Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow condensation correlations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluation and development of flow condensation correlations using the data from low GWP refrigerants in an axial micro-fin aluminum tube

To mitigate global warming, the world is transitioning to refrigerants with low global warming potential (GWP). Supporting this shift requires a model that can accurately predict the heat transfer and pressure drop of new refrigerants, crucial for designing efficient heat exchangers. Existing models, however, are largely based on currently deployed refrigerants and primarily developed for unexpanded micro-fin tubes with spiral angles of 6° to 30°. Their applicability to new refrigerants, especially in expanded micro-fin tubes, is uncertain. This study assesses the performance of four well-known condensation models for six emerging refrigerants—R-32, R-454B, R-454C, R-455A, R-1234yf, and R-1234ze(E)—against experimental data. Initially, the Han and Lee (2005) model shows the best prediction accuracy with a mean absolute deviation (MAD) of 22.1 %. To enhance the accuracy of heat transfer models for new refrigerants and geometries with large temperature glides, two approaches are proposed. Here, the first approach applies a simple correction factor, reducing the MAD of the Cavallini et al. (2009) model from 68.2 % to 15.4 %. The second approach uses the variable metric method for minimization, fitting new constants to the data. This optimization results in the Kedzierski and Goncalves (1997) model achieving the highest accuracy, with a MAD of 13.1 %. For pressure drop models, the Cavallini et al. (1997) model is the most accurate with a MAD of 6.4 %, followed by the Haraguchi et al. (1993) model with a MAD of 9.4 %. Due to its simplicity, the Haraguchi et al. (1993) model is a practical option for predicting frictional pressure drop.

Axial micro-fin tubes↗

Flow condensation heat transfer performance of natural and emerging synthetic refrigerants

There is great interest in predicting flow condensation heat transfer for lower global warming potential (GWP) fluids. This paper analyzes the efficacy of common flow condensation correlations developed for particular fluids in order to identify their suitability to predict heat transfer performance of low GWP fluids. Condensation heat transfer data were extracted from the literature, including 19 papers and 1,473 data points for natural refrigerants [i.e., ammonia (R717), CO 2 (R744), propane (R290), isobutane (R600a)] and 35 papers and 5,030 data points for synthetic refrigerants [i.e., R12, R1234yf, R1234ze(E), R1234ze(Z), R22, R32, R41, R123, R125, R134a, R142b, R152a, R161, R404A, R410A, R448A, R449A, R450A, R452B, R454C, R455A, R513A] encompassing tube diameters of 0.1–11.5 mm, mass fluxes of 55–1200 kg/m2s, and saturation temperatures of -25°C–65°C. Correlations analyzed included Akers et al. (1959), Cavallini et al. (2006, 2011), Kim and Mudawar (2013), Macdonald and Garimella (2016), Shah (1979, 2009, 2013, 2016) and Traviss et al. (1973) for smooth tubes and Chamra et al. (2005) and Kedzierski and Goncalves (1999) for enhanced tubes. Since most studies did not report wall temperature, correlations which relied on wall temperature directly or indirectly were excluded from the analysis. For synthetic refrigerants, mean average error (MAE) ranged from 6%–257%, and Cavallini et al. (2011) and Kim and Mudawar (2013) were the best predictors for emerging synthetic refrigerants. Furthermore, the Kim and Mudawar (2013) correlation was found to best predict the heat transfer performance for propane and R600a data, but most correlations did not accurately predict ammonia and CO 2 flow condensation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development, calibration, and validation of a novel gray-box energy model for residential split air conditioners

Energy models for vapor compression refrigeration in residential air conditioners have been developed through white-box, gray-box, and black-box methods in decades. However, existing white-box and gray-box models require complicated equations with detailed geometries while black-box models require substantial experimental data. Further, this paper aims to develop and validate a simple gray-box steady-state energy model without the need for detailed geometries, which can accurately predict the cooling capacity and electrical power input based on outdoor and indoor air conditions, and supply airflow rates. First three state variables, including the evaporation and condensation temperatures, and refrigerant mass flowrate, are applied to develop the energy model and are solved by three physical equations, including the energy conservations at the evaporator and condenser, and the refrigerant volume-mass flow correlation of the compressor. Secondly, seven performance property functions related to three state variables and three physical equations are identified and calibrated by simple temperature and power measurements. Finally, field experiments are conducted on a residential air conditioner to calibrate these performance property functions and validate the developed model. The validated results reveal the model can accurately predict the cooling capacity and electrical power input, with the normalized root mean square errors of 2.3% and 0.87% respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Gluonic hot spot initial conditions in heavy-ion collisions

