Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow cell”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Flow cell systems, flow cell batteries, and hydrogen production processes

Flow cell systems are provided. Example flow cell systems can include an H + /H 2 half-cell and a counterpart Fe 3+ /Fe 2+ or V 5+ /V 4+ half-cell. Flow cell systems can also include a half-cell in fluid communication with an electrolyte regeneration chamber. Embodiments of these flow cells systems can be configured to produce hydrogen through electrolysis. Flow cell battery systems are also disclosed. Example flow cell battery systems can include an H + /H 2 analyte; and a counterpart Fe 3+ /Fe 2+ or V 5+ /V 4+ catholyte. Processes for generating hydrogen are also disclosed. Example processes can include generating protons from a Fe 3+ /Fe 2+ or V 5+ /V 4+ electrolyte solution; and reacting the protons with H 2 O to form H 2 .

Wang, Wei↗

Windowless Optical Cell Flow System

One of the goals for advanced integrated nuclear safeguards is on-line optical analysis of molten salt in molten salt reactors and electrochemical fuel reprocessing facilities. While progress has been made in the development of optical techniques that may be suitable for on-line analysis of molten salts, significant technology gaps exist with regard to integrating these analytical techniques into industrial-scale processes. One key technological hurdle is the short service life of optical window materials, which are subject to clouding and scaling during extended exposure to molten salts. To address this issue, Argonne is developing a gravity flow cell with open-apertures to support on-line optical analysis without the need for salt-wetted windows. The flow cell uses gravity flow and fluid dynamics principles to enable molten salt flow through a pipe that has holes in its wall through which salt does not flow. In FY21, an open-aperture gravity flow cell with windowless optical access to flowing salt was successfully demonstrated. Future work should include the integration of the flow cell into a sampling loop, stakeholder outreach and collaboration, integration of multiple optical analysis techniques, evaluation of the integrated methods, and analyses to determine how the various tools might fit into an integrated safeguards monitoring system of unattended near real time monitoring tools.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Review of Hydrogen/Halogen Flow Cells

Flow batteries provide an energy-storage solution for various grid-related stability and service issues that arise as renewable-energy-generation technologies are adopted. Among the most promising flow-battery systems are those using hydrogen/halogen redox couples, which promise the possibility of meeting the cost target of the US Department of Energy (DOE), due to their fast and reversible kinetics and low materials cost. However, significant critical issues and barriers for their adoption remain. In this review of halogen/hydrogen systems, technical and performance issues, and research and development progress are reviewed. The information in this review can be used as a technical guide for research and development of related redox-flow-battery systems and other electrochemical technologies.

25 ENERGY STORAGE↗

Gravity induced flow cell

The flow cell includes first and second reservoirs having a selected volume containing a flowable redox electrode. A membrane separates charged and discharged material. An energy-extraction region includes electronically conductive porous current collectors through or adjacent to which the flowable redox electrodes flow and to which charge transfer occurs. Structure is provided for altering orientation of the flow cell whereby gravity induces flow of the flowable redox electrode between the first and second reservoirs to deliver power. By varying the angle of the cell, flow rate and power delivered on discharge or the charge rate on charge may be varied.

25 ENERGY STORAGE↗

Optimization of electrode characteristics for the Br-2/H-2 redox flow cell

The Br-2/H-2 redox flow cell shows promise as a high-power, low-cost energy storage device. The effect of various aspects of material selection, processing, and assembly of electrodes on the operation, performance, and efficiency of the system is determined. In particular, (+) electrode thickness, cell compression, hydrogen pressure, and (-) electrode architecture are investigated. Increasing hydrogen pressure and depositing the (-) catalyst layer on the membrane instead of on the carbon paper backing layers have a large positive impact on performance, enabling a limiting current density above 2 A cm(-2) and a peak power density of 1.4 W cm(-2). Maximum energy efficiency of 79 % is achieved. In addition, the root cause of limiting-current behavior in this system is elucidated, where it is found that Br- reversibly adsorbs at the Pt (-) electrode for potentials exceeding a critical value, and the extent of Br- coverage is potential-dependent. This phenomenon limits maximum cell current density and must be addressed in system modeling and design. These findings are expected to lower system cost and enable higher efficiency.

Tucker, MC↗

Electrocapturing flow cell

A flow cell for electrophoretically-assisted capturing analytes from a flow. The flow cell includes a specimen chamber, a first membrane, a second membrane, a first electrode chamber, and a second electrode chamber. The specimen chamber may have a sample inlet and a sample outlet. A first portion of the first membrane may be coupled to a first portion of the specimen chamber. A first portion of the second membrane may be coupled to a second portion of the specimen chamber. The first electrode chamber may be configured to accept a charge. A portion of the first electrode chamber may be coupled to a second portion of the first membrane. A second electrode chamber may be configured to accept an opposite charge. A portion of the second electrode chamber may be coupled to a second portion of the second membrane.

