Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flight test measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Deriving Transmissibility Functions from Finite Elements for Specifications

This work explores deriving transmissibility functions for a missile from a measured location at the base of the fairing to a desired location within the payload. A pressure on the outside of the fairing and the rocket motor’s excitation creates an acceleration at a measured location and a desired location. Typically, the desired location is not measured. In fact, it is typical that the payload may change, but measured acceleration at the base of the fairing is generally similar to previous test flights. Given this knowledge, it is desired to use a finite-element model to create a transmissibility function which relates acceleration from the previous test flight’s measured location at the base of the fairing to acceleration at a location in the new payload. Four methods are explored for deriving this transmissibility, with the goal of finding an appropriate transmissibility when both the pressure and rocket motor excitation are equally present. In conclusion, these methods are assessed using transient results from a simple example problem, and it is found that one of the methods gives good agreement with the transient results for the full range of loads considered.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Laser Measurements and Modeling of Shock Tunnel Freestream Velocity and Multispecies Thermal Nonequilibrium

Coherent anti-Stokes Raman scattering (CARS) and nitric oxide molecular tagging velocimetry (NO-MTV) were used to characterize the freestream in Sandia’s Hypersonic Shock Tunnel (HST) using a burst-mode laser operated at 100 kHz. Experiments were performed at nominal freestream velocities of 3 and 4 km/s using both air and N 2 test gas. The CARS diagnostic provides nonequilibrium characterization of the flow by measuring vibrational and rotational temperatures of N 2 and O 2 , which are compared to NO temperatures from separate laser absorption experiments. Simultaneous, collinear freestream velocities were measured using NO MTV along with pitot pressure measurements. Furthermore, this extensive freestream dataset is compared to nonequilibrium CFD that is capable of modeling species-specific, vibrational temperatures throughout the nozzle expansion. Significant nonequilibrium between vibrational and rotational temperatures was measured at each flow condition. N 2 exhibits the most nonequilibrium, followed by O 2 and NO. The CFD model captures this trend, although it consistently overpredicts N 2 and O 2 vibrational temperatures. At 3 km/s, the modeled NO nonequilibrium is underpredicted, whereas it is overpredicted at 4 km/s. Good agreement is seen between CFD and the velocity and rotational temperature measurements. Experiments with water added to the test gas yielded no discernable difference in vibrational relaxation.

Aerodynamics↗

Development of a Machine-Learned Cruise Guide Indicator for Rotorcraft

This paper presents a machine-learned virtual cruise guide indicator (vCGI) for Chinook helicopters. Two temporal neural networks were trained and evaluated on measured data from 55 flight tests, one for the fore rotor and another for the aft rotor, to predict a vCGI value, which protects 23 components from fatigue damage during steady-state conditions. Three different classes of machine learning architectures were evaluated for prediction of the vCGI from time sequences: a temporal convolutional neural network with 1D dilated causal convolutions, a long short-term memory recurrent neural network, and an attention-based transformer architecture. The final average model accuracy on unseen flight data is currently greater than 93% for CGI values which could result in fatigue damage and 90% for normal operation CGI values. Model accuracy was improved through a series of advancements in:(1) selection of optimal training data using temporal collective variables and unsupervised learning, (2) dataset augmentation with maximum-entropy temporal collective variables, and (3) implementation of a mixture-of-experts classification- regression approach using an adversarial classification approach to assign maneuver labels. The results are presented for each advancement in model development along with lessons learned in training machine learning models on real- world, time-dependent rotorcraft data.

Boyer, Mathew↗

Scattering Calorimeter FY24 Deliverable Report

A simulation-based method has been developed to prototype new detector designs for nuclear data measurements utilizing neutron scattering. This method uses representative physics inputs for signal and background generation, full detector resolution smearing benchmarked by experimental data, and a neutron beam timing simulation to produce analyzable output like a physical measurement. A test case has been studied using a hybrid time-of-flight calorimeter detector for scattering cross-section measurements on 239 Pu with 1-5 MeV incident monoenergetic neutrons. Data analysis methods have been developed to perform event-level particle reconstruction and reaction channel discrimination. This analysis has been used to estimate the capability of the test detector to perform simultaneous scattering and fission cross section measurements, as well as its ability to provide neutron spectra and particle angular information.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Strategies for the in-orbit gain tracking using the modulated X-ray sources for the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