The initial conditions in heavy-ion collisions are calculated in many different frameworks. The importance of nucleon position fluctuations within the nucleus and subnucleon structure has been established when modeling initial conditions for input to hydrodynamic calculations. However, there remain outstanding puzzles regarding these initial conditions, including the measurement of the near equivalence of the elliptical v 2 and triangular v 3 flow coefficients in ultracentral 0–1% Pb + Pb collisions at the CERN Large Hadron Collider. Recently a calculation termed magma incorporating gluonic hot spots via two-point correlators in the color glass condensate framework, and no nucleons, provided a simultaneous match to these flow coefficients measured by the ATLAS experiment, including in ultracentral 0–1% collisions. Our calculations reveal that the magma initial conditions do not describe the experimental data when run through full hydrodynamic sonic simulations or when the hot spots from one nucleus resolve hot spots from the other nucleus, as predicted in the color glass condensate framework. Finally, we also explore alternative initial condition calculations and discuss their implications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Correlations in the Initial Conditions of Heavy-Ion Collisions

Ultracentral collisions of heavy nuclei, in which the impact parameter is nearly zero, are especially sensitive to the details of the initial state model and the microscopic mechanism for collective flow. In a hydrodynamic “flow” picture, the final state momentum correlations are a direct response to the fluctuating initial geometry, although models of the initial geometry differ widely. Alternatively, dynamical mechanisms based in the color glass condensate (CGC) formalism can naturally lead to many-body correlations with very different systematics. Here we present a calculation of event-by-event elliptic flow in both the hydrodynamic and CGC paradigms and show that they can be qualitatively distinguished in ultracentral collisions of deformed nuclei. Specifically, the multiplicity dependence in such collisions is qualitatively opposite, with the CGC correlations increasing with multiplicity while the hydrodynamic correlations decrease. The consistency of the latter with experimental data on UU collisions appears to rule out a CGC-mediated explanation. We find that these qualitative features also persist in small deformed systems and can therefore be a valuable test of the microscopic physics in that regime.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Benchmark of interfacial area concentration approaches for the two-fluid model in gas-dispersed condensing flow

Accurate predictions of interfacial area concentration (IAC) are required for closure of the condensation phase change term. The interfacial area transport equation (IATE) can dynamically predict interfacial area concentration and is increasingly being used in the benchmarking of phase change flows over static based correlations which require a flow regime map. For higher flow regimes, the two-group two-fluid IATE model can separately model the transport of spherical bubbles and cap/slug bubbles. Recently, a modified formulation of the one-group and two-group two-fluid model with interfacial area transport equation was proposed for gas-dispersed condensing flows. Three datasets have been used for validation consisting of condensing two-phase flow data in the unheated section of a vertical annulus with conditions spanning a range of pressures, inlet subcoolings and mass fluxes for benchmarking the various IAC approaches. For bubbly flows, the coupled void transport - IATE simulation results in good agreement in the predictions of the void fraction and the interfacial area concentration under nearly all sixty conditions. Considering the proposed two-group two-fluid IATE model formulation, the group-2 Nusselt number correlation is investigated to account for the appropriate heat transfer length scale for group-2 bubbles. Validation of the proposed two-group two-fluid model against the new dataset shows good agreement with experimental data with significant improvement over the one-group IATE model for conditions with substantial group-2 void fraction throughout the simulation domain.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of Electro-static Assisted Air Dehumidification

The removal of water vapor from the air to reduce relative humidity is a well-known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. Also, the findings from the literature focused mainly on small flow rates on the order of one to two cfm. Electrically-enhanced condensation consists of the use of highly charged particles, preferably highly charged water droplets, that attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. An effect of the electric charge is the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation. Consequently, the equilibrium between evaporation and condensation is shifted towards condensation. Following the application of the modified Kelvin-Thomson theory, we developed a preliminary physics-based model to predict an effective size range of the charged droplets for optimal dehumidification. The range resulted in about 2 to 4 μm in diameter, under few simplifying assumptions. The effect of the size and the charge of the electrosprayed droplets on the overall dehumidification rate was briefly discussed. The use of electrosprays to produce small but highly charged droplets was broadly discussed in this paper. The cone-jet mode was identified as the most suitable electrospray operational mode, and it generated droplets of small size and high electrical charge. The cone-jet stability was also analyzed in detail. The preliminary data of the present work and the model results indicated that several electrospray heads were required to achieve a 5% dehumidification rate for airflow rates of about 5 cfm.