47 OTHER INSTRUMENTATION↗

Impact of membrane characteristics on the performance and cycling of the Br-2-H-2 redox flow cell

The Br-2/H-2 redox flow cell shows promise as a high-power, low-cost energy storage device. In this paper, the effect of various aspects of material selection and processing of proton exchange membranes on the operation of the Br-2/H-2 redox flow cell is determined. Membrane properties have a significant impact on the performance and efficiency of the system. In particular, there is a tradeoff between conductivity and crossover, where conductivity limits system efficiency at high current density and crossover limits efficiency at low current density. The impact of thickness, pretreatment procedure, swelling state during cell assembly, equivalent weight, membrane reinforcement, and addition of a microporous separator layer on this tradeoff is assessed. NR212 (50 mu m) pretreated by soaking in 70 degrees C water is found to be optimal for the studied operating conditions. For this case, an energy efficiency of greater than 75% is achieved for current density up to 400 mA cm(-2), with a maximum obtainable energy efficiency of 88%. A cell with this membrane was cycled continuously for 3164 h. Membrane transport properties, including conductivity and bromine and water crossover, were found to decrease moderately upon cycling but remained higher than those for the as-received membrane. (C) 2015 Elsevier B.V. All rights reserved.

Tucker, MC↗

Design and characterization of “flow-cell” integrated-flow active cooling for high-average-power ceramic optics

We used COMSOL Multiphysics to design a prototype actively cooled “flow-cell” substrate targeted at high-average-power applications, fabricated the prototype from cordierite ceramic, and tested the substrate under load in our thermal loading test stand. Sub-aperture testing revealed average-power handling up to 3.88-W/cm 2 absorbed power density, in excellent agreement with model predictions. Gratings fabricated on 2-in.-diam cordierite coupons were subjected to laser-damage testing and showed a damage threshold of 250 mJ/cm 2 .

47 OTHER INSTRUMENTATION↗

Characterizing the Impact of Oligomerization on Redox Flow Cell Performance

Abstract Redox flow batteries (RFBs) are hindered by complex failure modes, particularly crossover through the membrane, resulting in capacity fade and reduced cycling efficiencies. Redox‐active oligomers (RAOs) have recently been proposed for mitigating this phenomenon while maintaining sufficient transport properties; however, to date, few studies have quantified how the chemical and electrochemical properties of RAOs influence their performance in redox flow cells. Here, we demonstrate that oligomeric derivatives of 2,2,6,6‐tetramethylpiperidine 1‐oxyl (TEMPO) exhibit lower diffusivities than the monomeric species but retain facile charge transfer characteristics. The size‐dependent variations in mass transport rates directly translate to differences in flow cell polarization and symmetric cycling performance. Post‐mortem analyses reveal that oligomerization does not meaningfully alter decay processes as evinced by similar capacity fade across all species. Broadly, these findings corroborate and extend upon previously developed relationships between molecular size, electrochemical properties, and flow cell performance.

36 MATERIALS SCIENCE↗

Internally manifolded flow cell for an all-iron hybrid flow battery

In one example, a system for a flow cell for a flow battery, comprising: a first flow field; and a polymeric frame, comprising: a top face; a bottom face, opposite the top face; a first side; a second side, opposite the first side; a first electrolyte inlet located on the top face and the first side of the polymeric frame; a first electrolyte outlet located on the top face and the second side of the polymeric frame; a first electrolyte inlet flow path located within the polymeric frame and coupled to the first electrolyte inlet; and a first electrolyte outlet flow path located within the polymeric frame and coupled to the first electrolyte outlet. In this way, shunt currents may be minimized by increasing the length and/or reducing the cross-sectional area of the electrolyte inlet and electrolyte outlet flow paths.

Evans, Craig↗

Internally manifolded flow cell for an all-iron hybrid flow battery

In one example, a system for a flow cell for a flow battery, comprising: a first flow field; and a polymeric frame, comprising: a top face; a bottom face, opposite the top face; a first side; a second side, opposite the first side; a first electrolyte inlet located on the top face and the first side of the polymeric frame; a first electrolyte outlet located on the top face and the second side of the polymeric frame; a first electrolyte inlet flow path located within the polymeric frame and coupled to the first electrolyte inlet; and a first electrolyte outlet flow path located within the polymeric frame and coupled to the first electrolyte outlet. In this way, shunt currents may be minimized by increasing the length and/or reducing the cross-sectional area of the electrolyte inlet and electrolyte outlet flow paths.