Accurate and precise correction of the gain drift is the key to achieve the required energy resolution of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM). Therefore, Resolve is equipped with highly configurable X-ray sources called the modulated X-ray source (MXS). The pulsed nature allows us to separate calibration and astrophysical X-rays by time interval selections. However, undesirable characteristics of the MXS, such as the afterglow X-rays, restrict the allowed configuration range. Moreover, the nonlinear and discontinuous behaviors of the calibration line count rate make the determination of the optimal setting highly complex. The MXS count rate model has been established using measurements in the spacecraft thermal vacuum test with the flight detector and MXS. A trade-off study using the model enables us to choose a few settings for the continuous use of the MXS optimized for different ranges of target gain tracking intervals. An alternative approach, where the MXS is used only intermittently, has also been developed and implemented. This new mode enables us to reconstruct the drift without having most of the undesirable effects in science data. This also forms the basis of the gain tracking under the current Resolve configuration with the closed gate valve.

Astronomy and AstroPhysics↗

Predicting System Response at Unmeasured Locations

Traditional techniques to derive dynamic specification for components have a great deal of uncertainty. One of the major sources of uncertainty is that the number of response measurements in the operational system environment is insufficient to determine the component motion. This inadequacy is due to logistical limitations for data recording in field testing and space limitations for accelerometers, strain gages and associated wiring. Available measurements are often some distance from the component and therefore do not represent component motion. Typical straight-line envelopes of these unrepresentative measurements guarantee an increase in the uncertainty. In this paper multiple methods are attempted to expand a sparse set of field test measurements on a system to responses of interest that cannot be measured in the field due to the limitations. Proof of concept is demonstrated on the Modal Analysis Test Vehicle (MATV). The responses of interest, known as “truth responses”, are measured in a system vibration environment along with an optimized sparse set of 30 field responses. Methods to expand the field responses to the truth responses are demonstrated by comparing the acceleration spectral density of the expanded response to the measured response. Two methods utilize a validated finite element model of the MATV. One is developed from purely experiment based frequency response functions of a laboratory pre-test. Finally, these approaches are designed to drastically reduce the uncertainty of the component in-service motion as a basis for developing specifications that are guaranteed to be conservative with a known (instead of unknown) conservatism.

42 ENGINEERING↗

Cloud Droplet Measurement System for the ARM Tethered Balloon System (TBS) Field Campaign Report

The Mesa Photonics' cloud droplet measurement system (CDMS) performs in situ measurement of droplet size distribution and droplet number density in clouds. These characteristics are important cloud microphysical properties that are critical input parameters for atmospheric models and are also useful for proper calibration and validation of performance of other atmospheric measurement instrumentation. This small campaign was the first project (out of two) that involved integration of the CDMS into the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s tethered balloon system (TBS) and its initial testing at the ARM Southern Great Plains (SGP) atmospheric observatory. The follow-up campaign (AFC07016) involved testing of the CDMS under relevant conditions at the third ARM Mobile Facility (AMF3) at Oliktok Point, Alaska and making in situ measurements in clouds. The goal of this small field campaign was to deploy the CDMS on the ARM TBS, demonstrate its integrity and compatibility with the TBS, and test the wireless telecommunication system in preparation for subsequent in-cloud measurements at ARM’s North Slope of Alaska (NSA) observatory at Utqiagvik (formerly Barrow). The specific technical objectives included: (1) Integration of the Mesa Photonics' CDMS into the ARM TBS, (2) testing of the wireless telecommunication system of the CDMS, (3) evaluating the data acquisition software and image processing algorithms especially under high-background-illumination conditions, and (4) testing the ruggedness of the instrument's optical alignment and other performance characteristics. All objectives have been successfully met. The mounting hardware was designed and built mostly at Sandia National Laboratories (SNL), which allowed reliable mounting of the CDMS on the TBS and co-locating the CDMS with other instruments. The field tests were performed by the principal investigator (PI) in collaboration with the TBS operational crew led by D. Dexheimer. The field testing demonstrated good compatibility of the CDMS with the TBS. During the TBS flights, the crew did not experience any operational issues with the CDMS. The instrument demonstrated reliable operational characteristics, including sufficient battery life and good thermal management. The wireless telecommunication system has been successfully tested at TBS flight altitudes of up to 1000 m. During all flights, the CDMS raw data were wirelessly transmitted to the ground station and processed in real time. The ruggedness of the instrument's optical alignment was evaluated by performing calibration of the CDMS (using Mesa Photonics' fixed-size monodisperse droplet generator) before and after the campaign. The calibration was stable within the instrument's measurement precision. In summary, the campaign demonstrated good compatibility of the Mesa Photonics' CDMS with the ARM TBS. The flight tests confirmed the mechanical integrity of the CDMS and stability of its optical layout, as well as reliability of the wireless telecommunication system. Successful completion of this campaign provided a solid basis for the next campaign (AFC07016, November 2020), that involved testing of the CDMS during in-cloud TBS flights at AMF3 at Oliktok Point.