Morcelli, Stefano↗

Analysis of New Data of Electro-static Assisted Air Dehumidification Processes

The removal of water vapor from the air to reduce relative humidity is a well-known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. Also, the findings from the literature focused mainly on small flow rates on the order of one to two cfm. Electrically-enhanced condensation consists of the use of highly charged particles, preferably highly charged water droplets, that attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. An effect of the electric charge is the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation. Consequently, the equilibrium between evaporation and condensation is shifted towards condensation. Following the application of the modified Kelvin-Thomson theory, we developed a preliminary physics-based model to predict an effective size range of the charged droplets for optimal dehumidification. The range resulted in about 2 to 4 m in diameter, under few simplifying assumptions. The effect of the size and the charge of the electrosprayed droplets on the overall dehumidification rate was briefly discussed. The use of electrosprays to produce small but highly charged droplets was broadly discussed in this paper. The cone-jet mode was identified as the most suitable electrospray operational mode, and it generated droplets of small size and high electrical charge. The cone-jet stability was also analyzed in detail. The preliminary data of the present work and the model results indicated that several electrospray heads were required to achieve a 5% dehumidification rate for airflow rates of about 5 cfm.

Morcelli, Stefano↗

Potential for exciton condensation in a highly conductive amorphous polymer

An outstanding challenge in synthesis and theory is to develop molecular materials at ambient conditions that exhibit highly efficient energy transfer. Here, in this study, we demonstrate the potential of a recently synthesized, highly conductive amorphous material—a nickel tetrathiafulvalene-tetrathiolate (NiTTFtt) polymer—to become an exciton condensate—a Bose-Einstein condensate of particle-hole pairs, known as excitons, that supports dissipationless flow of excitation energy. While exciton condensates have recently been realized in ordered materials, we show by advanced electronic structure calculations that this highly correlated phenomenon can potentially be realized in molecularly tailored, amorphous materials. In contrast to the Bechgaard salts that support superconductivity at compressed geometries requiring high pressures, we show that the recently synthesized, amorphous NiTTFtt polymer exhibits the computational signature of exciton condensation at experimentally realizable geometries, occurring at ambient pressures. Results suggest that superfluidity in this system and related systems—including van der Waals structures, molecular metals with extended-TTF dithiolate ligands, and Bechgaard salts—may occur via a nontraditional excitonic mechanism tuneable according to system composition, geometry, size, and charge. This study prompts further experimental investigation of the rational design of molecularly scaled exciton condensates with potential applications to efficient transport in technologically relevant materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Title Coherent X-ray Studies of Surface Growth and Patterning Processes

X-ray Photon Correlation Spectroscopy (XPCS) is being developed as a tool to study nanoscale dynamics of fluctuations during thin film growth and surface patterning. XPCS examines the evolution of the X-ray scattering speckle pattern in reciprocal space to reveal dynamics information not accessible through any other means. Unlike low-coherence conventional X-ray scattering, which incoherently averages over different regions of a sample, coherent X-ray scattering is sensitive to the detailed structure of a given sample at that moment in time. In thin film growth processes, heterodyning, which occurs due to coherent mixing of two scattered signals, can be used to investigate the relationship between surface growth velocity and defect propagation. And, for polycrystalline thin film growth, the spatial coherence of the X-ray beam can substitute for the missing spatial coherence of the growth process to track layered growth in detail, even in a growth regime in which there are no conventional growth oscillations of the X-ray intensity. This has opened the door for detailed dynamics studies of individual atomic layers during real-world growth and patterning, not just in perfect single-crystal growth cases, which greatly expands the applicability of in-situ X-ray scattering methods. Step-flow dynamics in mounded polycrystalline growth has been studied separately for two thin film organic semiconductors deposited by thermal deposition in a vacuum environment, C60 and diindenoperylene (DIP). Highly oriented polycrystalline thin films are readily obtained in both systems, where mounds are composed of crystalline monolayer-height steps and terraces in a so-called wedding cake morphology. The formation of mounds is understood to be due to significant Ehrlich-Schwoebel step edge barriers that inhibit molecules from hopping down from one layer to the one below. The mounds exhibit local step flow, which can be monitored using coherent X-ray scattering. This is made possible due to heterodyning between scattering from the average mounds and the moving steps, which becomes visible in XPCS analysis. The effect of desorption, i.e. re-evaporation of deposited molecules is found to be important for understanding these processes. The impact of this work is to enable testing of models of step dynamics, the shape of mounds, and merging of mounds to form continuous thin films. Highly ordered polycrystalline thin films deposited on inexpensive substrates have applications in thin film solar cells and other organic electronic devices. In a separate set of experiments, speckle analysis during self-organized ion beam nanopatterning reveals memory stretching back to the beginning of patterning in the early stages and enables measurement of the velocity of self-organized patterns across surfaces providing the possibility of stringent new tests of the theory of pattern formation and motion.

