stretched Lens Array (SLA): An Ultra-Light Photovoltaic Concentrator

A high-performance, ultralight, photovoltaic concentrator array is being developed for space power. The stretched lens array (SLA) uses stretched-membrane, silicone Fresnel lenses to concentrate sunlight onto triple-junction photovoltaic cells. The cells are mounted to a composite radiator structure. The entire solar array wing, including lenses, photovoltaic cell flex circuits, composite panels, hinges, yoke, wiring harness, and deployment mechanisms, has a mass density of 1.6 kg/sq.m. NASA Glenn has measured 27.4% net SLA panel efficiency, or 375 W/sq.m. power density, at room temperature. At GEO operating cell temperature (80 C), this power density will be 300 W/sq.m., resulting in more than 180 W/kg specific power at the full wing level. SLA is a direct ultralight descendent of the successful SCARLET array on NASA's Deep Space 1 spacecraft. This paper describes the evolution from SCARLET to SLA, summarizes the SLA's key features, and provides performance and mass data for this new concentrator array.

ONeill, Mark J.↗

Development of a Thin-Film Solar Cell Interconnect for the Powersphere Concept

Dual junction amorphous silicon (a-Si) solar cells produced on polyimide substrate have been selected as the best candidate to produce a lightweight solar array for the PowerSphere program. The PowerSphere concept features a space-inflatable, geodetic solar array approximately 0.6 meters in diameter and capable of generating about 20W of electrical power. Trade studies of various wiring concepts and connection methods led to an interconnect design with a copper contact that wraps around the edge, to the back of the solar cell. Applying Plasma Vapor Deposited (PVD) copper film to both sides and the edge of the solar cell produces the wrap around contact. This procedure results in a contact pad on the back of the solar cell, which is then laser welded to a flex circuit material. The flex circuit is constructed of copper in a custom designed routing pattern, and then sandwiched in a Kapton insulation layer. The flex circuit then serves as the primary power distribution system between the solar cells and the spacecraft. Flex circuit material is the best candidate for the wiring harness because it allows for low force deployment of the solar cells by the inflatable hinges on the PowerSphere. An additional frame structure, fabricated and assembled by ILC Dover, will reinforce the wrap around contact-flex blanket connection, thus providing a mechanically robust solar cell interconnect for the PowerSphere multifunctional program. The PowerSphere team will use the wraparound contact design approach as the primary solution for solar cell integration and the flex blanket for power distribution.

Simburger, Edward J.↗

Development of a Novel Helmet Support Assembly for NASA Orion Crew Survival Suit

Orion Spacecraft water landing environments have necessitated the design and testing of a novel Helmet Support Assembly (HSA) as part of the NASA Orion Crew Survival Systems (OCSS) launch and re-entry spacesuit. A series of development sled tests using 5 th female, 50th male, and 95th male Hybrid III Anthropometric Test Devices (ATDs) simulated worst case water landings and identified the need for an integrated suit countermeasure to control the helmet during dynamic loading. Initial prototype countermeasures rigidly restrained the helmet keeping the helmet in place as desired, but led to large force and moment transmission to the upper neck. Further development led to a flexible HSA which used high-strength steel wire contoured to the size-matched ATD thorax and attached to both the front and rear of the neck ring. The selected wire diameter and contoured shape provided some ability to flex under the expected worst-case dynamic loads. The existing shoulder harness was used to restrain the helmet motion during “eyeballs out/down” loading while also attempting to prevent head-to-helmet contact in “eyeballs down” spinal-axis loading. A new small prototype helmet was also developed and tested for the 5th and 50th ATDs with both HSA devices. Dynamic impact tests were conducted on the HIA (Horizontal Impulse Accelerator) at Wright Patterson Air Force Base (WPAFB) under simulated off-nominal landing conditions using a representative Orion seat and 5-point harness. For each ATD size, peak Neck Injury Criteria (Nij) were compared to equivalent sled tests with an unsuited ATD configuration. Adding a helmet without attempting to control motion increased peak Nij values for all ATD sizes. The use of the rigid countermeasure showed decreased peak Nij results for the 5th female, but increased peak Nij values for both 50th configurations and the 95th male ATDs. By comparison, the flexible HSA showed reduced peak Nij values for all ATD sizes. Overall, this series of dynamic impact tests identified a risk of increased crew neck loading when under- or over-restraining the helmet during simulated Orion water landings and also demonstrated an effective strategy to mitigate those loads with a compliant HSA design.