54 ENVIRONMENTAL SCIENCES↗

Balancing Impedance and Controllability in Response Reconstruction with $\mathrm{TS-IMMAT}$

In a prior work the authors proposed a variant on the Impedance Matched Multi-Axis Test (IMMAT) in which a fixture is defined, called the Transmission Simulator (TS), and the desired environment is matched at a set of sensors on the TS. If the motion of the TS is matched then the response of the rest of the component will also match, provided that the attached component has the same dynamics as it did when the environment was measured. Hence, one would like the TS to be flexible so that it reproduces the boundary conditions that the component of interest experiences during flight, but the more flexible the TS, the more shakers might be needed to control its response. This work presents a derivation that gives expressions for these two potential error sources in TS-IMMAT. Then, various case studies are presented, both on simulated and real hardware, to understand the importance of each error term in practical testing. The theory explains the phenomena that were observed when using measurements from a component that flew on a sounding rocket. The environmental response was measured and then various fixtures were attached, each comprising more of the next assembly, or the hardware to which the component was attached in flight. MIMO testing was repeated with each fixture and the results were compared to seek to understand the role of the impedance match in this type of testing. Here the results show that the number of modes that are active in the transmission simulator is also very important, and so the best solution balances these two considerations. An improved method of simulating the MIMO test is then proposed, so simulations can be used to predict what fixture, or transmission simulator, will give the best results in a TS-IMMAT test.

42 ENGINEERING↗

Operational Uncrewed Aircraft Systems Development for Meteorology and Atmospheric Physics Field Campaign Report

The overarching goal of the project is to develop integrated small, unmanned aircraft systems (SUAS) capabilities for enhanced atmospheric physics measurements. This team included atmospheric scientists, meteorologists, engineers, computer scientists, geographers, and chemists necessary to evaluate the needs and develop the advanced sensing and imaging, robust autonomous navigation, enhanced data communication, and data management capabilities required to use SUAS in atmospheric physics. The flight campaigns at the Southern Great Plains (SGP) U.S. Department of Energy Atmospheric Radiation Measurement (ARM) observatory were an integrated evaluation of the systems in coordinated field tests. This enabled sensor testing, and validation of SUAS technology and integration of unmanned aircraft into the airspace. The set of experiments enabled evaluation and progression of remote UAS deployment operations with observing atmospheric sensors. Each flight test endeavor was notable for the significant lessons learned during every deployment event. Team size and roles, equipment use, aircraft instruments, meteorological instruments, and deployment logistics, were all evaluated and improved at every flight-testing day. The details of these are further discussed in the Results section.

54 ENVIRONMENTAL SCIENCES↗

In-flight performance of the XRISM/Resolve detector system

The Resolve instrument was launched on board the XRISM observatory in early September 2023. The Resolve spectrometer is based on a high-sensitivity X-ray calorimeter detector system (DS) that has been successfully deployed in many ground and sub-orbital spectrometers. However, the Resolve instrument is the first long-term implementation in space. The instrument will provide essential diagnostics for nearly every class of X-ray emitting objects, from galactic supernova remnants to the outskirts of galaxy clusters, without degradation for spatially extended objects. The Resolve DS consists of a 36-pixel microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the DS demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous bandpass from below 0.3 keV to above 12 keV and a timing precision better than 100μs. An anti-coincidence detector placed directly behind the microcalorimeter array effectively suppresses background. The detector energy-resolution budget included terms for interference from the Resolve cooling system and the spacecraft. Additional terms for energy-scale stability, on-orbit effects, and use of mid-grade events were also included, predicting an end-of-life, on-orbit performance for high- and mid-resolution grade events that meet the requirement of 7 eV FWHM at 6 keV. Here, we discuss the actual on-orbit performance of the Resolve DS and compare this with the performance in pre-flight testing, on-orbit predictions, and the almost identical Hitomi/SXS instrument. We will also discuss the on-orbit gain stability, an assessment of on-orbit interference, and measurements of the on-orbit background.

Astronomy and AstroPhysics↗

Nitric oxide molecular tagging velocimetry of a free-flight model in a reflected shock tunnel

Nitric oxide molecular tagging velocimetry (NO MTV) is used to characterize the wake behind a free-flight spherical model in the test section of a free-piston reflected shock tunnel using a burst-mode laser operated at 100 kHz. A novel (to our knowledge) multi-delay timing scheme was implemented to measure velocity in a varying collisional environment in the wake of the free-flight model. Four simultaneous velocity profiles were measured in the wake of the model from -600 to 3600 m/s for flow enthalpies of 10.3 and 12.0 MJ/kg. Finally, the measured velocity distributions show good agreement when compared to computational fluid dynamics (CFD) modeling.