36 MATERIALS SCIENCE↗

Thermo-hydraulic steam pipe models for district heating simulations: Simplifications to balance accuracy and simulation speed

Steam piping networks are essential for optimizing performance in industrial processes and district heating systems. However, dynamic models that balance thermo-hydraulic accuracy with computational efficiency remain limited. In response, this paper presents a new discretized steam pipe model based on the plug flow approach, capturing key thermo-hydraulic behaviors while simplifying steam phase change processes. Implemented in Modelica, the model accurately calculates temperature and pressure distributions along steam pipelines. To improve computational efficiency for district-scale simulations, five model simplifications are introduced: lumped thermo-hydraulic functions, empirical correlations, fluid state approximations, steady-state dynamics and inclusion of flow derivatives. These simplified models achieve 85%-98% accuracy in predicting pressure drop and condensation losses, including dynamic condensate behavior during pipe warm-up—a factor often overlooked in existing models. The models support diverse network configurations, scaling effectively to systems with multiple distribution pipes and connected building loads. Discrete models provide detailed insights but exhibit a cubic increase in simulation time as the network scales by N connected building O(N 2.42 ). In contrast, lumped models simulate 10–28 times faster than discrete, offering quadratic scaling of simulation time O(N 1.73 ). However, they still require 6 times more computation time than a lossless network, highlighting the inherent computational challenges of modeling compressible fluid flow. In conclusion, the steady-state lumped variant, with its near-linear scalability in computational time O(N 1.01 ), emerges as an efficient solution for preliminary design evaluations and extensive parametric studies.

15 GEOTHERMAL ENERGY↗

Lessons from intramolecular singlet fission with covalently bound chromophores

Molecular dimers, oligomers, and polymers are versatile components in photophysical and optoelectronic architectures that could impact a large variety of applications. We present a perspective on such systems in the field of singlet fission, which effectively multiplies excitons and produces a unique excited state species, the triplet pair. The choice of chromophore and the nature of the attachment between units, both geometrical and chemical, play a defining role in the dynamical scheme that evolves upon photoexcitation. Specific final outcomes (e.g., separated and uncorrelated triplet pairs) are being sought through rational design of covalently bound chromophore architectures built with guidance from recent fundamental studies that correlate structure with excited state population flow kinetics.

36 MATERIALS SCIENCE↗

Observable signatures of initial state momentum anisotropies in nuclear collisions

In this work, we show that the correlation between the elliptic momentum anisotropy v 2 and the average transverse momentum [ p T ] at fixed multiplicity in small system nuclear collisions carries information on the origin of the observed momentum anisotropy. A calculation using a hybrid IP-Glasma+ music +UrQMD model that includes contributions from final state response to the initial geometry as well as initial state momentum anisotropies of the color glass condensate predicts a characteristic sign change of the correlator ρ ^ ( v 2 2 , [ p T ] ) as a function of charged particle multiplicity in p + Au and d + Au collisions at s = 200 GeV , and p + Pb collisions at s = 5.02 TeV . This sign change is absent in calculations without initial state momentum anisotropies. The model further predicts a qualitative difference between the centrality dependence of ρ ^ ( v 2 2 , [ p T ] ) in Au + Au collisions at s = 200 GeV and Pb + Pb collisions at s = 5.02 TeV , with only the latter showing a sign change in peripheral events. Predictions for O + O collisions at different collision energy show a similar behavior. Experimental observation of these distinct qualitative features of ρ ^ ( v 2 2 , [ p T ] ) in small and large systems would constitute strong evidence for the presence and importance of initial state momentum anisotropies predicted by the color glass condensate effective theory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultracentral Collisions of Small and Deformed Systems at RHIC