Safety↗

CryoCart Restoration and Vacuum Pipe Construction

Propulsion systems that utilize hypergolic propellants have been used to power space vehicles since the beginning of the space program. Liquid methane and oxygen propulsion systems have emerged as an alternative and have proven to be more environmentally friendly. The incorporation of liquid methane/liquid oxygen (LOX) into the propulsion system has demonstrated an increase in engine performance, as well as a reduction in the volume, size and complexity of the system. Consequently, reducing the total mass of the vehicle which is a crucial aspect that is considered when planning space missions to both the Moon and Mars [1]. Project Morpheus has made significant advancements in liquid oxygen/liquid methane propulsion system technologies by incorporating a LOX/methane propulsion system to a vertical test bed. The vehicle consisted of a 5,000 lb main engine and four 20 lb remote control system (RCS) engines that utilize liquid methane/LOX as its propellant [1]. The vehicle completed successful flight testing at Kennedy Space Center in 2014 which marked the completion of the Morpheus project. Subsequent projects utilizing Morpheus' vertical test bed have been developed to make further advancements. One of the subsequent projects consisted of the addition of a smaller 2,000 lb main engine and a cold helium heat exchanger which would make it possible for a pressurant tank systems to be send to Mars or the Moon by significantly decreasing the overall mass and volume of the pressurant tank. The hot fire tests of the integrated system with the smaller main engine and cold helium heat exchanger were successful at sea level, but further studies are being conducted to better understand how the vertical test bed will behave under thermal-vacuum conditions. For this reason, the integrated vehicle will be taken to Plum Brook to be tested in a chamber capable of simulating these conditions. To ensure that the vehicle will function properly under vacuum conditions, testing will be first completed at the component level. During this process, the igniter of the main engine and the RCS thrusters will be tested under a vacuum. To complete the testing of the components, the test setup first needed to be finalized. The CryoCart is being used to feed the propellants to the test article. The CryoCart is a movable test set-up that was developed in 2009 to provide a mobile platform for testing oxygen/methane systems with hot-fire capability up to 100 lbf. The CryoCart consists of three different systems: Oxygen, Methane, and liquid Nitrogen. The Oxygen and Methane systems are placed into two different carts while the liquid nitrogen system is mainly located in the methane cart. Over the years, the CryoCart has been utilized for different projects and has undergone deterioration. For this reason, a new phase has been developed to rebuild it to working conditions once again. During my internship, I was aiding in the construction and restoration of the CryoCart. In the initial stages of the process, I updated the fluid and electrical schematics for the oxygen, methane, and test article systems. The original CryoCart consisted of an electrical panel that utilized electromechanical relays and a terminal to drive the igniter power and signal, as well as the main fuel and oxygen valves. This electrical panel connected to the CryoCart through various wire harnesses that could be found exiting from the CryoCart. First, it was determined how these harnesses connected to the electromechanical relays so that they worked correctly. Once the electrical system was understood, an alternative for the electromechanical relays and the Molex connectors used throughout the system was sought since these components can often prove to be unreliable. Solid State relays and MIL connectors were purchased to serve as replacements. Upon arrival of the parts, crimping and wiring was completed to install the new solid state relays and MIL connectors. During the replacement of the relays and connectors, system checks of the electrical system were ran to ensure that the system was working correctly. While completing system checks, the pressure transducers that were not functioning properly were also replaced and any issue with the wiring or signal was addressed. Once the electrical components were replaced, the restoration of the fluid system began. Parts of the tubing in the CryoCart had to be rebuild and often consisted of sizing, cutting, bending, filing, and sanding the tubing to prepare it to be flared. Many components had to be proof-tested to bring their certifications up to date, and several components had to be replaced. Various flex hoses, valves, and fittings were send to the Clean Lab because they were new, dirty, or had gone through proof-testing. Once they arrived from the cleaning lab they had to be put back to the system and leak checks and functional tests were conducted. In the Nitrogen system, the copper tubing located in the Oxygen cart was rebuild and Aerogel insulation was added to this section. A new gaseous nitrogen system was added to the CryoCart to purge the vacuum tube which will serve as the test chamber. Once the CryoCart was completed, construction of parts of the vacuum tube began. A flange was manufactured with welded fittings to hold the line of the vacuum pump as well as some extra fittings which will serve as extra inlets used to introduce fluid lines to the vacuum tube. Stress analysis was ran in this flange to ensure that it would not fail under vacuum conditions. The fluid lines leading from the air side of the vacuum to the test article were also constructed and added to the mount that had already been manufactured. Three different sets of tubing were constructed to accommodate the seven different RCS thruster and the main engine igniter that are going to be tested. Full electrical system checks were completed to ensure that all the wire harnesses and valves were functioning. Upon the completion of the CryoCart and the vacuum tube, hot fire testing for the RCS thrusters and the main engine igniter are going to begin. During this time any issues encountered with the engines or igniter will be addressed to ensure that the components function under vacuum conditions. After successful completion of testing, the vertical test bed, Morpheus, will be rebuilt and prepared to be sent to Plum Brook. In Plum Brook, the vehicle will be tested in the thermal-vacuum chamber to demonstrate that integrated lox-methane propulsion system operation in space-like conditions. This internship has allowed me the opportunity to gain valuable hands on experience and to develop skills that will aid in my education as well as in the workforce, while at the same time helping me determine that I would like to further pursue a career in propulsion engineering.

Chaidez, Mariana↗

Gravitational Effects upon Locomotion Posture

Researchers use actual microgravity (AM) during parabolic flight and simulated microgravity (SM) obtained with horizontal suspension analogs to better understand the effect of gravity upon gait. In both environments, the gravitational force is replaced by an external load (EL) that returns the subject to the treadmill. However, when compared to normal gravity (N), researchers consistently find reduced ground reaction forces (GRF) and subtle kinematic differences (Schaffner et al., 2005). On the International Space Station, the EL is applied by elastic bungees attached to a waist and shoulder harness. While bungees can provide EL approaching body weight (BW), their force-length characteristics coupled with vertical oscillations of the body during gait result in a variable load. However, during locomotion in N, the EL is consistently equal to 100% body weight. Comparisons between AM and N have shown that during running, GRF are decreased in AM (Schaffner et al, 2005). Kinematic evaluations in the past have focussed on joint range of motion rather than joint posture at specific instances of the gait cycle. The reduced GRF in microgravity may be a result of differing hip, knee, and ankle positions during contact. The purpose of this investigation was to compare joint angles of the lower extremities during walking and running in AM, SM, and N. We hypothesized that in AM and SM, joints would be more flexed at heel strike (HS), mid-stance (MS) and toe-off (TO) than in N.

DeWitt, John K.↗