47 OTHER INSTRUMENTATION↗

Test Flights of NOAA Ozone Photometer for Uncrewed Aerial Systems (UAS)/Balloon-Based Studies (OPUS) during TRACER (Field Campaign Report)

We proposed to integrate and fly the National Oceanic and Atmospheric Administration (NOAA) Ozone Photometer for Uncrewed Aerial Systems (UAS)/Balloon-Based Studies (OPUS) on the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s tethered balloon system (TBS) during the second phase (August 1-15) of the 2022 Tracking Aerosol Convection Interactions Experiment (TRACER) in southwest Houston, Texas. The two main goals were: 1) Test fly the sensor to discover and address any potential problems such as interface and communication with other instruments, interferences with other instruments and radio, and 2) If OPUS performs well, then inter-compare OPUS with the EN-SCI ozonesondes that will also be flown on the TBS. The collaborating institutions are DOE Sandia National Laboratories TBS team, the University of Houston, and St. Edward's University.

47 OTHER INSTRUMENTATION↗

Investigation of a digitizer for the plastic scintillation detectors of time-of-flight mass measurements

A CAEN DT5742 digitizer has been investigated to process the fast signals from the photomultiplier tubes of the time-of-flight detectors for fast ion beams. A test setup consisting of two plastic scintillation detectors and a pulsed laser source provided signals which were recorded by the digitizer and systematically analyzed with different algorithms to derive the amplitude, rise time and arrival time of the detection signal. To obtain the best amplitude and time resolutions, various optimization techniques including peak fitting and signal smoothing, interpolation improvement, and time-walk correction by amplitude and rise time have been performed and compared in detail. Here we compared the time resolutions obtained by three digital algorithms of leading-edge, zero-crossing constant-fraction (ZC-CFD) and direct constant-fraction discriminations. Finally, we found that the best time-of-flight resolution between two PMTs can be achieved as 12 ps by the method using sample minimum for peak location and using the time-walk-resistant ZC-CFD with 4-point interpolation for timing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative texture analysis using the NOMAD time-of-flight neutron diffractometer

Strategies for efficient and reliable texture measurements have been explored using the Nanoscale Ordered Materials Diffractometer (NOMAD) at the Spallation Neutron Source located at Oak Ridge National Laboratory (ORNL). To test these strategies, the texture of an Al alloy was also investigated using another neutron diffraction instrument, a constant-wavelength neutron diffractometer (NRSF2) located at the High Flux Isotope Reactor, also at ORNL. Reasonable agreement was found across the two experimental methods, but differences in overall texture strength and the symmetry of some components were noted, depending on the data reduction and analysis method selected. Finally, on the basis of these results, potential improvements are identified which would enhance the texture measurement capability on NOMAD.

47 OTHER INSTRUMENTATION↗

Low power implementation of high frequency SiPM readout for Cherenkov and scintillation detectors in TOF-PET

State-of-the-art (SoA) electronic readout for silicon photomultiplier (SiPM)-based scintillation detectors that demonstrate experimental limits in achievable coincidence time resolution (CTR) leverage low noise, high frequency signal processing to facilitate a single photon time response that is near the limit of the SiPMs architecture. This readout strategy can optimally exploit fast luminescence and prompt photon populations, and promising measurements show detector concepts employing this readout can greatly advance PET detector CTR, relative to SoA in clinical systems. However, the technique employs power hungry components which make the electronics chain impractical for channel-dense time-of-flight (TOF)-PET detectors. We have developed and tested a low noise and high frequency readout circuit which is performant at low power and consists of discrete elements with small footprints, making it feasible for integration into TOF-PET detector prototypes. A 3 × 3 mm 2 Broadcom SiPM with this readout chain exhibited sub-100 ps single photon time resolution at 10 mW of power consumption, with a relatively minor performance degradation to 120 ± 2 ps FWHM at 5 mW. CTR measurements with 3 × 3 × 20 mm 3 LYSO and fast LGSO scintillators demonstrated 127 ± 3 ps and 113 ± 2 ps FWHM at optimal power operation and 133 ± 2 ps and 121 ± 3 ps CTR at 5 mW. BGO crystals 3 × 3 × 20 mm 3 in size show 271 ± 5 ps FWHM CTR (1174 ± 14 ps full-width-at-tenth-maximum (FWTM)) at optimal power dissipation and 289 ± 8 ps (1296 ± 33 ps FWTM) at 5 mW. The compact and low power readout topology that achieves this performance thereby offers a platform to greatly advance PET system CTR and also opportunities to provide high performance TOF-PET at reduced material cost.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