We study a range of collision systems involving deformed ions and compare the elliptic and triangular flow harmonics produced in a hydrodynamics scenario versus a color glass condensate (CGC) scenario. For the hydrodynamics scenario, we generate initial conditions using TRENTO and work within a linear response approximation to obtain the final flow harmonics. For the CGC scenario, we use the explicit calculation of two-gluon correlations taken in the high-p T “(semi)dilute-(semi)dilute” regime to express the flow harmonics in terms of the density profile of the collision. Here, we consider ultracentral collisions of deformed ions as a testbed for these comparisons because the difference between tip-on-tip and side-on-side collisions modifies the multiplicity dependence in both scenarios, even at zero impact parameter. We find significant qualitative differences in the multiplicity dependence obtained in the initial conditions+hydrodynamics scenario and the CGC scenario, allowing these collisions of deformed ions to be used as a powerful discriminator between models. We also find that sub-nucleonic fluctuations have a systematic effect on the elliptic and triangular flow harmonics which are most discriminating in 0–1% ultracentral symmetric collisions of small deformed ions and in 0–10% d197Au collisions. The collision systems we consider are 238 U 238 U, d 197 Au, 9 Be 197 Au, 9 Be 9 Be, 3 He 3 He, and 3 He 197 Au.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Film condensation with high heat fluxes and scaled experiments using pure steam for reactor containment cooling

Condensation tests were performed using a newly developed test facility for scaling the passive containment cooling system (PCCS) to a small modular reactor (SMR). The PCCS of the SMR plays a pivotal role in ensuring greater safety, reliability, and compactness than what is afforded by traditional reactors. Therefore, a well-designed PCCS is essential to SMRs. However, previous studies and test data were unsuitable for scaling, due to high variation in the test geometry and operating conditions. This study intends to close this research gap by using a novel designed scaled test facility consisting of vertical condensing test sections featuring 1-, 2-, and 4-inch-diameter condensing tubes with annular water cooling, and by applying superheated and saturated steam with different steam mass flow ranges of 5–25 g/s. Further, the primary test data, including axial temperatures, mass flow rates, and pressures, were used in conjunction with a standard data reduction method to estimate critical parameters such as heat fluxes, heat transfer coefficients, and condensation rates. These scaled test data would support improving empirical correlations and validating condensation models to identify scaling distortion for SMR PCCSs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Entangled phase of simultaneous fermion and exciton condensations realized

Fermion-exciton condensates (FECs)—computationally and theoretically predicted states that simultaneously exhibit the character of superconducting states and exciton condensates—are novel quantum states whose properties may involve a hybridization of superconductivity and the dissipationless flow of energy. Here, we exploit prior investigations of superconducting states and exciton condensates on quantum devices to identify a tuneable quantum state preparation entangling the wave functions of the individual condensate states. Utilizing this state preparation, we prepare a variety of FEC states on quantum computers—realizing strongly correlated FEC states on current, noisy intermediate-scale quantum devices—and verify the presence of the dual condensate via postmeasurement analysis. This confirmation of the previously predicted condensate state on quantum devices as well as the form of its wave function motivates further theoretical and experimental exploration of the properties, applications, and stability of FECs.

36 MATERIALS SCIENCE↗

Hydrodynamic electron transport near charge neutrality

We develop the theory of hydrodynamic electron transport in a long-range disorder potential for conductors in which the underlying electron liquid lacks Galilean invariance. For weak disorder, we express the transport coefficients of the system in terms of the intrinsic kinetic coefficients of the electron liquid and the correlation function of the disorder potential. We apply these results to analyze the doping and temperature dependence of transport coefficients of graphene devices. In this work, we show that at charge neutrality, long-range disorder increases the conductivity of the system above the intrinsic value. The enhancement arises from the predominantly vortical hydrodynamic flow caused by local deviations from charge neutrality. Its magnitude is inversely proportional to the shear viscosity of the electron liquid and scales as the square of the disorder correlation radius. This is qualitatively different from the situation away from charge neutrality. In that case, the flow is predominantly potential and produces negative viscous contributions to the conductivity, which are proportional to the sum of shear and bulk viscosities and inversely proportional to the square of disorder correlation radius.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