25 ENERGY STORAGE↗

Internally manifolded flow cell for an all-iron hybrid flow battery

In one example, a system for a flow cell for a flow battery, comprising: a first flow field; and a polymeric frame, comprising: a top face; a bottom face, opposite the top face; a first side; a second side, opposite the first side; a first electrolyte inlet located on the top face and the first side of the polymeric frame; a first electrolyte outlet located on the top face and the second side of the polymeric frame; a first electrolyte inlet flow path located within the polymeric frame and coupled to the first electrolyte inlet; and a first electrolyte outlet flow path located within the polymeric frame and coupled to the first electrolyte outlet. In this way, shunt currents may be minimized by increasing the length and/or reducing the cross-sectional area of the electrolyte inlet and electrolyte outlet flow paths.

Evans, Craig↗

Internally manifolded flow cell for an all-iron hybrid flow battery

In one example, a system for a flow cell for a flow battery, comprising: a first flow field; and a polymeric frame, comprising: a top face; a bottom face, opposite the top face; a first side; a second side, opposite the first side; a first electrolyte inlet located on the top face and the first side of the polymeric frame; a first electrolyte outlet located on the top face and the second side of the polymeric frame; a first electrolyte inlet flow path located within the polymeric frame and coupled to the first electrolyte inlet; and a first electrolyte outlet flow path located within the polymeric frame and coupled to the first electrolyte outlet. In this way, shunt currents may be minimized by increasing the length and/or reducing the cross-sectional area of the electrolyte inlet and electrolyte outlet flow paths.

Evans, Craig↗

The Poor Academic’s DC-Offset for Reversing Polarity in Electrochemical Cells: Application to Redox Flow Cells

We provide a simple and inexpensive manual DC-offset method for extending the accepted voltage range of a battery cycler to negative voltages, without interfering with the actual operation of the electrochemical cell under the test or exceeding the voltage specs of the battery cycler instrument. We describe the working principles of the method and validate the proposed setup by operating short-term and long-term redox flow battery cycling using compositionally symmetric cell, with open-circuit voltage of zero, and full cell configurations. The method can be used to extend the capability of battery cycler instrumentation to operate any electrochemical cell that requires the polarity to be reversed during operation. Applications include cycling of other symmetric cells (e.g., Li-ion cells), implementation of polarity reversal steps for rejuvenation of electroactive species or rebalancing electrochemical cells, and alternating polarity for electrochemical synthesis.

25 ENERGY STORAGE↗

Optimization of the cerium-hydrogen redox flow cell

The Ce—H2 redox flow cell is optimized using commercially-available cell materials. Cell performance is found to be sensitive to the upper charge cutoff voltage, membrane boiling pretreatment, methanesulfonic-acid concentration, (+) electrode surface area and flow pattern, and operating temperature. Performance is relatively insensitive to membrane thickness, Cerium concentration, and all features of the (−) electrode including hydrogen flow. Cell performance appears to be limited by mass transport and kinetics in the cerium (+) electrode. Maximum discharge power of 895 mW cm−2 was observed at 60° C.; an energy efficiency of 90% was achieved at 50° C. The Ce—H2 cell is promising for energy storage assuming one can optimize Ce reaction kinetics and electrolyte.

Tucker, Michael C.↗

A novel flow cell for optical particle analyzers—application to measurements of Malvern Insitec under high pressure and temperature

A flow cell is a necessary measurement interface for some important optical analyzers. In our application of the flow cell, we utilize a state-of-the-art optical analyzer (Malvern Insitec) to measure particle size distribution and concentration in-situ in a sampled flow from a novel pressurized oxygen-fuel combustion process. However, since this sampling flow is a flow of moist flue gas under high temperature and pressure, and the flow contains particles and corrosive acid gases, it is an extreme challenge to obtain a flow cell with a high optical quality that does not perturb the measurement. To address this challenge, we propose a new design for an optical flow cell. By using a unique flow field in the proposed flow cell, the measurement zone can be well defined by the sampling flow, minimizing the influence of purge flow. To demonstrate this flow cell, we have built a test system, and conduct measurements utilizing polydisperse-particle standards (10-100 µm and 1-10 µm). The results reveal that the optical windows are well protected by the purge flow field, without risk of deposition from the sampling flow, and the Malvern Insitec can measure the particle size distribution by using this flow cell, without generating sample bias.

Cheng, Mao↗