169 Tm ( n , γ ) cross section and statistical decay properties from measurements at the DANCE facility

Background: Radiative neutron capture on thulium, which is a monoisotopic element, plays a role in different applications such as nuclear astrophysics or nuclear burning environments. Considerable discrepancies—reaching 20%—exist between evaluations in the unresolved-resonance region. Furthermore, experimental data on statistical 𝛾 decay in odd-odd rare-earth nuclei is scarce. There are still open questions about the systematics of the so-called scissors mode in the 𝑀⁢1 photon strength function, especially in odd-odd nuclei. Purpose: This work is focused on two main topics—deriving experimental 169 Tm ⁢(𝑛,𝛾) cross section and studying statistical 𝛾 decay of 170 Tm, in particular properties of the scissors mode. Methods: The capture experiments to obtain experimental cross section were performed at the Los Alamos Neutron Science Center using the time-of-flight technique and employing the Detector for Advanced Neutron Capture Experiments. Measured coincident 𝛾-ray spectra were also compared with statistical simulations using the dicebox code to test different models of level density and photon strength functions. Results: The capture cross section was determined from 1.8 eV to 0.97 MeV, the broadest neutron-energy range ever measured for this isotope. Several new resonances have been observed. The statistical 𝛾 decay of 170 Tm cannot be reproduced without a scissors mode resonance centered at ≈ 3.3MeV. Conclusions: The measured cross section in the unresolved-resonance region is generally lower than the latest evaluations. The derived 169 Tm 𝑠-process abundance is expected to increase by a factor of 1.26, while the changes of the abundances of elements heavier than 169 Tm are in the order of 0.2%. The scissors mode properties in 170 Tm are similar to those deduced in previous analyses of neighboring nuclei 168 Er and 166 Ho .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In-orbit operation of Resolve Filter Wheel and modulated X-ray source

The Resolve soft X-ray spectrometer is a high spectral resolution microcalorimeter spectrometer for the X-ray Imaging and Spectroscopy Mission. In the beam of Resolve, there is a filter wheel containing X-ray filters. In the beam, there is also an active calibration source, the modulated X-ray source (MXS), which can provide pulsed X-rays to facilitate gain calibration. The filter wheel consists of six filter positions. Two open positions, one 55 Fe source to aid in spectrometer characterization during the commissioning phase, and three transmission filters: a neutral density filter, an optical blocking filter, and a beryllium filter. The X-ray intensity, pulse period, and pulse separation of an MXS are highly configurable. Furthermore, the switch-on time is synchronized with the spacecraft’s internal clock to give accurate start and end times of the pulses. One of the issues raised during ground testing was the susceptibility of an MXS at high voltage to ambient light. Although measures were taken to mitigate the light leak, the efficacy of those measures must be verified in orbit. Along with an overview of issues raised during ground testing, we will discuss the calibration source and the filter performance in-flight and compare with the transmission curves present in the Resolve calibration database.

X-ray Imaging and Spectroscopy Mission/Resolve↗

Aerosol Inlets for a Mid-Sized Uncrewed Aerial System (UAS)

The purpose of this technical report is to document the efforts to design and test two inlet systems for aerosol sampling suitable for deployment on a medium-sized fixed-wing Uncrewed Aerial System (UAS). This work, which was supported by the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) user facility, was conducted at the Pacific Northwest National Laboratory (PNNL) for the ARM Aircraft Facility (AAF) starting in November 2017. The current work is a part of AAF efforts to instrument the ArcticShark (a mid-sized UAS owned and operated by the AAF) for atmospheric research and develop a scientific payload for deployment on a similar-sized UAS with minimal adaptation and integration. An aerosol inlet system is necessary to sample and transport ambient air sample to the scientific instrumentation with minimal distortions to the aerosols. Two isokinetic aerosol inlets were designed: the first is a simple passive system for a single instrument suitable to be installed in a wing pylon; the second is a system with active control designed to sample and distribute air among several heterogeneous instruments and to provide basic humidity control of the air sample so that the measured aerosol parameters should correspond to “dry” conditions (a common requirement). Both systems could be easily adapted for deployment on another platform and/or with a different set of instrumentation. Several conducted flight tests showed that the inlets’ performance met our design goals.

54 ENVIRONMENTAL SCIENCES↗